Platelet storage in a plasma-free medium.

Abstract:

:Currently, platelet concentrates are stored in 50 to 60 ml of plasma. A major drawback to storage in plasma is the considerable loss of platelet function which occurs during storage. A modified Tyrodes medium has been developed for storage of platelets. A comparison between platelet concentrates stored in this medium and in plasma showed that platelet aggregation and release responses to synergistic pairs of stimuli were equivalent for both types of concentrates on the day of preparation and after 72 hours. Platelet aggregation and release responses to single stimuli, the content of membrane glycoproteins, and the pH declined during storage but were similar for both preparations. The data show that plasma is not required to maintain in vitro platelet function during storage of platelet concentrates, but in vivo functions remain to be determined. The use of an artificial medium has the advantages of decreasing patient exposure to plasma contaminants, generating additional plasma for fractionation, and controlling more exactly the storage environment.

journal_name

Transfusion

journal_title

Transfusion

authors

Rock G,Swenson SD,Adams GA

doi

10.1046/j.1537-2995.1985.25686071429.x

subject

Has Abstract

pub_date

1985-11-01 00:00:00

pages

551-6

issue

6

eissn

0041-1132

issn

1537-2995

journal_volume

25

pub_type

杂志文章
  • Recruitment of unrelated persons as bone marrow donors. A preliminary experience.

    abstract::Seven hundred and sixty-three blood donors previously typed for HLA-A and B antigens were asked to consider donating bone marrow to unrelated patients for whom no HLA-matched sibling was available. Eighty-eight percent (668) indicated willingness to donate marrow, and of these, 615 (81%) participated in testing and 53...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1986.26486262736.x

    authors: McElligott MC,Menitove JE,Aster RH

    更新日期:1986-07-01 00:00:00

  • Enhanced HPC recruitment in children using LVL and a new automated apheresis system.

    abstract:BACKGROUND:A new automated apheresis system has recently been reported as useful in improving peripheral blood HPC collection in adults. The aim of this study has been to verify the utility of this system (AutoPBSC, COBE BCT) for standard leukapheresis and for LVL in the pediatric setting. STUDY DESIGN AND METHODS:A p...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.2000.40040404.x

    authors: Torrabadella M,Olivé T,Ortega JJ,Massuet L

    更新日期:2000-04-01 00:00:00

  • Leukocyte depletion of red cell units at the bedside by transfusion through a new filter.

    abstract::Standard packed red cell (PRC) units can be depleted of leukocytes and platelets if they are transfused through a blood administration set in which the usual 170-mu filter has been replaced by a leukocyte removal filter (Sepacell R-500). During a 6-month period, 1550 PRC units were transfused through this filter in 61...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1987.27587320533.x

    authors: Sirchia G,Rebulla P,Parravicini A,Carnelli V,Gianotti GA,Bertolini F

    更新日期:1987-09-01 00:00:00

  • A case for stocking O D+ red blood cells in emergency room trauma bays.

    abstract:BACKGROUND:AABB Standard 5.27 requires transfusion services to have a process for urgent release of blood before completion of compatibility testing. Our institution endorses a policy for the emergency release of group O, D+ red blood cells (RBC; O+ RBC) to males and females at least 50 years of age. Our emergency depa...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/trf.12925

    authors: Meyer E,Uhl L

    更新日期:2015-04-01 00:00:00

  • Analysis of apheresis content of progenitor cell collections from normal donors to whom granulocyte-colony-stimulating factor is administered.

    abstract:BACKGROUND:Allogeneic blood cell transplantation is a new alternative to bone marrow transplantation. Preliminary data suggest that granulocyte-colony-stimulating factor (G-CSF)-mobilized peripheral blood progenitor cells from normal donors can provide rapid hematopoietic engraftment without significant increases in tr...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1996.36111297091734.x

    authors: Weinthal JA,Nemunaitis JJ,Aston S,Magsamen MJ,Rosenfeld CS

    更新日期:1996-11-01 00:00:00

  • Further evaluation of a new standard of efficacy for stored platelets.

    abstract:BACKGROUND:The proposal to assess the viability capabilities of platelets (PLTs) collected, treated, or stored in a developmental system against "fresh" PLTs from the same subject poses several important methodologic issues pertaining to the timing and manner of the collecting and separating the fresh PLTs. This study ...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/j.1537-2995.2005.00177.x

    authors: AuBuchon JP,Herschel L,Roger J

    更新日期:2005-07-01 00:00:00

  • Effects of interruptions of controlled-rate freezing on the viability of umbilical cord blood stem cells.

    abstract:BACKGROUND:An optimal cooling rate is critical for cryopreserving cord blood stem cells, so it is generally achieved by using controlled-rate freezers (CRFs). The cooling rate can be interrupted by many factors during cooling; therefore, a proper response to the interruption in cryopreservation is crucial to prevent th...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/trf.12774

    authors: Yang H,Pidgorna A,Loutfy MR,Shuen P

    更新日期:2015-01-01 00:00:00

  • A 'new' high frequency antigen Era.

    abstract::Three examples of an antibody defining a 'new' high frequency red blood cell antigen, Era, are described. Family studies show Era to be inherited, but the mode of inheritance may not be straightforward. ...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1982.22382224938.x

    authors: Daniels GL,Judd WJ,Moore BP,Neitzer G,Ouellet P,Plantos M,Verrette S

    更新日期:1982-05-01 00:00:00

  • An automated motivational interview promotes donation intention and self-efficacy among experienced whole blood donors.

    abstract:BACKGROUND:Interventions intended to motivate donors to return can be costly and time consuming. The current study examined the effect of a Web-based automated interview, informed by motivational interviewing and self-determination theory, on donor intention, motivation, and behavior in a sample of highly experienced d...

    journal_title:Transfusion

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/trf.15402

    authors: Livitz IE,France CR,France JL,Fox KR,Ankawi B,Slepian PM,Kessler DA,Rebosa M,Shaz BH

    更新日期:2019-09-01 00:00:00

  • A comparative study of the postoperative allogeneic blood-sparing effects of tranexamic acid and of desmopressin after total knee replacement.

    abstract:BACKGROUND:Tissue hypoxia and reperfusion induce abnormal hemostatic function. Therefore, bleeding after total knee replacement (TKR) may be a result of a tourniquet-induced imbalance of the procoagulant and fibrinolytic systems. Because laboratory confirmation of tourniquet-induced abnormal hemostasis is difficult to ...

    journal_title:Transfusion

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1046/j.1537-2995.2001.41101285.x

    authors: Zohar E,Fredman B,Ellis MH,Ifrach N,Stern A,Jedeikin R

    更新日期:2001-10-01 00:00:00

  • High-throughput HBV DNA and HCV RNA detection system using a nucleic acid purification robot and real-time detection PCR: its application to analysis of posttransfusion hepatitis.

    abstract:BACKGROUND:A high-throughput detection system was developed for HBV DNA and HCV RNA. METHODS:A combination of real-time detection PCR using an automated system (PRISM 7700, PE Biosystems, Foster City, CA) and automatic viral nucleic acid extraction (BioRobot 9604, Qiagen, Hilden, Germany) was used as the high-throughp...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.2002.00024.x

    authors: Mitsunaga S,Fujimura K,Matsumoto C,Shiozawa R,Hirakawa S,Nakajima K,Tadokoro K,Juji T

    更新日期:2002-01-01 00:00:00

  • A novel approach to pathogen reduction in platelet concentrates using short-wave ultraviolet light.

    abstract:BACKGROUND:Transfusion of platelet concentrates (PCs) is the basic treatment for severe platelet disorders. PCs carry the risk of pathogen transmission, especially bacteria. Pathogen reduction (PR) by addition of photochemical reagents and irradiation with visible or ultraviolet (UV) light can significantly reduce this...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/j.1537-2995.2009.02334.x

    authors: Mohr H,Steil L,Gravemann U,Thiele T,Hammer E,Greinacher A,Müller TH,Völker U

    更新日期:2009-12-01 00:00:00

  • Fanconi syndrome in a patient with β-thalassemia major after using deferasirox for 27 months.

    abstract:BACKGROUND:Deferasirox (DFRA) is a new approved oral iron chelator. Its advantages are that it is convenient and better tolerated and adhered to due to "once-daily" oral dosage. However, its use in the field is limited and it is yet to be subjected to postmarketing surveillance. CASE REPORT:A 18.75-year-old male with ...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/j.1537-2995.2010.02939.x

    authors: Wei HY,Yang CP,Cheng CH,Lo FS

    更新日期:2011-05-01 00:00:00

  • Estimating the transfusion transmission risk of Q fever.

    abstract:BACKGROUND:The Q fever outbreaks in the Netherlands in 2007 to 2009 initiated discussion on the necessity of measures to prevent transmission through blood products. Risk assessments help transfusion regulators decide when and where measures are required. This study assesses the transfusion transmission (TT) risk of Q ...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/trf.12539

    authors: Oei W,Kretzschmar ME,Zaaijer HL,Coutinho R,van der Poel CL,Janssen MP

    更新日期:2014-07-01 00:00:00

  • Self-reported historic human immunodeficiency virus (HIV) testing in a Brazilian blood donor HIV case-control study.

    abstract:BACKGROUND:There has been increased worldwide emphasis on the many benefits of human immunodeficiency virus (HIV) serostatus awareness for both infection prevention and improved treatment outcomes. Previous studies indicate that donors may use blood donation to be tested; the objectives of this analysis were to assess,...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/trf.13792

    authors: Bruhn R,Moreno E,Sabino EC,Ferreira NA,Carneiro-Proietti AB,Lopes ME,Sampaio D,Loureiro P,Custer B,Goncalez TT,National Heart, Lung and Blood Institute Retrovirus Epidemiology Donor Study-II (REDS-II) International Component.

    更新日期:2016-11-01 00:00:00

  • Anti-Holley (hy): characterization of another example.

    abstract::Anti-Hy, in a serum of a black man who had received multiple blood transfusions, was found to be a warm reactive and polyclonal IgG antibody which did not bind complement in vitro. 51Cr-labeled Hy-positive red blood cells in the patient showed a shortened "2-component" survival curve. Hy antigens were not detected on ...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1975.15676082238.x

    authors: Hsu TC,Jagathambal K,Sabo BH,Sawitsky A

    更新日期:1975-11-01 00:00:00

  • Hemovigilance survey of pathogen-reduced blood components in the Warsaw Region in the 2009 to 2013 period.

    abstract:BACKGROUND:In 2009 the Mirasol Pathogen Reduction Technology (PRT) was introduced to the routine blood component production of the Regional Blood Transfusion Center in Warsaw (RBTCW). The goal of this study was to investigate the safety of Mirasol-treated blood components. STUDY DESIGN AND METHODS:The accumulated pass...

    journal_title:Transfusion

    pub_type: 杂志文章,评审

    doi:10.1111/trf.13330

    authors: Łętowska M,Przybylska Z,Piotrowski D,Lachert E,Rosiek A,Rzymkiewicz L,Cardoso M

    更新日期:2016-03-01 00:00:00

  • The influence of bleeding on trigger changes for platelet transfusion in patients with chemotherapy-induced thrombocytopenia.

    abstract:BACKGROUND:For patients with thrombocytopenia without bleeding risk factors, a platelet transfusion trigger of 10 × 10(9) /L is recommended. No studies have evaluated the clinicians' decision-making process leading to trigger changes. STUDY DESIGN AND METHODS:We report on the evaluation of trigger changes and the rela...

    journal_title:Transfusion

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1537-2995.2012.03727.x

    authors: Rioux-Massé B,Laroche V,Bowman RJ,Lindgren BR,Cohn CS,Pulkrabek SM,McCullough J

    更新日期:2013-02-01 00:00:00

  • Effect of storage of red blood cells on alloimmunization.

    abstract:BACKGROUND:Red blood cells (RBCs) undergo changes during storage. Various studies have suggested a higher risk of adverse and often multifactorial clinical outcomes associated with older-stored RBCs. Our aim therefore was to examine if storage of transfused RBCs is also associated with the risk of RBC-specific alloanti...

    journal_title:Transfusion

    pub_type: 杂志文章,多中心研究

    doi:10.1111/trf.12156

    authors: Zalpuri S,Schonewille H,Middelburg R,van de Watering L,de Vooght K,Zimring J,van der Bom JG,Zwaginga JJ

    更新日期:2013-11-01 00:00:00

  • Evaluation of commercial antiglobulin sera over a two-year period. Part I. Anti-beta 1A, anti-alpha 2D, and anti-beta 1E levels.

    abstract::Antiglobulin sera from nine different manufacturers have been tested, over a two-year period, for their ability to detect the complement components beta 1A, alpha 2D, and beta 1E. The results demontrate considerable variation in the abilities of sera from different manufacturers to detect these components and indicate...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/j.1537-2995.1974.tb04498.x

    authors: Issitt PD,Issitt CH,Wilkinson SL

    更新日期:1974-03-01 00:00:00

  • Flow cytometric quantitation of serum anti-D in pregnancy.

    abstract:BACKGROUND:The major cause of fetal hemolytic disease is maternal immunization to D in D-incompatible pregnancies. To prevent complications, D-incompatible pregnancies are monitored for the level of maternal anti-D. At present, the monitoring of anti-D levels is performed by the indirect antiglobulin test complemented ...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1996.36696269507.x

    authors: Christensson M,Bremme K,Shanwell A,Westgren M,Christensson B

    更新日期:1996-06-01 00:00:00

  • Does an intrauterine exchange transfusion improve the fetal prognosis in parvovirus infection cases?

    abstract:BACKGROUND:Almost 20% of parvovirus B19 foetal infections require intrauterine transfusions. In addition, myocardial dysfunction has been observed in severe parvovirus B19 infections. One objective of an intrauterine exchange transfusion (IUET) is to avoid an overload during the transfusion. Our aim was to study the ob...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/trf.14968

    authors: Vanspranghels R,Houfflin-Debarge V,Vaast P,Coulon C,Clouqueur E,Hanssens S,Rakza T,Subtil D,Garabedian C

    更新日期:2019-01-01 00:00:00

  • A typology of blood donor motivations.

    abstract:BACKGROUND:Although the need for whole blood is declining, so too are the number of first-time and repeat blood donors. To develop new recruitment and retention strategies, therefore, we need to draw on as wide a variation in blood donor motivations as possible. The primary aim of this study is to draw on a large surve...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/trf.15913

    authors: Ferguson E,Hill A,Lam M,Reynolds C,Davison K,Lawrence C,Brailsford SR

    更新日期:2020-09-01 00:00:00

  • Risk for malaria in United States donors deferred for travel to malaria-endemic areas.

    abstract:BACKGROUND:Deferral for travel to malaria-endemic areas excludes many blood donors in the United States. Most transfusion-transmitted malaria is associated with lengthy residence in malaria-endemic areas rather than routine travel. This study compares the impact of existing deferral requirements to the risk that a pres...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/j.1537-2995.2009.02290.x

    authors: Spencer B,Steele W,Custer B,Kleinman S,Cable R,Wilkinson S,Wright D

    更新日期:2009-11-01 00:00:00

  • Effects of Intercept pathogen reduction treatment on extended cold storage of apheresis platelets.

    abstract:BACKGROUND:Platelets pose the greatest transfusion-transmitted infectious risk among blood products. Refrigeration of platelets can mitigate bacterial contamination and extend platelet shelf life. Implementation of pathogen reduction technologies (PRTs) at blood banks has become increasingly popular to protect against ...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/trf.16096

    authors: Agey A,Reddoch-Cardenas K,McIntosh C,Sharma U,Cantu C,Cap A,Bynum J

    更新日期:2020-12-08 00:00:00

  • Sampling errors and the precision associated with counting very low numbers of white cells in blood components.

    abstract::Attention to the accurate and precise measurement of the white cell (WBC) content of transfused products has risen in response to awareness of the potential benefits of WBC-depleted components and the development of technical capabilities to produce these components. The techniques thus far reported have focused on th...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1991.31591263198.x

    authors: Dumont LJ

    更新日期:1991-06-01 00:00:00

  • Hemostatic effects of fibrinogen gamma-chain dodecapeptide-conjugated polymerized albumin particles in vitro and in vivo.

    abstract:BACKGROUND:Prototypes of platelet (PLT) substitutes have been studied and the focus was on a dodecapeptide, HHLGGAKQAGDV (H12), which is a fibrinogen gamma-chain carboxy-terminal sequence (gamma 400-411) and exists only in the fibrinogen domain. STUDY DESIGN AND METHODS:H12 was conjugated to the surface of polymerized...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/j.1537-2995.2005.00173.x

    authors: Okamura Y,Takeoka S,Teramura Y,Maruyama H,Tsuchida E,Handa M,Ikeda Y

    更新日期:2005-07-01 00:00:00

  • Performance profile of an updated safety measure rapid assay for bacteria in platelets.

    abstract:BACKGROUND:The Verax PGD rapid test for bacteria in platelets (PLTs) has been updated to simplify workflow and improve specificity and sensitivity by employing a novel sequential format. The performance of this updated version, called PGDprime, was evaluated to determine its suitability for use as an FDA-cleared "safet...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/trf.16000

    authors: Vallejo RP,Shinefeld L,LaVerda D,Best N,Lawrence G,Lousararian A,Hornbaker N,Rasmusson P,Mintz PD

    更新日期:2020-11-01 00:00:00

  • Addressing gaps in international blood availability and transfusion safety in low- and middle-income countries: a NHLBI workshop.

    abstract::In April 2017, a workshop sponsored by the National Heart, Lung, and Blood Institute, Division of Blood Diseases and Resources, and the Center for Translation Research and Implementation Science was held to discuss blood availability and transfusion safety in low- and middle-income countries (LMICs). The purpose of th...

    journal_title:Transfusion

    pub_type: 杂志文章,评审

    doi:10.1111/trf.14598

    authors: Custer B,Zou S,Glynn SA,Makani J,Tayou Tagny C,El Ekiaby M,Sabino EC,Choudhury N,Teo D,Nelson K,Peprah E,Price L,Engelgau MM

    更新日期:2018-05-01 00:00:00

  • Automated RBC exchange compared to manual exchange transfusion for children with sickle cell disease is cost-effective and reduces iron overload.

    abstract:BACKGROUND:Chronic transfusion in sickle cell disease (SCD) remains the gold standard therapy for stroke prevention and for patients with severe disease despite adequate hydroxyurea treatment. The aim of our study was to assess the safety and efficacy of automated red blood cell exchange (aRBX) in patients with SCD pre...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/trf.14575

    authors: Dedeken L,Lê PQ,Rozen L,El Kenz H,Huybrechts S,Devalck C,Diallo S,Heijmans C,Ferster A

    更新日期:2018-06-01 00:00:00