Sonographic evaluation of non-inflammatory neck masses in children.

Abstract:

:A review of the sonographic findings in 17 children with non-inflammatory neck masses suggests that while ultrasound is nonspecific with regard to the differential diagnosis, it can show whether a mass is cystic, solid, or complex. Sonography is also useful in clarifying the anatomical extent of a lesion and involvement of underlying normal structures.

journal_name

Radiology

journal_title

Radiology

authors

Friedman AP,Haller JO,Goodman JD,Nagar H

doi

10.1148/radiology.147.3.6682560

subject

Has Abstract

pub_date

1983-06-01 00:00:00

pages

693-7

issue

3

eissn

0033-8419

issn

1527-1315

journal_volume

147

pub_type

杂志文章
  • Abdominal CT with low tube voltage: preliminary observations about radiation dose, contrast enhancement, image quality, and noise.

    abstract:PURPOSE:To prospectively investigate the effect of low tube voltage on radiation dose, contrast enhancement, image quality, and image noise at abdominal dynamic computed tomography (CT). MATERIALS AND METHODS:The institutional review board approved this study. Prior informed consent was obtained from all patients. For...

    journal_title:Radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1148/radiol.2373041655

    authors: Nakayama Y,Awai K,Funama Y,Hatemura M,Imuta M,Nakaura T,Ryu D,Morishita S,Sultana S,Sato N,Yamashita Y

    更新日期:2005-12-01 00:00:00

  • Method for measuring three-dimensional motion with tagged MR imaging.

    abstract::Recent methods of magnetic resonance imaging involve the placement of a grid of planes of saturation over the imaging plane; distortion of the grid corresponds to tissue displacement in two dimensions. An extension to this method that allows measurement of motion in the third dimension involves a second acquisition th...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.181.2.1924810

    authors: Pipe JG,Boes JL,Chenevert TL

    更新日期:1991-11-01 00:00:00

  • Thermography, mammography, and clinical examination in breast cancer screening. Review of 16,000 studies.

    abstract::Breast cancer screening detected 139 biopsy-proved malignancies in 16,000 slef-selected women (8.7/1,000). In these, xeroradiography detected 78% (109), clinical examination 55% (76), and thermography 39% (54). In all 16,000 women, the thermogram was interpreted as positive in 17.9% (2,864). The greatest effectiveness...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/122.1.123

    authors: Feig SA,Shaber GS,Schwartz GF,Patchefsky A,Libshitz HI,Edeiken J,Nerlinger R,Curley RF,Wallace JD

    更新日期:1977-01-01 00:00:00

  • Ethmoid sinus disease: CT evaluation in 400 cases. Part II. Postoperative findings.

    abstract::Clinical, pathologic, and computed tomographic (CT) findings were reviewed in 400 patients with ethmoid sinus disease, including 272 who had undergone surgery. The postoperative appearance of ethmoid sinuses on CT scans is a highly neglected subject in radiologic literature. The unique ethmoid anatomy permits a variet...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.159.3.3704140

    authors: Som PM,Lawson W,Biller HF,Lanzieri CF

    更新日期:1986-06-01 00:00:00

  • Multisection CT protocols: sex- and age-specific conversion factors used to determine effective dose from dose-length product.

    abstract:PURPOSE:To determine conversion factors for the new International Commission on Radiological Protection (ICRP) publication 103 recommendations for adult and pediatric patients and to compare the effective doses derived from Monte Carlo calculations with those derived from dose-length product (DLP) for different body re...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.10100047

    authors: Deak PD,Smal Y,Kalender WA

    更新日期:2010-10-01 00:00:00

  • Assessment of knee cartilage in cadavers with dual-detector spiral CT arthrography and MR imaging.

    abstract:PURPOSE:To assess dual-detector spiral CT arthrography in the evaluation of the entire knee cartilage obtained from cadavers. MATERIALS AND METHODS:Two independent observers characterized articular cartilage in 12 cadaver knees in which MR imaging and dual-detector spiral CT arthrography were performed and compared th...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2222010597

    authors: Vande Berg BC,Lecouvet FE,Poilvache P,Jamart J,Materne R,Lengele B,Maldague B,Malghem J

    更新日期:2002-02-01 00:00:00

  • Echotexture of peripheral nerves: correlation between US and histologic findings and criteria to differentiate tendons.

    abstract:PURPOSE:To correlate the histologic structure and echotexture of peripheral nerves and verify if ultrasound (US) findings can be used to differentiate nerve from tendon. MATERIALS AND METHODS:In an in vitro study, the echotexture of normal peripheral nerves was correlated with the histologic findings. In an in vivo st...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.197.1.7568840

    authors: Silvestri E,Martinoli C,Derchi LE,Bertolotto M,Chiaramondia M,Rosenberg I

    更新日期:1995-10-01 00:00:00

  • Endorectal MR imaging in the evaluation of seminal vesicle invasion: diagnostic accuracy and multivariate feature analysis.

    abstract:PURPOSE:To retrospectively determine the accuracy of endorectal magnetic resonance (MR) imaging in demonstrating seminal vesicle invasion (SVI) and to investigate the MR imaging features that can predict SVI. MATERIALS AND METHODS:The Institutional Review Board granted exempt status for this retrospective study, with ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2383050657

    authors: Sala E,Akin O,Moskowitz CS,Eisenberg HF,Kuroiwa K,Ishill NM,Rajashanker B,Scardino PT,Hricak H

    更新日期:2006-03-01 00:00:00

  • Endoscopic ultrasonic evaluation of the prostate using a transrectal probe: prospective evaluation and acoustic characterization.

    abstract::Transrectal sonography of the normal prostate demonstrates a gland that has low-level homogeneous echoes. Benign and malignant prostatic disease causes disruption of this normal texture. A prospective study was performed to determine the ability of ultrasound to detect focal defects accurately. The specific histologic...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.149.1.6193560

    authors: Rifkin MD,Kurtz AB,Choi HY,Goldberg BB

    更新日期:1983-10-01 00:00:00

  • Waldenström macroglobulinemia: MR imaging of the spine and CT of the abdomen and pelvis.

    abstract::Twenty-three consecutive patients with Waldenström macroglobulinemia were studied with magnetic resonance (MR) imaging of the spine and computed tomography (CT) of the abdomen and pelvis. MR imaging studies included sagittal T1-weighted and gradient-recalled-echo sequences performed with and without contrast material ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.188.3.8351330

    authors: Moulopoulos LA,Dimopoulos MA,Varma DG,Manning JT,Johnston DA,Leeds NE,Libshitz HI

    更新日期:1993-09-01 00:00:00

  • Cervical carcinoma: MR imaging with an endorectal surface coil.

    abstract::Ten consecutive patients with biopsy-proved invasive cervical carcinoma underwent magnetic resonance (MR) imaging with both a standard body coil and with an endorectal surface coil. The endorectal coil provided a markedly improved signal-to-noise ratio, enabling the use of small fields of view; thus, the images had si...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.180.1.2052730

    authors: Milestone BN,Schnall MD,Lenkinski RE,Kressel HY

    更新日期:1991-07-01 00:00:00

  • Arteriography with portable DSA equipment.

    abstract::Fifty-one arteriograms were obtained outside of the radiology department with portable digital subtraction angiographic equipment. Thirty-five studies were performed in the emergency room, 12 in the operating room, and four in the intensive care unit. There was a significant decrease in the time interval from arrival ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/172.3.1023

    authors: King JN,Orrison WW,Keck GM,Demarest GB,Hinson JE,Sell JJ

    更新日期:1989-09-01 00:00:00

  • Automated Calculation of the Alberta Stroke Program Early CT Score: Feasibility and Reliability.

    abstract::Background The Alberta Stroke Program Early CT Score (ASPECTS) evaluation is a qualitative method to evaluate focal hypoattenuation at brain CT in early acute stroke. However, interobserver agreement is only moderate. Purpose To compare ASPECTS calculated by using an automatic software tool to neuroradiologist evaluat...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2019181228

    authors: Maegerlein C,Fischer J,Mönch S,Berndt M,Wunderlich S,Seifert CL,Lehm M,Boeckh-Behrens T,Zimmer C,Friedrich B

    更新日期:2019-04-01 00:00:00

  • Neodymium yttrium aluminum garnet laser treatment of hemobilia via a percutaneous biliary catheter track.

    abstract::The authors describe the use of neodymium yttrium aluminum garnet laser introduced via a percutaneous catheter track for photocoagulation of a bleeding bile duct tumor. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.148.3.6878710

    authors: Carpenter CM,Bowers JH,Luers PR,Dixon JA,Miller FJ

    更新日期:1983-09-01 00:00:00

  • Percutaneous intentional extraluminal recanalization in patients with chronic critical limb ischemia.

    abstract:PURPOSE:To review percutaneous intentional extraluminal recanalization (PIER) for treatment of patients who are poor candidates for infrainguinal arterial bypass surgery (IABS) and have arterial occlusions and chronic critical limb ischemia (CCLI). MATERIALS AND METHODS:Patients with CCLI who were poor candidates for ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2322030729

    authors: Spinosa DJ,Leung DA,Matsumoto AH,Bissonette EA,Cage D,Harthun NL,Kern JA,Angle JF,Hagspiel KD,Crosby IK,Wellons HA Jr,Tribble CG,Hartwell GD

    更新日期:2004-08-01 00:00:00

  • Rotator cuff tears: correlation of sonographic and surgical findings.

    abstract::High-resolution, real-time sonography of the rotator cuff was performed in 51 shoulders, and the results were correlated with findings obtained during subsequent surgery. Prospective sensitivity of sonography in detection of a tear was 100%; specificity, 75%; and accuracy, 92%. Retrospective estimation of tear size on...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.169.3.3055040

    authors: Hodler J,Fretz CJ,Terrier F,Gerber C

    更新日期:1988-12-01 00:00:00

  • Sonography of portosystemic venous collaterals in portal hypertension.

    abstract::Portosystemic venous collaterals were studied with sonography in 40 patients with known portal hypertension. Eight patients had technically inadequate scans, while 32 had optimal scans. Sixty groups of venous collaterals were identified. At least one collateral pathway was seen in 28 patients, for a sensitivity of 88%...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.146.1.6849040

    authors: Subramanyam BR,Balthazar EJ,Madamba MR,Raghavendra BN,Horii SC,Lefleur RS

    更新日期:1983-01-01 00:00:00

  • Brain tumors: detection with C-11 choline PET.

    abstract:PURPOSE:To evaluate the effectiveness of positron emission tomography (PET) with carbon-11 choline in brain tumor imaging. MATERIALS AND METHODS:A rat glioma cell line (C6) was incubated with C-14 choline; the time course of uptake and metabolism was determined in vitro. C-11 choline was injected intravenously in tumo...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.202.2.9015080

    authors: Shinoura N,Nishijima M,Hara T,Haisa T,Yamamoto H,Fujii K,Mitsui I,Kosaka N,Kondo T,Hara T

    更新日期:1997-02-01 00:00:00

  • Feasibility of whole-body MR with T2- and T1-weighted real-time steady-state free precession sequences during continuous table movement to depict metastases.

    abstract::The purpose of the study was to prospectively evaluate a whole-body magnetic resonance (MR) imaging protocol to help depict metastases by using unenhanced T2-weighted and contrast material-enhanced T1-weighted real-time sequences during continuous table movement. The study was conducted after approval of the local ins...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2463062017

    authors: Brauck K,Zenge MO,Vogt FM,Quick HH,Stock F,Trarbach T,Ladd ME,Barkhausen J

    更新日期:2008-03-01 00:00:00

  • Science to practice: will contrast agents for molecular imaging of angiogenesis help overcome the limitations of functional vascular imaging?

    abstract::Schmieder and colleagues introduced a new molecular magnetic resonance (MR) probe with a promising lipophilic gadolinium chelate complex that provides high relaxivity. Results of in vivo experiments clearly demonstrate the excellence of the probe for longitudinally monitoring α(v)β(3) integrin expression in tumors. In...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.13131094

    authors: Kiessling F

    更新日期:2013-08-01 00:00:00

  • Centrilobular lesions of the lung: demonstration by high-resolution CT and pathologic correlation.

    abstract::To determine the value of high-resolution computed tomography (HRCT) in the diagnosis of diffuse pulmonary diseases, a direct HRCT-pathologic correlative study was performed using four inflated and fixed lungs from autopsy. In normal lungs, the smallest pulmonary artery resolved by HRCT was 200 microns in diameter; th...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.161.3.3786710

    authors: Murata K,Itoh H,Todo G,Kanaoka M,Noma S,Itoh T,Furuta M,Asamoto H,Torizuka K

    更新日期:1986-12-01 00:00:00

  • HLA-B27 associated arthropathies.

    abstract::The association between histo-compatibility antigens and disease is reviewed, in particular that between HLA-B27 and spondylitic disorders, i.e., ankylosing spondylitis, Reiter's arthritis, psoriatic arthritis, and ankylosing hyperostosis. We determined whether the presence of HLA-B27 predicted specific radiographic f...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/126.2.289

    authors: Schumacher TM,Genant HK,Kellet MJ,Mall JC,Fye KH

    更新日期:1978-02-01 00:00:00

  • Diffuse lung disease: diagnostic accuracy of CT in patients undergoing surgical biopsy of the lung.

    abstract:PURPOSE:To determine if there is a subset of patients undergoing surgical biopsy for diffuse lung disease in whom accurate diagnosis can be made with computed tomography (CT) only. MATERIALS AND METHODS:Two chest radiologists retrospectively reviewed the CT scans of 85 patients in whom surgical biopsy for diffuse lung...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.205.1.9314990

    authors: Swensen SJ,Aughenbaugh GL,Myers JL

    更新日期:1997-10-01 00:00:00

  • Ectopic pregnancy: evolution after treatment with transvaginal methotrexate.

    abstract::A prospective study was performed with 25 patients with ectopic pregnancies (EPs) who underwent treatment with transvaginal administration of methotrexate. Nineteen patients (76%) had positive responses to this treatment, and six (24%) had to undergo surgery: five because of increasing abdominal pain and one because o...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.185.3.1279740

    authors: Atri M,Bret PM,Tulandi T,Senterman MK

    更新日期:1992-12-01 00:00:00

  • Minimizing central bile duct injury during radiofrequency ablation: use of intraductal chilled saline perfusion--initial observations from a study in pigs.

    abstract:PURPOSE:To determine whether intraductal perfusion with chilled saline reduces thermal injury to bile ducts during radiofrequency (RF) ablation. MATERIALS AND METHODS:In swine, anesthesia was induced and the common bile duct was surgically cannulated with a pediatric feeding tube. RF thermal lesions were created adjac...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2321030210

    authors: Raman SS,Aziz D,Chang X,Ye M,Sayre J,Lassman C,Lu DS

    更新日期:2004-07-01 00:00:00

  • Focal Epilepsy: MR Imaging of Nonhemodynamic Field Effects by Using a Phase-cycled Stimulus-induced Rotary Saturation Approach with Spin-Lock Preparation.

    abstract::Purpose To investigate whether nonhemodynamic resonant saturation effects can be detected in patients with focal epilepsy by using a phase-cycled stimulus-induced rotary saturation (PC-SIRS) approach with spin-lock (SL) preparation and whether they colocalize with the seizure onset zone and surface interictal epilepti...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2016150368

    authors: Kiefer C,Abela E,Schindler K,Wiest R

    更新日期:2016-07-01 00:00:00

  • Paget disease with contraction of long bones.

    abstract::The evolution of Paget disease characterized both by expansion and subsequent contraction of the long bones of the ipsilateral upper extremity over a 10-year period is described. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.159.2.3961180

    authors: Lander PH,Hadjipavlou AG

    更新日期:1986-05-01 00:00:00

  • High-Performance Automated Anterior Circulation CT Angiographic Clot Detection in Acute Stroke: A Multireader Comparison.

    abstract::Background Identification of large vessel occlusion (LVO) is critical to the management of acute ischemic stroke and prerequisite to endovascular therapy in recent trials. Increasing volumes and data complexity compel the development of fast, reliable, and automated tools for LVO detection to facilitate acute imaging ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2021202734

    authors: Dehkharghani S,Lansberg M,Venkatsubramanian C,Cereda C,Lima F,Coelho H,Rocha F,Qureshi A,Haerian H,Mont'Alverne F,Copeland K,Heit J

    更新日期:2021-01-12 00:00:00

  • Pure ductal carcinoma in situ: kinetic and morphologic MR characteristics compared with mammographic appearance and nuclear grade.

    abstract:PURPOSE:To retrospectively compare the kinetic and morphologic characteristics of pure ductal carcinoma in situ (DCIS) lesions depicted on dynamic contrast material-enhanced magnetic resonance (MR) images with the nuclear grade and conventional mammographic appearance of these lesions. MATERIALS AND METHODS:This HIPAA...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2453062061

    authors: Jansen SA,Newstead GM,Abe H,Shimauchi A,Schmidt RA,Karczmar GS

    更新日期:2007-12-01 00:00:00

  • Small-bowel disease: comparison of MR enteroclysis images with conventional enteroclysis and surgical findings.

    abstract:PURPOSE:To investigate if magnetic resonance (MR) enteroclysis can be performed routinely and to compare MR enteroclysis findings with those of conventional enteroclysis or surgery. MATERIALS AND METHODS:MR enteroclysis was prospectively performed in 30 patients with symptoms of inflammatory bowel disease or small-bow...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.215.3.r00jn12717

    authors: Umschaden HW,Szolar D,Gasser J,Umschaden M,Haselbach H

    更新日期:2000-06-01 00:00:00