Abstract:
:Background Identification of large vessel occlusion (LVO) is critical to the management of acute ischemic stroke and prerequisite to endovascular therapy in recent trials. Increasing volumes and data complexity compel the development of fast, reliable, and automated tools for LVO detection to facilitate acute imaging triage. Purpose To investigate the performance of an anterior circulation LVO detection platform in a large mixed sample of individuals with and without LVO at cerebrovascular CT angiography (CTA). Materials and Methods In this retrospective analysis, CTA data from recent cerebrovascular trials (CRISP [ClinicalTrials.gov NCT01622517] and DASH) were enriched with local repositories from 11 worldwide sites to balance demographic and technical variables in LVO-positive and LVO-negative examinations. CTA findings were reviewed independently by two neuroradiologists from different institutions for intracranial internal carotid artery (ICA) or middle cerebral artery (MCA) M1 LVO; these observers were blinded to all clinical variables and outcomes. An automated analysis platform was developed and tested for prediction of LVO presence and location relative to reader consensus. Discordance between readers with respect to LVO presence or location was adjudicated by a blinded tertiary reader at a third institution. Sensitivity, specificity, and receiver operating characteristics were assessed by an independent statistician, and subgroup analyses were conducted. Prespecified performance thresholds were set at a lower bound of the 95% CI of sensitivity and specificity of 0.8 or greater at mean times to notification of less than 3.5 minutes. Results A total of 217 study participants (mean age, 64 years ± 16 [standard deviation]; 116 men; 109 with positive findings of LVO) were evaluated. Prespecified performance thresholds were exceeded (sensitivity, 105 of 109 [96%; 95% CI: 91, 99]; specificity, 106 of 108 [98%; 95% CI: 94, 100]). Sensitivity and specificity estimates across age, sex, location, and vendor subgroups exceeded 90%. The area under the receiver operating characteristic curve was 99% (95% CI: 97, 100). Mean processing and notification time was 3 minutes 18 seconds. Conclusion The results confirm the feasibility of fast automated high-performance detection of intracranial internal carotid artery and middle cerebral artery M1 occlusions. © RSNA, 2021 See also the editorial by Kloska in this issue.
journal_name
Radiologyjournal_title
Radiologyauthors
Dehkharghani S,Lansberg M,Venkatsubramanian C,Cereda C,Lima F,Coelho H,Rocha F,Qureshi A,Haerian H,Mont'Alverne F,Copeland K,Heit Jdoi
10.1148/radiol.2021202734subject
Has Abstractpub_date
2021-01-12 00:00:00pages
202734eissn
0033-8419issn
1527-1315pub_type
杂志文章相关文献
RADIOLOGY文献大全abstract::The anatomy of the posterior cerebral artery (PCA) and its branches is described. On the vertebral angiogram, displacement of these vessels is a sign of corresponding displacement of the temporal horn, which in turn is an indication of a mass involving the temporal lobe, diencephalon, or midbrain. Specific angiographi...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/128.2.387
更新日期:1978-08-01 00:00:00
abstract:PURPOSE:To determine whether fetal growth measured at serial ultrasonographic (US) examinations can predict neonatal morbidity, independent of whether gestational age is known. MATERIALS AND METHODS:Women (n = 321) who had singleton pregnancies and underwent two or more second- or third-trimester obstetric US examinat...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2231010876
更新日期:2002-04-01 00:00:00
abstract::Radiologists are frequently called upon to perform percutaneous biopsy. Selection of the proper needle is becoming more complex as the number of types increases and reports of better results with certain needles proliferate. The authors evaluated a wide variety of needles of different caliber, cutting tip, and bevel. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.148.3.6878680
更新日期:1983-09-01 00:00:00
abstract::A fluoroscopic system was modified to achieve a 95-98% reduction in radiation exposure and dosage to patients compared with other systems that reduce fluoroscopic radiation dosage. This reduction was accomplished by custom selection of a high conversion-factor, triplemode image intensifier; custom design of a variable...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.153.1.6473790
更新日期:1984-10-01 00:00:00
abstract::The addition of polytomography considerably increases the sensitivity of pneumoencephalography. The chiasmatic area lends itself particularly well to investigation by polytomoencephalography. In a series of 28 patients, the transverse dimension of the optic chiasm ranged from 4 to 20 mm, with a mean of 18 mm. The post...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/114.3.629
更新日期:1975-03-01 00:00:00
abstract:PURPOSE:To evaluate two-phase helical computed tomography (CT) in the characterization of salivary gland tumors. MATERIALS AND METHODS:Sixty-four patients with major salivary gland tumors underwent two-phase helical CT. The histopathologic diagnosis was obtained by means of surgical resection or biopsy in all patients...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.214.1.r00ja05231
更新日期:2000-01-01 00:00:00
abstract::A prospective, comparative study was made of the efficacy of technetium-99m pyrophosphate (Tc PYP) and technetium-99m methylene diphosphonate (Tc MDP) in detecting soft-tissue amyloidosis. Tc PYP and Tc MDP scans were obtained within ten-day intervals in seven patients with histologically proven amyloidosis. Tc PYP wa...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.148.1.6304810
更新日期:1983-07-01 00:00:00
abstract:PURPOSE:To compare the accuracies of whole-body 2-[fluorine 18]fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) and conventional imaging (thoracic computed tomography [CT], bone scintigraphy, and brain CT or magnetic resonance [MR] imaging) in staging bronchogenic carcinoma. MATERIALS AND METHODS:With...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.212.3.r99se21803
更新日期:1999-09-01 00:00:00
abstract::The CT findings in 16 patients with histologically proved primary central nervous system (CNS) reticulum cell sarcoma (RCS) showed this malignancy to have predilection for the basal ganglia and thalamus, the periventricular white matter, the corpus callosum, and the vermis cerebelli. In 43% of patients with untreated ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/130.1.165
更新日期:1979-01-01 00:00:00
abstract:PURPOSE:To prospectively assess the oxygenation state of renal transplants and determine the feasibility of using blood oxygen level-dependent (BOLD) magnetic resonance (MR) imaging to differentiate between acute tubular necrosis (ATN), acute rejection, and normal function. MATERIALS AND METHODS:This HIPAA-compliant s...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2363041080
更新日期:2005-09-01 00:00:00
abstract:PURPOSE:To evaluate the potential of quantitative susceptibility (QS) and R2* mapping as surrogate biomarkers of clinically relevant, age-adjusted demyelination and iron deposition in multiple sclerosis (MS). MATERIALS AND METHODS:All study participants gave written informed consent, and the study was approved by the ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.14132475
更新日期:2014-09-01 00:00:00
abstract::Radiological abnormalities of the ribs are reported in 5 newborn infants with myotonic dystrophy. In all 5, the ribs appeared very thin, in contrast to the normal appearance of the rest of the skeleton. This slenderness, which is important for diagnosis and prognosis, seems to be caused by hypotonia of the intercostal...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/127.3.747
更新日期:1978-06-01 00:00:00
abstract:PURPOSE:To identify opportunities for improving patient-centered communication about diagnostic imaging tests that involve the use of radiation in a cancer care setting. MATERIALS AND METHODS:Institutional review board approval and informed consent were obtained for this HIPAA-compliant study. Patient knowledge, infor...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.15132905
更新日期:2015-05-01 00:00:00
abstract::The measurement of supine pedal venous pressure as a screening test for deep venous thrombosis is re-evaluated. In 83 extremities studied in 50 patients, the false-positive rate was 62%, the false-negative rate 8%. Chronic venous disease, whatever its etiology but particularly in association with the post-phlebitis sy...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/131.1.75
更新日期:1979-04-01 00:00:00
abstract::Twenty patients with multiple or recurrent superficial head and facial cancer were treated with low-megavoltage electron-beam therapy, using a readily adaptable polystyrene shield assembly with interchangeable collimators. Patient set-up times were reduced, treatment was simplified, and flexibility of therapy was achi...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/15.3.695
更新日期:1975-06-01 00:00:00
abstract::Background Patients with wrist trauma and negative findings on radiographs often undergo additional MRI examinations to assess for radiographically occult fractures. Dual-energy CT may be more readily available than MRI in some settings. Purpose To evaluate the diagnostic test accuracy of dual-energy CT in helping det...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2020192701
更新日期:2020-09-01 00:00:00
abstract:PURPOSE:To analyze sonographic imaging features of renal collecting systems, ureters, and bladder in 32 children after endoscopic treatment of vesicoureteral reflux with autologous chondrocytes and to determine whether any features are associated with persistent reflux. MATERIALS AND METHODS:Sonograms obtained at mean...
journal_title:Radiology
pub_type: 临床试验,杂志文章
doi:10.1148/radiol.2322030551
更新日期:2004-08-01 00:00:00
abstract::Invasive coronary angiography (ICA) with measurement of fractional flow reserve (FFR) by means of a pressure wire technique is the established reference standard for the functional assessment of coronary artery disease (CAD) ( 1 , 2 ). Coronary computed tomographic (CT) angiography has emerged as a noninvasive method ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2017162641
更新日期:2017-10-01 00:00:00
abstract:PURPOSE:To evaluate the accuracy of preoperative computed tomography (CT) in predicting the location and type of ductal involvement and malignant transformation in intraductal papillary mucinous (IPM) pancreatic tumors and to determine the predictive factors for malignancy at CT. MATERIALS AND METHODS:The helical CT s...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.217.3.r00dc24757
更新日期:2000-12-01 00:00:00
abstract:PURPOSE:To prospectively evaluate fluorine 18 ((18)F) 2-fluoropropionyl-labeled PEGylated dimeric arginine-glycine-aspartic acid (RGD) peptide (PEG3-E[c{RGDyk}]2) (FPPRGD2) positron emission tomography (PET) in patients with glioblastoma multiforme (GBM). MATERIALS AND METHODS:The institutional review board approved t...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2015141550
更新日期:2015-11-01 00:00:00
abstract:PURPOSE:To study the vascular and biliary liver anatomy and its relevance to the creation of a transjugular intrahepatic portosystemic shunt (TIPS). MATERIALS AND METHODS:Acrylic casts of 25 normal human livers (necropsy specimens) were obtained. The anatomy of the hepatic veins, portal vein, hepatic artery, and bile ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.191.3.8184050
更新日期:1994-06-01 00:00:00
abstract:PURPOSE:To compare conventional and Doppler ultrasound (US) with clinical and biopsy parameters used to assess disease activity and outcome in lupus nephritis and to assess the predictive value of US. MATERIALS AND METHODS:Thirty-four patients with lupus nephritis prospectively underwent laboratory and US analysis at ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.203.1.9122420
更新日期:1997-04-01 00:00:00
abstract:PURPOSE:To prospectively determine the cellular iron uptake by using R2 and R2* mapping with multiecho readout gradient-echo and spin-echo sequences. MATERIALS AND METHODS:All experiments were approved by the institutional animal care committee. Lung carcinoma cells were lipofected with superparamagnetic iron oxides (...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2451061345
更新日期:2007-11-01 00:00:00
abstract:PURPOSE:To compare changes in urinary viscosity in the renal tubules following administration of a high-viscosity iso-osmolar contrast agent (iodixanol) to that observed following administration of a less viscous, higher osmolar contrast agent (iopromide) in anesthetized rats. MATERIALS AND METHODS:A total of 43 rats ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.10091485
更新日期:2010-08-01 00:00:00
abstract::Background Increased cerebral signal intensity (SI) has been reported in patients undergoing MRI with gadolinium-based contrast agents (GBCAs). Published data on gadobenate dimeglumine have been somewhat contradictory. Purpose To evaluate the relationship between dosage of gadobenate dimeglumine and SI change at MRI f...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2020190246
更新日期:2020-07-01 00:00:00
abstract::This report is to complement the original Fleischner Society recommendations for incidentally detected solid nodules by proposing a set of recommendations specifically aimed at subsolid nodules. The development of a standardized approach to the interpretation and management of subsolid nodules remains critically impor...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.12120628
更新日期:2013-01-01 00:00:00
abstract::A single step wedge imaging technique is described for the proper evaluation of light fog in radiographic darkrooms. Tests indicate that this technique is a more sensitive indicator of light fog than the conventional technique utilizing unexposed film. It is recommended that fog tests be carried out in radiographic da...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/115.1.225
更新日期:1975-04-01 00:00:00
abstract:PURPOSE:To evaluate the potential of xenon ventilation computed tomography (CT) in the quantitative and visual analysis of chronic obstructive pulmonary disease (COPD). MATERIALS AND METHODS:This study was approved by the institutional review board. After informed consent was obtained, 32 patients with COPD underwent ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.10091502
更新日期:2010-09-01 00:00:00
abstract::A double-blind clinical trial was performed in 1,000 consecutive patients to compare the safety and efficacy of intravenously administered nonionic (iohexol) and ionic (metrizoate) urographic contrast media. The patients ranged in age from 10 to 80 years. The incidence of mild to moderate adverse effects was 7.7% with...
journal_title:Radiology
pub_type: 临床试验,杂志文章
doi:10.1148/radiology.167.3.3283830
更新日期:1988-06-01 00:00:00
abstract::Percutaneous cholecystostomy was performed in 36 patients, of whom 22 patients with acute cholecystitis had decompression of the gallbladder and 14 patients with common duct obstruction had biliary decompression through the gallbladder. In almost all cases of acute cholecystitis, percutaneous cholecystostomy quickly c...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.152.2.6739800
更新日期:1984-08-01 00:00:00