Method for measuring three-dimensional motion with tagged MR imaging.

Abstract:

:Recent methods of magnetic resonance imaging involve the placement of a grid of planes of saturation over the imaging plane; distortion of the grid corresponds to tissue displacement in two dimensions. An extension to this method that allows measurement of motion in the third dimension involves a second acquisition that tilts the grid, allowing analysis of motion normal to the imaging plane. A rotating phantom was used to verify the accuracy of the motion measurements, and the technique was applied to the heart wall and skeletal muscle. Phantom results show that the measure of z motion can be as accurate as that of x and y motion. Three-dimensional displacements of heart-wall and skeletal muscle are shown. With an accurate measure of three-dimensional motion, more complete analysis of heart-wall motion and contraction is possible.

journal_name

Radiology

journal_title

Radiology

authors

Pipe JG,Boes JL,Chenevert TL

doi

10.1148/radiology.181.2.1924810

subject

Has Abstract

pub_date

1991-11-01 00:00:00

pages

591-5

issue

2

eissn

0033-8419

issn

1527-1315

journal_volume

181

pub_type

杂志文章
  • Stereotaxic fine-needle aspiration of low-suspicion, nonpalpable breast nodules: valid alternative to follow-up mammography.

    abstract::Seventy "low-suspicion," nonpalpable solid breast nodules were evaluated with stereotaxic fine-needle aspiration with cytologic analysis as an alternative to follow-up mammography. Sonography was performed in all cases to determine the solid nature of the nodules. Eight cysts were incorrectly classified with sonograph...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.183.3.1584910

    authors: Franquet T,Cozcolluela R,De Miguel C

    更新日期:1992-06-01 00:00:00

  • Dose-time fractionation study in patients with mycosis fungoides and lymphoma cutis.

    abstract::Single and multiple dose-time fractionation schemes were investigated in patients with mycosis fungoides and lymphoma cutis. The single dose response shows that the disease-free interval is dose dependent. Remission rates are similar when the same total dose is given in either single treatments or multiple daily fract...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/119.2.439

    authors: Kim JH,Nisce LZ,D'Anglo GJ

    更新日期:1976-05-01 00:00:00

  • Focal-spot measurement: comparison of slit, pinhole, and star resolution pattern techniques.

    abstract::The National Electrical Manufacturers Association (NEMA) has established a new standard for x-ray tube focal-spot measurements using a focal-spot camera with a slit instead of a pinhole. Measurements from the slit focal-spot camera are compared and star resolution pattern techniques for 50 focal spots. In addition, me...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.165.1.3628780

    authors: Everson JD,Gray JE

    更新日期:1987-10-01 00:00:00

  • Diffusion-tensor MR imaging and tractography: exploring brain microstructure and connectivity.

    abstract::Diffusion magnetic resonance (MR) imaging is evolving into a potent tool in the examination of the central nervous system. Although it is often used for the detection of acute ischemia, evaluation of directionality in a diffusion measurement can be useful in white matter, which demonstrates strong diffusion anisotropy...

    journal_title:Radiology

    pub_type: 杂志文章,评审

    doi:10.1148/radiol.2452060445

    authors: Nucifora PG,Verma R,Lee SK,Melhem ER

    更新日期:2007-11-01 00:00:00

  • Clinically serious abnormalities found incidentally at MR imaging of the brain: data from the Cardiovascular Health Study.

    abstract:PURPOSE:To determine the prevalence of clinically serious findings unrelated to stroke on cranial magnetic resonance (MR) images in a population of community-dwelling elderly people. MATERIALS AND METHODS:Neuroradiologists reviewed MR images of 3,672 people aged 65 years and older who were enrolled in a longitudinal, ...

    journal_title:Radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1148/radiology.202.1.8988190

    authors: Yue NC,Longstreth WT Jr,Elster AD,Jungreis CA,O'Leary DH,Poirier VC

    更新日期:1997-01-01 00:00:00

  • Disease activity in osteomyelitis: role of radiography.

    abstract::To determine the impact of radiographic findings on the interpretation of bone and gallium scans of patients with active osteomyelitis, the authors reviewed the medical records and radiologic examinations of 104 patients. The only diagnostic finding of active disease on radiographs was the presence of a sequestrum (th...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.165.3.3685360

    authors: Tumeh SS,Aliabadi P,Weissman BN,McNeil BJ

    更新日期:1987-12-01 00:00:00

  • Thin-section CT of the lung: does electrocardiographic triggering influence diagnosis?

    abstract:PURPOSE:To determine the impact of prospective electrocardiographic (ECG) triggering on image quality and diagnostic outcome of thin-section computed tomography (CT) of the lung. MATERIALS AND METHODS:Forty-five consecutive patients referred for thin-section CT of the lung were examined with prospectively ECG-triggere...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2292021114

    authors: Boehm T,Willmann JK,Hilfiker PR,Weishaupt D,Seifert B,Crook DW,Marincek B,Wildermuth S

    更新日期:2003-11-01 00:00:00

  • Lower-extremity Arterial Thrombosis Associated with COVID-19 Is Characterized by Greater Thrombus Burden and Increased Rate of Amputation and Death.

    abstract::Background During the peak of the coronavirus disease 2019 (COVID-19) pandemic, the authors noted an increase in positive lower-extremity CT angiography examinations in patients who presented with leg ischemia. The goal of this study was to determine whether lower-extremity arterial thrombosis was associated with COVI...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2020202348

    authors: Goldman IA,Ye K,Scheinfeld MH

    更新日期:2020-11-01 00:00:00

  • B-cell non-Hodgkin lymphoma: PET/CT evaluation after 90Y-ibritumomab tiuxetan radioimmunotherapy--initial experience.

    abstract:PURPOSE:To retrospectively compare fusion fluorine 18 fluorodeoxyglucose (FDG) positron emission tomographic (PET)/computed tomographic (CT) imaging with CT imaging alone in the evaluation of yttrium 90 ((90)Y)-ibritumomab tiuxetan radioimmunotherapy treatment of B-cell non-Hodgkin lymphoma. MATERIALS AND METHODS:This...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2463060588

    authors: Ulaner GA,Colletti PM,Conti PS

    更新日期:2008-03-01 00:00:00

  • Iliac arterial occlusive disease: cost-effectiveness analysis of stent placement versus percutaneous transluminal angioplasty. Dutch Iliac Stent Trial Study Group.

    abstract:PURPOSE:To evaluate the relative benefits and cost-effectiveness of treating iliac arterial occlusive disease with various interventions. MATERIALS AND METHODS:Cost-effectiveness was analyzed in a hypothetical cohort of patients with intermittent claudication caused by an iliac arterial stenosis. Primary stent placeme...

    journal_title:Radiology

    pub_type: 杂志文章,meta分析

    doi:10.1148/radiology.208.3.9722840

    authors: Bosch JL,Tetteroo E,Mali WP,Hunink MG

    更新日期:1998-09-01 00:00:00

  • Resolution of intracranial calcifications in infants with treated congenital toxoplasmosis.

    abstract:PURPOSE:To determine the natural history of intracranial calcifications in infants with treated congenital toxoplasmosis. MATERIALS AND METHODS:Between January 1982 and March 1994, cranial computed tomography was performed in 56 infants with treated congenital toxoplasmosis when they were newborns and approximately 1 ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.199.2.8668790

    authors: Patel DV,Holfels EM,Vogel NP,Boyer KM,Mets MB,Swisher CN,Roizen NJ,Stein LK,Stein MA,Hopkins J,Withers SE,Mack DG,Luciano RA,Meier P,Remington JS,McLeod RL

    更新日期:1996-05-01 00:00:00

  • A Simplified Whole-Organ CT Perfusion Technique with Biphasic Acquisition: Preliminary Investigation of Accuracy and Protocol Feasibility in Kidneys.

    abstract:PURPOSE:To determine the feasibility and accuracy of a protocol for calculating whole-organ renal perfusion (renal blood flow [RBF]) and regional perfusion on the basis of biphasic computed tomography (CT), with concurrent dynamic contrast material-enhanced (DCE) CT perfusion serving as the reference standard. MATERIA...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015142757

    authors: Yuan X,Zhang J,Quan C,Tian Y,Li H,Ao G

    更新日期:2016-04-01 00:00:00

  • Adhesive capsulitis of the wrist: arthrographic diagnosis.

    abstract::Persistent pain and decreased range of motion are disabling complications of wrist trauma. Between 1978 and 1986, in ten patients with persistent pain following trauma, arthrography depicted changes characteristic of adhesive capsulitis. Adhesive capsulitis has been described in the shoulder, hip, and ankle, but littl...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.167.1.3347720

    authors: Maloney MD,Sauser DD,Hanson EC,Wood VE,Thiel AE

    更新日期:1988-04-01 00:00:00

  • Cerebral perfusion CT: technique and clinical applications.

    abstract::Perfusion computed tomography (CT) is a relatively new technique that allows rapid qualitative and quantitative evaluation of cerebral perfusion by generating maps of cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT). The technique is based on the central volume principle (CBF = CBV/M...

    journal_title:Radiology

    pub_type: 杂志文章,评审

    doi:10.1148/radiol.2313021488

    authors: Hoeffner EG,Case I,Jain R,Gujar SK,Shah GV,Deveikis JP,Carlos RC,Thompson BG,Harrigan MR,Mukherji SK

    更新日期:2004-06-01 00:00:00

  • Silicone breast implant ruptures in an animal model: comparison of mammography, MR imaging, US, and CT.

    abstract:PURPOSE:To determine the most accurate imaging modality for detection of silicone implant ruptures. MATERIALS AND METHODS:Forty single-lumen silicone implants were surgically placed in 20 rabbits. Each rabbit received one intact and one ruptured implant and was examined with mammography, magnetic resonance (MR) imagin...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.190.1.8259410

    authors: Gorczyca DP,DeBruhl ND,Ahn CY,Hoyt A,Sayre JW,Nudell P,McCombs M,Shaw WW,Bassett LW

    更新日期:1994-01-01 00:00:00

  • Cervical carcinoma: optimized local staging with intravaginal contrast-enhanced MR imaging--preliminary results.

    abstract::Ten patients suspected of having cervical carcinoma underwent magnetic resonance (MR) imaging before and after opacification of the vagina with a mixture of barium, water, and maltodextrin/calcium lactate. Use of vaginal contrast medium resulted in improved visualization of the vaginal wall, lumen, and fornices in all...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章

    doi:10.1148/radiology.213.2.r99oc23608

    authors: Van Hoe L,Vanbeckevoort D,Oyen R,Itzlinger U,Vergote I

    更新日期:1999-11-01 00:00:00

  • Human hippocampal subfields in young adults at 7.0 T: feasibility of imaging.

    abstract:PURPOSE:To establish an imaging approach to visualize the 100-microm-thick hippocampal neuron-generating dentate granule cell layer (DGCL) consistently within a clinically feasible magnetic resonance (MR) imaging duration and to assess its sensitivity by quantifying the likelihood that it will be detected in healthy yo...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.09090897

    authors: Prudent V,Kumar A,Liu S,Wiggins G,Malaspina D,Gonen O

    更新日期:2010-03-01 00:00:00

  • Variations in acromial ossification simulating infant abuse in victims of sudden infant death syndrome.

    abstract::A variation in ossification of the acromial process of the scapula is described. Postmortem radiographs, obtained in 78 infants who died of sudden infant death syndrome, showed an ossific opacity adjacent to the acromial process in 10 infants (13%). This finding was noted bilaterally in six patients and unilaterally i...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.180.1.2052690

    authors: Kleinman PK,Spevak MR

    更新日期:1991-07-01 00:00:00

  • Low back pain: influence of early MR imaging or CT on treatment and outcome--multicenter randomized trial.

    abstract:PURPOSE:To establish whether early use of magnetic resonance (MR) imaging or computed tomography (CT) influences treatment and outcome of patients with low back pain (LBP) and whether it is cost-effective. MATERIALS AND METHODS:In a multicenter randomized study, two imaging policies for LBP were compared in 782 partic...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1148/radiol.2312030886

    authors: Gilbert FJ,Grant AM,Gillan MG,Vale LD,Campbell MK,Scott NW,Knight DJ,Wardlaw D,Scottish Back Trial Group.

    更新日期:2004-05-01 00:00:00

  • Deep venous thrombosis: longitudinal study with duplex US.

    abstract::Forty-nine patients with deep venous thrombosis (DVT) of the lower limb were studied with repeated duplex ultrasound (US) for at least 1 year or until the vein became normal at US. Standard anticoagulant therapy was given for 3 months. In 36 patients, the veins became normal within 1 year. The likelihood of normalizat...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.179.1.2006290

    authors: Mantoni M

    更新日期:1991-04-01 00:00:00

  • US depiction of partial-thickness tear of the rotator cuff.

    abstract:PURPOSE:To test previously defined ultrasound (US) criteria for identification of partial-thickness tears of the rotator cuff. MATERIALS AND METHODS:Before shoulder arthroscopy, 52 patients with shoulder pain for more than 3 months were examined with a 7.5-MHz commercially available linear-array transducer and a stand...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.197.2.7480690

    authors: van Holsbeeck MT,Kolowich PA,Eyler WR,Craig JG,Shirazi KK,Habra GK,Vanderschueren GM,Bouffard JA

    更新日期:1995-11-01 00:00:00

  • Acute lung injury: effects of prone positioning on cephalocaudal distribution of lung inflation--CT assessment in dogs.

    abstract:PURPOSE:To quantify cephalocaudal gradient of lung inflation in acute lung injury in a dog model in prone versus supine position. MATERIALS AND METHODS:Experiments were performed in accordance with Guide for the Care and Use of Laboratory Animals, as approved by National Research Council (National Institutes of Health...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2341030992

    authors: Lee HJ,Im JG,Goo JM,Kim YI,Lee MW,Ryu HG,Bahk JH,Yoo CG

    更新日期:2005-01-01 00:00:00

  • The significance of residual disease after external irradiation of squamous-cell carcinoma of the oropharynx.

    abstract::366 patients with squamous-cell carcinoma of the oropharynx treated by external irradiation were studied to see whether residual disease at the end of treatment influences control. The frequency of recurrence was found to be significantly greater when residual disease was present. When the total dose was determined by...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/124.2.493

    authors: Barkley HT,Fletcher GH

    更新日期:1977-08-01 00:00:00

  • Application of duplex US for characterization of endoleaks in abdominal aortic stent-grafts: report of five cases.

    abstract::Endoleaks were detected with helical computed tomographic (CT) angiography in five patients after placement of an aortobiliac stent-graft. The leaks were subsequently evaluated with duplex ultrasonography (US) and, in four patients, with conventional aortography as well. CT angiography revealed a total of seven endole...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2253011806

    authors: Greenfield AL,Halpern EJ,Bonn J,Wechsler RJ,Kahn MB

    更新日期:2002-12-01 00:00:00

  • Detection of simulated chest lesions by using soft-copy reading: comparison of an amorphous silicon flat-panel-detector system and a storage-phosphor system.

    abstract:PURPOSE:To compare observer performance by using soft-copy images produced by an amorphous silicon flat-panel-detector system and a storage-phosphor system for the detection of simulated chest lesions. MATERIALS AND METHODS:To test the diagnostic performance of these two systems, four types of simulated lesions (nodul...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2241011441

    authors: Goo JM,Im JG,Lee HJ,Chung MJ,Seo JB,Kim HY,Lee YJ,Kang JW,Kim JH

    更新日期:2002-07-01 00:00:00

  • Scanner conformity in CT densitometry of the lungs.

    abstract:PURPOSE:To quantify inter- and intrascanner conformity in computed tomographic (CT) densitometry of the lungs. MATERIALS AND METHODS:With six scanners from four manufacturers, a lung densitometry protocol with several variations was applied for performance comparison. Phantoms included water, air, and a humanoid thora...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.197.3.7480750

    authors: Kemerink GJ,Lamers RJ,Thelissen GR,van Engelshoven JM

    更新日期:1995-12-01 00:00:00

  • Presurgical evaluation of the motor hand area with functional MR imaging in patients with tumors and dysplastic lesions.

    abstract:PURPOSE:To test an optimized functional magnetic resonance (MR) imaging procedure to depict the motor hand representation area (HRA) in patients with epilepsy lesions near the central sulcus. MATERIALS AND METHODS:Fast low-angle shot MR imaging was performed with an oblique single-section imaging technique in eight co...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.210.2.r99ja31529

    authors: Achten E,Jackson GD,Cameron JA,Abbott DF,Stella DL,Fabinyi GC

    更新日期:1999-02-01 00:00:00

  • New tools of the trade.

    abstract::The author reviews the regulatory process through which new cardiovascular interventional devices reach the hands of the interventional radiologist and the cardiologist. The marketing mechanisms are outlined, as are the data requirements. The reader is taken step-by-step from device investigation conducted under an ap...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章

    doi:10.1148/radiology.174.3.174-3-923

    authors: Reamer LA

    更新日期:1990-03-01 00:00:00

  • CT fluoroscopy--guided interventional procedures: techniques and radiation dose to radiologists.

    abstract:PURPOSE:To determine the radiation dose to radiologists who perform computed tomographic (CT) fluoroscopic interventional procedures by using a quick-check method and a low-milliampere technique. MATERIALS AND METHODS:Two hundred twenty CT fluoroscopy--guided interventional procedures were performed in 189 patients. P...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.220.1.r01jl29161

    authors: Paulson EK,Sheafor DH,Enterline DS,McAdams HP,Yoshizumi TT

    更新日期:2001-07-01 00:00:00

  • Cervical carcinoma: determination of recurrent tumor extent versus radiation changes with MR imaging.

    abstract:PURPOSE:To evaluate the effectiveness of magnetic resonance (MR) imaging for assessment of the present and extent of tumor recurrence as determined with pathologic and surgical findings. MATERIALS AND METHODS:MR findings were retrospectively examined in 37 patients with a history of cervical carcinoma. Inter- and intr...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.194.1.7997540

    authors: Weber TM,Sostman HD,Spritzer CE,Ballard RL,Meyer GA,Clark-Pearson DL,Soper JT

    更新日期:1995-01-01 00:00:00