Abstract:
PURPOSE:To retrospectively determine the accuracy of endorectal magnetic resonance (MR) imaging in demonstrating seminal vesicle invasion (SVI) and to investigate the MR imaging features that can predict SVI. MATERIALS AND METHODS:The Institutional Review Board granted exempt status for this retrospective study, with waiver of informed consent; patient data were collected and handled in accordance with HIPAA regulations. Fifty-one men (age range, 44-73 years) with SVI and 303 men (age range, 40-76 years) without SVI who underwent endorectal MR imaging before radical prostatectomy between January 2000 and October 2004 were included in the study. Endorectal MR images were retrospectively and independently analyzed by two radiologists for SVI, tumor at prostate base, extracapsular extension, and other features considered indicative of SVI. Areas under the receiver operating characteristic curves (AUCs) were used to assess the accuracy of detecting SVI at endorectal MR imaging. A multiple logistic regression was used to explore the combinations of MR imaging features that might facilitate the detection of SVI. RESULTS:Readers 1 and 2 had an AUC of 0.93 and 0.81, respectively, for the detection of SVI. For both readers, the features that had the highest sensitivity and specificity were low signal intensity within the seminal vesicle and lack of preservation of seminal vesicle architecture. At multiple regression analysis, tumor at the prostate base that extended beyond the capsule and low signal intensity within a seminal vesicle that has lost its normal architecture were highly predictive of SVI. CONCLUSION:Endorectal MR imaging is accurate in demonstrating SVI prior to radical prostatectomy, and recognition of the most predictive features may facilitate the use of this modality.
journal_name
Radiologyjournal_title
Radiologyauthors
Sala E,Akin O,Moskowitz CS,Eisenberg HF,Kuroiwa K,Ishill NM,Rajashanker B,Scardino PT,Hricak Hdoi
10.1148/radiol.2383050657subject
Has Abstractpub_date
2006-03-01 00:00:00pages
929-37issue
3eissn
0033-8419issn
1527-1315pii
2383050657journal_volume
238pub_type
杂志文章相关文献
RADIOLOGY文献大全abstract::Acquisition and measurement of left ventricular (LV) volumes with a three-dimensional data set of cine magnetic resonance (MR) images from apex to base is a time-consuming process. Results of a study with 10 healthy volunteers and 10 patients with LV hypertrophy were prospectively evaluated. The heart was shown in the...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.188.2.8327680
更新日期:1993-08-01 00:00:00
abstract:PURPOSE:To assess the effect of commonly used computed tomographic (CT) section thicknesses on metastatic tumor measurements calculated with unidimensional, bidimensional, area, and volumetric methods. MATERIALS AND METHODS:Analysis and data collection were approved by the Institutional Review Board, with waived infor...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2343040020
更新日期:2005-03-01 00:00:00
abstract::Four new cases of cranial echinococcosis are presented and the literature is reviewed. Young males are most commonly affected. Early cases present as an expansile osteolytic lesion in the diploe. The more advanced forms manifest as multilocular or unilocular destructive lesions with adjacent soft-tissue masses. Two pa...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/118.1.97
更新日期:1976-01-01 00:00:00
abstract::Blunt trauma to the abdomen is the main cause of pancreatic injury in childhood. One of the most common causes of injury is child abuse. Pancreatitis, pancreatic pseudocyst, and loculated peripancreatic effusion are sequellae of this trauma. The diagnosis of these lesions is aided by ultrasound. Pancreatic injury in c...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.135.1.6153810
更新日期:1980-04-01 00:00:00
abstract::Cardiac masses are usually first detected at echocardiography. In their further evaluation, cardiac magnetic resonance (MR) imaging has become a highly valuable technique. MR imaging offers incremental value owing to its larger field of view, superior tissue contrast, versatility in image planes, and unique ability to...
journal_title:Radiology
pub_type: 杂志文章,评审
doi:10.1148/radiol.13121239
更新日期:2013-07-01 00:00:00
abstract:PURPOSE:To estimate the cost-effectiveness of computed tomographic (CT) colonography for colorectal cancer (CRC) screening in average-risk asymptomatic subjects in the United States aged 50 years. MATERIALS AND METHODS:Enrollees in the American College of Radiology Imaging Network National CT Colonography Trial provid...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.11102411
更新日期:2011-11-01 00:00:00
abstract::Distinction between multicystic kidney and hydronephrosis, the two most common causes of neonatal abdominal masses, is important because of differences in management; however, these two entities may have a similar ultrasonographic appearance. Sonograms of 22 cases of multicystic kidney and hydronephrosis were retrospe...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.151.3.6718720
更新日期:1984-06-01 00:00:00
abstract:PURPOSE:To prospectively compare the accuracy of imaging with technetium-99m-labeled Fab' fragment of the anti-carcinoembryonic antigen antibody (CEA) IMMU-4 with that of computed tomography (CT) for the detection of pelvic recurrence of colorectal carcinoma. MATERIALS AND METHODS:In 61 patients, blinded interpretatio...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.197.3.7480740
更新日期:1995-12-01 00:00:00
abstract:PURPOSE:To test an optimized functional magnetic resonance (MR) imaging procedure to depict the motor hand representation area (HRA) in patients with epilepsy lesions near the central sulcus. MATERIALS AND METHODS:Fast low-angle shot MR imaging was performed with an oblique single-section imaging technique in eight co...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.210.2.r99ja31529
更新日期:1999-02-01 00:00:00
abstract:PURPOSE:To evaluate imaging utilization trends in patients with acute pancreatitis (AP) and to assess independent predictors of radiology usage in relation to patient outcomes. MATERIALS AND METHODS:Institutional review board approval was obtained for this HIPAA-compliant study; written informed consent was waived. AP...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.10100320
更新日期:2011-01-01 00:00:00
abstract::The purpose of this study, which was approved by the institutional review board, was to assess the differentiation of individuals with from those without mesenteric ischemia. All subjects provided written informed consent. Six healthy volunteers and six patients with documented chronic mesenteric ischemia underwent ma...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2342031002
更新日期:2005-02-01 00:00:00
abstract::Three examples of permanently inflated transluminal catheter balloons are presented. Two of these occurred during attempted percutaneous transluminal angioplasty. Nonsurgical solutions, which were successful in each case, are described. Percutaneous puncture with a needle or a larger diameter coaxial catheter under fl...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.155.3.3159040
更新日期:1985-06-01 00:00:00
abstract::Background Several changes have been made to the revised 2017 international consensus guidelines for management of pancreatic intraductal papillary mucinous neoplasms (IPMNs). However, the diagnostic performance is yet to be verified. Purpose To evaluate the revised guidelines for predicting malignant potential of pan...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2019190144
更新日期:2019-10-01 00:00:00
abstract:PURPOSE:To assess how early pleural and/or parenchymal abnormalities consistent with asbestos exposure could be ascertained and to identify factors associated with progression. MATERIALS AND METHODS:Informed consent was obtained under an institutional review board-approved protocol. Multiple sequential chest radiograp...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.10091447
更新日期:2010-06-01 00:00:00
abstract::Purpose To evaluate glass-fiber-based guidewires that are safe for magnetic resonance (MR) imaging-guided endovascular interventions by using a phantom and an in vivo swine model. Materials and Methods MR imaging-safe guidewires were made from micropultruded glass and/or aramid fibers and epoxy resin with diameters of...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2017152742
更新日期:2017-08-01 00:00:00
abstract::Percutaneous tunable dye laser lithotripsy was used in two patients to successfully fragment a 2-cm left hepatic duct calculus and a 5-mm main pancreatic duct calculus. Tunable dye laser lithotripsy may prove to be a more effective alternative to mechanical lithotripsy. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.174.3.1968280
更新日期:1990-03-01 00:00:00
abstract:PURPOSE:To compare imaging findings between laproscopic and open partial nephrectomy at 6 months after surgery and to follow the evolution of the findings over time. MATERIALS AND METHODS:This HIPAA-compliant retrospective study had institutional review board approval and consent was waived. A surgical database was cr...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.10091256
更新日期:2010-05-01 00:00:00
abstract::A new nonionic dimeric contrast medium (CM), iodixanol, was intravenously administered to 40 healthy male volunteers in doses of 0.3-1.2 g of iodine per kilogram of body weight, nonionic monomeric iopamidol and iopentol were administered to 20 others, and the renal effects were studied up to 120 hours after administra...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.182.2.1732960
更新日期:1992-02-01 00:00:00
abstract:PURPOSE:To identify computed tomographic (CT) findings that are associated with the effectiveness of nonsurgical treatment in patients with adhesive small-bowel obstruction ( SBO small-bowel obstruction ) that was initially treated medically. MATERIALS AND METHODS:The local institutional review board approved this ret...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.14132872
更新日期:2014-11-01 00:00:00
abstract:PURPOSE:To investigate the potential application of contrast material-enhanced three-dimensional (3D) ultrasonography (US), as compared with contrast-enhanced 3D computed tomography (CT), for characterization of focal liver tumors. MATERIALS AND METHODS:Institutional review board approval and informed patient consent ...
journal_title:Radiology
pub_type: 杂志文章,随机对照试验
doi:10.1148/radiol.2511081324
更新日期:2009-04-01 00:00:00
abstract:PURPOSE:To evaluate the use of ultrasound (US) for detection of wooden foreign bodies implanted in cadaveric specimens. MATERIALS AND METHODS:Wooden foreign bodies were randomly placed in the plantar soft tissues of three cadaver feet by using 5-mm-long incisions. Ten foreign bodies were 2.5 x 1.0 mm (length x diamete...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.206.1.9423650
更新日期:1998-01-01 00:00:00
abstract::Clinical, radiographic, and radionuclide angiographic findings of three cases of jugular glomic tumor associated with hearing loss are discussed. In one case computed tomographic findings are discussed. It is concluded that radioisotopic techniques may be useful in diagnosis and follow-up of this tumor. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/121.3.673
更新日期:1976-12-01 00:00:00
abstract::Seventeen children with acute renal failure due to the hemolytic-uremic syndrome were examined with duplex Doppler ultrasound. Serial measurements of intrarenal arterial pulsatility were obtained by means of the Pourcelot index. These were compared with daily urine volume, both during the phase of renal failure (durin...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.172.3.2672090
更新日期:1989-09-01 00:00:00
abstract:PURPOSE:To determine whether perfusion-weighted and proton spectroscopic MR imaging can be used to differentiate high-grade primary gliomas and solitary metastases on the basis of differences in vascularity and metabolite levels in the peritumoral region. MATERIALS AND METHODS:Fifty-one patients with a solitary brain ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2223010558
更新日期:2002-03-01 00:00:00
abstract:PURPOSE:To analyze the effect of a decrease in computed tomographic (CT) colonographic voltage, from 100 and 120 kVp to 80 kVp and reconstructed with filtered back projection ( FBP filtered back projection ), on radiation dose, image noise, and diagnostic performance in anthropomorphic phantoms and to assess the effect...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.14140192
更新日期:2014-12-01 00:00:00
abstract::A phase I/II clinical trial with indium-111-labeled antimucin murine monoclonal antibody (MoAb) CCR 086 was conducted. Seventeen patients with histologically proved colorectal carcinoma and known metastatic disease underwent external scintigraphy after administration of 5.5 mCi (203.5 MBq) of In-111 CCR 086 at doses o...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.176.1.2353080
更新日期:1990-07-01 00:00:00
abstract:PURPOSE:To assess the frequency of splenic vein thrombosis (SVT) after splenectomy and its consequences on patient treatment. MATERIALS AND METHODS:A group of 183 consecutive patients who underwent splenectomy were evaluated. Of these patients, 119 underwent postoperative ultrasound (US) or computed tomography. RESUL...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.190.1.8259430
更新日期:1994-01-01 00:00:00
abstract:PURPOSE:To measure the radiologic characteristics of subtle lung nodules and develop nodule phantoms that simulate these characteristics. MATERIALS AND METHODS:From a database of chest radiographs, 16 radiographs that showed confirmed subtle lung nodules were selected. The optical density values surrounding each nodul...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.202.1.8988200
更新日期:1997-01-01 00:00:00
abstract:PURPOSE:To evaluate whether exposure to strong static magnetic fields (SMFs), of up to 10 T, affects the growth and cycle distribution of and the micronucleus formation in monolayered Chinese hamster ovary CHO-K1 cells. MATERIALS AND METHODS:The authors developed a system to expose cultured cells to strong SMFs immedi...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2243011300
更新日期:2002-09-01 00:00:00
abstract::A commercially available double-lumen central venous catheter that can be inserted over a 0.018-inch guide wire was used for ureteral perfusion studies in three infants. Complications or difficulties were not encountered in any patients. This technique allows simultaneous monitoring of perfusion and intrarenal pressur...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.181.1.1887050
更新日期:1991-10-01 00:00:00