Evaluation of the Randox colorimetric serum copper and zinc assays against atomic absorption spectroscopy.

Abstract:

BACKGROUND:Analysis of copper and zinc in serum is commonly performed using atomic absorption spectrometry (AAS); however, these methods are often not readily available in smaller laboratories. Randox colorimetric assays for copper and zinc in serum were evaluated on the Thermo Electron Data Pro analyser against flame AAS methods. METHODS:Copper and zinc were measured in 48 serum samples using the Randox colorimetric copper (CU2340) and zinc (ZN2341) assays on the Data Pro analyser and the results compared with those from a Varian Spectra 880 atomic absorption spectrometer. A smaller set of samples (n = 15) were also analysed colorimetrically for zinc on the Roche Cobas Mira. RESULTS:Linear regression analyses of Bland and Altman plots from the Data Pro - AAS comparison gave the following results for copper: correlation r = 0.6669 (P < 0.01), slope = -0.2499 (P < 0.01), intercept = 3.219 (P < 0.01). For zinc, results were as follows: correlation r = 0.1976, slope = 0.1807, intercept = -1.922. For the smaller set of samples, the Cobas Mira - AAS comparison for zinc gave correlation r = 0.4379, slope = 0.5294, intercept = -4.074. The results indicated significant systematic and fixed bias between the colorimetric copper and the AAS method. CONCLUSION:Performances in comparison to AAS methods indicated the colorimetric methods, as used, are unsuitable for the accurate determination of copper and zinc in human serum.

journal_name

Ann Clin Biochem

authors

Beckett JM,Hartley TF,Ball MJ

doi

10.1258/acb.2009.008253

subject

Has Abstract

pub_date

2009-07-01 00:00:00

pages

322-6

issue

Pt 4

eissn

0004-5632

issn

1758-1001

pii

acb.2009.008253

journal_volume

46

pub_type

杂志文章
  • Auto-antibodies against oxidized LDL as a marker of coronary artery disease in patients with familial hypercholesterolaemia.

    abstract::Auto-antibodies to oxidized low-density lipoprotein (ox-LDL) are thought to play a pivotal role in the pathogenesis of atherosclerosis. This study investigates the value of auto-antibodies to ox-LDL as a predictive marker of atherosclerosis in patients with both homozygous and heterozygous familial hypercholesterolaem...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/0004563001899177

    authors: Paiker JE,Raal FJ,von Arb M

    更新日期:2000-03-01 00:00:00

  • Assessment of the Beckman System 1.

    abstract::The System 1 produced results for glucose and urea which were precise and accurate. It proved suitable as a general laboratory instrument as it samples 28 mul of specimen, is able to calibrate itself, produces results in three minutes, and has the capacity to analyse 56 samples an hour. ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456327701400179

    authors: Potezny N,Quelch J,Fuller B,Geary TD

    更新日期:1977-09-01 00:00:00

  • The ratio of erythrocyte zinc-protoporphyrin to protoporphyrin IX in disease and its significance in the mechanism of lead toxicity on haem synthesis.

    abstract::Protoporphyrin and zinc-protoporphyrin were measured in the erythrocytes of normal subjects, workers exposed to lead and patients with iron deficiency and erythropoietic protoporphyria (EPP). Results showed significantly higher levels of zinc-protoporphyrin in the lead-exposed workers (P < 0.0001), patients with iron ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329803500313

    authors: Nelson JC,Westwood M,Allen KR,Newton KE,Barth JH

    更新日期:1998-05-01 00:00:00

  • Free ionised calcium--a critical survey.

    abstract::It is our aim to summarise and discuss procedures for the evaluation of the concentration of free ionised calcium in serum or plasma. Stress is laid upon the interrelations and relative validity of the most common algebraic expressions to appraise the calcium status. The multitude of formulae proposed in the literatur...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章,评审

    doi:10.1177/000456328402100501

    authors: Vanstapel FJ,Lissens WD

    更新日期:1984-09-01 00:00:00

  • A novel method for measuring serum ornithine carbamoyltransferase.

    abstract:BACKGROUND:Serum ornithine carbamoyltransferase is a diagnostic marker of hepatic disorders due to its localization in periportal mitochondria. METHODS:We have developed a new method for the determination of serum ornithine carbamoyltransferase. It is based on the reverse reaction of ornithine carbamoyltransferase, us...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/000456303321610583

    authors: Ishikawa H,Matsuzawa T,Ohashi K,Nagamura Y

    更新日期:2003-05-01 00:00:00

  • Assays for prolactin: guidelines for the provision of a clinical biochemistry service.

    abstract::This paper summarises the views of the authors on the provision of a prolactin assay service. We discuss the pathophysiology of prolactin secretion and the clinical indications that arise from that. We cover the rather complex issue of the definition of normal and elevated prolactin levels. From these considerations, ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章,评审

    doi:10.1177/000456328602300603

    authors: Jeffcoate SL,Bacon RR,Beastall GH,Diver MJ,Franks S,Seth J

    更新日期:1986-11-01 00:00:00

  • Influence of age, posture and intra-individual variation on plasma levels of atrial natriuretic peptide.

    abstract::This paper describes some factors to which attention should be paid when atrial natriuretic peptide (ANP) values are to be interpreted. Changing from the supine to the sitting position decreased ANP levels, while no further decrease was observed when the upright position was assumed. On the other hand, plasma renin ac...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328902600604

    authors: Tan AC,Kloppenborg PW,Benraad TJ

    更新日期:1989-11-01 00:00:00

  • Severely impaired activity of lipoprotein lipase Arg243His is partially ameliorated by emulsifying phospholipids in in vitro triolein hydrolysis analysis.

    abstract::Background We investigated the in vitro effects of various phospholipids as emulsifiers on the hydrolysing activities of lipoprotein lipase (LPL) Arg243His against triolein as substrate. LPL Arg243His, identified in a patient with hyperchylomicronaemia, displays severely diminished activity for triolein when emulsifie...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/0004563217693258

    authors: Yamaguchi T,Murano T,Tatsuno I,Hiruta N,Suzuki T,Sawada S,Katagiri H,Shirai K,Schneider WJ,Bujo H

    更新日期:2017-11-01 00:00:00

  • Serum calcium, parathyroid hormone, and vitamin D status in children and young adults with sickle cell disease.

    abstract::The concentrations of serum calcium, parathyroid hormone (PTH), 25 Hydroxyvitamin D (25OHD), and 1,25 Dihydroxyvitamin D (1,25(OH)2D) were determined in 99 Saudi patients with sickle cell disease and in 104 matching healthy controls. Serum calcium and 25OHD were significantly lower in the patients, with 14% and 12% of...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329303000108

    authors: Mohammed S,Addae S,Suleiman S,Adzaku F,Annobil S,Kaddoumi O,Richards J

    更新日期:1993-01-01 00:00:00

  • A simple liquid chromatography linked to tandem mass spectrometry method for measurement of serum cholinesterase activity using succinylcholine as substrate.

    abstract:BACKGROUND:Individuals who are unable to metabolize the short-acting muscle relaxant succinylcholine due to abnormal cholinesterase activity are currently investigated via spectrophotometry using artificial substrates and enzyme inhibitors. Methods have been described using succinylcholine as substrate but with measure...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/acb.2010.009169

    authors: Spencer JD,Rushton D,Allen KR

    更新日期:2010-05-01 00:00:00

  • Pneumatic tube system induced haemolysis: assessing sample type susceptibility to haemolysis.

    abstract:BACKGROUND:The pneumatic tube system (PTS) has been implicated in inducing haemolysis. It is not known whether certain sample types are more susceptible to haemolysis than others. We assessed the level of haemolysis in commonly used sample types in the clinical biochemistry department when transported through the PTS. ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/000456304323019631

    authors: Sodi R,Darn SM,Stott A

    更新日期:2004-05-01 00:00:00

  • Troponin T for the differential diagnosis of ischaemic myocardial damage.

    abstract::The diagnostic performance of a new enzyme linked immunosorbent assay for the cardiac structural protein troponin T in the differential diagnosis of ischaemic cardiac damage was assessed. A well documented set of patients admitted to the coronary care unit of a district general hospital were studied. At a cutoff value...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329303000102

    authors: Collinson PO,Moseley D,Stubbs PJ,Carter GD

    更新日期:1993-01-01 00:00:00

  • Stabilization of circulating thyroglobulin mRNA transcripts in patients treated for differentiated thyroid carcinoma.

    abstract::Background The clinical utility of serum thyroglobulin in the follow-up of patients with differentiated thyroid carcinoma may be compromised by the presence of endogenous antithyroglobulin antibodies. To prevent interference by antithyroglobulin antibodies several groups have developed real-time PCR-based assays for q...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/0004563216671538

    authors: Feddersen S,Bastholt L,Pedersen SM

    更新日期:2017-09-01 00:00:00

  • An automated method for the analysis of urinary free catecholamines using ASTED and high-pressure liquid chromatography.

    abstract::A high-pressure liquid chromatography procedure for the measurement of free catecholamines in urine is described. 'On-line' sample preparation using a cartesian robot combined with the ASTED process ensures minimal operator intervention and reduced costs. ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328902600412

    authors: Green B,Cooper JD,Turnell DC

    更新日期:1989-07-01 00:00:00

  • Clinical usefulness of the simultaneous localisation of the isoenzymes of alkaline phosphate and gamma-glutamyl transferase.

    abstract::Simultaneous localisation of the isoenzymes of alkaline phosphatase and gamma-glutamyl transferase was carried out on 173 serum samples from patients with hepatobiliary and bone disease to determine (i) if a better discrimination of the underlying pathology could be obtained by such an approach, and (ii) if the pathol...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328001700104

    authors: Baines M

    更新日期:1980-01-01 00:00:00

  • Measurement of urinary cystatin C by particle-enhanced nephelometric immunoassay: precision, interferences, stability and reference range.

    abstract:BACKGROUND:Urinary excretion of the low molecular weight protein cystatin C is a marker of renal disorders and a good predictor of the severity of acute tubular necrosis. We evaluated the measurement of urinary cystatin C and determined its reference range. METHODS:Measurement of urinary cystatin C by particle-enhance...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/000456304322879980

    authors: Herget-Rosenthal S,Feldkamp T,Volbracht L,Kribben A

    更新日期:2004-03-01 00:00:00

  • The entero-insular axis in polycystic ovarian syndrome.

    abstract::We investigated the contributions made by the entero-insular axis, proinsulin and the fractional hepatic extraction of insulin to the hyperinsulinaemia characteristic of polycystic ovarian syndrome (PCOS). We measured plasma glucose, gastric inhibitory polypeptide (GIP), glucagon-like peptide-1 (7-36 amide) (GLP-1(7-3...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329603300303

    authors: Gama R,Norris F,Wright J,Morgan L,Hampton S,Watkins S,Marks V

    更新日期:1996-05-01 00:00:00

  • Natural selection? The evolution of diagnostic criteria for gestational diabetes.

    abstract::Gestational diabetes is a common pregnancy disorder which is generally managed with diet, exercise, metformin or insulin treatment and which usually resolves after delivery of the infant. Identifying and treating gestational diabetes improves maternal and fetal outcomes and allows for health promotion to reduce the mo...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章,评审

    doi:10.1177/0004563216674743

    authors: Meek CL

    更新日期:2017-01-01 00:00:00

  • Evaluation of menstrual cycle-related changes in 85 clinical laboratory analytes.

    abstract:OBJECTIVE:The menstrual cycle-related changes in clinical laboratory values were analysed by use of data obtained in the Asian multicentre study aimed at derivation of common reference intervals for 85 major clinical laboratory tests. METHODS:Among 1876 healthy female volunteers, 893 had regular menstruation. They wer...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/0004563215617212

    authors: Masuda S,Ichihara K,Yamanishi H,Hirano Y,Tanaka Y,Kamisako T,Scientific Committee for Asia-Pasific Federation of Clinical Biochemistry.

    更新日期:2016-05-01 00:00:00

  • Radioimmunoassay of trypsin. A new aid in the assessment of pancreatic function.

    abstract::This review describes the development and application of a novel test to determine levels of human immunoreactive trypsin, an enzyme produced solely by the pancreas, in biological fluids. Being organ-specific, the assay of immunoreactive trypsin should be an ideal marker of pancreatic function, and this is supported b...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456327901600131

    authors: Stagg BH,Wood TP

    更新日期:1979-05-01 00:00:00

  • Evaluation of specific high-performance liquid-chromatographic determinations of urinary metanephrine and normetanephrine by comparison with isotope dilution mass spectrometry.

    abstract::A method for the determination of metanephrine (MN; also known as metadrenaline), normetanephrine (NMN; also known as normetadrenaline) and 3-methoxytyramine (3-MT) in human urine using high-performance liquid chromatography followed by electrochemical detection (ECD) was validated primarily by comparing the results w...

    journal_title:Annals of clinical biochemistry

    pub_type: 更正并重新发布的文章,杂志文章

    doi:10.1258/0004563011900984

    authors: Willemsen JJ,Ross HA,Wolthers BG,Sweep CG,Kema IP

    更新日期:2001-11-01 00:00:00

  • The evaluation of imprecision in collaborative immunoassay quality-assessment programmes.

    abstract::The calculation of within-laboratory imprecision in quality-assessment (QA) programmes normally involves combining data from different analyte concentrations to calculate an average standard deviation (SD) or coefficient of variation. However, for immunoassay neither of these parameters is concentration independent. T...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328402100611

    authors: Compton P,Cole B,Stuart M,Egan G

    更新日期:1984-11-01 00:00:00

  • Prevalence of haemoglobin variants in a diabetic population and their effect on glycated haemoglobin measurement.

    abstract::The measurement of glycated haemoglobin (glycated Hb) by automated high pressure liquid chromatography enabled the prevalence of haemoglobin variants (Hb variant) to be determined in a large diabetic population within Leeds, UK. There were 16 patients showing a Hb variant amongst a total of 5300 diabetics, the majorit...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329202900410

    authors: Allen KR,Hamilton AD,Bodansky HJ,Poon P

    更新日期:1992-07-01 00:00:00

  • The measurement of serum unsaturated iron-binding capacity in the presence of iron-dextran.

    abstract::The standard colorimetric methods most often used for the measurement of serum unsaturated iron binding capacity (UIBC) are subject to gross interference by iron dextran. This paper describes a brief evaluation of an alternative radiometric assay for serum UIBC, based on a commercially available kit method, but incorp...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328802500323

    authors: Kind CN

    更新日期:1988-05-01 00:00:00

  • A simple, rapid and cheap radioimmunoassay for plasma digoxin.

    abstract::A radioimmoassay for digoxin is described which uses commercially available reagents. Two assay procedures are used, one for batch assays, and another, which needs a 5 minute incubation only, for 'stat' assays. The methods are shown to be simple, rapid, precise and inexpensive and the batch procedure compared well wit...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328502200216

    authors: Moore RA,Turner M,Cousins J,Gales M

    更新日期:1985-03-01 00:00:00

  • A systematic evaluation of immunoassay point-of-care testing to define impact on patients' outcomes.

    abstract::Background Point-of-care testing has been developed to provide rapid test results. Most published studies focus on analytical performance, neglecting its impact on patient outcomes. Objective To review the analytical performance and accuracy of point-of-care testing specifically planned for immunoassay and to evaluate...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/0004563217694377

    authors: Pecoraro V,Banfi G,Germagnoli L,Trenti T

    更新日期:2017-07-01 00:00:00

  • Clinical need-directed blood tests: a step in saving the NHS?

    abstract:BACKGROUND:Unnecessary blood tests are estimated to contribute to 25% of wastage in the National Health Service. The aim of this study was to assess the financial implication of clinical need-focused blood tests guided by a senior clinician in a district general hospital. METHODS:We conducted an observational longitud...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/0004563215617782

    authors: Mughal Z,Narayanan A,Gupta V,Reay-Jones N

    更新日期:2016-09-01 00:00:00

  • Interleukin 6 in cerebrospinal fluid of patients with meningitis is not a useful diagnostic marker in the differential diagnosis of meningitis.

    abstract::We assayed interleukin 6 (IL-6) concentrations in cerebrospinal fluid (CSF) from patients affected by meningitis of different aetiologies, and verified whether IL-6 can be used as a diagnostic marker in the differential diagnosis of meningitis. We used a monoclonal antibody enzyme immunoassay to test 98 CSF samples cl...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329703400206

    authors: López-Cortés LF,Cruz-Ruiz M,Gómez-Mateos J,Jiménez-Hernández D,Viciana-Fernández P,Jiménez-Mejías E

    更新日期:1997-03-01 00:00:00

  • Identification of molecular species of cholesteryl ester hydroperoxides in very low-density and intermediate-density lipoproteins.

    abstract:BACKGROUND:Oxidation of lipoproteins is thought to play a crucial role in atherogenesis. Role for triglyceride-rich lipoproteins in atherogenesis is unclear. Thus, we aimed to investigate whether cholesteryl ester hydroperoxides (CEOOH) are present in very low-density lipoproteins (VLDL) and intermediate-density lipopr...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/0004563213516093

    authors: Shrestha R,Hui SP,Sakurai T,Yagi A,Takahashi Y,Takeda S,Jin S,Fuda H,Chiba H

    更新日期:2014-11-01 00:00:00

  • Empiricism or rationalism: how should we measure proteinuria?

    abstract::Proteinuria is the cardinal sign of renal disease, therefore accurate identification of clinically significant proteinuria is essential to the diagnosis and management of kidney disease. Spot samples are now widely used, namely protein: creatinine ratio (uPCR) and albumin: creatinine ratio (uACR). In this article we r...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章,评审

    doi:10.1177/0004563212473283

    authors: Methven S,MacGregor MS

    更新日期:2013-07-01 00:00:00