Abstract:
:The purpose of the study was to evaluate a semiautomatic analysis tool for assessing global left ventricular myocardial function with multislice computed tomography (MSCT). We examined 33 patients with MSCT using 16x0.5 mm detector collimation and magnetic resonance imaging (MRI) on a 1.5-T scanner. MSCT data were analyzed using semiautomatic volumetric analysis software (ANET, CSCF-001A, Toshiba). This software tool automatically creates endo- and epicardial contours that can be manually corrected on all short-axis slices at all reconstructed time points within the cardiac cycle, based on a contour-detection and density-threshold algorithm. All global left ventricular function parameters assessed with the semiautomatic MSCT software were highly correlated with the results of MRI. Bland-Altman analysis showed minor systematic overestimation of end-diastolic (10.7 ml) and end-systolic volumes (5.6 ml) and underestimation of ejection fraction (2.1%) with MSCT as compared with MRI. The post-processing time was moderately but significantly longer with the MSCT software (15.9+/-2.8 min) than necessary for MRI (14.0+/-2.5 min, P<0.01), mainly as a result of the longer time required for uploading of the MSCT datasets, which were on average 54 times larger (1.3 GByte). In conclusion, it appears feasible to accurately assess global left ventricular function with MSCT in a reasonable post-processing time using a semiautomatic software tool.
journal_name
Eur Radioljournal_title
European radiologyauthors
Dewey M,Müller M,Teige F,Hamm Bdoi
10.1007/s00330-005-2817-7subject
Has Abstractpub_date
2006-01-01 00:00:00pages
25-31issue
1eissn
0938-7994issn
1432-1084journal_volume
16pub_type
临床试验,杂志文章abstract:BACKGROUND:Transient elastography-based liver stiffness value (TE-LSV) has been investigated for assessing clinically significant portal hypertension (CSPH). The aetiology of CSPH is an important factor determining TE-LSV. There is insufficient evidence for selecting cut-off values. AIMS:This study performed a meta-an...
journal_title:European radiology
pub_type: 杂志文章,meta分析
doi:10.1007/s00330-018-5478-z
更新日期:2018-12-01 00:00:00
abstract:OBJECTIVES:To determine whether changes in ADC of bone metastases secondary to prostate carcinoma are significantly different in responders compared with progressors on chemotherapy. METHODS:Twenty-six patients with known bone metastases secondary to prostate carcinoma underwent diffusion-weighted MRI of the lumbar sp...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-011-2173-8
更新日期:2011-10-01 00:00:00
abstract::Our objective was to assess the clinical value of an early arterial scan for assessing the hepatic and mesenteric vasculature in patients with suspected primary or metastatic hypervascular liver disease undergoing multislice computed tomography. In 42 patients a very early arteriographic scan was performed before stan...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-002-1566-0
更新日期:2003-05-01 00:00:00
abstract::We report the case of a 1.5-year-old girl with transient protein-losing gastropathy with hypertrophic gastric folds (PLGH). The diagnosis of PLGH was made by abdominal ultrasound (US) and not by an upper gastrointestinal (UGI) study as reported in many previous publications. Real-time compound ultrasound imaging showe...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-003-2071-9
更新日期:2003-12-01 00:00:00
abstract::The advent of radiologic guidance techniques for percutaneous biopsy has changed the approach to the routine diagnosis of mediastinal lymphoma. The aim of the present study was to evaluate the diagnostic accuracy of CT-guided percutaneous core-needle biopsy (PCNB) in the clinical management of patients with mediastina...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300050991
更新日期:2000-01-01 00:00:00
abstract::This discussion on developments within publishing presents further thought on green, gold and hybrid models of open access. It also discusses some of the advantages and disadvantages which may be encountered by researchers, authors, institutions, scientific organisations and publishers. ...
journal_title:European radiology
pub_type: 评论,社论
doi:10.1007/s00330-013-2777-2
更新日期:2013-05-01 00:00:00
abstract:OBJECTIVES:To demonstrate the feasibility of using chemical exchange saturation transfer (CEST) imaging to detect Parkinson's disease (PD) in patients at 3 Tesla. METHODS:Twenty-seven PD patients (17 men and 10 women; age range, 54-77 years) and 22 age-matched normal controls (13 men and 9 women; age range, 55-73 year...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-014-3241-7
更新日期:2014-10-01 00:00:00
abstract:OBJECTIVE:This retrospective study aims to assess the accuracy of two-phase computed tomography (CT) and transoesophageal echocardiography (TEE) for the detection of left atrial (LA) thrombus in patients with mitral stenosis (MS) and atrial fibrillation (AF), by using intraoperative findings as the reference standard. ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-013-2944-5
更新日期:2013-11-01 00:00:00
abstract:UNLABELLED:Imaging plays an increasingly important role in the early diagnosis, prognosis prediction and therapy response evaluation of central nervous system (CNS) diseases. The newly emerging hybrid positron emission tomography/magnetic resonance imaging (PET/MRI) can perform "one-stop-shop" evaluation, including ana...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s00330-015-4202-5
更新日期:2016-10-01 00:00:00
abstract::Inflammatory myofibroblastic tumour (IMFT) is a distinct entity under the group of inflammatory pseudotumours. Sometimes these pseudotumours can have an aggressive appearance on imaging, which makes it indistinguishable from other malignant neoplasms. We present a case of IMFT of the bladder in a child. ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-009-1646-5
更新日期:2010-08-01 00:00:00
abstract::Ovarian cancer is the most lethal among the gynecologic malignancies with approximately 70% of patients presenting with advanced tumor stage. The prognosis of patients with ovarian cancer is directly related to the tumor stage and residual tumor burden after cytoreductive surgery. Exploratory laparotomy has been the c...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s00330-007-0736-5
更新日期:2007-12-01 00:00:00
abstract::Magnetic resonance imaging can be used to measure the muscle volume of a given muscle or muscle group. The purpose of this study was to determine both the intra- and inter-observer variation of the manually outlined volume of the extensor muscles (tibialis anterior, extensor digitorum longus and extensor hallucis long...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-002-1334-1
更新日期:2002-12-01 00:00:00
abstract::Intussusception represents the most common abdominal emergency in infancy. The classical clinical triad, consisting of abdominal colics, red jelly stools and a palpable mass, is only present in approximately 50% of cases, 20% of patients are symptom free at clinical presentation. Primary imaging modality of choice is ...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s00330-003-2033-2
更新日期:2004-03-01 00:00:00
abstract:OBJECTIVE:The aim of the study was to assess the performance and diagnostic value of a dual energy CT approach to reduce metal artefacts in subjects with metallic implants. METHODS:31 patients were examined in the area of their metallic implants using a dual energy CT protocol (filtered 140 kVp and 100 kVp spectrum, t...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-011-2062-1
更新日期:2011-07-01 00:00:00
abstract:OBJECTIVE:To evaluate the diagnostic accuracy of split-bolus single-scan computed tomography angiography (CTA) protocol for evaluation of acute mesenteric ischemia and alternate diagnoses. MATERIALS AND METHODS:In this IRB-approved, HIPAA-compliant retrospective study, consecutive patients from 21 October 2016 to 6 Ma...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-020-06769-x
更新日期:2020-07-01 00:00:00
abstract:OBJECTIVE:To compare imaging findings with histopathology in AML without visible fat (AMLwvf). MATERIAL AND METHODS:With IRB approval, we identified 18 AMLwvf that underwent CT between 2002-2014. A radiologist measured NECT-attenuation, corticomedullary (CM) and nephrographic (NG) enhancement, echogenicity relative to...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-015-3851-8
更新日期:2016-02-01 00:00:00
abstract:OBJECTIVES:To establish the role of unenhanced CT in predicting the outcome of liver hydatid cysts. We sought to determine whether the presence of laminated membrane detachment (LMD) or pericyst degenerative changes (PDCs) detected on CT were reliable signs for predicting a favorable outcome of liver hydatids. METHODS...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-020-07681-0
更新日期:2021-01-16 00:00:00
abstract:OBJECTIVES:To evaluate factors associated with increased fluoroscopy time or the need for complex techniques at IVC filter retrieval. METHODS:This is a single-institution retrospective cohort study of 187 consecutive patients who underwent IVC filter retrieval. An analysis was performed on associations of patient fact...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-018-5766-7
更新日期:2019-04-01 00:00:00
abstract:OBJECTIVES:Multi-detector-row computed tomography angiography (MDCTA) plays an important role in the assessment of patients with suspected coronary artery disease. However, MDCTA tends to overestimate stenosis in calcified coronary artery lesions. The aim of our study was to evaluate the diagnostic performance of calci...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-016-4675-x
更新日期:2017-07-01 00:00:00
abstract:OBJECTIVES:To evaluate the agreement between automated breast volume scanner (ABVS) and conventional ultrasound (US) as a second-look (SL) tool for assessing additional findings found on MRI. METHODS:Over a 7-month period, we prospectively assigned to SL-US and SL-ABVS all patients undergoing 1.5 T breast MRI in whom ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-017-4749-4
更新日期:2017-09-01 00:00:00
abstract:OBJECTIVES:To evaluate changes in T1 and T2* relaxometry of dentate nuclei (DN) with respect to the number of previous administrations of Gadolinium-based contrast agents (GBCA). METHODS:In 74 relapsing-remitting multiple sclerosis (RR-MS) patients with variable disease duration (9.8±6.8 years) and severity (Expanded ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-016-4245-2
更新日期:2016-12-01 00:00:00
abstract:OBJECTIVES:The purpose of this study was to compare findings of ultrasound (US) with dual-energy CT (DECT) in patients presenting with suspected gouty hand and wrist arthritis. METHODS:This prospective study included 180 patients (136 men and 44 women, age range, 31- 94 years; mean age, 65.9 years) with an initial cli...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-018-5363-9
更新日期:2018-10-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to evaluate whether the orientation of the heart, measured as an angle between the long axis of the heart and ascending aorta midline (heart-aorta-angle, HAA), associates with ascending aortic (AA) dilatation. Furthermore, the association between HAA and wall shear stress (WSS) was ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-020-06852-3
更新日期:2020-09-01 00:00:00
abstract:OBJECTIVE:The purpose of study was to develop a computer-simulated liver phantom for hepatic CT studies. A computer-simulated liver phantom was mathematically constructed on a computer workstation. MATERIALS AND METHODS:The computer-simulated phantom was calibrated using real CT images acquired by an actual four-detec...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-005-0012-5
更新日期:2006-04-01 00:00:00
abstract::Modern liver imaging of cancer patients requires an imaging modality that is not only highly sensitive in detecting lesions but also provides reliable characterisation of lesions and thus allows differentiation of metastases from frequently found benign lesions. Conventional ultrasound (US) has a relatively poor sensi...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s10406-004-0088-z
更新日期:2004-10-01 00:00:00
abstract::The increasing availability of high-field (3 T) MR scanners requires adapting and optimizing clinical imaging protocols to exploit the theoretically higher signal-to-noise ratio (SNR) of the higher field strength. Our aim was to establish reliable and stable protocols meeting the clinical demands for imaging the neuro...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-003-1984-7
更新日期:2003-09-01 00:00:00
abstract::The purpose of our study was to investigate whether quantitative diffusion-weighted images (DWI) were useful for monitoring the therapeutic response of primary bone tumors. We encountered 18 osteogenic and Ewing sarcomas. Magnetic resonance (MR) images were performed in all patients before and after therapy. We measur...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-006-0342-y
更新日期:2006-12-01 00:00:00
abstract:OBJECTIVES:To determine whether phase-contrast X-ray imaging can be used to visualise directly the accumulated extracellular matrix proteins associated with liver fibrosis in common bile duct ligated mice. METHODS:Twenty-six-week-old C57BL female mice were randomised into three groups. In groups 1 (n = 5) and 2 (n = 1...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-012-2630-z
更新日期:2013-02-01 00:00:00
abstract:OBJECTIVES:To evaluate visualization of the right adrenal vein (RAV) with multidetector CT and non-contrast-enhanced MR imaging in patients with primary aldosteronism. METHODS:A total of 125 patients (67 men) scheduled for adrenal venous sampling (AVS) were included. Dynamic 64-detector-row CT and balanced steady-stat...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-015-3872-3
更新日期:2016-03-01 00:00:00
abstract:OBJECTIVE:To retrospectively evaluate the diagnostic performance of single-phase dual-energy CT (DECT) with virtual non-contrast CT (VNCT) compared with three-phase CT urography (CTU) in patients with haematuria. METHODS:A total of 296 patients underwent three-phase CTU (NCT at 120 kVp; nephrographic phase and excreto...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-016-4206-9
更新日期:2016-10-01 00:00:00