First trimester maternal serum screening for Down's syndrome: an evaluation of the DPC Immulite 2000 free beta-hCG and pregnancy-associated plasma protein-A assays.

Abstract:

BACKGROUND:Recent NICE Guidelines have emphasized the need to have in place by 2007 the capability of offering screening to all women in the first trimester using a combination of maternal age with the ultrasound marker nuchal translucency thickness (NT) and the maternal serum biochemical markers free beta-hCG and pregnancy-associated plasma protein-A (PAPP-A). Laboratories will therefore need to consider how to introduce the biochemical component of screening. With the recent launch of these assays on the DPC Immulite 2000 platform, it is appropriate and timely to investigate their clinical and analytical performance on a high throughput immunoassay analyser. METHODS:Within-run and between-day precision was assessed in the normal way. Bias was assessed by comparing samples from normal pregnancies (n=813) and pregnancies with Down's syndrome (n=60) run on both the DPC system and our routine Kryptor system. Gestational day-specific medians for each marker were calculated from the unaffected population. Mathematical modelling was used to predict the clinical performance of the two markers. RESULTS:The within-run coefficient of variation (CV) was around 3.5% and between-day CV was around 6-8% for both assays. Comparison with EQA samples showed a 2% positive bias against the ALTM for free beta-hCG and a 21% positive bias for PAPP-A, which reduced to 11% when compared with the Kryptor method mean. When compared with the Kryptor, the DPC free beta-hCG showed a significant concentration-related negative bias above concentrations of 50 IU/L in both unaffected and affected pregnancy samples. After conversion to MoM in the Down's syndrome group, the DPC free beta-hCG assay showed a MoM-related bias at higher MoM values. For PAPP-A a positive MoM-related bias was also evident. In cases with Down's syndrome, the median free beta-hCG MoM was 1.703 for DPC and 1.698 by the Kryptor, which was not significantly different. For PAPP-A, the median MoM was 0.62 for DPC and 0.47 by the Kryptor, which was significantly (P=0.025) different. This difference, if real, is likely to result in a lower detection of cases with Down's syndrome. Statistical modelling techniques suggest that this would be 58% compared with the expected 67% when combined with maternal age and free beta-hCG. When combined with NT, however, this would be reduced to 85% compared with the 90% expected. CONCLUSIONS:While laboratories may find some organizational benefit from running first trimester Down's syndrome screening on such routine high-throughput immunoassay analysers, better clinical performance is likely to be achieved with alternative platforms to the DPC Immulite 2000.

journal_name

Ann Clin Biochem

authors

Spencer K

doi

10.1258/0004563053026880

subject

Has Abstract

pub_date

2005-01-01 00:00:00

pages

30-40

issue

Pt 1

eissn

0004-5632

issn

1758-1001

journal_volume

42

pub_type

杂志文章
  • The evaluation of a novel conductometric device for the diagnosis of cystic fibrosis.

    abstract:BACKGROUND:We evaluated the diagnostic discrimination of a new micro-flow cell device (Nanoduct) which measures sweat conductivity in situ at a regional referral centre for cystic fibrosis (CF). METHODS:The device was evaluated in comparison to the measurement of sweat chloride with the established quantitative piloca...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/000456306778520025

    authors: Losty HC,Wheatley H,Doull I

    更新日期:2006-09-01 00:00:00

  • Serum and plasma 5-hydroxyindoleacetic acid as an alternative to 24-h urine 5-hydroxyindoleacetic acid measurement.

    abstract:BACKGROUND:Neuroendocrine tumours are slow growing tumours known to secrete a variety of vasoactive peptides which give rise to symptoms of the carcinoid syndrome. The diagnosis and monitoring of patients with neuroendocrine tumours is undertaken in many centres using 24 h urinary measurement of 5-hydroxyindoleacetic a...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/0004563215613109

    authors: Adaway JE,Dobson R,Walsh J,Cuthbertson DJ,Monaghan PJ,Trainer PJ,Valle JW,Keevil BG

    更新日期:2016-09-01 00:00:00

  • Revised national guidelines for analysis of cerebrospinal fluid for bilirubin in suspected subarachnoid haemorrhage.

    abstract::It is crucially important to detect subarachnoid haemorrhage (SAH) in all patients in whom it has occurred to select patients for angiography and preventative surgery. A computerized tomography (CT) scan is positive in up to 98% of patients with SAH presenting within 12 h, but is positive in only 50% of those presenti...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/acb.2008.007257

    authors: Cruickshank A,Auld P,Beetham R,Burrows G,Egner W,Holbrook I,Keir G,Lewis E,Patel D,Watson I,White P,UK NEQAS Specialist Advisory Group for External Quality Assurance of CSF Proteins and Biochemistry.

    更新日期:2008-05-01 00:00:00

  • Effect of ambient temperature on analytical and clinical performance of a blood glucose monitoring system: Omnitest Sensor glucose meter.

    abstract::The effect of ambient temperature on the analytical and clinical performance of a glucose meter was examined. A total of 114 venous whole blood samples were analysed for glucose by a reference method, and by a glucose meter at 21-22 degrees C, room temperatures, 26-27 degrees C and 33-34 degrees C. Glucose meter readi...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/0004563011901091

    authors: Nawawi H,Sazali BS,Kamaruzaman BH,Yazid TN,Jemain AA,Ismail F,Khalid BA

    更新日期:2001-11-01 00:00:00

  • Assessment of oxygenation in the critically ill.

    abstract::This paper reviews the physiology and pathology of oxygen transport from the atmosphere to the cells in critically ill patients. A thorough understanding of this allows a rational approach to monitoring and managing an hypoxic patient in the intensive care setting. ...

    journal_title:Annals of clinical biochemistry

    pub_type: 指南,杂志文章,评审

    doi:10.1177/000456329102800104

    authors: Clapham MC

    更新日期:1991-01-01 00:00:00

  • A modified method for the estimation of galactose-1-phosphate.

    abstract::The measurement of galactose-1-phosphate has been advocated for monitoring galactosaemia. A radioenzymatic method is described in which red-cell haemolysates are incubated with radiolabelled uridine diphospho-glucose and exogenous galactose-1-phosphate uridyl transferase. Labelled glucose-1-phosphate is formed in prop...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328602300313

    authors: Dobbie JA,Holton JB

    更新日期:1986-05-01 00:00:00

  • The case of stainless statins.

    abstract::Two cases of hypercholesterolaemic patients are presented in whom raised plasma creatine kinase was noted during treatment with statins. The plasma creatine kinase failed to fall following cessation of therapy. Further investigation revealed the aetiology of the raised plasma creatine kinase to be due to previously un...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/000456303322326542

    authors: Barth JH,Brownjohn AM,Jamieson DR

    更新日期:2003-09-01 00:00:00

  • An apparent phaeochromocytoma and abnormal thyroid function tests.

    abstract::A 41-year-old lady presented with classical symptoms of a phaeochromocytoma and markedly elevated urinary adrenaline concentration. Urinary fractionated metanephrine and normetanephrine concentrations were within the normal reference range. Computed tomography of the abdomen/pelvis and I(123) meta-iodobenzylguanidine ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/acb.2007.007106

    authors: King TF,Shea PO,Sullivan EP,Srinivasan R,Griffin A,Fitzgerald R,Tormey W,Smith D

    更新日期:2008-03-01 00:00:00

  • Differential response of serum alkaline phosphatase and serum osteocalcin in Paget's osteosarcoma.

    abstract::Serum osteocalcin did not show any response to the onset of osteosarcoma in Paget's disease of bone whereas serum alkaline phosphatase increased rapidly. This suggests that osteocalcin is not useful in the diagnosis and management of Paget's osteosarcoma and does not reflect the same osteoblastic processes in bone as ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329102800216

    authors: Davie MW,Worsfold M,Sharp CA

    更新日期:1991-03-01 00:00:00

  • Faecal elastase 1: a marker of exocrine pancreatic insufficiency in cystic fibrosis.

    abstract::Pancreatic elastase 1 (E1), a digestive protease, is synthesized by the acinar cells of the pancreas. Using an enzyme-linked immunosorbent assay, we evaluated stool E1 levels in the following groups of patients. (a) Specimens submitted for occult blood examination from 20 adults, over 3 consecutive days, to assess the...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329903600606

    authors: Phillips IJ,Rowe DJ,Dewar P,Connett GJ

    更新日期:1999-11-01 00:00:00

  • Serum total sialic acid and lipid-associated sialic acid in normal individuals and patients with myocardial infarction, and their relationship to acute phase proteins.

    abstract::Serum total sialic acid (TSA) has gained medical interest, particularly as a cardiovascular risk factor and it has been hypothesized that serum levels relate to serum acute phase proteins, some of which are sialylated. We assayed serum TSA and also lipid associated sialic acid (LASA) in 50 normal individuals (24 male)...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329303000406

    authors: Haq M,Haq S,Tutt P,Crook M

    更新日期:1993-07-01 00:00:00

  • Serum albumin-adjusted glycated albumin is a better indicator of glycaemic control in diabetic patients with end-stage renal disease not on haemodialysis.

    abstract:BACKGROUNDS:Diabetic patients with end-stage renal disease who are not on haemodialysis show low concentrations of HbA1c and glycated albumin due to renal anaemia and proteinuria, respectively. In the present study, we examined whether serum albumin-adjusted glycated albumin could accurately reflect glycaemic control i...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/0004563214568162

    authors: Fukami K,Shibata R,Nakayama H,Yamada K,Okuda S,Koga M

    更新日期:2015-07-01 00:00:00

  • Intraindividual variation in serum thyroid hormones, parathyroid hormone and insulin-like growth factor-1.

    abstract:BACKGROUND:Biological variation of an analyte is an important determinant of its usefulness. Intraindividual variation in serum thyroid hormones, parathyroid hormone (PTH) and insulin-like growth factor-1 (IGF-1) in healthy subjects was determined in this study. METHODS:Blood samples were taken at weekly intervals for...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/acb.2007.007103

    authors: Ankrah-Tetteh T,Wijeratne S,Swaminathan R

    更新日期:2008-03-01 00:00:00

  • Urine-free cortisol excretion: evidence of sex-dependence.

    abstract::Measurement of urine-free (unconjugated) cortisol (UFC) excretion is widely used in the investigation of hypercortisolaemia. We have measured 24 h UFC excretion in normal healthy individuals using a radioimmunoassay (RIA) method claimed to be suitable for unextracted urine. Significantly higher rates of excretion were...

    journal_title:Annals of clinical biochemistry

    pub_type: 临床试验,杂志文章

    doi:10.1177/000456329403100505

    authors: Lamb EJ,Noonan KA,Burrin JM

    更新日期:1994-09-01 00:00:00

  • A data processing system for a group of three clinical chemistry laboratories. 1. Hardware and organisation.

    abstract::A real time data processing system for a group of three clinical chemistry laboratories (one base and two satellite) has been developed as a successor to one used previously. This paper describes both the inadequacies of the previous worksheet-based system and the advantages of the new system, including flexibility, f...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456327901600105

    authors: Hirst AD,Naylor D,White HL,Walter M

    更新日期:1979-01-01 00:00:00

  • Effects of bilirubin and its photoisomers on direct bilirubin measurement using bilirubin oxidase.

    abstract::We examined the reactivity of human serum albumin-bound bilirubin and its photoisomers as substrates for a direct bilirubin assay using bilirubin oxidase. The reduction of (EZ)-cyclobilirubin reached 100% 5 min after addition of the enzyme at any pH tested (3.5-7.4) in 0.1 mol/L phosphate buffer, whereas the reduction...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456320003700404

    authors: Itoh S,Kusaka T,Imai T,Isobe K,Onishi S

    更新日期:2000-07-01 00:00:00

  • Measurement of urinary free cortisol using the Acs:180 serum cortisol chemiluminescent immunoassay.

    abstract::Measurement of urinary free cortisol using the Bayer Automated Chemiluminescent System (ACS:180 PLUS) was evaluated and compared with an in-house extraction radioimmunoassay (RIA). Inter-assay coefficients of variation were acceptable, being respectively 5.3%, 4.8% and 3.8% at 141, 406 and 942 nmol/L (n=20) for the AC...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456320003700414

    authors: Kennedy DM,Selby C,Lawson N

    更新日期:2000-07-01 00:00:00

  • Are biochemistry interpretative comments helpful? Results of a general practitioner and nurse practitioner survey.

    abstract:BACKGROUND:Adding or incorporating clinical interpretative comments on biochemistry results is widespread in UK laboratories; although this consumes considerable human resource, there is still little evidence to suggest that it is either effective or appreciated by our clinical colleagues. I therefore decided to survey...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/acb.2007.007134

    authors: Barlow IM

    更新日期:2008-01-01 00:00:00

  • Detecting anti-SSA and anti-SSB antibodies in routine analysis: a comparison between double immunodiffusion and immunoblotting.

    abstract::The aim of this study was to assess the performance of a commercially available procedure for detecting anti-Sjögren's syndrome A (anti-SSA) and anti-Sjögren's syndrome B (anti-SSB) antibodies by immunoblotting (IB) and compare it with double immunodiffusion (DID). We also studied the clinical significance of these pr...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329903600310

    authors: Yago M,Belmonte MA,Olmos MJ,Beltran J,Teruel C,Segarra M

    更新日期:1999-05-01 00:00:00

  • 17-Hydroxyprogesterone in children, adolescents and adults.

    abstract::17-Hydroxyprogesterone (17-OHP) is an intermediate steroid in the adrenal biosynthetic pathway from cholesterol to cortisol and is the substrate for steroid 21-hydroxylase. An inherited deficiency of 21-hydroxylase leads to greatly increased serum concentrations of 17-OHP, while the absence of cortisol synthesis cause...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/0004563214529748

    authors: Honour JW

    更新日期:2014-07-01 00:00:00

  • Application and validation of a urinary methadone metabolite (EDDP) immunoassay to monitor methadone compliance.

    abstract::A total of 1381 urine specimens were screened using a Microgenics CEDIA urinary primary methadone metabolite (2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine; EDDP) immunoassay (cut-off calibrator concentration of 100 microg/L) in combination with a Dade Behring EMIT urinary methadone immunoassay (cut-off calibrator...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/0004563001899267

    authors: George S,Parmar S,Meadway C,Braithwaite RA

    更新日期:2000-05-01 00:00:00

  • Dual Analyte immunoassay--a new approach to neural tube defect and Down's syndrome screening.

    abstract::A microtiter plate based Dual Analyte enzyme-immunoassay method for the simultaneous measurement of alpha-fetoprotein (AFP) and Free-beta human chorionic gonadotrophin (hCG) was evaluated. This rapid assay, which has application in both Neural Tube Defect screening and Down's screening, shows good precision with betwe...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329202900403

    authors: Macri JN,Spencer K,Anderson R

    更新日期:1992-07-01 00:00:00

  • Comparison of two latex agglutination test kits for serum myoglobin in the exclusion of acute myocardial infarction.

    abstract::The Myolex (Orion) and the RapiTex (Behringwerke) latex agglutination tests for the rapid detection of elevated levels of serum myoglobin were studied prospectively in patients suspected of acute myocardial infarction, who were admitted to hospital within 8 h of pain onset. Using admission blood samples drawn 3.4 +/- ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328902600309

    authors: Konings CH,Funke Küpper AJ,Verheugt FW

    更新日期:1989-05-01 00:00:00

  • Identification of factors limiting the accurate measurement of plasma D-penicillamine in rheumatoid arthritis patients.

    abstract::Free and total reduced concentrations of D-penicillamine have been measured in the plasma of rheumatoid arthritis patients by HPLC and electro-chemical detection. A reverse-phase ion-pair separation in conjunction with a dual porous graphite electrode satisfied the requirements of robustness, sensitivity, selectivity ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328802500210

    authors: Webb BA,Richardson SJ,Haslock I

    更新日期:1988-03-01 00:00:00

  • Comparison of biochemical with radiological findings in renal osteodystrophy.

    abstract::In a group of 121 adult patients with end-stage chronic renal failure who had been undergoing maintenance haemodialysis for up to 10 years a number of biochemical variables have been measured and related to a set of objective radiological changes in the same patients. The changes in plasma calcium, magnesium, phosphat...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456327501200126

    authors: Moorhead JF,Varghese Z,Tatler GL,Baillod RA,Wills MR

    更新日期:1975-05-01 00:00:00

  • The postoperative inflammatory response to injury following laparoscopic assisted vaginal hysterectomy versus abdominal hysterectomy.

    abstract::The magnitude of the inflammatory response to surgery depends on the degree of injury during surgical procedures. Laparoscopic techniques are generally associated with less postoperative pain and shorter hospital stay compared with open procedures, presumably due to less tissue injury and reduced inflammatory response...

    journal_title:Annals of clinical biochemistry

    pub_type: 临床试验,杂志文章

    doi:10.1177/000456329703400509

    authors: Labib M,Palfrey S,Paniagua E,Callender R

    更新日期:1997-09-01 00:00:00

  • Feedback of laboratory usage and cost data to clinicians: does it alter requesting behaviour?

    abstract::In a 1 year prospective study we evaluated the effect of feedback of laboratory data on the requesting behaviour of physicians in general medicine. Data on within-hours and out-of-hours clinical chemistry laboratory usage and revenue expenditure for inpatients and outpatients, expressed in terms of clinical workload, ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329102800204

    authors: Gama R,Nightingale PG,Broughton PM,Peters M,Bradby GV,Berg J,Ratcliffe JG

    更新日期:1991-03-01 00:00:00

  • Monitoring mycophenolic acid.

    abstract::The immunosuppressive agent mycophenolate mofetil is a prodrug for the active compound mycophenolic acid. Following organ transplantation, it is used mostly in combination with other immunosuppressive drugs, but it has also been used as primary therapy. Although in the pivotal clinical studies the drug was given in fi...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/0004563021902035

    authors: Holt DW

    更新日期:2002-05-01 00:00:00

  • Seasonal variation in serum 25-hydroxy vitamin D3 does not affect 1,25-dihydroxy vitamin D.

    abstract::The seasonal variation of serum 25-hydroxy vitamin D3 and 1,25-dihydroxy-vitamin D has been investigated. Blood was taken from 27 healthy volunteers, aged 21-44 years old at 3 monthly intervals over a period of 1 year. A scrolling monthly programme with 12 quarterly (3 month) time periods was developed. A summer assoc...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329403100105

    authors: Hine TJ,Roberts NB

    更新日期:1994-01-01 00:00:00

  • Can we interpret serum thyroglobulin results?

    abstract::Thyroglobulin (Tg) is a tumour marker for differentiated thyroid cancer. Interpretation requires a knowledge of the current thyrotropin (TSH) concentration as secretion is TSH-dependent. While a raised serum Tg may be indicative of residual or recurrent thyroid cancer, trauma to the thyroid (e.g. surgical, biopsy or d...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章,评审

    doi:10.1258/acb.2011.011248

    authors: Clark P,Franklyn J

    更新日期:2012-07-01 00:00:00