Abstract:
:This article describes an application for capturing, delivering, and tracking urgent radiology exam results. Urgent exam findings are entered using a Web form embedded within the Picture archiving and communication system (PACS) display station. The findings are then accessible via soft copy using the PACS display stations, hospital information system (HIS) terminals, or wireless-enabled personal digital assistants (PDAs) or via hard copy printouts that are generated automatically or on demand. Additionally, quality control is performed on those findings entered by radiology residents and fellows, the results of which are used for both performance tracking and educational activities. The application was developed using Sun Microsystems' Java programming language. The Java Message Service (JMS) was used to manage the delivery of findings. JMS provides a robust, flexible framework for exchanging messages between disparate applications. The application is now used for all urgent exams; completely replacing the original paper-based system. The use of JMS provides the necessary level of reliability needed by this application.
journal_name
J Digit Imagingjournal_title
Journal of digital imagingauthors
Tellis WM,Andriole KPdoi
10.1007/s10278-003-1717-0subject
Has Abstractpub_date
2004-06-01 00:00:00pages
80-6issue
2eissn
0897-1889issn
1618-727Xjournal_volume
17pub_type
杂志文章abstract::Cardiovascular disease is the leading cause of global mortality, yet its early detection remains a vexing problem of modern medicine. Although the computed tomography (CT) calcium score predicts cardiovascular risk, relatively high cost ($250-400) and radiation dose (1-3 mSv) limit its universal utility as a screening...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-011-9385-y
更新日期:2012-02-01 00:00:00
abstract::This article presents a review of image quality assessment methods for monochrome CRTs in the field as opposed to the laboratory. The review includes image quality programs at the University of Washington, the University of Texas at Houston, the University of Michigan, and the University of Arizona. CRT manufacturers ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168851
更新日期:1999-11-01 00:00:00
abstract::The purpose of this study was to retrospectively evaluate radiologist performance in detection of lacunar infarcts on T1- and T2-weighted images, without and with the use of a computer-aided diagnosis (CAD) scheme. Thirty T1-weighted and 30 T2-weighted MR images obtained from 30 patients were used for assessing observ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-011-9444-4
更新日期:2012-08-01 00:00:00
abstract::Opinion surveys were gathered before and 6 months after installation of a prototype picture archiving and communication system (PACS) (PACS/1, Siemens Medical Systems, Iselin, NJ). Median turnaround times and the percent of delayed or missing reports were calculated for 1,026 baseline and 8,438 follow-up studies at 6 ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03167836
更新日期:1992-05-01 00:00:00
abstract::In this report, a novel technique is proposed for computer-aided automatic extraction of microcalcifications in a digital mammogram. First, the microcalcifications are detected by morphological filtering, followed by entropy-based thresholding. Next, the microcalcifications are segmented by computing regional watershe...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03167642
更新日期:2000-05-01 00:00:00
abstract::Recently, several types of post-processing image filter which was designed to reduce noise allowing a corresponding dose reduction in CT images have been proposed and these were reported to be useful for noise reduction of CT images of adult patients. However, these have not been reported on adaptation for pediatric p...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-009-9218-4
更新日期:2010-12-01 00:00:00
abstract::Cerebral microbleeds, which are small focal hemorrhages in the brain that are prevalent in many diseases, are gaining increasing attention due to their potential as surrogate markers of disease burden, clinical outcomes, and delayed effects of therapy. Manual detection is laborious and automatic detection and labeling...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-018-0146-z
更新日期:2019-10-01 00:00:00
abstract::Complex deformities of the spine, like scoliosis, are evaluated more precisely using stereo-radiographic 3D reconstruction techniques. Primarily, it uses six stereo-corresponding points available on the vertebral body for the 3D reconstruction of each vertebra. The wireframe structure obtained in this process has poor...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-015-9841-1
更新日期:2016-04-01 00:00:00
abstract::Large PACS (Picture Archiving and Communication Systems) installations do not yet exist in Sweden, but some hospitals have had experience with limited PACS activities. At present there are four mini PACS installations in radiology departments and about 12 teleradiology systems in use in Sweden. A couple of small Swedi...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168157
更新日期:1991-08-01 00:00:00
abstract::Statistics show that the risk of autism spectrum disorder (ASD) is increasing in the world. Early diagnosis is most important factor in treatment of ASD. Thus far, the childhood diagnosis of ASD has been done based on clinical interviews and behavioral observations. There is a significant need to reduce the use of tra...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-019-00196-1
更新日期:2019-12-01 00:00:00
abstract::Successful adoption of new technology development can be accentuated by learning and applying the scientific principles of innovation diffusion. This is of particular importance to areas within the medical imaging practice which have lagged in innovation; perhaps, the most notable of which is reporting which has remai...
journal_title:Journal of digital imaging
pub_type: 杂志文章,评审
doi:10.1007/s10278-011-9409-7
更新日期:2012-02-01 00:00:00
abstract::Today, many hospitals have a running enterprise picture archiving and communication system (PACS) and their administrators should have the tools to measure the system activity and, in particular, how much it is used. The information would be valuable for decision-makers to address asset management and the development ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-016-9870-4
更新日期:2016-12-01 00:00:00
abstract::The Fuhrman nuclear grade is a recognized prognostic factor for patients with clear cell renal cell carcinoma (CCRCC) and its pre-treatment evaluation significantly affects decision-making in terms of management. In this study, we aimed to assess the feasibility of a combined approach of radiomics and machine learning...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-020-00336-y
更新日期:2020-08-01 00:00:00
abstract::In Hokkaido University Hospital, the large-scale PACS has been in clinical use since 1989. We developed various kinds of imaging terminals such as the image input terminal and the image display terminal for this system. This article presents detailed description of these terminals. ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168146
更新日期:1991-11-01 00:00:00
abstract::The authors present a unique medical technical application for illustrating the success and/or failure of the physiological healing process as a dynamically morphed video. Two examples used in this report include the healing of a severely fractured humerus from an explosion in Iraq and the other of dramatic tissue des...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-006-1050-5
更新日期:2007-09-01 00:00:00
abstract::A novel medical image quality index using grey relational coefficient calculation is proposed in this study. Three medical modalities, DR, CT and MRI, using 30 or 60 images with a total of 120 images used for experimentation. These images were first compressed at ten different compression ratios (10 ∼ 100) using a med...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-010-9353-y
更新日期:2011-10-01 00:00:00
abstract::The need for tools to monitor imaging-related radiation has grown dramatically in recent years. RADIANCE, a freely available open-source dose-monitoring tool, was developed in response to the need for an informatics solution in this realm. A number of open-source as well as commercial solutions have since been develop...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-013-9570-2
更新日期:2013-08-01 00:00:00
abstract::There is increasing prevalence of digital diagnostic imaging in veterinary medicine with a progressive need to use medical imaging software. As Digital Imaging and Communications in Medicine (DICOM)-viewers for veterinary use do not require medical device approval in many countries, freeware viewers might be a practic...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-019-00194-3
更新日期:2020-02-01 00:00:00
abstract::This manuscript reviews Touch Surgery, a novel online platform geared towards innovating professional training for surgical procedures. In other industries, such as aviation, simulation has already been shown to reduce costs and improve outcomes in crisis (JETS 3(4):348-352, 2010). Studies involving simulation-based l...
journal_title:Journal of digital imaging
pub_type: 杂志文章,评审
doi:10.1007/s10278-018-0102-y
更新日期:2018-10-01 00:00:00
abstract::Academic medical centers, in general, and radiation oncology research, in particular, rely heavily on custom software tools and applications. The code development is typically the responsibility of a single individual or at most a small team. Often these individuals are not professional programmers but physicists, stu...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-009-9271-z
更新日期:2011-02-01 00:00:00
abstract::The purpose of this study was to develop and evaluate a computerized method of calculating a breast density index (BDI) from digitized mammograms that was designed specifically to model radiologists' perception of breast density. A set of 153 pairs of digitized mammograms (cranio-caudal, CC, and mediolateral oblique, ...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/BF03168733
更新日期:1998-08-01 00:00:00
abstract::Clinical picture archiving and communications systems provide convenient, efficient access to digital medical images from multiple modalities but can prove challenging to deploy, configure and use. MRIdb is a self-contained image database, particularly suited to the storage and management of magnetic resonance imaging...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-013-9604-9
更新日期:2013-10-01 00:00:00
abstract::In this paper, a novel lesion segmentation within breast ultrasound (BUS) image based on the cellular automata principle is proposed. Its energy transition function is formulated based on global image information difference and local image information difference using different energy transfer strategies. First, an en...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-011-9450-6
更新日期:2012-10-01 00:00:00
abstract::High-throughput, large-scale medical image computing demands tight integration of high-performance computing (HPC) infrastructure for data storage, job distribution, and image processing. The Vanderbilt University Institute for Imaging Science (VUIIS) Center for Computational Imaging (CCI) has constructed a large-scal...
journal_title:Journal of digital imaging
pub_type: 杂志文章,评审
doi:10.1007/s10278-018-0080-0
更新日期:2018-06-01 00:00:00
abstract::The purpose of this study is to assess the accuracy, precision, and rapidity of liver volumes calculated by using a freehand electromagnetic pen tablet contourtracing method as compared with the volumes calculated by using the standard optical mouse contourtracing method. The imaging data used as input for accuracy an...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-010-9291-8
更新日期:2011-04-01 00:00:00
abstract::Content-based medical image retrieval (CBMIR) is a powerful resource to improve differential computer-aided diagnosis. The major problem with CBMIR applications is the semantic gap, a situation in which the system does not follow the users' sense of similarity. This gap can be bridged by the adequate modeling of simil...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-015-9809-1
更新日期:2016-02-01 00:00:00
abstract::Liquid crystal displays (LCD) are rapidly replacing cathode ray tube displays (CRT) for medical imaging. LCD technology has improved significantly in the last few years and has important advantages over CRT. However, there are still some aspects of LCD that raise questions as to the usefulness of liquid crystal displa...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-005-2939-0
更新日期:2005-09-01 00:00:00
abstract::There has been increasing interest in adjusting CT radiation dose data for patient body size. A method for automated computation of the abdominal effective diameter of a patient from a CT image has previously only been tested in adult patients. In this work, we tested the method on a set of 128 pediatric patients aged...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-013-9623-6
更新日期:2013-12-01 00:00:00
abstract::Transitioning to a filmless department is no easy task, especially at a large academic medical center. At the University of Medicine and Dentistry of New Jersey-New Jersey Medical School, a phased modality integration schedule was implemented to allow the technical and clinical staff to gradually absorb all of the cha...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-002-5044-7
更新日期:2002-01-01 00:00:00
abstract::This study tracked a radiology department's conversion from utilization of a Kodak Amber analog system to a Kodak DirectView DR 5100 digital system. Through the use of ProModel Optimization Suite, a workflow simulation software package, significant quantitative information was derived from workflow process data measur...
journal_title:Journal of digital imaging
pub_type: 杂志文章
doi:10.1007/s10278-006-0770-x
更新日期:2006-01-01 00:00:00