Cystatin C.

Abstract:

:Clinical biochemists have long known the analytical and clinical limitations of creatinine and creatinine clearance measurement in the assessment of glomerular filtration rate (GFR). This background is reviewed in the article before assessing the utility of cystatin C, the most promising replacement biochemical marker yet identified. Cystatin C has been used in clinical research studies for more than 20 years and yet has been introduced into clinical practice in very few centres, firstly in Lund in Sweden and now Carshalton in the UK. Why is this? The review compares our ability to measure creatinine and cystatin C and their relative sensitivity and specificity for changes in GFR. Comparison is made of cystatin C with creatinine as screening tests for early renal dysfunction and for monitoring its progression where issues of reference ranges and within-individual variation are important. The superiority of cystatin C as a screening test is probably accepted but there are still concerns about non-renal influences upon its circulating concentration, particularly steroid therapy, insufficient data on the influence of malignancy and a general lack of prospective clinical studies confirming the prognostic significance of cystatin C.

journal_name

Ann Clin Biochem

authors

Newman DJ

doi

10.1258/0004563021901847

subject

Has Abstract

pub_date

2002-03-01 00:00:00

pages

89-104

issue

Pt 2

eissn

0004-5632

issn

1758-1001

journal_volume

39

pub_type

杂志文章,评审
  • Comparison of Amerlex, NML, and Ames total thyroxine and triiodothyronine radioimmunoassay kits.

    abstract::An evaluation of the Amerlex system for determination of total thyroxine (T4) and total triiodothyronine (T3) is described. The within- and between-batch precisions were acceptable, and analyses of quality control material and linearity studies demonstrated good accuracy at the clinical decision levels. The correlatio...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328201900208

    authors: Wilke TJ,Turnbull PA

    更新日期:1982-03-01 00:00:00

  • Comparison of sample types for N-terminal pro-B-type natriuretic peptide measured on the Siemens Immulite 2500 and Dimension Vista LOCI methods.

    abstract:BACKGROUND:Measurement of serum natriuretic peptides is recommended in patients with suspected heart failure. Assays for N-terminal pro-B-type natriuretic peptide (NT-proBNP) are available on several platforms and can be measured in serum or heparinized plasma. Siemens Healthcare Diagnostics do not recommend the use of...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/acb.2012.012053

    authors: Peake RW,Turner HE,Leaper W,Deans KA,Hannah A,Croal BL

    更新日期:2012-09-01 00:00:00

  • Influence of age, posture and intra-individual variation on plasma levels of atrial natriuretic peptide.

    abstract::This paper describes some factors to which attention should be paid when atrial natriuretic peptide (ANP) values are to be interpreted. Changing from the supine to the sitting position decreased ANP levels, while no further decrease was observed when the upright position was assumed. On the other hand, plasma renin ac...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328902600604

    authors: Tan AC,Kloppenborg PW,Benraad TJ

    更新日期:1989-11-01 00:00:00

  • Hyperamylasaemia and dual paraneoplastic syndromes in small cell lung cancer.

    abstract::We hereby describe the rare case of a 59-year-old patient presenting with marked hyperamylasaemia mimicking acute pancreatitis upon admission. Investigation of co-existent hypokalemia revealed the presence of ectopic adrenocorticotropic hormone secretion, leading to the final diagnosis of small cell lung cancer, exhib...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/0004563213500658

    authors: Akinosoglou K,Siagris D,Geropoulou E,Kosmopoulou O,Velissaris D,Kyriazopoulou V,Gogos C

    更新日期:2014-01-01 00:00:00

  • 2,8-Dihydroxyadenine renal stones in a 41-year-old man.

    abstract::A case is presented of a 41-year-old man with a history of recurrent renal stones over 10 years. Analysis of the stone showed that, although it gave a positive reaction with the non-specific phosphotungstic acid test, uricase failed to identify any urate present. Analysis in a reference laboratory confirmed its compos...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/000456304322880087

    authors: Wilkinson H,Samuell C,Stower M

    更新日期:2004-03-01 00:00:00

  • Effect of oral supplementation with vitamin E on the oxido-reductive status of red blood cells in normal mice and mice subject to oxidative stress by chronic administration of adriamycin.

    abstract::The effect of oral vitamin E supplementation on the oxido-reductive status of red blood cells in normal mice and those subject to oxidative stress by chronic administration of the anti-tumour drug Adriamycin was investigated. Mice were randomly separated into three groups of 20 animals each and maintained on diets ide...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329903600214

    authors: Thabrew MI,Samarawickrema N,Chandrasena LG,Jayasekera S

    更新日期:1999-03-01 00:00:00

  • Biochemical markers of neonatal sepsis: value of procalcitonin in the emergency setting.

    abstract:BACKGROUND:We evaluated procalcitonin (PCT) assay in the emergency diagnosis of neonatal bacterial infection, especially in preterm infants, relative to C-reactive protein (CRP) and fibrinogen. METHODS:One hundred and twenty neonates (32 preterm), of whom 21 were infected, were tested. RESULTS:Concentrations of PCT, ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/0004563021901874

    authors: Guibourdenche J,Bedu A,Petzold L,Marchand M,Mariani-Kurdjian P,Hurtaud-Roux MF,Aujard Y,Porquet D

    更新日期:2002-03-01 00:00:00

  • Mind the gap: shortcomings of the osmotic gap and a possible solution.

    abstract::Background Measured (MO) and calculated osmotic concentrations (CO) and the osmotic gap (OG) are commonly used in the investigation of electrolyte and volume disturbances as well as in cases of suspected volatile ingestion. Methods We compared 38 published formulae for CO with MO on a large data-set ( n = 9466) and ad...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/0004563217694052

    authors: Wilgen U,Pretorius CJ,Ungerer JP

    更新日期:2018-01-01 00:00:00

  • Why do general practitioners request rheumatoid factor? A study of symptoms, requesting patterns and patient outcome.

    abstract:BACKGROUND:To investigate the reasons why general practitioners (GPs) request rheumatoid factor (RF) assays, we studied 200 consecutive requests for RF from general practice in 1995. METHOD:By means of an audit questionnaire, we studied 100 negative, 50 positive and 50 borderline RF results and compared these with the...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/000456303763046049

    authors: Sinclair D,Hull RG

    更新日期:2003-03-01 00:00:00

  • Establishing reference total serum cholesterol values for Saudi children.

    abstract::Total serum cholesterol was measured in 1320 normal Saudi children aged 0-14 years. The result was 3.88 (0.83) mmol/L [mean (SD)] and there was no statistical difference between girls and boys. Results were lowest in the 0-4 year age group and highest in the 5-9 year age group. Percentile values were established for t...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329403100407

    authors: Rafii ZS,al Nasser AA,Budair A,Tufail M

    更新日期:1994-07-01 00:00:00

  • A method for measuring glycerol-blanked triglyceride concentrations by using gas chromatography-isotope dilution mass spectrometry.

    abstract:BACKGROUND:Serum triglyceride concentrations are measured as total glycerides content in many Western countries. In Japan, glycerol-blanked triglycerides (TG-GB) are measured to identify postprandial hypertriglyceridaemia and to minimize the influence of glycerol formulation on serum triglyceride values. However, TG-GB...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/0004563220921884

    authors: Koyama I,Imano H,Nakamura M,Kitamura A,Kiyama M,Miyamoto Y,Iso H

    更新日期:2020-05-01 00:00:00

  • The costing of tests in a laboratory for clinical chemistry and haematology.

    abstract::The total cost of a haematology and clinical chemistry laboratory, including external and hospital costs, was studied in a district general hospital in The Netherlands. The main conclusion is that the number of samples analysed is the most important cost-setting factor, but that reduction in the number of requests doe...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328402100206

    authors: Leijten JF,van der Geer F,Scholten MN,Goldschmidt HM

    更新日期:1984-03-01 00:00:00

  • Bromocresol purple and the measurement of albumin. Falsely high plasma albumin concentrations eliminated by increased reagent ionic strength.

    abstract::This study was undertaken to investigate the extent of the reported discrepancy between serum and plasma albumin concentrations measured by the bromocresol purple (BCP) method. We have shown that plasma albumin concentrations are falsely increased by turbidity due to the precipitation of fibrinogen when plasma is dilu...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328302000503

    authors: Hill PG,Wells TN

    更新日期:1983-09-01 00:00:00

  • Measurement of bone-specific alkaline phosphatase by an immunoselective enzyme assay method.

    abstract::We evaluated a new immunoselective enzyme assay of bone-specific alkaline phosphatase (ALP). The monoclonal antibody used in this assay was raised against purified bone-specific ALP obtained from SAOS-2 human osteosarcoma cell line. Calibration was based on the enzyme's own activity. The relative activity of the antib...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329603300205

    authors: Hata K,Tokuhiro H,Nakatsuka K,Miki T,Nishizawa Y,Morii H,Miura M

    更新日期:1996-03-01 00:00:00

  • Clinical usefulness of the simultaneous localisation of the isoenzymes of alkaline phosphate and gamma-glutamyl transferase.

    abstract::Simultaneous localisation of the isoenzymes of alkaline phosphatase and gamma-glutamyl transferase was carried out on 173 serum samples from patients with hepatobiliary and bone disease to determine (i) if a better discrimination of the underlying pathology could be obtained by such an approach, and (ii) if the pathol...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328001700104

    authors: Baines M

    更新日期:1980-01-01 00:00:00

  • Two cases of spuriously elevated cerebrospinal glucose concentration.

    abstract::We present two cases of spuriously high cerebrospinal fluid glucose concentration with approximately normal blood glucose concentrations. The cause of these abnormal findings was the use of inappropriate collection tubes during the pre-analytical phase. Whilst no patient harm was identified following this error, signi...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/0004563214547284

    authors: Broz P,Rajdl D,Racek J,Petr T,Vitek L

    更新日期:2015-01-01 00:00:00

  • Effect of ambient temperature on analytical and clinical performance of a blood glucose monitoring system: Omnitest Sensor glucose meter.

    abstract::The effect of ambient temperature on the analytical and clinical performance of a glucose meter was examined. A total of 114 venous whole blood samples were analysed for glucose by a reference method, and by a glucose meter at 21-22 degrees C, room temperatures, 26-27 degrees C and 33-34 degrees C. Glucose meter readi...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/0004563011901091

    authors: Nawawi H,Sazali BS,Kamaruzaman BH,Yazid TN,Jemain AA,Ismail F,Khalid BA

    更新日期:2001-11-01 00:00:00

  • A future for faecal haemoglobin measurements in the medical laboratory.

    abstract::Guaiac-based faecal occult blood tests (gFOBT) are still used in asymptomatic population bowel screening programmes but are being replaced by faecal immunochemical tests (FIT) for haemoglobin. gFOBT have many well-documented disadvantages and there is little evidence for their use in assessment of the symptomatic. Man...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章,评审

    doi:10.1258/acb.2012.012065

    authors: Fraser CG

    更新日期:2012-11-01 00:00:00

  • The influence of a cooked-meat meal on estimated glomerular filtration rate.

    abstract:BACKGROUND:Chronic kidney disease (CKD) is an important but under-recognized condition. Recent national guidelines have recommended that biochemistry laboratories report estimated GFR (eGFR) to improve diagnosis of CKD and facilitate disease staging and management. Previous reports have suggested that intake of large a...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/000456307779595995

    authors: Preiss DJ,Godber IM,Lamb EJ,Dalton RN,Gunn IR

    更新日期:2007-01-01 00:00:00

  • Serum iron and total iron-binding capacity determination by flow-injection analysis with atomic absorption detection.

    abstract::The deproteinised sample (150 microliters) is 'injected' into a continuously flowing stream of deionised water which is pumped, via a capillary tube, to the nebuliser of an atomic absorption spectrophotometer. Analytical readout is obtained, in the form of transient peaks, 6 s after sample injection. Before injection ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328302000202

    authors: Rocks BF,Sherwood RA,Turner ZJ,Riley C

    更新日期:1983-03-01 00:00:00

  • Urinary free catecholamines--diagnostic application of an HPLC technique to the investigation of neural crest tumours.

    abstract::Experience in the use of an in-house urinary free catecholamine assay for the investigation of possible neural crest tumours in a District General Hospital laboratory is described. Elevated excretion of catecholamines and vanillylmandelic acid was found in a number of cases including phaeochromocytoma and neuroblastom...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328702400512

    authors: Davidson DF

    更新日期:1987-09-01 00:00:00

  • The biochemical assessment of insulin resistance.

    abstract::Insulin resistance is a common condition, recognized to be a central feature of the metabolic syndrome, and strongly associated with an increased risk of cardiovascular disease and diabetes. The quantitative assessment of insulin sensitivity is not used for routine clinical purposes, but the emerging importance of ins...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章,评审

    doi:10.1258/000456307780945778

    authors: Borai A,Livingstone C,Ferns GA

    更新日期:2007-07-01 00:00:00

  • The entero-insular axis in polycystic ovarian syndrome.

    abstract::We investigated the contributions made by the entero-insular axis, proinsulin and the fractional hepatic extraction of insulin to the hyperinsulinaemia characteristic of polycystic ovarian syndrome (PCOS). We measured plasma glucose, gastric inhibitory polypeptide (GIP), glucagon-like peptide-1 (7-36 amide) (GLP-1(7-3...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329603300303

    authors: Gama R,Norris F,Wright J,Morgan L,Hampton S,Watkins S,Marks V

    更新日期:1996-05-01 00:00:00

  • Evaluation of 25-hydroxy vitamin D assay on the immunodiagnostic systems iSYS analyser.

    abstract:BACKGROUND:We evaluated the recently released chemiluminescence assay for 25-hydroxy vitamin D (25-OHD) on the Immunodiagnostic Systems iSYS (IDS-iSYS) automated analyser. METHODS:The IDS-iSYS comparison was performed using patient samples previously measured for 25-OHD by a validated liquid chromatography-tandem mass...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1258/acb.2011.011018

    authors: Cluse ZN,Fudge AN,Whiting MJ,McWhinney B,Parkinson I,O'Loughlin PD

    更新日期:2012-03-01 00:00:00

  • Differential response of serum alkaline phosphatase and serum osteocalcin in Paget's osteosarcoma.

    abstract::Serum osteocalcin did not show any response to the onset of osteosarcoma in Paget's disease of bone whereas serum alkaline phosphatase increased rapidly. This suggests that osteocalcin is not useful in the diagnosis and management of Paget's osteosarcoma and does not reflect the same osteoblastic processes in bone as ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456329102800216

    authors: Davie MW,Worsfold M,Sharp CA

    更新日期:1991-03-01 00:00:00

  • Serum and plasma 5-hydroxyindoleacetic acid as an alternative to 24-h urine 5-hydroxyindoleacetic acid measurement.

    abstract:BACKGROUND:Neuroendocrine tumours are slow growing tumours known to secrete a variety of vasoactive peptides which give rise to symptoms of the carcinoid syndrome. The diagnosis and monitoring of patients with neuroendocrine tumours is undertaken in many centres using 24 h urinary measurement of 5-hydroxyindoleacetic a...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/0004563215613109

    authors: Adaway JE,Dobson R,Walsh J,Cuthbertson DJ,Monaghan PJ,Trainer PJ,Valle JW,Keevil BG

    更新日期:2016-09-01 00:00:00

  • Essential data derived from biological variation for establishment and use of lipid analyses.

    abstract::The analytical and biological components of variation of total cholesterol, high density lipoprotein (HDL) cholesterol, HDL3 cholesterol, HDL2 cholesterol and apolipoproteins A-I and B in serum were assessed in 12 apparently healthy individuals. All analytes showed marked individuality and therefore conventional popul...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328902600314

    authors: Ford RP

    更新日期:1989-05-01 00:00:00

  • Investigation of the use of bilirubin oxidase to measure the apparent unbound bilirubin concentration in human plasma.

    abstract::An investigation into the use of bilirubin oxidase to measure the apparent concentration of unbound bilirubin in solutions of bilirubin or bilirubin/human serum albumin demonstrated (1) near linearity of oxidation rate with bilirubin concentration up to 16 mumol/L, (2) linearity with respect to enzyme concentration up...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/000456328802500110

    authors: Goldfinch ME,Maguire GA

    更新日期:1988-01-01 00:00:00

  • Differential extraction of endogenous and exogenous 25-OH-vitamin D from serum makes the accurate quantification in liquid chromatography-tandem mass spectrometry assays challenging.

    abstract:BACKGROUND:Extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis is the method of choice when it comes to the accurate quantification of 25-OH-vitamin D in blood samples. It is generally assumed that the addition of exogenous internal standard allows for the determination of the endo...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章

    doi:10.1177/0004563214533316

    authors: Lankes U,Elder PA,Lewis JG,George P

    更新日期:2015-01-01 00:00:00

  • Assays for prolactin: guidelines for the provision of a clinical biochemistry service.

    abstract::This paper summarises the views of the authors on the provision of a prolactin assay service. We discuss the pathophysiology of prolactin secretion and the clinical indications that arise from that. We cover the rather complex issue of the definition of normal and elevated prolactin levels. From these considerations, ...

    journal_title:Annals of clinical biochemistry

    pub_type: 杂志文章,评审

    doi:10.1177/000456328602300603

    authors: Jeffcoate SL,Bacon RR,Beastall GH,Diver MJ,Franks S,Seth J

    更新日期:1986-11-01 00:00:00