Apolipoprotein E in apolipoprotein B (apo B)- and non-apo B-containing lipoproteins in 3523 participants in the Stanislas cohort: biological variation and genotype-specific reference limits.

Abstract:

BACKGROUND:Apolipoprotein (apo) E is a component of two major classes of plasma lipoproteins, apo B- (apo E-LpB) and non-apo B-containing (apo E-Lp-non-B) lipoproteins. The factors that affect total apo E in particles [lipoprotein E (LpE), apo E-Lp-non-B, and apo E-LpB], are incompletely characterized. METHODS:We studied the determinants of these lipoparticles in a sample population of presumably healthy individuals: 1784 children (age range, 8-18 years) and 1739 adults (age range, 19-50 years). Serum concentrations of LpE and apo E-Lp-non-B were measured by electroimmunoassays, and the concentration of apo E-LpB was calculated by a difference method. RESULTS:Serum LpE and apo E-Lp-non-B were higher in females than in males. Their concentrations decreased with age until 20-25 years and then increased in men but not in women. apo E-LpB concentrations increased up to 20-25 years and were similar in both sexes. Thereafter, adult men had higher values than women. Individuals carrying the epsilon2 allele had higher mean apo E-Lp-non-B concentrations and lower apo E-LpB concentrations than did individuals carrying the epsilon3 allele. Individuals with the epsilon4 allele showed an inverse profile compared with those with the epsilon2 allele. Age, gender, the common apo E polymorphism, puberty, serum lipid concentrations, and alcohol consumption were significantly associated with total LpE, apo E-Lp-non-B, and apo E-LpB concentrations. Reference limits were established according to age, gender, and the common apo E polymorphism. CONCLUSIONS:Because measurements of LpE, apo E-Lp-non-B, and apo E-LpB concentrations may improve cardiovascular risk assessment, the proposed reference limits will aid interpretation of the results in clinical or therapeutic trials.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Schiele F,Vincent-Viry M,Starck M,Beaud B,Hennache G,Siest G,Visvikis S,Herbeth B

subject

Has Abstract

pub_date

2002-02-01 00:00:00

pages

291-300

issue

2

eissn

0009-9147

issn

1530-8561

journal_volume

48

pub_type

杂志文章
  • Performance characteristics of a novel tandem mass spectrometry assay for serum testosterone.

    abstract:BACKGROUND:Commercial immunoassays for testosterone (Te) may give inaccurate results for samples from women and children, leading to misdiagnosis and inappropriate treatment. We developed a sensitive and specific tandem mass spectrometric assay for measurement of Te at the concentrations encountered in women and childr...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.052167

    authors: Kushnir MM,Rockwood AL,Roberts WL,Pattison EG,Bunker AM,Fitzgerald RL,Meikle AW

    更新日期:2006-01-01 00:00:00

  • Microassay of amiodarone and desethylamiodarone in serum by capillary electrophoresis with head-column field-amplified sample stacking.

    abstract::Binary-system capillary electrophoresis (CE) with head-column field-amplified sample stacking permits determination of amiodarone and desethylamiodarone in 20-microL serum samples. The assay is characterized by a detection limit for both compounds of 80 nmol/L and by excellent linear response over the recommended ther...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Zhang CX,Aebi Y,Thormann W

    更新日期:1996-11-01 00:00:00

  • Triclonal gammopathy in a patient with plasma cell dyscrasia.

    abstract::A triclonal gammopathy is an immunoglobulin abnormality in which three discrete monoclonal subpopulations of immunoglobulin molecules are present in a patient's serum. Monoclonal and biclonal gammopathies have been studied extensively, but relatively little is known about the much rarer triclonal gammopathies. The cas...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ray RA,Schotters SB,Jacobs A,Rodgerson DO

    更新日期:1986-01-01 00:00:00

  • Multicenter evaluation of [-2]proprostate-specific antigen and the prostate health index for detecting prostate cancer.

    abstract:BACKGROUND:Total prostate-specific antigen (tPSA) is flawed for prostate cancer (PCa) detection. [-2]proprostate-specific antigen (p2PSA), a molecular isoform of free PSA (fPSA), shows higher specificity compared with tPSA or percentage of free PSA (%fPSA). The prostate health index (Phi), a measure based on p2PSA and ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,多中心研究

    doi:10.1373/clinchem.2012.195784

    authors: Stephan C,Vincendeau S,Houlgatte A,Cammann H,Jung K,Semjonow A

    更新日期:2013-01-01 00:00:00

  • Increase in dialyzable calcium associated with therapy with lithium.

    abstract::We measured total and dialyzable calcium concentrations in consecutive sera submitted for routine lithium analysis. Of 98 samples from 61 different individuals, six (6.1%) total calcium results and 32 (33%) dialyzable calcium results were above the respective reference intervals. By comparison, when both total and dia...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Toffaletti J,McComb RB,Bowers GN Jr

    更新日期:1979-10-01 00:00:00

  • Proteasome inhibition measurements: clinical application.

    abstract:BACKGROUND:PS-341, a selective inhibitor of the proteasome, currently is under evaluation as an anticancer agent in multiple phase I clinical trials. In animal-model studies, PS-341 was rapidly removed from the vascular compartment and distributed widely, quickly approaching the limits of detection. An accurate pharmac...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lightcap ES,McCormack TA,Pien CS,Chau V,Adams J,Elliott PJ

    更新日期:2000-05-01 00:00:00

  • Use of a programmable desk-top calculator for the statistical quality control of radioimmunoassays.

    abstract::We have developed an interactive statistical quality-control system for the small- to medium-sized radioimmunoassay laboratory, which can be used in a programmable desk-top calculator instead of the medium- or large-scale computer systems usually required. The design of this quality-control system is modeled after the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Cernosek SF Jr,Gutierrez-Cernosek RM

    更新日期:1978-07-01 00:00:00

  • Assessing the quality of glucose monitor studies: a critical evaluation of published reports.

    abstract:BACKGROUND:In recent years, a large number of studies have been published on the performance of glucose monitors. The quality of these reports is not known. METHODS:We searched the PubMed database for performance evaluations of handheld glucose monitors published from August 2002 to November 2006. Relevant articles we...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2006.083493

    authors: Mahoney J,Ellison J

    更新日期:2007-06-01 00:00:00

  • MALDI-TOF MS for the diagnosis of infectious diseases.

    abstract:BACKGROUND:First introduced into clinical microbiology laboratories in Europe, MALDI-TOF MS is being rapidly embraced by laboratories around the globe. Although it has multiple applications, its widespread adoption in clinical microbiology relates to its use as an inexpensive, easy, fast, and accurate method for identi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2014.221770

    authors: Patel R

    更新日期:2015-01-01 00:00:00

  • Enzyme-linked immunosorbent assay of apolipoprotein B in blood spotted onto filter paper, suitable for neonatal screening.

    abstract::This assay was developed to measure apolipoprotein (apo) B in blood samples spotted onto filter paper. The long-term aim is to detect young families with the dominantly inherited familial hypercholesterolemia, during current neonatal screening programs. The interassay CV was 5.6%, and apo B concentrations correlated c...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wang XL,Dudman NP,Wilcken DE

    更新日期:1989-06-01 00:00:00

  • Multiple-reaction monitoring-mass spectrometric assays can accurately measure the relative protein abundance in complex mixtures.

    abstract:BACKGROUND:Mass spectrometric assays could potentially replace protein immunoassays in many applications. Previous studies have demonstrated the utility of liquid chromatography-multiple-reaction monitoring-mass spectrometry (LC-MRM/MS) for the quantification of proteins in biological samples, and many examples of the ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2011.173856

    authors: Hoofnagle AN,Becker JO,Oda MN,Cavigiolio G,Mayer P,Vaisar T

    更新日期:2012-04-01 00:00:00

  • Catalytic concentrations of amylase isoenzymes: an assay with wheat-germ inhibitor and 4-nitrophenylmaltopentaoside plus 4-nitrophenylmaltohexaoside as substrate.

    abstract::We coupled a kinetic procedure to a selective inhibiting method for determining amylase isoenzymes in biological samples, using 4-nitrophenylmaltopentaoside plus 4-nitrophenylmaltohexaoside as substrate and a wheat-germ selective inhibitor with the Gilford S-III spectrophotometer. On plotting remaining amylase activit...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jiménez A,Arenas J,Santos I,Martínez A

    更新日期:1986-08-01 00:00:00

  • Development of a marker of estrogenic exposure in human serum.

    abstract::The deleterious, disruptive effects of estrogen mimics on the endocrine system were discovered after the compounds were released into the environment. Their chemical structure does not obviously resemble that of steroid hormones; hence, their estrogenic effects were totally unexpected. In addition to occupational expo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sonnenschein C,Soto AM,Fernandez MF,Olea N,Olea-Serrano MF,Ruiz-Lopez MD

    更新日期:1995-12-01 00:00:00

  • Radioimmunoassay for amatoxins by use of a rapid, 125I-tracer-based system.

    abstract::In this new radioimmunoassay system for determination of amatoxins in urine and plasma, a novel chemical approach is used for antigen and 125I-tracer production, based on a detoxified alpha-amanitin derivative (aldoamanitin). Total assay time, including data processing, is less than 100 min. The lowest detectable conc...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Andres RY,Frei W,Gautschi K,Vonderschmitt DJ

    更新日期:1986-09-01 00:00:00

  • Performance evaluation and subsequent clinical experience with the Abbott Automated Architect STAT Troponin-I assay.

    abstract:BACKGROUND:Cardiac troponins are specific biochemical markers of myocardial injury used in the diagnosis of acute myocardial disease and cardiac risk stratification. To avoid misclassification of patients, troponin assays must demonstrate precision at the low end of the measuring range. We report our evaluation of the ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.057216

    authors: Lam Q,Black M,Youdell O,Spilsbury H,Schneider HG

    更新日期:2006-02-01 00:00:00

  • Review of actual proficiency-testing performance under CLIA '67 (March 14, 1990) rules: perspective from the first year's data.

    abstract::Under the Clinical Laboratory Improvement Act of 1967 the Health Care Financing Administration's proficiency-testing requirement applies to approximately 12,000 hospital, reference, and large-clinic laboratories in the United States. The Wisconsin State Laboratory of Hygiene is approved by the Health Care Financing Ad...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lanphear BJ,Burmeister BJ,Ehrmeyer SS,Laessig RH,Hassemer DJ

    更新日期:1992-07-01 00:00:00

  • Basal and stimulated calcitonin and procalcitonin by various assays in patients with and without medullary thyroid cancer.

    abstract:BACKGROUND:Calcitonin (CT) is a sensitive marker for evaluation of medullary thyroid cancer (MTC). However, CT measurement can vary with assay- and nonassay-dependent factors, and procalcitonin (PCT) measurement has been proposed for evaluating questionable increases in CT. METHODS:We tested 2 fully automated CT assay...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2010.151688

    authors: Kratzsch J,Petzold A,Raue F,Reinhardt W,Bröcker-Preuss M,Görges R,Mann K,Karges W,Morgenthaler N,Luster M,Reiners C,Thiery J,Dralle H,Fuhrer D

    更新日期:2011-03-01 00:00:00

  • LOX index, a novel predictive biochemical marker for coronary heart disease and stroke.

    abstract:BACKGROUND:Lectin-like oxidized LDL receptor 1 (LOX-1) is implicated in atherothrombotic diseases. Activation of LOX-1 in humans can be evaluated by use of the LOX index, obtained by multiplying the circulating concentration of LOX-1 ligands containing apolipoprotein B (LAB) times that of the soluble form of LOX-1 (sLO...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.140707

    authors: Inoue N,Okamura T,Kokubo Y,Fujita Y,Sato Y,Nakanishi M,Yanagida K,Kakino A,Iwamoto S,Watanabe M,Ogura S,Otsui K,Matsuda H,Uchida K,Yoshimoto R,Sawamura T

    更新日期:2010-04-01 00:00:00

  • Diagnosis of type III hyperlipoproteinemia by chromatography of plasma lipoproteins on columns containing agarose.

    abstract::Agarose column chromatography has been used to separate plasma lipoproteins into very-low-density lipoproteins (VLDL), low-density lipoproteins (LDL) and high-density lipoproteins (HDL). Applied to the diagnosis of primary type III hyperlipoproteinemia, the procedure is capable of demonstrating three characteristic an...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Shepherd J,Packard CJ,Dryburgh FJ,Third JL

    更新日期:1975-12-01 00:00:00

  • Manual fluorometry of phenylalanine from blood specimens collected on filter paper: a modified procedure.

    abstract::In this manual fluorometric method, blood samples are used that have been impregnated on the filter paper, a convenient collection technique that is widely used to screen newborns for phenylketonuria. The modified procedure, based on the method of McCaman and Robins [J. Lab Clin. Med. 59, 885 (1962)], includes elution...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wu JT,Wu LH,Ziter FA,Ash KO

    更新日期:1979-03-01 00:00:00

  • Contribution of CYP3A5 to the in vitro hepatic clearance of tacrolimus.

    abstract:BACKGROUND:Tacrolimus is metabolized predominantly to 13-O-demethyltacrolimus in the liver and intestine by cytochrome P450 3A (CYP3A). Patients with high concentrations of CYP3A5, a CYP3A isoenzyme polymorphically produced in these organs, require higher doses of tacrolimus, but the exact mechanism of this association...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.050047

    authors: Kamdem LK,Streit F,Zanger UM,Brockmöller J,Oellerich M,Armstrong VW,Wojnowski L

    更新日期:2005-08-01 00:00:00

  • Determination of sodium and potassium with ion-selective electrodes.

    abstract::We compared different sample-handling techniques for measurement of Na+ and K+ with ion-selective electrodes (ISE). Imprecision was less for venous blood (with a minimum of heparin) than for plasma, serum, or capillary blood. The results for K+ were higher for serum than for whole blood, and higher for whole blood tha...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fogh-Andersen N,Wimberley PD,Thode J,Siggaard-Andersen O

    更新日期:1984-03-01 00:00:00

  • Radioimmunometric assay for a monoclonal antibody-defined tumor marker, CA 19-9.

    abstract::We describe a solid-phase radioimmunometric sandwich assay for a new tumor marker defined by a monoclonal antibody (19-9). This antibody reacts with a carbohydrate antigenic determinant (CA 19-9) found at low concentrations in sera from healthy individuals but frequently increased in sera from patients with adenocarci...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Del Villano BC,Brennan S,Brock P,Bucher C,Liu V,McClure M,Rake B,Space S,Westrick B,Schoemaker H,Zurawski VR Jr

    更新日期:1983-03-01 00:00:00

  • Anaphylaxis in the mouse--a model for using two-dimensional electroimmunodiffusion to study pathological changes in multiple serum proteins simultaneously.

    abstract::Two-dimensional electroimmunodiffusion is rarely used in clinical chemistry, because its potentialities are not yet widely appreciated. Studying mouse anaphylaxis, we observed with this technique certain striking short- and long-term pathologic changes in several important serum antigens, which aptly demonstrate its u...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Quintero S,Crowle AJ

    更新日期:1979-05-01 00:00:00

  • Altered profile of seminal plasma microRNAs in the molecular diagnosis of male infertility.

    abstract:BACKGROUND:Although microRNAs (miRNAs) play essential roles in spermatogenesis, little is known about seminal plasma miRNAs in infertile men. We investigated the profile of seminal plasma miRNAs in infertile men to identify miRNAs that are altered in infertility; we then evaluated their diagnostic value. METHODS:Semin...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2011.169714

    authors: Wang C,Yang C,Chen X,Yao B,Yang C,Zhu C,Li L,Wang J,Li X,Shao Y,Liu Y,Ji J,Zhang J,Zen K,Zhang CY,Zhang C

    更新日期:2011-12-01 00:00:00

  • Time series modeling for quality control in clinical chemistry.

    abstract::Autocorrelation of clinical chemistry quality-control (Q/C) measurements causes one of the basic assumptions underlying the use of Levey-Jennings control charts to be violated and performance to be degraded. This is the requirement that the observations be statistically independent. We present a proposal for a new app...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Alwan LC,Bissell MG

    更新日期:1988-07-01 00:00:00

  • Seasonal and sex variation of high-sensitivity C-reactive protein in healthy adults: a longitudinal study.

    abstract:BACKGROUND:Cross-sectional studies have reported seasonal variation in high-sensitivity C-reactive protein (hsCRP). However, longitudinal data are lacking. METHODS:We collected data on diet, physical activity, psychosocial factors, physiology, and anthropometric measurements from 534 healthy adults (mean age 48 years,...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.111245

    authors: Chiriboga DE,Ma Y,Li W,Stanek EJ 3rd,Hébert JR,Merriam PA,Rawson ES,Ockene IS

    更新日期:2009-02-01 00:00:00

  • Type A viral hepatitis: epidemiology, diagnosis, and prevention.

    abstract::Hepatitis A virus (HAV) infection occurs worldwide and is an important cause of acute viral hepatitis in the US. In this review, I cover the epidemiology, course of infection, clinical manifestations, serological responses, and prevention of this infection. Although most patients completely recover from this disease, ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Lemon SM

    更新日期:1997-08-01 00:00:00

  • Carboxyhemoglobin, cotinine, and thiocyanate assay compared for distinguishing smokers from non-smokers.

    abstract::We compared cotinine, carboxyhemoglobin, and thiocyanate concentrations in blood sampled from 187 cigarette smokers and 181 non-smokers. All three differed significantly between smokers and non-smokers. Cotinine performed best as a test for assessing smoking status, with a sensitivity of 98% as compared with 94% for c...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pojer R,Whitfield JB,Poulos V,Eckhard IF,Richmond R,Hensley WJ

    更新日期:1984-08-01 00:00:00

  • Total error assessment of five methods for cholesterol screening.

    abstract::We report the accuracy, imprecision, total analytical errors, and patient misclassification errors for cholesterol measured from capillary whole blood, venous whole blood, and venous plasma samples by five devices used in public cholesterol screening environments: Reflotron, Vision, Ektachem DT-60, QuickRead, and Lipo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Miller WG,McKenney JM,Conner MR,Chinchilli VM

    更新日期:1993-02-01 00:00:00