Total error assessment of five methods for cholesterol screening.

Abstract:

:We report the accuracy, imprecision, total analytical errors, and patient misclassification errors for cholesterol measured from capillary whole blood, venous whole blood, and venous plasma samples by five devices used in public cholesterol screening environments: Reflotron, Vision, Ektachem DT-60, QuickRead, and Liposcan. None of the methods met the National Cholesterol Education Program (NCEP) performance recommendations of 3% CV with 3% bias. The Vision and Reflotron methods used with venous samples gave individual results with total errors consistent with a combined CV and bias in the 4-5% range; capillary blood samples had total errors > 5% (combined CV and bias criteria). The DT-60 performance was near the 5% total error criterion for capillary samples and was > 5% for venous samples. Misclassification of individuals into desirable or referral groups for venous samples was as great as 5.1% for the DT-60, 5.7% for the Vision, and 7.1% for the Reflotron. Misclassifications for capillary blood samples were as great as 6.7%, 18.3%, and 14.1% for DT-60, Vision, and Reflotron, respectively. The QuickRead and Liposcan results were substantially poorer than those obtained by the other methods.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Miller WG,McKenney JM,Conner MR,Chinchilli VM

subject

Has Abstract

pub_date

1993-02-01 00:00:00

pages

297-304

issue

2

eissn

0009-9147

issn

1530-8561

journal_volume

39

pub_type

杂志文章
  • High-dose alpha-tocopherol therapy does not affect HDL subfractions in patients with coronary artery disease on statin therapy.

    abstract:BACKGROUND:Subfractions of HDL, particularly large HDL (HDL2), are inversely correlated with the severity of coronary artery disease (CAD). alpha-Tocopherol (AT) is the main lipid-soluble antioxidant in plasma. Results of a previous small study (n = 44) suggested that either a combination of an antioxidant cocktail [80...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,随机对照试验

    doi:10.1373/clinchem.2006.078865

    authors: Singh U,Otvos J,Dasgupta A,de Lemos JA,Devaraj S,Jialal I

    更新日期:2007-03-01 00:00:00

  • Multi-wavelength analyses of second-derivative spectra for rapid determination of acetaminophen in serum.

    abstract::Measurement of acetaminophen by analysis of the second derivative of its spectrum is specific and sensitive. The method of extraction and the use of just one phosphate buffer as reagent makes this method very convenient. Readings are reliable from 10 to 1500 mg/L. A turnaround time of 20 min makes this method well sui...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dingeon B,Charvin MA,Quenard MT,Thome H

    更新日期:1988-06-01 00:00:00

  • Increased plasma concentrations of activin a predict intraventricular hemorrhage in preterm newborns.

    abstract:BACKGROUND:Intraventricular hemorrhage (IVH) is a major cause of neurologic disabilities in preterm newborns. We evaluated the use of plasma activin A concentrations to predict the development of perinatal IVH. METHODS:We measured nucleated erythrocyte (NRBC) counts, plasma activin A, hypoxanthine (Hyp), and xanthine ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.065979

    authors: Florio P,Perrone S,Luisi S,Vezzosi P,Longini M,Marzocchi B,Petraglia F,Buonocore G

    更新日期:2006-08-01 00:00:00

  • Buprenorphine and norbuprenorphine in hair of pregnant women and their infants after controlled buprenorphine administration.

    abstract:BACKGROUND:Buprenorphine is under investigation as a pharmacotherapeutic agent for treating opioid dependence in pregnant women. We hypothesized that there would be a relationship between the cumulative maternal dose of buprenorphine during pregnancy and the concentration of buprenorphine and norbuprenorphine in matern...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:10.1373/clinchem.2007.091413

    authors: Goodwin RS,Wilkins DG,Averin O,Choo RE,Schroeder JR,Jasinski DR,Johnson RE,Jones HE,Huestis MA

    更新日期:2007-12-01 00:00:00

  • Type A viral hepatitis: epidemiology, diagnosis, and prevention.

    abstract::Hepatitis A virus (HAV) infection occurs worldwide and is an important cause of acute viral hepatitis in the US. In this review, I cover the epidemiology, course of infection, clinical manifestations, serological responses, and prevention of this infection. Although most patients completely recover from this disease, ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Lemon SM

    更新日期:1997-08-01 00:00:00

  • Ultrasensitive DNA Immune Repertoire Sequencing Using Unique Molecular Identifiers.

    abstract:BACKGROUND:Immune repertoire sequencing of the T-cell receptor can identify clonotypes that have expanded as a result of antigen recognition or hematological malignancies. However, current sequencing protocols display limitations with nonuniform amplification and polymerase-induced errors during sequencing. Here, we de...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1093/clinchem/hvaa159

    authors: Johansson G,Kaltak M,Rîmniceanu C,Singh AK,Lycke J,Malmeström C,Hühn M,Vaarala O,Cardell S,Ståhlberg A

    更新日期:2020-09-01 00:00:00

  • Quantification of serum 1-84 parathyroid hormone in patients with hyperparathyroidism by immunocapture in situ digestion liquid chromatography-tandem mass spectrometry.

    abstract:BACKGROUND:Immunoassays specific for 1-84 parathyroid hormone (PTH) reportedly reflect the bioactivity of PTH; however, PTH immunoassays can be susceptible to interference by cross-reacting PTH fragments. In addition, these assays currently lack standardization. A methodology using immunocapture purification with liqui...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.134643

    authors: Kumar V,Barnidge DR,Chen LS,Twentyman JM,Cradic KW,Grebe SK,Singh RJ

    更新日期:2010-02-01 00:00:00

  • Immunochemical approach to the question of inactive subunits in cases of lactate dehydrogenase B subunit deficiency.

    abstract::If there were enzymatically inactive B subunits in a solution containing lactate dehydrogenase (LD) B4 prepared from the hemolysates of heterozygous individuals with LD-B subunit deficiency, the inactive subunits would compete with normal subunits for antibodies to the B4 subunit. Using the activity of normal LD-B4 as...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Maekawa M,Sudo K,Kanno T

    更新日期:1986-01-01 00:00:00

  • The "HemoQuant" test: a specific and quantitative determination of heme (hemoglobin) in feces and other materials.

    abstract::We describe a new, specific, quantitative method for fecal blood, based on conversion of nonfluorescing heme to fluorescing porphyrins, that obviates serious deficiencies inherent in currently used tests. A two-reagent system is used to determine the two hemoglobin-related fractions that are found in feces. The hot ci...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schwartz S,Dahl J,Ellefson M,Ahlquist D

    更新日期:1983-12-01 00:00:00

  • Fluorometric procedure for determining "lamellar body" phospholipids in the particulate fraction of amniotic fluid after filtration.

    abstract::A rapid (30-min) semiautomated continuous-flow procedure is described for use in assessing the phospholipids of the particulate ("lamellar body") fraction of human amniotic fluid. The method is based on measuring the difference in fluorescence of 1,6,-diphenyl-1,3,5-hexatriene added to amniotic fluid before and after ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Egberts J,Soederhuizen W,Gebhardt DO

    更新日期:1983-02-01 00:00:00

  • Lp-PLA2: a new kid on the block.

    abstract:BACKGROUND:Atherosclerosis is a systemic disease with focal rupture of vulnerable plaque responsible for major clinical events. Several population-based studies indicate an association between lipoprotein-associated phospholipase A2 (Lp-PLA2) and cardiovascular events. Lp-PLA2 is emerging as a biomarker that may be a p...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2006.070672

    authors: Zalewski A,Nelson JJ,Hegg L,Macphee C

    更新日期:2006-09-01 00:00:00

  • Determination of carbamylated hemoglobin by high-performance liquid chromatography.

    abstract::We have developed an HPLC method for measuring carbamylated hemoglobin (CarHb), based on the quantification of valine hydantoin formed from the released NH2-terminal carbamyl valine residue after acid hydrolysis of hemoglobin. In uremia, CarHb is produced by nonenzymatic post-translational modification of the terminal...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kwan JT,Carr EC,Bending MR,Barron JL

    更新日期:1990-04-01 00:00:00

  • Prevalence of high C-reactive protein in persons with serum lipid concentrations within recommended values.

    abstract:BACKGROUND:C-Reactive protein (CRP) has been shown to be a strong predictor of coronary heart disease (CHD) and is being considered in cardiovascular disease risk assessment. The number of normolipidemic individuals who are eligible for evaluation of CRP in overall CHD risk assessment is not known. METHODS:We analyzed...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2004.036004

    authors: Ajani UA,Ford ES,Mokdad AH

    更新日期:2004-09-01 00:00:00

  • Light-chain ratios of immunoglobulins G, A, and M determined by enzyme immunoassay.

    abstract::We describe an enzyme-linked immunosorbent assay for determination of light-chain ratios for IgG, IgA, and IgM in serum. A commercial serum with known overall kappa and lambda concentrations was used as standard. To capture the respective immunoglobulins, we used antibodies to gamma, lambda and mu chains coated onto m...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Chui SH,Lam CW,Lai KN

    更新日期:1990-03-01 00:00:00

  • Evaluation of determination of glucose in urine with some commercially available dipsticks and tablets.

    abstract::Four commercial products for urine glucose determination were evaluated and compared with a quantitative hexokinase procedure. We examined precision, sensitivity, and analytical recovery of glucose from glucose-supplemented urine samples and comparison of methods, using patients' samples. Only "Chemstrip uG" (Bio-Dyna...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bandi ZL,Myers JL,Bee DE,James GP

    更新日期:1982-10-01 00:00:00

  • Preparation of whole blood for liquid scintillation counting.

    abstract::Liquid scintillation counting of 3H-labeled whole-blood samples is severely impaired owing to quenching by blood pigments. In this study, dry oxidation and chemical solubilization followed by decolorization were the two general methods used to eliminate color quenching. Three blood volumes were examined: 0.25, 0.50, a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Moore PA

    更新日期:1981-04-01 00:00:00

  • Specific 125I-radioimmunoassay for cholyglycine, a bile acid, in serum.

    abstract::The concentration of the conjugated bile acid, cholylglycine, in serum is a sensitive and specific indicator of hepatic function. We describe a convenient, specific, and precise radioimmunoassay for cholylglycine, in which 125I-labeled cholylglycyltyrosine is used as tracer. In addition, a blocking agent in the buffer...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Miller P,Weiss S,Cornell M,Dockery J

    更新日期:1981-10-01 00:00:00

  • Strand displacement amplification (SDA) and transient-state fluorescence polarization detection of Mycobacterium tuberculosis DNA.

    abstract::Strand displacement amplification (SDA) is an isothermal, in vitro method of amplifying a DNA sequence for diagnostic purposes. We have combined SDA with fluorescence polarization detection in a closed, homogeneous format. A fluorescently labeled oligodeoxynucleotide detector probe hybridizes to the amplification prod...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Walker GT,Nadeau JG,Linn CP,Devlin RF,Dandliker WB

    更新日期:1996-01-01 00:00:00

  • Proposed reference method for iron in serum used to evaluate two automated iron methods.

    abstract::The manual Reference Method of the Centers for Disease Control for serum iron (CDC/RM/Fe) and a semiautomated adaptation of it were used to evaluate two working methods: one, a detergent solubilization procedure for the Roche Cobas-Bio analyzer, the other, the Kodak Ektachem 700 procedure, based on dry-film technology...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Valcour AA,Krzymowski G,Onoroski M,Bowers GN Jr,McComb RB

    更新日期:1990-10-01 00:00:00

  • Cobalamin deficiency in general practice. Assessment of the diagnostic utility and cost-benefit analysis of methylmalonic acid determination in relation to current diagnostic strategies.

    abstract::Diagnosing cobalamin deficiency is often difficult. We investigated the diagnostic strategies that 224 general practitioners used to assess cobalamin status and the criteria on which they based their decisions to supplement patients. From all serum cobalamin analyses carried out at a single laboratory during 1993, ind...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hølleland G,Schneede J,Ueland PM,Lund PK,Refsum H,Sandberg S

    更新日期:1999-02-01 00:00:00

  • Immunoenzymometric determination of trypsin/alpha 1-protease inhibitor complex in plasma of rats with experimental pancreatitis.

    abstract::The currently available radioimmunoassays of trypsin measure total immunoreactive trypsin (EC 3.1.1.7), which includes both trypsinogen and alpha 1-protease inhibitor-bound trypsin. Hitherto, the only way to differentiate these two forms of trypsin has been to fractionate them on a gel-filtration column. We describe h...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fletcher TS,Tsukamoto H,Largman C

    更新日期:1986-09-01 00:00:00

  • Radioimmunometric assay for a monoclonal antibody-defined tumor marker, CA 19-9.

    abstract::We describe a solid-phase radioimmunometric sandwich assay for a new tumor marker defined by a monoclonal antibody (19-9). This antibody reacts with a carbohydrate antigenic determinant (CA 19-9) found at low concentrations in sera from healthy individuals but frequently increased in sera from patients with adenocarci...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Del Villano BC,Brennan S,Brock P,Bucher C,Liu V,McClure M,Rake B,Space S,Westrick B,Schoemaker H,Zurawski VR Jr

    更新日期:1983-03-01 00:00:00

  • Identification of a new metabolite of astilbin, 3'-O-methylastilbin, and its immunosuppressive activity against contact dermatitis.

    abstract:BACKGROUND:Astilbin is a flavonoid isolated from the rhizome of Smilax glabra. In a previous study, we revealed its unique immunosuppressive activity, a selective inhibition against activated T lymphocytes. This characteristic of astilbin is beneficial for the treatment of human immune diseases. METHODS:We incubated a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.077297

    authors: Guo J,Qian F,Li J,Xu Q,Chen T

    更新日期:2007-03-01 00:00:00

  • Association between the UGT1A1 TA-repeat polymorphism and bilirubin concentration in patients with intermittent claudication: results from the CAVASIC study.

    abstract:BACKGROUND:Bilirubin has antioxidative and cytoprotective properties. Low plasma concentrations of bilirubin are reportedly associated with the development of coronary and cerebrovascular disease, and bilirubin concentrations are strongly correlated with the enzyme activity of the hepatic uridine diphosphate glucuronos...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:10.1373/clinchem.2007.102046

    authors: Rantner B,Kollerits B,Anderwald-Stadler M,Klein-Weigel P,Gruber I,Gehringer A,Haak M,Schnapka-Köpf M,Fraedrich G,Kronenberg F

    更新日期:2008-05-01 00:00:00

  • Effect of plasma triglyceride concentrations on the accuracy of immunoturbidimetric assays of apolipoprotein B.

    abstract::We have studied the influence of triglyceride-rich particles on the analytical bias of apolipoprotein B measurements by various immunoturbidimetric methods. Three commercially available methods grossly overestimate apolipoprotein B in samples with even moderately above-normal triglyceride concentrations. This effect i...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Walmsley TA,Grant S,George PM

    更新日期:1991-05-01 00:00:00

  • Strong association of a single nucleotide substitution in the 3'-untranslated region of the apolipoprotein-CIII gene with common hypertriglyceridemia in Arabs.

    abstract::A potential genetic marker for hypertriglyceridemia and coronary disease, an apolipoprotein-CIII gene allele displaying a single nucleotide substitution, was found in 71% of Arabs with primary hypertriglyceridemia. Over 96% of the unrelated adults possessing this allele showed hypertriglyceridemia. The same allele was...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Taş S

    更新日期:1989-02-01 00:00:00

  • Diagnosis of 5α-reductase 2 deficiency: is measurement of dihydrotestosterone essential?

    abstract:BACKGROUND:5α-Reductase 2 deficiency (5ARD) is a known cause of 46,XY disorders of sex development (DSD). Traditionally, the diagnosis relies on dihydrotestosterone (DHT) measurement, but the results are often equivocal, potentially leading to misdiagnosis. We reviewed alternative approaches for diagnosis of 5ARD. MET...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2012.196501

    authors: Chan AO,But BW,Lee CY,Lam YY,Ng KL,Tung JY,Kwan EY,Chan YK,Tsui TK,Lam AL,Tse WY,Cheung PT,Shek CC

    更新日期:2013-05-01 00:00:00

  • Kinetic serum creatinine assays I. The role of various factors in determining specificity.

    abstract::We studied the specificity of kinetic methods of analysis, with emphasis on creatinine determination. The error contributed by an interferent that reacts with the analytical reagent and absorbs at the wavelength of analysis is shown to be related to the ratio of the equilibrium absorbances of the analyte and interfere...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bowers LD

    更新日期:1980-04-01 00:00:00

  • Accuracy and precision of breath-alcohol measurements for a random subject in the postabsorptive state.

    abstract::The accuracy of estimates of blood-alcohol concentration based on measurements of breath-alcohol concentration in a randomly selected subject by a random quantitative evidential breath-alcohol analyzer is evaluated with respect to the breath analyzer itself, its calibration, and the biological variables of the subject...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Simpson G

    更新日期:1987-02-01 00:00:00

  • "Sandwich" enzyme immunoassay for serum ferritin with polypropylene test tubes as the solid phase.

    abstract::A "sandwich" enzyme immunoassay for ferritin in human serum is described, in which horseradish peroxidase-labeled antibody and a very sensitive chromogen, 2,2'-azino-di(3-ethyl-benzthiazolin-6-sulfonate), are used. The solid phase is polypropylene test tubes treated with glutaraldehyde; immunologic reactions are devel...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Revenant MC

    更新日期:1983-04-01 00:00:00