Effects on radioimmunoassay of digoxin of varying incubation periods for antigen---antibody reaction and varying periods of absorption by dextran-coated charcoal.

Abstract:

:In radioimmunoassay of digoxin by the dextran-coated charcoal method, duration of the incubation period for the antigen-antibody reaction and time allowed for dextran-coated charcoal to absorb the free antigen are critical factors. We compared effects of prolonged periods of absorption on results obtained with five commercial kits. In all cases, the digoxin concentrations increased linearly with absorption time, but the increase varied among kits. Kallestad and New England Nuclear 3h-kits and the Squibb 125I-kit showed less increase (i.e., gave relatively consistent results after various periods of absorption); the Schwarz/Mann 125i-kit and Clinical Assays 3h-kit showed greater increases. Precautionary steps are outlined for radioimmunoassays by this technique.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Kuno-Sakai H,Sakai H

subject

Has Abstract

pub_date

1975-02-01 00:00:00

pages

227-9

issue

2

eissn

0009-9147

issn

1530-8561

journal_volume

21

pub_type

杂志文章
  • Comparison between High-Sensitivity Cardiac Troponin T and Cardiac Troponin I in a Large General Population Cohort.

    abstract:BACKGROUND:Few data compare cardiac troponin T (cTnT) and cardiac troponin I (cTnI) in a general population. We sought to evaluate the distribution and association between cTnT, cTnI, and cardiovascular risk factors in a large general population cohort. METHODS:High-sensitivity cTnT and cTnI were measured in serum fro...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2018.292086

    authors: Welsh P,Preiss D,Shah ASV,McAllister D,Briggs A,Boachie C,McConnachie A,Hayward C,Padmanabhan S,Welsh C,Woodward M,Campbell A,Porteous D,Mills NL,Sattar N

    更新日期:2018-11-01 00:00:00

  • Extended clinical trial and evaluation of glucose determination with the Eastman Kodak Ektachem GLU/BUN Analyzer.

    abstract::We followed the "abbreviated precision protocol" of the National Committee for Clinical Laboratory Standards for the evaluation of precision, accuracy, and carryover in analyses for glucose with the "Ektachem." We analyzed 760 clinical samples by this technique, by the FDA Proposed Class Standard glucose reference met...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Bandi ZL,Fuller JB,Bee DE,James GP

    更新日期:1981-01-01 00:00:00

  • Tartrate-resistant acid phosphatase isoform 5b as serum marker for osteoclastic activity.

    abstract:BACKGROUND:Tartrate-resistant acid phosphatase (AcP) 5b is a marker of osteoclastic activity and bone resorption. Immunoassays for serum TRAcP may lack sensitivity and specificity because of the presence of non-bone isoform 5a. The purpose of this study was to isolate the serum isoforms, quantify their disease-related ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Janckila AJ,Takahashi K,Sun SZ,Yam LT

    更新日期:2001-01-01 00:00:00

  • Totally automated liquid-chromatographic assay for cortisol and associated glucocorticoids in serum, with use of ASTED sample preparation.

    abstract::We describe estimation of total cortisol in serum by HPLC. Incorporation of a new technique to totally automate sample preparation decreases costs. The benefits of HPLC ensure that interferences from other steroids are avoided. The method can also be used to estimate concentrations of other glucocorticoids in serum. ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Turnell DC,Cooper JD,Green B,Hughes G,Wright DJ

    更新日期:1988-09-01 00:00:00

  • A 125I-radioimmunoassay for measuring androstenedione in serum and in blood-spot samples from neonates.

    abstract::We developed a radioimmunoassay with a gamma-emitting radioligand to measure androstenedione in human serum and in dried blood-spot samples from newborns. Antisera were raised in rabbits against androstenedione linked to bovine serum albumin at positions 3, 6, or 11 on the steroid nucleus. Radioligands were prepared b...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Thomson S,Wallace AM,Cook B

    更新日期:1989-08-01 00:00:00

  • Inhibition of stimulated interleukin-2 production in whole blood: a practical measure of cyclosporine effect.

    abstract:BACKGROUND:Prediction of cyclosporine (CSA) efficacy and toxicity in individual patients is difficult. There is no practical, biologically relevant, pharmacodynamic measure of CSA effect. A major effect of CSA is to decrease interleukin-2 (IL-2) production; however, measurement of this effect in isolated lymphocytes as...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Stein CM,Murray JJ,Wood AJ

    更新日期:1999-09-01 00:00:00

  • Determination of beta-choriogonadotropin in human plasma; evaluation and comparison of five "kit" methods.

    abstract::We evaluated five quantitative, commercially available radioimmunoassay methods (Beta-Tec, BIO-RIA, Cambridge Nuclear, Mallinckrodt, and Serono) for rapid determination of the beta-subunit of human choriogonadotropin in serum or plasma. Only three of the kits (Beta-Tec, Mallinckrodt, and Serono) were found suitable fo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Knox BS,McKee JW,Hair PI,France JT

    更新日期:1980-12-01 00:00:00

  • New enzyme-linked immunosorbent assay for glycocalicin in plasma.

    abstract::A new sandwich-type enzyme-linked immunosorbent assay for quantifying glycocalicin, a proteolytic fragment of platelet membrane glycoprotein Ib, is described. The assay is based on the use of two monoclonal antibodies raised against glycoprotein Ib and involves the avidin-biotin technique. The detection limit is 7 mic...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kunishima S,Hayashi K,Kobayashi S,Naoe T,Ohno R

    更新日期:1991-02-01 00:00:00

  • Determination of quinidine by high-performance liquid chromatography.

    abstract::Quinidine in serum was measured at 330 nm, after protein precipitation, with an alkyl phenyl reversed-phase chromatographic column by peak-height determination (external standards.) Sensitivity was 0.3 mg/liter, with linear response to at least 10 mg/liter serum. Interassay precision, measured on 20 consecutive days, ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Powers JL,Sadee W

    更新日期:1978-02-01 00:00:00

  • Influence of O.C.T. embedding compound on determinations of estrogen and progestin receptors in breast cancer.

    abstract::Estrogen receptor (ER) and progestin receptor (PR) concentrations in tumor biopsies are important predictive indicators of a clinical response to endocrine therapy of breast cancer. To assess interference of O.C.T. (optimum cutting temperature) embedding compound in assays of ER and PR by radioligand binding, we deter...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pasic R,Djulbegovic B,Wittliff JL

    更新日期:1989-12-01 00:00:00

  • Assessment of urea and other uremic markers for quantification of dialysis efficacy.

    abstract::To validate azotemic markers as an index for intradialytic changes in solute concentration, we compared eight solutes (pseudouridine, xanthine, hypoxanthine, peak 4, peak 5, p-hydroxyhippuric acid, indoxyl sulfate, and hippuric acid) with five classical azotemic markers (urea, creatinine, uric acid, phosphate, and pot...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Vanholder RC,De Smet RV,Ringoir SM

    更新日期:1992-08-01 00:00:00

  • For goodness' sake: expected therapeutic benefit as a basis for healthcare delivery.

    abstract::The current debate on our healthcare system has focused primarily on the cost of care. Because of drastically rising costs and their burden on our economy, government and the private sector have developed many approaches to reduce these costs. Managed care, special contracting arrangements, and government fiat have al...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Denton TA,Diamond GA

    更新日期:1995-05-01 00:00:00

  • Basal and stimulated calcitonin and procalcitonin by various assays in patients with and without medullary thyroid cancer.

    abstract:BACKGROUND:Calcitonin (CT) is a sensitive marker for evaluation of medullary thyroid cancer (MTC). However, CT measurement can vary with assay- and nonassay-dependent factors, and procalcitonin (PCT) measurement has been proposed for evaluating questionable increases in CT. METHODS:We tested 2 fully automated CT assay...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2010.151688

    authors: Kratzsch J,Petzold A,Raue F,Reinhardt W,Bröcker-Preuss M,Görges R,Mann K,Karges W,Morgenthaler N,Luster M,Reiners C,Thiery J,Dralle H,Fuhrer D

    更新日期:2011-03-01 00:00:00

  • Distribution and correlates of C-reactive protein concentrations among adult US women.

    abstract:BACKGROUND:Understanding the distribution of C-reactive protein (CRP) concentration among adult women in the US helps to establish the magnitude of women at increased risk for cardiovascular disease. METHODS:We examined the distribution and correlates of CRP, using data from 2205 women >or=20 years of age from the Nat...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2003.027359

    authors: Ford ES,Giles WH,Mokdad AH,Myers GL

    更新日期:2004-03-01 00:00:00

  • Optimal reaction conditions for assaying human lactate dehydrogenase pyruvate-to-lactate at 25, 30, and 37 degrees C.

    abstract::Optimal reaction conditions for assaying human lactate dehydrogenase pyruvate-to-lactate were determined for isoenzymes 1 and 5 at 25, 30, and 37 degrees C. Three of the nine different buffers examined--imidazole, triethanolamine, and N-tris(hydroxymethyl)-methyl-2-aminoethane sulfonic acid--are satisfactory. Beta-NAD...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Buhl SN,Jackson KY,Graffunder B

    更新日期:1978-02-01 00:00:00

  • Evaluation of the BMC glucose oxidase/peroxidase-4-aminophenazone-phenol procedure for glucose as adapted to the Technicon SMAC.

    abstract::We evaluated the analytical performance of Trinder's glucose oxidase (EC 1.1.3.4)/peroxidase (EC 1.11.1.7) 4-aminophenazone-phenol method for the quantification of serum glucose as adapted to the Technicon SMAC. Our results correlated well with those by the routine SMAC glucose oxidase/peroxidase 3-methyl-2-benzothiaz...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Purcell GV,Behenna DB,Walsh PR

    更新日期:1979-10-01 00:00:00

  • Semiautomated procedures for evaluation of carbohydrate-deficient transferrin in the diagnosis of alcohol abuse.

    abstract::Carbohydrate-deficient transferrin (CDT) may now be the most valuable biological marker for diagnosis of alcohol abuse. We compared the diagnostic performance of two new CDT tests, Axis %CDT turbidimetric immunoassay (TIA) and Axis %CDT HPLC, against Specialty Laboratories' isoelectric focusing/immunoblotting/laser de...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Bean P,Liegmann K,Løvli T,Westby C,Sundrehagen E

    更新日期:1997-06-01 00:00:00

  • Lactate measured in diluted and undiluted whole blood and plasma: comparison of methods and effect of hematocrit.

    abstract::We evaluated a new analyzer that measures lactate in undiluted whole blood by direct (or undiluted) amperometry [Nova Stat Profile 7 Analyzer (SP7); Nova Biomedical, Waltham, MA] by comparing it with two other analyzers, one for measuring lactate in whole blood by indirect (or diluted) amperometry [Model 2300; Yellow ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Toffaletti J,Hammes ME,Gray R,Lineberry B,Abrams B

    更新日期:1992-12-01 00:00:00

  • Efficient cleavage of conjugates of drugs or poisons by immobilized beta-glucuronidase and arylsulfatase in columns.

    abstract:BACKGROUND:Cleavage of conjugates is an important step in toxicological analysis, especially of urine samples. The aim of this study was to combine the advantages and to reduce the disadvantages of acid hydrolysis and conventional enzymatic hydrolysis procedures. METHODS:beta-Glucuronidase (GRD; EC 3.2.1.31) and aryls...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Toennes SW,Maurer HH

    更新日期:1999-12-01 00:00:00

  • Coagulation and bleeding disorders: review and update.

    abstract::Hemostasis is initiated by injury to the vascular wall, leading to the deposition of platelets adhering to components of the subendothelium. Platelet adhesion requires the presence of von Willebrand factor and platelet receptors (IIb/IIIa and Ib/IX). Additional platelets are recruited to the site of injury by release ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Triplett DA

    更新日期:2000-08-01 00:00:00

  • Use of a reference standard to improve the accuracy and precision of seven kits for determination of ferritin in serum.

    abstract::We assessed the accuracy and precision of seven commercial kits for serum ferritin. The concentration of ferritin as determined by these assays for a liver ferritin reference standard, a human heart ferritin standard, and normal sera correlated highly, but the absolute values varied widely. Use of an international ref...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Iacobello C,Ghielmi S,Belloli S,Arosio P,Albertini A

    更新日期:1984-02-01 00:00:00

  • New Colorimetric reaction for end-point, continuous-flow, and kinetic measurement of urea.

    abstract::A reaction of urea, o-phthalaldehyde and N-(1-naphthyl)ethylenediamine is described for measurement of urea by manual, continuous-flow, and kinetic methods. The continuous-flow system requires 25 mu-l of sample; 40 samples can be analyzed per hour. The kinetic method requires no enzymes, has no lag phase, and has good...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jung D,Biggs H,Erikson J,Ledyard PU

    更新日期:1975-07-01 00:00:00

  • Telomeres and telomerase: biological and clinical importance.

    abstract::We review the present knowledge of telomeres and telomerase with special attention to their role in cell proliferation, cellular senescence, and human aging. We summarize the functional aspects of telomerase in cancer, as well as its role as a useful diagnostic and prognostic tumor marker, and discuss possible approac...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Dahse R,Fiedler W,Ernst G

    更新日期:1997-05-01 00:00:00

  • Detection of apolipoprotein E variants by an oligonucleotide "melting" procedure.

    abstract::An oligonucleotide "melting" procedure was developed whereby we can monitor for a sequence heterogeneity in the gene for apolipoprotein E production. Two oligonucleotides were synthesized, one recognizing the common epsilon 3 allele but not the common epsilon 2 allele, the other recognizing the epsilon 2 allele but no...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Funke H,Rust S,Assmann G

    更新日期:1986-07-01 00:00:00

  • Use of two reporter dyes without interference in a single-tube rapid-cycle PCR: alpha(1)-antitrypsin genotyping by multiplex real-time fluorescence PCR with the LightCycler.

    abstract:BACKGROUND:alpha(1)-Antitrypsin is the major plasma serine protease inhibitor. Its deficiency is mainly associated with the alleles PI*S and PI*Z and can lead to obstructive lung disease in adults and to liver cirrhosis during childhood. METHODS:A multiplex PCR method has been established that uses two sets of primers...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: von Ahsen N,Oellerich M,Schütz E

    更新日期:2000-02-01 00:00:00

  • Screening newborn blood spots for 22q11.2 deletion syndrome using multiplex droplet digital PCR.

    abstract:BACKGROUND:The diagnosis of 22q11 deletion syndrome (22q11DS) is often delayed or missed due to the wide spectrum of clinical involvement ranging from mild to severe, often life-threatening conditions. A delayed diagnosis can lead to life-long health issues that could be ameliorated with early intervention and treatmen...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2014.230086

    authors: Pretto D,Maar D,Yrigollen CM,Regan J,Tassone F

    更新日期:2015-01-01 00:00:00

  • Radial-immunodiffusion assay of human apolipoprotein A-I with use of two monoclonal antibodies combined.

    abstract::We produced and characterized several monoclonal antibodies directed toward human plasma apolipoprotein A-I. Two of them, A-I-12 and A-I-57, individually precipitated purified or native high-density lipoprotein in agarose gel by double immunodiffusion. Because radial immunodiffusion performed with a single monoclonal ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Marcovina S,Di Cola G,Catapano AL

    更新日期:1986-12-01 00:00:00

  • Molar absorptivity and the blank correction factor.

    abstract::In photometry, where both the product formed and one or several reactants absorb light at the same wavelength, the absorbance of the "blank" of the sample at the end of the reaction may be less than that measured at the beginning of the reaction, because of consumption of reactant(s). The blank correction factor for t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kroll MH,Elin RJ

    更新日期:1985-03-01 00:00:00

  • Decrease of free thyroxin in serum of lactating women.

    abstract::We measured thyroid hormones and thyroxin-binding proteins in serum from 62 normal lactating and 52 nonlactating women at three months postpartum, and compared these values with those for 42 nonpregnant control women of similar age. Mean thyroxin concentrations in the lactating and nonlactating women were significantl...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Iwatani Y,Amino N,Tanizawa O,Mori H,Kawashima M,Yabu Y,Miyai K

    更新日期:1987-07-01 00:00:00

  • Interlaboratory/intermethod differences in functional sensitivity of immunometric assays of thyrotropin (TSH) and impact on reliability of measurement of subnormal concentrations of TSH.

    abstract::Clinically relevant interassay precision profiles for thyrotropin (thyroid-stimulating hormone; TSH) were constructed with human serum pools measured over 4-8 weeks by six immunometric assays, in at least two different reagent lots. Functional sensitivities (the concentration at which the interassay CV is < or = 20%) ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Spencer CA,Takeuchi M,Kazarosyan M,MacKenzie F,Beckett GJ,Wilkinson E

    更新日期:1995-03-01 00:00:00