Development of hand eczema in junior hairdressers: an 8-year follow-up study.

Abstract:

:The development of hand eczema was evaluated in an 8-year follow-up study carried out in 51 junior hairdressers. Predisposing factors were investigated. Data were collected by use of a self-administered questionnaire: 74% response. None of the junior hairdressers presented with hand eczema at the start of the survey. After 8 years, however, 51% had developed hand eczema. No significant difference in prevalence of hand eczema was found between practicing and non-practicing hairdressers (58% versus 33%). Development of hand eczema was not related to atopic constitution or nickel sensitivity. Dry skin type was associated with increased risk of developing hand eczema.

journal_name

Contact Dermatitis

journal_title

Contact dermatitis

authors

Majoie IM,von Blomberg BM,Bruynzeel DP

doi

10.1111/j.1600-0536.1996.tb02193.x

subject

Has Abstract

pub_date

1996-04-01 00:00:00

pages

243-7

issue

4

eissn

0105-1873

issn

1600-0536

journal_volume

34

pub_type

杂志文章
  • Guidelines for visualization of cutaneous blood flow by laser Doppler perfusion imaging. A report from the Standardization Group of the European Society of Contact Dermatitis based upon the HIRELADO European community project.

    abstract::This report reviews how to set up a laser Doppler perfusion imaging system intended for visualization of skin blood perfusion, capture images and evaluate the results obtained. A brief summary of related papers published in the literature within the areas of skin irritant and allergy patch testing, microdialysis and s...

    journal_title:Contact dermatitis

    pub_type: 指南,杂志文章,实务指引,评审

    doi:10.1034/j.1600-0536.2002.460301.x

    authors: Fullerton A,Stücker M,Wilhelm KP,Wårdell K,Anderson C,Fischer T,Nilsson GE,Serup J,European Society of Contact Dermatitis Standardization Group.

    更新日期:2002-03-01 00:00:00

  • A hand immersion test under laboratory-controlled usage conditions: the need for sensitive and controlled assessment methods.

    abstract::Exaggerated test conditions were frequently used to investigate the cutaneous tolerance of detergent products in the past. As the sensitivity of newly designed biometric methods is steadily improving, the trend towards more realistic test conditions should be encouraged. A hand immersion test under laboratory-controll...

    journal_title:Contact dermatitis

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1600-0536.1999.tb06010.x

    authors: Paye M,Gomes G,Zerweck CR,Piérard GE,Grove GL

    更新日期:1999-03-01 00:00:00

  • Detection of contact hypersensitivity to topical corticosteroids with hydrocortisone-17-butyrate.

    abstract::We showed earlier that most patients with contact dermatitis due to corticosteroids show cross-reactions when patch tested with hydrocortisone-17-butyrate (H-17-B). To test whether H-17-B could be used for detecting topical corticosteroid allergy, we screened patients undergoing routine patch testing with H-17-B. Pati...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1989.tb04729.x

    authors: Reitamo S,Lauerma AI,Förström L

    更新日期:1989-09-01 00:00:00

  • Skin absorption from patch test systems.

    abstract::The development of topical drug products requires testing for skin toxicology reactions. A variety of patch test systems are available with which chemicals are applied to skin. The purpose of this study was to determine the skin absorption of paraphenylenediamine (PPDA) from a variety of such systems. [14C]-PPDA (1% p...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1987.tb02701.x

    authors: Kim HO,Wester RC,McMaster JA,Bucks DA,Maibach HI

    更新日期:1987-09-01 00:00:00

  • Are opera-house artistes afflicted with contact allergy to colophony and cosmetics?

    abstract::The frequencies of cosmetics intolerance and contact allergy to colophony were investigated among 116 singers and dancers and 16 make-up artists. Participants were interviewed, examined and patch tested with a standard series and materials from the opera house. Common skin lesions were found in 1/3 of participants and...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1995.tb00780.x

    authors: Färm G,Karlberg AT,Lidén C

    更新日期:1995-05-01 00:00:00

  • Chronic irritant contact dermatitis: recovery time in man.

    abstract::Chronic irritant contact dermatitis (ICD) is a common skin disease, especially in the workplace, but determining the recovery time of chronic ICD is not easy. To measure the recovery time of chronic ICD, we examined the skin reactivity to a model surfactant, sodium lauryl sulfate (SLS), on previous chronic ICD and nor...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1034/j.1600-0536.2000.042005264.x

    authors: Choi JM,Lee JY,Cho BK

    更新日期:2000-05-01 00:00:00

  • Sensitive skin: closing in on a physiological cause.

    abstract::The phenomenon of 'sensitive skin' is a relatively recent complaint in which certain individuals report more intense and frequent adverse sensory effects than the normal population upon use of cosmetic (personal-care) products. Originally defined as a minority complaint, sensitive skin is now claimed by a majority of ...

    journal_title:Contact dermatitis

    pub_type: 杂志文章,评审

    doi:10.1111/j.1600-0536.2009.01697.x

    authors: Farage MA,Maibach HI

    更新日期:2010-03-01 00:00:00

  • Gold trichloride and gold sodium thiosulfate as markers of contact allergy to gold.

    abstract::The usefulness of a trivalent gold salt, gold trichloride (GTC), was evaluated as a marker of contact allergy to gold. Patients patch test-positive or patch test-negative to gold sodium thiosulfate (GSTS), 13 subjects of each, were patch tested with dilution series of GTC and equimolar concentrations of GSTS. In order...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.0105-1873.2005.00648.x

    authors: Möller H,Ahnlide I,Gruvberger B,Bruze M

    更新日期:2005-08-01 00:00:00

  • Effect of sodium lauryl sulfate (SLS) on in vitro percutaneous penetration of water, hydrocortisone and nickel.

    abstract::The dose- and time-related effect of sodium lauryl sulfate (SLS) on in vitro percutaneous penetration was studied using 3 radiolabeled tracer compounds with different physicochemical properties: tritiated water, hydrocortisone and nickel. Human cadaver abdominal skin from caucasian women was used as membrane in static...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1995.tb00622.x

    authors: Frankild S,Andersen KE,Nielsen GD

    更新日期:1995-06-01 00:00:00

  • Deodorants: a clinical provocation study in fragrance-sensitive individuals.

    abstract::Deodorants are one of the most marketed types of cosmetics and are frequently reported as a cause of dermatitis, particularly among fragrance-sensitive persons. The aim of this study was to investigate the ability of deodorants, which had previously caused axillary dermatitis in fragrance-mix-sensitive eczema patients...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1998.tb05887.x

    authors: Johansen JD,Rastogi SC,Bruze M,Andersen KE,Frosch P,Dreier B,Lepoittevin JP,White I,Menné T

    更新日期:1998-10-01 00:00:00

  • Occupational contact urticaria and protein contact dermatitis: causes and concomitant airway diseases.

    abstract:BACKGROUND:Contact urticaria (CU) and protein contact dermatitis (PCD) are mainly induced by an immediate, IgE-mediated immunological mechanism. Immediate sensitization is also linked to asthma and/or allergic rhinitis. OBJECTIVES:To report causes of work-induced CU and PCD, and to evaluate the occurrence of concomita...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/cod.12856

    authors: Helaskoski E,Suojalehto H,Kuuliala O,Aalto-Korte K

    更新日期:2017-12-01 00:00:00

  • Efficacy of skin barrier creams (II). Ineffectiveness of a popular "skin protector" against various irritants in the repetitive irritation test in the guinea pig.

    abstract::A popular "skin protector" consisting of an emulsion-like foam of lipophilic and hydrophilic substances (Marly skin) was evaluated in a previously described repetitive irritation guinea pig model. The product failed to inhibit the irritation due to sodium lauryl sulphate and toluene. In striking contrast to the recomm...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1993.tb03486.x

    authors: Frosch PJ,Schulze-Dirks A,Hoffmann M,Axthelm I

    更新日期:1993-08-01 00:00:00

  • Dansyl chloride labelling of stratum corneum: its rapid extraction from skin can predict skin irritation due to surfactants and cleansing products.

    abstract::The irritation potential of surfactants and body cleansing products was determined by evaluating the removal of dansyl chloride from the skin. Dilute solutions (2% active ingredient, w/v) of surfactants and soap extract fluorescence from the skin within 30 min. This is probably a physicochemical effect as it is too ra...

    journal_title:Contact dermatitis

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1600-0536.1994.tb00570.x

    authors: Paye M,Simion FA,Pierard GE

    更新日期:1994-02-01 00:00:00

  • Release of thiurams and carbamates from rubber gloves.

    abstract::A method for quantitative determination of thiuram and carbamate derivatives released from rubber gloves into synthetic sweat is presented. The analysis was based upon determination of ester derivatives using gas-chromatography/mass spectrometry and isotope-dilution. The detection limit was 0.1 mg thiuram/carbamate in...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1993.tb03343.x

    authors: Knudsen BB,Larsen E,Egsgaard H,Menné T

    更新日期:1993-02-01 00:00:00

  • Allergy to lanolin.

    abstract::The purpose of the present study was to compare the frequency of lanolin allergy during two periods and to assess the adequacy of testing with one standard allergen. Among 1230 consecutive patients with eczema who were standard patch tested, 33 (2.7%), 21 females and 12 males, gave a positive reaction to wool alcohols...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1979.tb04824.x

    authors: Mortensen T

    更新日期:1979-05-01 00:00:00

  • Nickel dermatitis from cheap earrings.

    abstract::In 1988, 64% of our patients patch test positive to at least 1 allergen of the ICDRG standard series were nickel sensitive. In 70% of 300 patients evaluated, dermatitis started on the earlobes and was related to the regular wearing of cheap earrings. At the same time, 62% of 735 young schoolgirls were found to have de...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1989.tb03203.x

    authors: Santucci B,Ferrari PV,Cristaudo A,Cannistraci C,Picardo M

    更新日期:1989-10-01 00:00:00

  • Sodium metabisulfite--a marker for cosmetic allergy?

    abstract::A 45-year-old woman developed dermatitis of the face after she applied a cosmetic package comprising day and night creams. Patch tests were performed with the British Contact Dermatitis Society (BCDS) standard, bases + preservatives, and cosmetic series in addition to samples of both creams and the individual constitu...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.2007.00972.x

    authors: Malik MM,Hegarty MA,Bourke JF

    更新日期:2007-04-01 00:00:00

  • Airborne contact dermatitis in gaitas (flageolets) constructors after exposure to sawdust of caviuna.

    abstract::Exotic wood species are used in the manufacture of furniture, musical instruments, tool handles, and other wooden items. Exposure to sawdust of the wood can produce dermatitis on exposed areas in woodworkers. We studied 7 patients, gaitas constructors who used caviuna wood to make their instruments. They developed der...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.2007.01095.x

    authors: Rojas-Hijazo B,Lezaun A,Hausen BM,Segura N,Mar Garcés M,Colás C

    更新日期:2007-05-01 00:00:00

  • Sensitization potential of benzotriazole.

    abstract::Predictive guinea pig sensitization studies have been performed with commercial and purified 1H-benzotriazole. In only 3 animals, induced and challenged according to the maximization protocol with more than 100 times the normal use concentration, were slight erythemas elicited with the commercial grade of benzotriazol...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1984.tb00024.x

    authors: Maurer T,Meier F

    更新日期:1984-03-01 00:00:00

  • Laser Doppler perfusion imaging for the documentation of flare-up in contact allergy to gold.

    abstract::A healed or healing allergic contact dermatitis is easily reactivated to a flare-up if the patient is provoked systemically with his particular allergen. 5 patients with contact allergy to gold were patch tested with a serial dilution of gold sodium thiosulfate. 1 to 2 months later, when positive test reactions were h...

    journal_title:Contact dermatitis

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1600-0536.1999.tb06103.x

    authors: Möller H,Björkner B,Bruze M,Lundqvist K,Wollmer P

    更新日期:1999-09-01 00:00:00

  • Influence of the vehicle on elicitation of contact allergic reactions to acrylic compounds in the guinea pig.

    abstract::Many factors can influence the elicitation of hypersensitivity reactions in guinea pigs and humans. The effect which the vehicle might have on the test response in guinea pigs sensitized with various acrylic compounds, using the "guinea pig maximization test", has been investigated. A marked decrease in the number of ...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1984.tb01008.x

    authors: Björkner B,Niklasson B

    更新日期:1984-11-01 00:00:00

  • Prevalence and 1-year outcome of facial allergic contact dermatitis in patients patch tested in a university hospital.

    abstract::Little is known about the prognosis of facial allergic contact dermatitis (FACD). The objective of the study was to investigate the prevalence and 1-year outcome of FACD in patients patch tested. 655 consecutive patients patch tested with European standard series in Peking University Hospital in a 2-year period were s...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.2007.01198.x

    authors: Li LF,Liu G,Wang J

    更新日期:2007-09-01 00:00:00

  • Allergic and irritant patch test reactions and atopic disease.

    abstract::This study presents a profile of patients with chronic recalcitrant eczematous disease referred by dermatologists for contact allergy evaluation. Allergic contact dermatitis (ACD) and irritant responses were carefully defined, as was the presence or absence of atopy obtained by history. Of 410 patients studied, 44% ha...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1996.tb02143.x

    authors: Klas PA,Corey G,Storrs FJ,Chan SC,Hanifin JM

    更新日期:1996-02-01 00:00:00

  • Occupational allergic contact dermatitis caused by colophonium.

    abstract:BACKGROUND:Colophonium is a common contact allergen that is present not only in household products but also in occupational settings. OBJECTIVES:To describe the sources of occupational exposure to colophonium and the occupations at risk of colophonium allergy. METHODS:We reviewed patch test files from the years 2002 ...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/cod.13114

    authors: Pesonen M,Suuronen K,Suomela S,Aalto-Korte K

    更新日期:2019-01-01 00:00:00

  • Occupational contact dermatitis from Cichorium (chicory, endive) and Lactuca (lettuce).

    abstract::In two cases, occupational contact dermatitis was found to be due to chicory (Cichorium) used as a salad plant. In one of the two cases, contact sensitivity to letuce (Lactuca) was also observed. The sesquiterpene lactones of the plant may be the allergens. ...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1975.tb05444.x

    authors: Friis B,Hjorth N,Vail JT Jr,Mitchell JC

    更新日期:1975-10-01 00:00:00

  • Investigation of contact allergy to dental metals in 206 patients.

    abstract:BACKGROUND:Contact allergy to dental materials is poorly understood; clinical manifestations are heterogeneous. OBJECTIVE:To analyse positive patch test reactions to metals (as their alloys or salts) used in dentistry together with clinical symptoms and possible relevance to dental fillings. METHODS:We retrospectivel...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.2009.01524.x

    authors: Raap U,Stiesch M,Reh H,Kapp A,Werfel T

    更新日期:2009-06-01 00:00:00

  • Frequency of sensitization to 13 common preservatives in Switzerland. Swiss Contact Dermatitis Research Group.

    abstract::From February 1989 to January 1990, the Swiss Contact Dermatitis Research Group conducted a 1-year study to examine the frequency of sensitization to a series of 13 common preservatives. A group of 2295 consecutive outpatients with suspected allergic contact dermatitis (age range 7-90 years, with a mean age of 42; 911...

    journal_title:Contact dermatitis

    pub_type: 杂志文章,多中心研究,评审

    doi:10.1111/j.1600-0536.1994.tb00597.x

    authors: Perrenoud D,Bircher A,Hunziker T,Suter H,Bruckner-Tuderman L,Stäger J,Thürlimann W,Schmid P,Suard A,Hunziker N

    更新日期:1994-05-01 00:00:00

  • Contact dermatitis from the epoxy resins tetraglycidyl-4,4'-methylene dianiline and o-diglycidyl phthalate in composite material.

    abstract::An outbreak of dermatitis occurred in an aircraft factory using epoxy resin composite material. Of 25 operatives, 14 gave positive patch test reactions to the composite material and/or diglycidylether of bisphenol A (DGEBA), tetraglycidyl-4,4'-methylene dianiline (TGMDA), and o-diglycidyl phthalate. This report seems ...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1984.tb00931.x

    authors: Burrows D,Fregert S,Campbell H,Trulsson L

    更新日期:1984-08-01 00:00:00

  • Contact allergy to denture materials in the burning mouth syndrome.

    abstract::Several factors may be responsible for stomatitis in general and the burning mouth syndrome in particular. The results of patch testing are reported in 4 patients with burning mouth symptoms thought to be due to sensitization to denture material. 2 patients reacted to substances in Luxene dentures, but the allergens w...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1988.tb02748.x

    authors: van Joost T,van Ulsen J,van Loon LA

    更新日期:1988-02-01 00:00:00

  • Nickel-elicited systemic contact dermatitis from a peripheral intravenous catheter.

    abstract::Nickel-elicited systemic contact dermatitis is a well-known entity, although it is far less common than allergic contact dermatitis. In most of the cases, the main way of nickel administration is oral. Clinical manifestations are miscellaneous including pompholyx, diffuse exanthema, flexural dermatitis or baboon syndr...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.0105-1873.2005.00689.x

    authors: Raison-Peyron N,Guillard O,Khalil Z,Guilhou JJ,Guillot B

    更新日期:2005-10-01 00:00:00