Influence of zoom factor on centre-of-rotation of the SPECT system and on the resolution of tomographic images.

Abstract:

:The influence of zooming on centre-of-rotation (COR) of the rotating camera-based SPECT system and on the resolution of tomographic images was investigated. COR values were measured as a function of zoom factor varying from x1.0 to x3.0. Measurements were performed using two SPECT systems collimated with three collimators. In this study, the COR was observed to shift linearly with zoom factor. The influence of zooming on COR depends on the location and the deviation of the COR from the axis-of-rotation (AOR). We recommend that the deviation of the COR from the AOR be kept to within 0.4 pixels corresponding to 2.4 mm. Unlike zooming, the magnitude of COR shift is uncorrelated to the type of collimator used. Contrast and spatial resolution variations of the tomographic images were quantitated as a function of COR shift for clinical data acquired using no zoom factor and a zoom factor of 2.50. The resolution indices were observed to be more sensitive to COR shift for clinical data acquired using no zoom factor. The sensitivity appeared to be inversely dependent on the zoom factor utilized. However, zooming was found not to preserve the same resolution degradation. Optimum resolution images can be reconstructed by requiring the COR be determined and clinical study be acquired using the same zoom factor and collimator. For qualitative evaluation of tomographic images, the zoom factor requirement can be removed provided that the deviation of the COR from the AOR is within the recommended limit. This limit allows for a maximum spatial resolution degradation of 5%.(ABSTRACT TRUNCATED AT 250 WORDS)

journal_name

Nucl Med Commun

authors

Saw CB,Clarke LP,Serafini AN

doi

10.1097/00006231-198701000-00002

subject

Has Abstract

pub_date

1987-01-01 00:00:00

pages

3-10

issue

1

eissn

0143-3636

issn

1473-5628

journal_volume

8

pub_type

杂志文章
  • Measurement uncertainty of lesion and reference mediastinum standardized uptake value in lung cancer.

    abstract:OBJECTIVE:To assess standardized uptake value (SUV) measurement uncertainty (MU) of lung cancer lesions with uptake greater than mediastinum but less than or equal to the liver and that of the mediastinum blood pool, and to compare lesion SUV with mediastinum SUV by assessing MU of their ratio. PATIENTS AND METHODS:Dy...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000677

    authors: Laffon E,Milpied N,Marthan R

    更新日期:2017-06-01 00:00:00

  • 18F-Flourodeoxy glucose PET-computed tomography in testicular carcinoma: diagnostic and prognostic value.

    abstract:AIM:This study aims to assess the diagnostic role of F-FDG PET/computed tomography in primary staging and restaging of testicular cancer in comparison with contrast-enhanced diagnostic thoracic-abdominopelvic computed tomography. MATERIAL AND METHOD:Thirty-two consecutive male patients with testicular carcinoma (media...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000001093

    authors: Soydal C,Araz M,Urun Y,Gulpinar B,Nak D,Ozkan E,Kucuk NO

    更新日期:2019-12-01 00:00:00

  • A review of captopril renal scintigraphy and its effect on patient management.

    abstract::Renal artery stenosis is an important and potentially curable cause of hypertension. Captopril renography is now recognized to have a high sensitivity and specificity in its diagnosis. Ultimately, however, the result is of little benefit if it does not lead to a change in patient management. To assess how patient mana...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199707000-00006

    authors: Ramsay D,Belton I,Finlay D

    更新日期:1997-07-01 00:00:00

  • Prognostic value of neutrophil-to-lymphocyte ratio and its correlation with fluorine-18-fluorodeoxyglucose metabolic parameters in intrahepatic cholangiocarcinoma submitted to 90Y-radioembolization.

    abstract:OBJECTIVE:The aim of this study was to investigate the prognostic value of neutrophil-to-lymphocyte ratio (NLR) and its relationship with several metabolic parameters obtained through PET in intrahepatic cholangiocarcinoma (ICC) submitted to radioembolization with Y-microspheres (Y-radioembolization). METHODS:Records ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000001123

    authors: Filippi L,Di Costanzo GG,Tortora R,Pelle G,Saltarelli A,Marino Marsilia G,Cianni R,Schillaci O,Bagni O

    更新日期:2020-01-01 00:00:00

  • Clinical relevance of 18F-FDG-negative osteoblastic metastatic bone lesions noted on PET/CT in breast cancer patients.

    abstract:PURPOSE:Our study aims to assess the clinical relevance of fluorine-18 fluorodeoxyglucose (F-FDG) negative osteoblastic metastatic bone lesions noted on PET/computed tomography (CT) in breast cancer patients. PATIENTS AND METHODS:The medical records of breast cancer patients were reviewed retrospectively from January ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000481

    authors: Al-Muqbel KM,Yaghan RJ,Al-Omari MH,Rousan LA,Dagher NM,Al Bashir S

    更新日期:2016-06-01 00:00:00

  • Investigating the histopathologic correlates of 18F-FDG PET heterogeneity in non-small-cell lung cancer.

    abstract:PURPOSE:Despite the growing use of fluorine-18-fluorodeoxyglucose (F-FDG) PET texture analysis to measure intratumoural heterogeneity in cancer research, the biologic basis of F-FDG PET-derived texture variables is poorly understood. We aimed to assess correlations between F-FDG PET-derived texture variables and whole-...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/MNM.0000000000000925

    authors: Bashir U,Foot O,Wise O,Siddique MM,Mclean E,Bille A,Goh V,Cook GJ

    更新日期:2018-12-01 00:00:00

  • Interpretation, accuracy and management implications of FDG PET/CT in cutaneous malignant melanoma.

    abstract:PURPOSE:To investigate the accuracy of different interpretative approaches and to evaluate the management implications of fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) in cutaneous malignant melanoma. METHODS:We retrospectively identified 60 consecutive patients who underwent 76 PET/...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/MNM.0b013e3280708ecf

    authors: Falk MS,Truitt AK,Coakley FV,Kashani-Sabet M,Hawkins RA,Franc B

    更新日期:2007-04-01 00:00:00

  • Validation of the CT iterative reconstruction technique for low-dose CT attenuation correction for improving the quality of PET images in an obesity-simulating body phantom and clinical study.

    abstract:OBJECTIVE:The aim of this study was to validate the efficacy of computed tomography (CT) iterative reconstruction (CT-IR) for low-dose CT attenuation correction in terms of the estimation of attenuation coefficient and quality of PET images. MATERIALS AND METHODS:We used normal and obesity-simulating body phantoms. PE...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000326

    authors: Matsutomo N,Nagaki A,Sasaki M

    更新日期:2015-08-01 00:00:00

  • Initial observations of 99mTc labelled locked nucleic acids for antisense targeting.

    abstract:BACKGROUND AND OBJECTIVE:The most recent DNA analogues to become commercially available are known as locked nucleic acids (LNAs). The aim of this study was to evaluate the properties of LNAs for antisense targeting. METHODS:A 15 mer LNA antisense to RIalpha mRNA was studied in cell culture. The antisense LNA (5'-amine...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200411000-00008

    authors: Zhang Y,He J,Liu G,Venderheyden JL,Gupta S,Rusckowski M,Hnatowich DJ

    更新日期:2004-11-01 00:00:00

  • Synthesis and characterization of 99Tcm-p-halophenethyl diaminodithiol analogs.

    abstract::In an effort to develop new, clinically useful 99Tcm-diaminodithiol (99Tcm-DADT) complexes for the evaluation of regional cerebral perfusion, basic diaminodithiols (DADT-TM, DADT-HM and DADT-MHM) and three diaminodithiol ligands functionalized with p-iodophenethyl (DADT-IPE), N-ethyl-p-fluorophenethyl amine (DADT-EFPE...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199112000-00007

    authors: Shiba K,Mori H,Matsuda H,Hisada K

    更新日期:1991-12-01 00:00:00

  • RET gene mutation analysis and long-term clinical outcomes of medullary thyroid cancer patients.

    abstract:OBJECTIVE:Medullary thyroid carcinoma is a rare, potentially aggressive tumour, with relatively worse prognosis than well-differentiated thyroid cancer. We evaluated the long-term outcomes and prognosis of medullary thyroid carcinoma patients at a single institution in India and compared outcomes based on results of RE...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000001264

    authors: Prabhu M,Shakya S,Ballal S,Ahmed Shamim S,Bal C

    更新日期:2020-11-01 00:00:00

  • Reproducibility of gastric emptying of a pancake and milkshake meal in normal subjects.

    abstract::Comparisons of gastric emptying between different centres are difficult because of wide variations in methods. Reproducibility of a method is very important before it is used to compare different subjects or to assess the effect of treatment. The aim of this study was to measure the reproducibility of gastric emptying...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199801000-00011

    authors: Kong MF,Perkins AC,King P,Blackshaw PE,Macdonald IA

    更新日期:1998-01-01 00:00:00

  • Comparison of 2D and 3D performance for FDG PET with different acquisition times in oncological patients.

    abstract:OBJECTIVE:Collecting positron emission tomography data in three-dimensional (3D) mode may potentially allow reduction of the tracer dose and/or the acquisition time without compromising image quality thereby making the procedure more patient-friendly and cost effective. The objective of our study was to compare VUE Poi...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/mnm.0b013e328315a22a

    authors: Komar G,Teräs M,Seppänen M,Hirvonen J,Vahlberg T,Bergman J,Minn H

    更新日期:2009-01-01 00:00:00

  • Adrenal scintigraphy in Cushing's syndrome caused by bilateral hyperplasia, adenoma or carcinoma.

    abstract::The results of scintigraphy in 29 patients with Cushing's syndrome were evaluated. It was possible to separate bilateral hyperplasia from unilateral abnormality. In cases of unilateral abnormality correct localization of the tumour was accomplished and it was possible to visualize adrenocortical carcinoma. The many ad...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198501000-00005

    authors: Lindberg S,Ernest I,Fjälling M,Holmdahl C

    更新日期:1985-01-01 00:00:00

  • Comparison between visual and numerical metrics for the evaluation of patients with Takayasu arteritis with 18F-FDG-PET.

    abstract:INTRODUCTION:The choice of metrics for defining active Takayasu arteritis (TAK) using fluorine-18-fluorodeoxyglucose (F-FDG)-PET remains controversial. OBJECTIVE:The aim of this study was to compare in the same patients the diagnostic performance for the detection of active TAK of different metrics applied for the qua...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000867

    authors: Emsen B,Benali K,Mahida B,Larivière D,Le Guludec D,Papo T,Sacre K,Hyafil F

    更新日期:2018-08-01 00:00:00

  • A new method for the radiochemical purity measurement of ¹¹¹In-pentetreotide.

    abstract:OBJECTIVES AND METHODS:The recommended method for the measurement of radiochemical purity (RCP) of ¹¹¹In-labelled pentetreotide is thin-layer chromatography with a silica gel as the stationary phase and a 0.1 N sodium citrate solution (pH 5) as the mobile phase. According to the supplier's instructions, the mobile phas...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e32834a7003

    authors: Salgado-Garcia C,Montoza-Aguado M,Luna-Alcaide AB,Segovia-Gonzalez MM,de Mora ES,Lopez-Martin J,Ramos-Font C,Jimenez-Heffernan A

    更新日期:2011-12-01 00:00:00

  • Phagocytosis and dynamic RES scintigraphy: an evaluation of commercial colloids in rats.

    abstract::Reticuloendothelial system (RES) phagocytic function or capacity can be measured by clearance studies with test substances. This study in the rat examines three commercially available 99Tcm-labelled test substances, and different methods of calculating RES capacity. Albures size 500 nm and sulphur colloid size 600 nm ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198705000-00004

    authors: Holmberg SB,Hafström L,Jacobsson L

    更新日期:1987-05-01 00:00:00

  • Observation of changes in peripheral T-lymphocyte subsets by flow cytometry in patients with liver cancer treated with radioimmunotherapy.

    abstract::An analysis of lymphocyte subsets was performed in 24 patients with surgically verified unresectable hepatocellular carcinoma (HCC). In all cases, the hepatic artery was cannulated and ligated and a single dose of 131I-Hepama-1 monoclonal antibody (MAb) was infused through a hepatic artery catheter. Blood samples were...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-199505000-00010

    authors: Zeng ZC,Tang ZY,Liu KD,Yu YQ,Yang BH,Cai XJ,Xie H,Cao SL

    更新日期:1995-05-01 00:00:00

  • Diagnostic accuracy of 18F-FDG PET/CT in characterizing ovarian lesions and staging ovarian cancer: correlation with transvaginal ultrasonography, computed tomography, and histology.

    abstract:AIMS:To (a) assess the accuracy of 18F-FDG PET/CT in distinguishing malignant from benign pelvic lesions, compared to transvaginal ultrasonography (TVUS) and (b) to establish the role of whole-body 18F-FDG PET/CT, compared to contrast enhanced computed tomography (CT), in staging patients with ovarian cancer. PATIENTS...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/MNM.0b013e3281afa256

    authors: Castellucci P,Perrone AM,Picchio M,Ghi T,Farsad M,Nanni C,Messa C,Meriggiola MC,Pelusi G,Al-Nahhas A,Rubello D,Fazio F,Fanti S

    更新日期:2007-08-01 00:00:00

  • Predictive approaches for post-therapy PET/CT in patients with extranodal natural killer/T-cell lymphoma: a retrospective study.

    abstract:PURPOSE:The aim of this study was to assess the prognostic capacity of three methods of fluorine-18-fluorodeoxyglucose (F-FDG) PET/CT analysis carried out after therapy in patients with extranodal natural killer/T-cell lymphoma (ENKTL). The three methods of PET/CT analysis included the International Harmonization Proje...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000731

    authors: Jiang C,Liu J,Li L,Kosik RO,Su M,Zou L,Tian R

    更新日期:2017-11-01 00:00:00

  • Changes in septal regional ejection fraction early and late following coronary artery bypass grafting in patients without postoperative myocardial infarction.

    abstract::Changes in regional ejection fraction (rEF) of the interventricular septum following coronary artery bypass graft (CABG) surgery were examined using first-pass radionuclide ventriculography (RNVG) in patients without objective evidence of postoperative myocardial infarction (MI). One hundred and one patients had pre- ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:

    authors: Jacobson AF,Tow DE,Lapsley D,Khuri S

    更新日期:1992-10-01 00:00:00

  • A method of radionuclide angiography and comparison with contrast aortography in the assessment of aorto-iliac disease.

    abstract::Forty-four patients with symptoms of lower limb arterial insufficiency were examined by radionuclide angiography using 99Tcm in vivo red cell labelling and by contrast aortography. The results of the study indicate that radionuclide angiography may well have a useful role to play in determining the type of contrast st...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198601000-00006

    authors: Grime JS,Critchley M,Whitehouse GH,Zavras G

    更新日期:1986-01-01 00:00:00

  • Radiolabelled monoclonal antibodies in oncology. III. Radioimmunotherapy.

    abstract::The requirements, problems and progress of radioimmunotherapy in the management of certain malignancies are described. The future prospects using a two- or three-stage approach are promising. ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章,评审

    doi:

    authors: Britton KE,Mather SJ,Granowska M

    更新日期:1991-04-01 00:00:00

  • Immediate 201Tl reinjection: an alternative approach in myocardial perfusion scintigraphy? A comparison with contrast angiographic findings.

    abstract::Thallium-201 (201Tl) stress-redistribution/reinjection imaging provides a reliable diagnostic approach in patients evaluated for myocardial ischaemia. Immediate reinjection of 201Tl after completing the stress images followed by imaging 1 h later shortens the investigation time to 2.5 h and may provide a novel approac...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:

    authors: van Eck-Smit BL,van der Wall EE,Zwinderman AH,Pauwels EK

    更新日期:1995-10-01 00:00:00

  • Prediction of lymph node metastasis by PET/CT metabolic parameters in patients with esophageal squamous cell carcinoma.

    abstract:OBJECTIVE:The aim of this study was to investigate the capability of F-FDG PET/computed tomography (CT)-related metabolic parameters to predict lymph node metastasis (LNM) and occult lymph node metastasis (OLNM) in patients with esophageal squamous cell carcinoma (ESCC). METHODS:Totally 84 patients undergoing curative...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000001050

    authors: Xu M,Wang L,Ouyang M,Lin J,Wang L,Zheng X,Miao S,Tang K

    更新日期:2019-09-01 00:00:00

  • Diagnostic value of PET/CT is similar to that of conventional MRI and even better for detecting small peritoneal implants in patients with recurrent ovarian cancer.

    abstract:OBJECTIVE:The aim of this study was to evaluate the diagnostic value of 2-(fluorine-18)-fluoro-2-deoxy-D-glucose ((18)F-FDG) PET/CT in comparison with MRI for the detection of recurrent ovarian cancer. METHODS:Forty-seven patients with suspected ovarian cancer recurrence after total ablative or cytoreductive surgery, ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e32834fc5bf

    authors: Sanli Y,Turkmen C,Bakir B,Iyibozkurt C,Ozel S,Has D,Yilmaz E,Topuz S,Yavuz E,Unal SN,Mudun A

    更新日期:2012-05-01 00:00:00

  • Evaluation of 99Tcm-teboroxime scintigraphy for the differentiation of reversible from fixed defects: comparison with 201T1 redistribution and reinjection imaging.

    abstract::The aim of this study was to compare 99Tcm-teboroxime and 201T1 myocardial studies with particular regard to the classification of perfusion defects as reversible or fixed. Twenty patients with a history of previous myocardial infarction and suspected effort ischaemia underwent exercise 201T1 scintigraphy with early (...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199307000-00002

    authors: Bisi G,Sciagrà R,Santoro GM,Zerauschek F,Fazzini PF

    更新日期:1993-07-01 00:00:00

  • A comparative study of 123I-IMP SPET and CT in the investigation of chronic-stage head trauma patients.

    abstract::The aims of this study were (1) to compare N-isopropyl-p-[I-123]-iodoamphetamine (123I-IMP) SPET with computed tomography (CT) in chronic-stage head trauma patients with neurological abnormalities and (2) to quantify regional cerebral blood flow (rCBF) in patients with chronic-stage head trauma. 123I-IMP SPET and CT w...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199501000-00006

    authors: Nagamachi S,Nishikawa T,Ono S,Kawasaki K,Eguchi G,Hoshi H,Jinnouchi S,Ohnishi T,Futami S,Watanabe K

    更新日期:1995-01-01 00:00:00

  • 99Tcm-MIBI single photon emission tomography (SPET) for detecting myocardial ischaemia and necrosis in patients with significant coronary artery disease.

    abstract::The ability of 99Tcm-methoxyisobutylisonitrile (MIBI) single photon emission tomography (SPET) to detect myocardial ischaemia and necrosis was assessed in 56 patients (45 male, 11 female, aged 55 +/- 5 years), with clinically recognized ischaemic heart disease (IHD). All underwent coronary angiography (CA) and left ve...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199212000-00004

    authors: Sciammarella MG,Fragasso G,Gerundini P,Maffioli L,Cappelletti A,Margonato A,Savi A,Chierchia S

    更新日期:1992-12-01 00:00:00

  • PET-CT imaging features that differentiate between positive and negative EWSR1 translocation in Ewing sarcoma.

    abstract:OBJECTIVES:Ewing sarcoma breakpoint region 1 (EWSR1) translocation-negative tumors represent a minor portion of small round cell tumors consistent with Ewing sarcoma morphology. The purpose of this study was to differentiate EWSR1 translocation-positive tumors from EWSR1 translocation-negative tumors using PET-computed...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000001031

    authors: Soffer S,Amitai MM,Weizen R,Retter A,Barshack I,Shimon O,Davidson T,Klang E

    更新日期:2019-08-01 00:00:00