Identification and evaluation of a new nucleic acid amplification test target for specific detection of Mycobacterium tuberculosis.

Abstract:

BACKGROUND:Accurate and early diagnosis of tuberculosis (TB) is of major importance in the management and control of TB. Because the conventional bacteriological diagnosis of TB has several limitations, nucleic acid amplification (NAA) tests have emerged as promising alternatives. A potential problem with NAA tests is that some strains lack a target, which may be the one of main reasons for the much lower and highly variable accuracy in diagnosis. A possible solution may be to use more valid and applicable targets to increase detection accuracy. METHODS:In this paper, we designed a two-step program to obtain NAA test targets. Inter-simple sequence repeats (ISSR) based on oligonucleotide (GTG)(5) were first constructed to genotype Mycobacterium strains to obtain Mycobacterium tuberculosis (MTB)-specific fragment. Second, sequence characterized amplified region (SCAR) markers were developed from these species-specific sequences to identify MTB. Some 312 Mycobacterium strains were used to evaluate the efficacy of the SCAR markers, IS6110 element [specific identification of Mycobacterium tuberculosis complex (MTC)] and 16SrRNA gene (specific identification of Mycobacterium) amplification, together with traditional bacteriology testing was used as a control. RESULTS:MTB-specific sequences located in a gene coding for Rv1508c, as a new NAA test target, were obtained using ISSR-PCR genotyping. Based on these sequences, the SCAR primer pairs MISP1 and MISP2 were designed. All 312 strains from Mycobacterium accurately produced the genus-specific 16SrRNA amplicon. 271 MTB strains and M. africanum were positive. However, all nontuberculous mycobacteria (NTM) strains and 1 MTB strain named 1143 were negative in both SCAR and IS6110 PCR amplification. M. bovis, bacille Calmette-Guérin (BCG) were IS6110-PCR positive, while SCAR-PCR was negative. Strain 1143 was defined as M. arupense with 99% identity by 16SrRNA gene sequencing identification, despite being diagnosed as MTB using traditional testing. CONCLUSIONS:SCAR markers developed with this two-step program can be used as a new NAA test target to correctly detect MTB.

journal_name

Clin Chem Lab Med

authors

Qin L,Zheng R,Fan C,Cai J,Liu Z,Wang J,Lu J,Jin R,Yang H,Cui Z,Feng Y,Hu Z

doi

10.1515/CCLM.2010.296

subject

Has Abstract

pub_date

2010-10-01 00:00:00

pages

1501-5

issue

10

eissn

1434-6621

issn

1437-4331

journal_volume

48

pub_type

杂志文章
  • Can age and sex related reference intervals be derived for non-healthy and non-diseased individuals from results of measurements in primary health care?

    abstract::Reference intervals in clinical chemistry are commonly based on results of measurements in reference populations or are taken from the literature. A reference population should represent a defined group of individuals and be as similar as possible to the patients under investigation. Frequently, reference populations ...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2000.093

    authors: Kallner A,Gustavsson E,Hendig E

    更新日期:2000-07-01 00:00:00

  • Bone marrow microvascular density and angiogenic growth factors in multiple myeloma.

    abstract::There is evidence that angiogenesis plays an important role in the progression of multiple myeloma (MM). Hepatocyte growth factor (HGF) and tumor necrosis factor-alpha (TNF-alpha) are cytokines that potently stimulate angiogenesis. We evaluated the microvascular density (MVD) of bone marrow biopsies (after immunostain...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2004.230

    authors: Alexandrakis MG,Passam FJ,Ganotakis E,Dafnis E,Dambaki C,Konsolas J,Kyriakou DS,Stathopoulos E

    更新日期:2004-01-01 00:00:00

  • Performance of strip-based glucose meters and cassette-based blood gas analyzer for monitoring glucose levels in a surgical intensive care setting.

    abstract:BACKGROUND:We verified the analytical performance of strip-based handheld glucose meters (GM) for prescription use, in a comparative split-sample protocol using blood gas samples from a surgical intensive care unit (ICU). METHODS:Freestyle Precision Pro (Abbott), StatStrip Connectivity Meter (Nova), ACCU-CHEK Inform I...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2014-1289

    authors: Claerhout H,De Prins M,Mesotten D,Van den Berghe G,Mathieu C,Van Eldere J,Vanstapel F

    更新日期:2016-01-01 00:00:00

  • Towards harmonization of external quality assessment/proficiency testing in hemostasis.

    abstract::Quality in diagnostic testing represents a key target of laboratory medicine, for which an assurance around the quality of testing is expected from all involved in the process. Laboratories attempt to assure the quality of their testing by various processes, but especially by performance of internal quality control an...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2018-0077

    authors: Favaloro EJ,Jennings I,Olson J,Van Cott EM,Bonar R,Gosselin R,Meijer P

    更新日期:2018-12-19 00:00:00

  • Using multiples of the median to normalize serum protein measurements.

    abstract::Quantification of serum proteins is useful in the diagnosis and clinical management of many disorders. With the introduction of automated analyzers and standardized reference materials, one of the last barriers to more widespread utilization of these measurements is the lack of availability of reliable and transferabl...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2001.180

    authors: Palomaki GE,Neveux LM

    更新日期:2001-11-01 00:00:00

  • Immunoassay of anti-thyroid autoantibodies: high analytical variability in second generation methods.

    abstract::The use of highly sensitive immunometric methods in clinical laboratories to assay anti-thyroid antibodies has progressively expanded in recent years but it is not known whether the new techniques have improved the analytical variability connected with the preceding methodologies. The Italian Society of Laboratory Med...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2002.098

    authors: Tozzoli R,Bizzaro N,Tonutti E,Pradella M,Manoni F,Vilalta D,Bassetti D,Piazza A,Rizzotti P,Italian Society of Laboratory Medicine (SIMeL) Study Group on the Laboratory Diagnosis of Autoimmune Diseases.

    更新日期:2002-06-01 00:00:00

  • Highly accurate and explainable detection of specimen mix-up using a machine learning model.

    abstract::Background Delta check is widely used for detecting specimen mix-ups. Owing to the inadequate specificity and sparseness of the absolute incidence of mix-ups, the positive predictive value (PPV) of delta check is considerably low as it is labor consuming to identify true mix-up errors among a large number of false ale...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2019-0534

    authors: Mitani T,Doi S,Yokota S,Imai T,Ohe K

    更新日期:2020-02-25 00:00:00

  • Fetal hemoglobin: assessment of glycation and acetylation status by electrospray ionization mass spectrometry.

    abstract:BACKGROUND:Electrospray ionization mass spectrometry (ESI-MS) can be used for the measurement of glycated adult hemoglobin. Here, we describe the evaluation of ESI-MS for measurement of glycated (GHbF) and acetylated (AcHbF) fetal hemoglobin and the identification by mass of different chains of fetal hemoglobin. METHO...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2008.257

    authors: Davison AS,Green BN,Roberts NB

    更新日期:2008-01-01 00:00:00

  • Unexpected high plasma cobalamin : proposal for a diagnostic strategy.

    abstract::It is well-established that more than 8% of patients examined for vitamin B12 deficiency unexpectedly have increased plasma levels of the vitamin, but so far there are no guidelines for the clinical interpretation of such findings. In this review, we summarise known associations between high plasma cobalamin and disea...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章,评审

    doi:10.1515/cclm-2012-0545

    authors: Arendt JF,Nexo E

    更新日期:2013-03-01 00:00:00

  • The Human Genome Project: from mapping to sequencing.

    abstract::Until recently, the "human genome" programs were mainly directed towards the development of maps to identify disease genes. The genetic map comprises about 8000 highly informative second generation markers of the microsatellite type. The density of markers is now sufficient to localize a gene for a monogenic disease w...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.1998.086

    authors: Weissenbach J

    更新日期:1998-08-01 00:00:00

  • May thrombopoietin be a useful marker of sepsis severity assessment in patients with SIRS entering the emergency department?

    abstract:BACKGROUND:Thrombopoietin (TPO), a growth factor primarily involved in regulating thrombopoiesis, has been recently implicated in the pathogenesis of sepsis. TPO levels are, indeed, greatly increased in patients with sepsis compared to control subjects, and correlate with sepsis severity. The aim of this study was to e...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章,多中心研究

    doi:10.1515/cclm-2014-0219

    authors: Segre E,Pigozzi L,Lison D,Pivetta E,Bosco O,Vizio B,Suppo U,Turvani F,Morello F,Battista S,Moiraghi C,Montrucchio G,Lupia E

    更新日期:2014-10-01 00:00:00

  • Continuous analysis in extracorporeally circulating blood--a rat model applying flow-through ion-selective electrodes for the measurement of Ca2+, K+, Na+ and pH.

    abstract::A rat model is introduced which enables investigations in anticoagulated blood with continuous measurements by a flow-through electrode system. In the present study, a potentiometric ion-selective electrode (ISE)-system was used for measuring Ca2+, K+, Na+ and pH in rats. The setup was adjusted to an extracorporeal bl...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.1998.149

    authors: Heidrich JP,Niemeier A,Seyfarth M

    更新日期:1998-11-01 00:00:00

  • Performance analysis of the ARCHITECT anti-cyclic citrullinated peptide antibody in the diagnosis of rheumatoid arthritis.

    abstract:BACKGROUND:Anti-cyclic citrullinated peptide (CCP) antibody is emerging as an important diagnostic marker for rheumatoid arthritis (RA). We evaluated the analytical and diagnostic performance of the ARCHITECT anti-CCP (Abbott Diagnostics), a new fully automated chemiluminescent microparticle immunoassay. METHODS:Serum...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2010.046

    authors: Hwang SM,Kim JO,Yoo YM,Shin S,Kim JQ,Park MH,Song EY

    更新日期:2010-02-01 00:00:00

  • Persistent hepatitis G virus (HGV) infection in chronic hemodialysis patients and non-B, non-C chronic hepatitis.

    abstract::Three groups of patients have been studied longitudinally for 24 months to analyze the role of hepatitis G virus (HGV) in hepatic disease. Group 1 consisted of 50 patients with non-B, non-C chronic hepatitis, group 2 consisted of 44 hemodialyzed patients, and group 3 consisted of 50 healthy blood donors. The presence ...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2001.154

    authors: Grassi M,Mammarella A,Sagliaschi G,Granati L,Musca A,Traditi F,Pezzella M

    更新日期:2001-10-01 00:00:00

  • Measurement of arginine derivatives in pediatric patients with chronic kidney disease using high-performance liquid chromatography-tandem mass spectrometry.

    abstract:BACKGROUND:The arginine derivatives asymmetric dimethylarginine (ADMA) and symmetric dimethylarginine (SDMA) interfere with endothelial nitric oxide synthesis. Plasma ADMA and SDMA have been shown to be risk factors for cardiovascular disease and/or kidney function deterioration in a variety of patient populations. ME...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2007.277

    authors: Wang S,Vicente FB,Miller A,Brooks ER,Price HE,Smith FA

    更新日期:2007-01-01 00:00:00

  • Certification of reference materials for detection of the human prothrombin gene G20210A sequence variant.

    abstract:BACKGROUND:There is a need for reference materials (RMs) in the field of genetic testing for verification of test results obtained in patients and probands. For the frequent genetic variation G20210A in the prothrombin gene, it has been shown that purified plasmids containing the gene fragment harbouring the mutation c...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2008.093

    authors: Gancberg D,Corbisier P,Meeus N,Marki-Zay J,Mannhalter C,Schimmel H

    更新日期:2008-01-01 00:00:00

  • Characterization of monoclonal antibodies to human protein 1/Clara cell 10 kilodalton protein.

    abstract::Human protein 1/Clara cell Mr 10,000 protein consists of two identical subunits of seventy amino acid residues each. In the present study, eight clones of monoclonal antibodies against native protein 1 were prepared and their respective epitopes were immunochemically and immunohistochemically characterized using nativ...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.1999.098

    authors: Yamaguchi T,Yamada T,Okutani R,Shijubo N,Singh G,Itoh Y

    更新日期:1999-06-01 00:00:00

  • PATHFAST NT-proBNP (N-terminal-pro B type natriuretic peptide): a multicenter evaluation of a new point-of-care assay.

    abstract:BACKGROUND:The biochemical determination of cardiac natriuretic peptides, primarily brain natriuretic peptide (BNP) and the amino-terminal fragment of its pro-hormone proBNP (NT-proBNP), are reliable tools for diagnosing cardiac disease, establishing prognosis and evaluating the effectiveness of treatment. These biomar...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章,多中心研究

    doi:10.1515/CCLM.2010.222

    authors: Zaninotto M,Mion MM,Di Serio F,Caputo M,Ottomano C,Plebani M

    更新日期:2010-07-01 00:00:00

  • Increased level of circulating U2 small nuclear RNA fragments indicates metastasis in melanoma patients.

    abstract:UNLABELLED:Background: Melanoma is the most aggressive skin cancer and, despite recent advances in therapy, about 20% of the patients die of their disease. Early relapse detection and monitoring of therapy response are crucial for efficient treatment of advanced melanoma. Thus, there is a need for blood-based biomarker...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2014-1064

    authors: Kuhlmann JD,Wimberger P,Wilsch K,Fluck M,Suter L,Brunner G

    更新日期:2015-03-01 00:00:00

  • The function of oxalic acid in the human metabolism.

    abstract::Biochemical reactions in cells which involve oxalic acid are described. It is shown that this compound is required for the formation of uracil and orotic acid. The former is a component of RNA which is common to all cells in the human metabolism. On the basis of the biochemical reactions described a possible treatment...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2011.238

    authors: Robertson DS

    更新日期:2011-09-01 00:00:00

  • Hypothesis on interferences in kinetic interaction of microparticles in solution (KIMS) technology.

    abstract::The present paper describes an evaluation of the interferences found with an immunochemical drug test performed during a workplace control. During the period 1993-2003 more than 200,000 urine samples from workers were examined by the Italian Air Force. Samples were screened for drugs of abuse (opiates, cocaine, cannab...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2006.142

    authors: De Giovanni N,Fucci N

    更新日期:2006-01-01 00:00:00

  • A candidate reference method using ICP-MS for sweat chloride quantification.

    abstract:BACKGROUND:The aim of the study was to develop a method for sweat chloride (Cl) quantification using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) to present to the Joint Committee for Traceability in Laboratory Medicine (JCTLM) as a candidate reference method for the diagnosis of cystic fibrosis (CF). METHODS...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2015-0506

    authors: Collie JT,Massie RJ,Jones OA,Morrison PD,Greaves RF

    更新日期:2016-04-01 00:00:00

  • Urinary iodine concentrations of pregnant women in Ukraine.

    abstract:BACKGROUND:Iodine requirements increase during pregnancy and previous studies have reported the inadequate iodine status of pregnant women in areas that have achieved iodine sufficiency in the general population. We examined the urinary iodine (UI) concentrations of pregnant women in Ukraine, where the iodine status is...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2012-0397

    authors: Sekitani Y,Hayashida N,Takahashi J,Kozlovsky AA,Rudnitskiy S,Petrova A,Gutevych OK,Chorniy SA,Yamashita S,Takamura N

    更新日期:2013-04-01 00:00:00

  • Rapid susceptibility testing of multi-drug resistant Escherichia coli and Klebsiella by glucose metabolization monitoring.

    abstract::Background The increasing number of multi-drug resistant (MDR) bacteria provides enormous challenges for choosing an appropriate antibiotic therapy in the early phase of sepsis. While bacterial identification has been greatly accelerated by the introduction of matrix-assisted laser desorption ionization-time of flight...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2018-1178

    authors: Kittel M,Findeisen P,Ghebremedhin B,Miethke T,Grundt A,Ahmad-Nejad P,Neumaier M

    更新日期:2019-07-26 00:00:00

  • Concentration of leukocyte elastase in plasma and polymorphonuclear neutrophil extracts in type 2 diabetes.

    abstract::The concentration of leukocyte elastase/alpha1-proteinase inhibitor complexes in plasma and polymorphonuclear neutrophil extracts, and plasma trypsin inhibitory capacity were determined in 88 patients with type 2 diabetes and 47 control subjects. Higher values of these variables were found in patients as compared to c...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2000.198

    authors: Piwowar A,Knapik-Kordecka M,Warwas M

    更新日期:2000-12-01 00:00:00

  • A candidate reference method for serum potassium measurement by inductively coupled plasma mass spectrometry.

    abstract:BACKGROUND:Potassium is an important serum ion that is frequently assayed in clinical laboratories. Quality assurance requires reference methods; thus, the establishment of a candidate reference method for serum potassium measurements is important. METHODS:An inductively coupled plasma mass spectrometry (ICP-MS) metho...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2016-0803

    authors: Yan Y,Han B,Zeng J,Zhou W,Zhang T,Zhang J,Chen W,Zhang C

    更新日期:2017-08-28 00:00:00

  • Long-term biological variability of galectin-3 after heart transplantation.

    abstract:BACKGROUND:Galectin-3 is an emerging biomarker of heart failure and of myocardial fibrosis risk. Monitoring of galectin-3 is essential during treatment with galectin-3 inhibitors. The aim of our study was to assess long-term biological variability in a specific group of unhealthy subjects. METHODS:The biological varia...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 临床试验,杂志文章

    doi:10.1515/cclm-2013-1088

    authors: Franeková J,Kubíček Z,Hošková L,Kotrbatá M,Sečník P,Kautzner J,Jabor A

    更新日期:2015-01-01 00:00:00

  • Laboratory testing for activated protein C resistance: rivaroxaban induced interference and a comparative evaluation of andexanet alfa and DOAC Stop to neutralise interference.

    abstract::Background Investigation of hemostasis is problematic when patients are on anticoagulant therapy. Rivaroxaban especially causes substantial interference, extending many clot-based tests, thereby leading to false positive or negative events. In particular, rivaroxaban affects some assays for activated protein C resista...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2019-1160

    authors: Favaloro EJ,Gilmore G,Bonar R,Dean E,Arunachalam S,Mohammed S,Baker R

    更新日期:2020-07-28 00:00:00

  • C-reactive protein to transthyretin ratio for the early diagnosis and follow-up of postoperative infection.

    abstract::The clinical usefulness of C-reactive protein (CRP) and of transthyretin (TTR) for the early diagnosis and follow-up of infection after an open fracture was prospectively investigated (cohort A). It was complemented by a retrospective study of trauma patients admitted to an intensive care unit (cohort B). Serial deter...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2002.230

    authors: Férard G,Gaudias J,Bourguignat A,Ingenbleek Y

    更新日期:2002-12-01 00:00:00

  • Quantitative determination of erythrocyte folate vitamer distribution by liquid chromatography-tandem mass spectrometry.

    abstract:BACKGROUND:Given the role of folate in many disorders, intracellular distribution of folate vitamers is of potential clinical importance. In particular, accumulation of non-methyltetrahydrofolates due to altered partitioning of folate metabolism at the level of methylenetetrahydrofolate is of interest. METHODS:We desc...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2006.085

    authors: Smith DE,Kok RM,Teerlink T,Jakobs C,Smulders YM

    更新日期:2006-01-01 00:00:00