Abstract:
OBJECTIVES:The value of gated single-photon emission computed tomography technetium-99m methoxyisobutylisonitrile (gated SPECT (99m)Tc-MIBI) in children is not yet established probably because gated SPECT (99m)Tc-MIBI has rarely been used in pediatric clinical and research studies. The purpose of this study was to evaluate perfusion abnormalities and left ventricular (LV) function by gated SPECT (99m)Tc-MIBI in children and adolescents with severe congenital heart disease (CHD). METHODS:Seventeen children and adolescents with severe CHD (11 boys and six girls, mean age 11+/-4 years) underwent 2-day rest-stress (11 boys) or 1-day rest (six girls) gated SPECT (99m)Tc-MIBI. Myocardial perfusion was evaluated by a 17-segment model with a 5-point score to derive the summed stress score, the summed rest score (SRS), and the summed difference score based on the 4D-MSPECT software results. The extent of myocardial perfusion abnormalities was also expressed as a percentage of the LV size. The 4D-MSPECT software was used to calculate LV end-diastolic volume, end-systolic volume (ESV), and ejection fraction (EF). RESULTS:Reversible myocardial perfusion defect was found in 7 of 11 children (64%) who underwent rest-stress gated SPECT (99m)Tc-MIBI. The LV segments involved were anterior, anteroseptal, anterolateral, apical and inferior. These seven children showed significantly larger perfusion abnormalities on stress compared with rest study (18+/-5 vs. 7+/-4%, P<0.01) and higher summed stress score compared to SRS (11+/-4 vs. 4+/-2, P<0.01). Children and adolescents with myocardial ischemia had significantly lower poststress EF than rest EF (53+/-12 vs. 59+/-11%, P<0.05) and significantly higher poststress ESV than rest ESV (81+/-24 vs. 61+/-25 ml, P<0.05). In six children evaluated only at rest, perfusion defects involved anterior, anteroseptal and apical, or inferolateral segments, accounting for 31+/-12% of LV and with SRS of 12+/-5. Their global LV parameters were: end-diastolic volume 118+/-23 ml, ESV 56+/-16 ml, EF 51+/-10%. CONCLUSION:Poststress and rest-gated SPECT (99m)Tc-MIBI results indicate that children and adolescents with severe CHD show a range of abnormalities in myocardial perfusion and LV function, which is useful for determining functional importance of morphological malformations. Thus, gated SPECT (99m)Tc-MIBI provides complementary information that may guide clinical decision making in children and adolescents with severe CHD.
journal_name
Nucl Med Communjournal_title
Nuclear medicine communicationsauthors
Sobic-Saranovic DP,Pavlovic SV,Jovanovic IV,Stefanovic ID,Artiko VM,Djukic MM,Obradovic VBdoi
10.1097/MNM.0b013e3283295622subject
Has Abstractpub_date
2010-01-01 00:00:00pages
12-21issue
1eissn
0143-3636issn
1473-5628pii
00006231-201001000-00004journal_volume
31pub_type
杂志文章abstract:INTRODUCTION:Bispecific monoclonal antibodies (bsMAbs) have been developed as a pretargeting tool to reduce background activity, thereby increasing target to background (T : B) ratios. To enhance visualization of small lesions in vivo, we have used the pretargeting approach of bsMAb and negatively charged polymers radi...
journal_title:Nuclear medicine communications
pub_type: 杂志文章
doi:10.1097/MNM.0b013e32834af77b
更新日期:2011-12-01 00:00:00
abstract:AIM:The aim of our study was to assess improvements in spatial resolution and noise control from the application of the Astonish resolution recovery algorithm for single photon emission computed tomography imaging. Secondary aims were to compare acquisitions made with low-energy general purpose collimators with those o...
journal_title:Nuclear medicine communications
pub_type: 杂志文章
doi:10.1097/MNM.0b013e32835ce5b5
更新日期:2013-03-01 00:00:00
abstract:INTRODUCTION:PET/computed tomography (CT) using fluorine-18 fluorodeoxyglucose (F-FDG) has been used in the diagnosis of recurrence and metastases of differentiated thyroid cancer (DTC) in cases of negative whole-body scan (WBS) despite elevated concentrations of stimulated thyroglobulin (Tg). AIM:To assess the utilit...
journal_title:Nuclear medicine communications
pub_type: 杂志文章
doi:10.1097/MNM.0000000000000563
更新日期:2016-09-01 00:00:00
abstract:INTRODUCTION:In pediatric patients with abdominal Burkitt's lymphoma, the involvement of the gastrointestinal tract and abdominal lymph nodes are the main presenting feature of the disease. Chemotherapy is the main treatment modality and could be preceded by surgical excision of the abdominal masses. To achieve cure or...
journal_title:Nuclear medicine communications
pub_type: 杂志文章
doi:10.1097/MNM.0b013e328334fc14
更新日期:2010-03-01 00:00:00
abstract::Alzheimer's disease is associated with a loss in presynaptic cholinergic function. It has been suggested that cholinergic inhibitors such as donepezil hydrochloride (Donepezil) could restore this function and improve some of the symptoms of Alzheimer's disease. Previous work has shown that Donepezil improves cognitive...
journal_title:Nuclear medicine communications
pub_type: 临床试验,杂志文章
doi:10.1097/00006231-200001000-00007
更新日期:2000-01-01 00:00:00
abstract::Fever of unknown origin is defined as a temperature above 39.0 degrees C together with a white blood cell count > or = 15,000 mm-3, the duration of fever exceeding 2 weeks and a correct diagnosis not being obtained in the first week of hospitalization. In neonates and infants with fever of unknown origin, the localiza...
journal_title:Nuclear medicine communications
pub_type: 杂志文章
doi:10.1097/00006231-199811000-00003
更新日期:1998-11-01 00:00:00
abstract:OBJECTIVE:The aim of the study was to evaluate the accuracy of the sequential multiphase and dual-tracer (SMADT) technique utilizing technetium-99m pertechnetate (99mTcO4) and dynamic technetium-99m-2-methoxyisobutylisonitrile (99mTc-MIBI) with single-photon emission computed tomography/computed tomography (SPECT/CT) f...
journal_title:Nuclear medicine communications
pub_type: 杂志文章
doi:10.1097/MNM.0000000000000215
更新日期:2015-01-01 00:00:00
abstract::The radiation dose to the pulp of both index fingers has been measured in a radiopharmacy supplying 11 000 patient doses a year, in a hospital dispensary (4500 doses a year) and in its injection area. Tungsten syringe shields were used for one week and not used during the other week. In the radiopharmacy and the dispe...
journal_title:Nuclear medicine communications
pub_type: 杂志文章
doi:10.1097/00006231-198508000-00004
更新日期:1985-08-01 00:00:00
abstract:PURPOSE:To investigate the accuracy of different interpretative approaches and to evaluate the management implications of fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) in cutaneous malignant melanoma. METHODS:We retrospectively identified 60 consecutive patients who underwent 76 PET/...
journal_title:Nuclear medicine communications
pub_type: 临床试验,杂志文章
doi:10.1097/MNM.0b013e3280708ecf
更新日期:2007-04-01 00:00:00
abstract:OBJECTIVES:Computed tomography (CT) automatic exposure control (AEC) systems are now used in all modern PET-CT scanners. A collaborative study was undertaken to compare AEC techniques of the three major PET-CT manufacturers for fluorine-18 fluorodeoxyglucose half-body oncology imaging. MATERIALS AND METHODS:An audit o...
journal_title:Nuclear medicine communications
pub_type: 杂志文章
doi:10.1097/MNM.0000000000000064
更新日期:2014-04-01 00:00:00
abstract:PURPOSES:This study aims to explore the prognostic value of left ventricular mechanical dyssynchrony (LVMD) in hypertrophic cardiomyopathy (HCM) patients with low risk of sudden cardiac death (SCD). METHODS:This retrospective study was performed in 50 patients with HCM who underwent Tc-99m sestamibi GSPECT-MPI. All pa...
journal_title:Nuclear medicine communications
pub_type: 杂志文章
doi:10.1097/MNM.0000000000001322
更新日期:2021-02-01 00:00:00
abstract::Salivary gland scintigraphy (SGS) is used to depict salivary gland dysfunction after radiotherapy (RT). The aim of this study was to investigate the utility of SGS combined with single photon emission computed tomography (SPECT). Twenty-one patients with a carcinoma of head and neck underwent SGS before and 1 month af...
journal_title:Nuclear medicine communications
pub_type: 临床试验,杂志文章
doi:10.1097/00006231-200102000-00015
更新日期:2001-02-01 00:00:00
abstract:OBJECTIVE:Assessing the relative function of each of the three kidneys using nuclear scintigraphy with standard planar imaging in patients having undergone kidney transplant is problematic because of the different photon-attenuation factors associated with native versus transplanted kidneys. To address this, we applied...
journal_title:Nuclear medicine communications
pub_type: 杂志文章
doi:10.1097/MNM.0b013e328347e958
更新日期:2011-08-01 00:00:00
abstract:INTRODUCTION:Respiratory complications are common after arthroplasty, with pulmonary thromboembolic disease (PTE) and fat emboli being the most serious. A scintigraphic study was designed to assess the occurrence of both diseases. A prospective tomographic study of perfusion was performed within 24 h of arthroplasty. D...
journal_title:Nuclear medicine communications
pub_type: 杂志文章
doi:10.1097/00006231-200111000-00011
更新日期:2001-11-01 00:00:00
abstract:AIM:To perform a detailed analysis of the performance of mobile intraoperative imaging systems and gamma probes in a phantom set-up, and compare this with a conventional gamma camera. METHODS:Two separate experiments were performed. In the first, a modified Jaszczak phantom equipped with five (99m)Tc-filled hot sphere...
journal_title:Nuclear medicine communications
pub_type: 杂志文章
doi:10.1097/MNM.0b013e3283508577
更新日期:2012-05-01 00:00:00
abstract::High-grade astrocytoma represents the most common primary malignant brain tumour in the adult, and is associated with high morbidity and mortality rates. The aim of this study was to investigate the prognostic value of 99Tcm-hexamethylpropyleneamine oxime (HMPAO) brain single photon emission computed tomography (SPECT...
journal_title:Nuclear medicine communications
pub_type: 杂志文章
doi:10.1097/00006231-199312000-00002
更新日期:1993-12-01 00:00:00
abstract:OBJECTIVE:The aim of this study was to validate the efficacy of computed tomography (CT) iterative reconstruction (CT-IR) for low-dose CT attenuation correction in terms of the estimation of attenuation coefficient and quality of PET images. MATERIALS AND METHODS:We used normal and obesity-simulating body phantoms. PE...
journal_title:Nuclear medicine communications
pub_type: 杂志文章
doi:10.1097/MNM.0000000000000326
更新日期:2015-08-01 00:00:00
abstract::This survey investigated the nature of imaging staff and the distribution and structure of nuclear medicine departments in the UK. Total numbers of cameras and average per department were lower than in 1989/90 but higher than the 1992/93 survey. Total whole time equivalents, average per department and average per came...
journal_title:Nuclear medicine communications
pub_type: 杂志文章
doi:10.1097/00006231-200105000-00016
更新日期:2001-05-01 00:00:00
abstract::Dynamic penile scintigraphy was performed using 99Tcm-labelled autologous erythrocytes in five normally potent volunteers and 22 patients with erectile dysfunction including 11 patients with psychogenic and 11 patients with vasculogenic impotence (four arteriogenic, three venogenic, three arteriogenic and venogenic, o...
journal_title:Nuclear medicine communications
pub_type: 杂志文章
doi:10.1097/00006231-199311000-00007
更新日期:1993-11-01 00:00:00
abstract:BACKGROUND:To compare the accuracy of various equations for estimating glomerular filtration rate. METHODS:Chronic kidney disease was classified by Tc-DTPA scintigraphy (reference glomerular filtration rate), estimating glomerular filtration rate was estimated using various formulas. The similarity to reference glomer...
journal_title:Nuclear medicine communications
pub_type: 杂志文章
doi:10.1097/MNM.0000000000001141
更新日期:2020-03-01 00:00:00
abstract::Scintimammography is a recently verified technique that will expand the use of nuclear medicine to a new group of patients in whom scintigraphic imaging has not been widely used. If performed correctly, and in certain groups of patients, it delivers a sensitivity as high as X-ray mammography or magnetic resonance imag...
journal_title:Nuclear medicine communications
pub_type: 杂志文章,评审
doi:10.1097/00006231-199708000-00003
更新日期:1997-08-01 00:00:00
abstract:BACKGROUND:123I has been promoted for diagnostic imaging as a means of avoiding 'stunning'. It has also been suggested that the more favourable physical characteristics and consequent enhanced imaging resolution provided by 123I offers a more accurate diagnostic assessment of the extent of disease prior to therapy. Thi...
journal_title:Nuclear medicine communications
pub_type: 临床试验,杂志文章
doi:10.1097/00006231-200402000-00006
更新日期:2004-02-01 00:00:00
abstract::A technique is described for the quantification of the three-dimensional distribution of 131I radiopharmaceuticals using single photon emission computed tomography (SPECT). A theoretical discussion of the problems of scatter and septal penetration in 131I SPECT is presented. The correction of these effects using the g...
journal_title:Nuclear medicine communications
pub_type: 杂志文章
doi:10.1097/00006231-199306000-00014
更新日期:1993-06-01 00:00:00
abstract::Pulmonary involvement in Behçet's disease (BD) is reported to indicate poor prognosis and high mortality. Our aim was to evaluate the pulmonary vascular status in BD. As 123I-meta-iodobenzylguanidine (123I-MIBG) shares the same uptake, storage and release mechanisms as norepinephrine, associated with the functional st...
journal_title:Nuclear medicine communications
pub_type: 杂志文章
doi:10.1097/00006231-200110000-00005
更新日期:2001-10-01 00:00:00
abstract::Radioiodine therapy using oral administration of Iodine-131 (I) is a widespread employed strategy for the treatment of hyperthyroidism and thyroid cancer. Such a therapy requires well-trained staff, equipment and procedures regarding radiation safety. The aims of this work are to report an incidental experience of rad...
journal_title:Nuclear medicine communications
pub_type: 杂志文章
doi:10.1097/MNM.0000000000001276
更新日期:2020-11-01 00:00:00
abstract::Mobile PET/CT or mobile stand alone PET, is becoming more widely available throughout the developed world, allowing many small and medium-sized hospitals that do not have the scale or financial resources to purchase the static diagnostic equipment, to benefit from this imaging technology. Before embarking on such a se...
journal_title:Nuclear medicine communications
pub_type: 杂志文章,评审
doi:10.1097/MNM.0b013e3282f25919
更新日期:2008-02-01 00:00:00
abstract:OBJECTIVE:To investigate the relationship between lymph node (LN) size and localization and prostate-specific membrane antigen (PSMA) uptake in patients with prostate cancer. PATIENTS AND METHODS:Between February 2015 and February 2017, a total of 178 patients diagnosed with prostate adenocarcinoma by gallium-68 PSMA ...
journal_title:Nuclear medicine communications
pub_type: 杂志文章
doi:10.1097/MNM.0000000000001032
更新日期:2019-08-01 00:00:00
abstract::The aim of the study was to measure the actual dose at 1 m from the patients per unit activity with the aim of providing a more accurate prediction of the dose levels around radioiodine patients in the hospital, as well as to compare our results with the literature. In this work the demonstration of a patient body tis...
journal_title:Nuclear medicine communications
pub_type: 杂志文章
doi:10.1097/MNM.0000000000000223
更新日期:2015-02-01 00:00:00
abstract:OBJECTIVE:The aim of this study was to assess the relationship between fluorine-18 fluorodeoxyglucose (F-FDG) uptake and molecular biological markers in esophageal squamous cell carcinoma (ESCC) patients. METHODS:Our patient population included 51 patients who underwent F-FDG PET/computed tomography before surgery. Ex...
journal_title:Nuclear medicine communications
pub_type: 杂志文章
doi:10.1097/MNM.0000000000000550
更新日期:2016-10-01 00:00:00
abstract::The combination of a diagnosis of malignancy and hospitalization, isolation and radioactivity of a radionuclide therapy may have an important effect on the psychological equilibrium of patients and may hamper compliance and acceptability. We performed a psychiatric evaluation in order to study psycho-pathological mani...
journal_title:Nuclear medicine communications
pub_type: 临床试验,杂志文章
doi:10.1097/01.mnm.0000084586.29433.83
更新日期:2003-08-01 00:00:00