Effects of extracellular Na+ and Ca2+ ions and Ca2+ channel modulators on the cell-associated activity of 99mTc-MIBI and 99mTc-tetrofosmin in tumour cells.

Abstract:

:Our aim was to determine whether the Ca2+ ion or cell membrane Ca2+ and Na+/Ca2+ ion transport systems are involved in maintaining the cell-associated activity of technetium-99m-hexakis-methoxy-isobutyl-isonitrile (99mTc-MIBI) and technetium-99m-ethylene-bis[bis(2-ethoxyethyl)phosphin] (99mTc-tetrofosmin) in tumour cell lines. The cell-associated activities of 99mTc-MIBI and 99mTc-tetrofosmin were assessed in various buffers, with or without Na+ and/or with different concentrations of Ca2+, in Lewi's murine lung cell carcinoma and human glioma cell lines. Different Ca2+ channel modulators, such as verapamil, flunarizine and 3,4-dichlorobenzamil (DCB), were used to assess the effect of Ca2+ channels on the cell-associated activity of 99mTc-MIBI and 99mTc-tetrofosmin. Despite significant differences between cell lines, the cell-associated activity of 99mTc-MIBI was higher in buffers without extracellular Ca2+ and Na+. The cell-associated activity of 99mTc-MIBI was significantly lower in all buffers containing high concentrations of Ca2+ in both cell lines. The cell-associated activity of Tc-tetrofosmin was also significantly higher in buffers without Ca2+, and was significantly decreased in buffers with high concentrations of Ca2+. All modulators significantly increased the cell-associated activity of 99mTc-MIBI in both cell lines in all buffers. All modulators increased the cell-associated activity of 99mTc-tetrofosmin, particularly in buffers containing Ca2+. The cell-associated activities of both 99mTc-MIBI and 99mTc-tetrofosmin may be dependent on verapamil-, flunarizine- and DCB-sensitive Ca2+ channels.

journal_name

Nucl Med Commun

authors

Arbab AS,Ueki J,Koizumi K,Araki T

doi

10.1097/00006231-200302000-00008

keywords:

subject

Has Abstract

pub_date

2003-02-01 00:00:00

pages

155-66

issue

2

eissn

0143-3636

issn

1473-5628

journal_volume

24

pub_type

杂志文章
  • Improving radiopharmaceutical supply chain safety by implementing bar code technology.

    abstract::The aim of this study was to describe and evaluate an approach for improving radiopharmaceutical supply chain safety by implementing bar code technology. We first evaluated the current situation of our radiopharmaceutical supply chain and, by means of the ALARM protocol, analysed two dispensing errors that occurred in...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000177

    authors: Matanza D,Hallouard F,Rioufol C,Fessi H,Fraysse M

    更新日期:2014-11-01 00:00:00

  • Quality of care: identification and quantification of the process of care among children undergoing nuclear medicine studies.

    abstract::The aim of this study was to define indices which could be used to assess the quality of care of children undergoing an examination requiring intravenous (i.v.) access in an integrated department of radiology and to see if these indices could be quantified. A prospective study of all patients requiring an i.v. injecti...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:

    authors: Sherazi Z,Gordon I

    更新日期:1996-05-01 00:00:00

  • Differential renal function estimation by dynamic renal scintigraphy: influence of background definition and radiopharmaceutical.

    abstract:OBJECTIVES:Differential renal function (DRF) calculation with 99mTc-diethylenetriamine-pentaacetic acid (DTPA) or mercaptoacetyltriglycine (MAG3) is gaining clinical importance in the evaluation of patients with ureteropelvic junction obstruction with hydronephrosis (HN). Although many decisions regarding surgery are b...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e32830978af

    authors: Caglar M,Gedik GK,Karabulut E

    更新日期:2008-11-01 00:00:00

  • The effects of informational intervention on state anxiety and satisfaction in patients undergoing bone scan.

    abstract::The aim of the study was to identify the most beneficial mode, in terms of anxiety reduction, of giving patients information prior to them undergoing a bone scan. (Research has identified the scan procedure as having a demonstrative effect on anxiety.) Additionally, satisfaction with the adequacy of the information wa...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-199411000-00011

    authors: Leckie J

    更新日期:1994-11-01 00:00:00

  • Comparison between visual and numerical metrics for the evaluation of patients with Takayasu arteritis with 18F-FDG-PET.

    abstract:INTRODUCTION:The choice of metrics for defining active Takayasu arteritis (TAK) using fluorine-18-fluorodeoxyglucose (F-FDG)-PET remains controversial. OBJECTIVE:The aim of this study was to compare in the same patients the diagnostic performance for the detection of active TAK of different metrics applied for the qua...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000867

    authors: Emsen B,Benali K,Mahida B,Larivière D,Le Guludec D,Papo T,Sacre K,Hyafil F

    更新日期:2018-08-01 00:00:00

  • 111In-labelled platelets for assessment of thrombogenicity of new haemodialysis vascular access.

    abstract::Using platelet scintigraphy to evaluate early thrombogenicity, we examined 39 new vascular accesses 4 weeks and 3 months after surgery. We found a significant association between platelet deposition and Doppler flow (P < 0.01) and blood pressure (P < 0.01). Compared with arteriovenous fistulae, prosthetic grafts showe...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199905000-00008

    authors: Neumann I,Meisl FT,Kopriva G,Manker W,Sinzinger H

    更新日期:1999-05-01 00:00:00

  • Measurement of the extravascular concentration of renal agents following intravenous bolus injection.

    abstract::The extravascular concentration (Ce) of some renal agents, in relation to the simultaneous plasma concentration (Ci), was calculated as a function of time after intravenous injection. Four agents were studied: 51Cr-ethylenediamine tetraacetate (EDTA) (n = 11), 125I-hippuran (n = 11), 99Tcm-dimercaptosuccinic acid (DMS...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199402000-00002

    authors: Peters AM,Brown H,Cosgriff P

    更新日期:1994-02-01 00:00:00

  • A simple method for estimating the skeletal uptake of diphosphonates.

    abstract::It is possible to obtain an estimate of the bone uptake of diphosphonates after 3 h (BU) on the basis of the difference between the dose administered and the sum of the component eliminated in the urine plus the component present in the extra-osseous volume of distribution. The results of this simple method have been ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199509000-00008

    authors: Galli G,Bagnato A,Galli M

    更新日期:1995-09-01 00:00:00

  • 18F-Fluorodeoxyglucose PET/CT and dynamic contrast-enhanced MRI as imaging biomarkers in malignant pleural mesothelioma.

    abstract:PURPOSE:The purpose of this study was to compare the use of fluorine-18-fluorodeoxyglucose (F-FDG) PET with computed tomography (CT) and dynamic contrast-enhanced (DCE) MRI to predict prognosis and monitor treatment in malignant pleural mesothelioma. PATIENTS AND METHODS:F-FDG PET/CT and DCE-MRI studies carried out as...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/MNM.0000000000000789

    authors: Hall DO,Hooper CE,Searle J,Darby M,White P,Harvey JE,Braybrooke JP,Maskell NA,Masani V,Lyburn ID

    更新日期:2018-02-01 00:00:00

  • The effectiveness of low-dose versus high-dose 99mTc MIBI protocols for radioguided surgery in patients with primary hyperparathyroidism.

    abstract:OBJECTIVE:The aim of this study was to compare the efficacy of low-dose and high-dose (99m)Tc methoxy isobutyl isonitrile (MIBI) protocols in intraoperative localization of parathyroid adenomas by means of a gamma probe in patients with primary hyperparathyroidism (PHPT). PATIENTS AND METHODS:The study included 62 pat...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000056

    authors: Gencoglu EA,Aras M,Moray G,Aktas A

    更新日期:2014-04-01 00:00:00

  • Reductions in finger doses for radiopharmaceutical dispensing afforded by a syringe shield and an automatic dose dispenser.

    abstract::A gamma extremity monitoring system (GEMS) has been used to measure finger doses during radio-nuclide dispensing procedures. GEMS uses a small semi-conductor probe that can be attached to a finger from which a continuous read-out can be obtained that is related to dose rate. The pattern of dose accumulation can be ana...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199902000-00013

    authors: Montgomery A,Anstee DE,Martin CJ,Hilditch TE

    更新日期:1999-02-01 00:00:00

  • Evaluation of 90Y phosphate particles as a possible radiation synoviorthesis agent.

    abstract:BACKGROUND:90Y is one of the radioisotopes used extensively for therapy due to its favourable nuclear characteristics. Particles and colloids incorporating 90Y are being used for radiation synovectomy, especially in European countries. METHODS:In our present work, 90Y phosphate particles were prepared and evaluated fo...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200505000-00011

    authors: Pandey U,Bapat KN,Samuel G,Sarma HD,Chaudhari PR,Dhami PS,Kannan R,Venkatesh M

    更新日期:2005-05-01 00:00:00

  • Different methods for the detection of small changes in uptake between single-photon emission computed tomography (SPECT) examinations: 99mTc-sestamibi in chemotherapy for breast tumours.

    abstract:AIM:This study was undertaken to evaluate different methods for the detection of small changes in uptake between single-photon emission computed tomography (SPECT) examinations in the same individual. No standard exists for making digital evaluations at single-photon examinations. For this purpose, we employed a patien...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/01.mnm.0000202866.97787.45

    authors: Jacobsson H,Wilczek B,Bergh J,von Schoultz E,Eriksson E,Larsson SA

    更新日期:2006-04-01 00:00:00

  • The utility of SPECT in determining the relationship between radiation dose and salivary gland dysfunction after radiotherapy.

    abstract::Salivary gland scintigraphy (SGS) is used to depict salivary gland dysfunction after radiotherapy (RT). The aim of this study was to investigate the utility of SGS combined with single photon emission computed tomography (SPECT). Twenty-one patients with a carcinoma of head and neck underwent SGS before and 1 month af...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-200102000-00015

    authors: van Acker F,Flamen P,Lambin P,Maes A,Kutcher GJ,Weltens C,Hermans R,Baetens J,Dupont P,Rijnders A,Maes A,van den Bogaert W,Mortelmans L

    更新日期:2001-02-01 00:00:00

  • Criteria for the use of monoclonal antibodies, legislation and ethical considerations.

    abstract::The criteria governing the in vivo use of monoclonal antibodies in humans are based upon a number of legal requirements with respect to radiation hygiene, pharmaceutical legislation, radiopharmaceutical legislation and regulations with respect to products arising from biotechnology. This in itself has led to a complic...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199308000-00005

    authors: Cox PH

    更新日期:1993-08-01 00:00:00

  • Non-invasive assessment of absolute values of hepatic haemodynamics using radiocolloid scintigraphy.

    abstract::A non-invasive technique for the assessment of hepatic haemodynamics using radiocolloid imaging with a computer, in which absolute values of hepatic, mesenteric and splenic arterial effective blood flows were assessed, is described. The technique was carried out on ten volunteers, before and after a standard meal. Aft...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198708000-00002

    authors: Walmsley BH,Fleming JS,Ackery DM,Karran SJ

    更新日期:1987-08-01 00:00:00

  • Significant correlation between cerebral hypoperfusion and neuropsychological assessment scores of patients with mild cognitive impairment.

    abstract:PURPOSE:The regions of significant correlation between cerebral hypoperfusion and neuropsychological assessment scores were evaluated using (99m)Tc-HMPAO SPECT in patients with mild cognitive impairment (MCI) on the basis of its three subtypes, namely, single-domain amnestic MCI (aMCI-s), multiple-domain amnestic MCI (...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e32835587f8

    authors: Yoon HJ,Park KW,Jeong YJ,Kang DY

    更新日期:2012-08-01 00:00:00

  • Diastolic dysfunction can precede systolic dysfunction on MUGA in cancer patients receiving trastuzumab-based therapy.

    abstract:BACKGROUND:Trastuzumab (T) and anthracycline (A)-based chemotherapy is considered the standard of care in human epidermal growth factor receptor-2+ overexpressing breast cancer, but requires monitoring for known cardiotoxicity using left ventricular (LV) ejection fraction (EF) every 3-4 months during treatment. It is n...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000941

    authors: Klein R,Nadouri D,Osler E,Johnson C,Dent S,Dwivedi G

    更新日期:2019-01-01 00:00:00

  • Propagation of measurement errors in glomerular filtration rate determination: a comparison of slope-intercept, single-sample and slope-only methods.

    abstract:BACKGROUND:Measurement errors occurring during glomerular filtration rate (GFR) studies propagate to an error in the calculated GFR. Previous work has modelled measurement errors for slope-intercept (SI-GFR), single-sample (SS-GFR) and slope-only (SO-GFR) methods. In this study, we have extended these models. The prima...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000977

    authors: Holness JL,Fleming JS,Chirehwa MT,Warwick JM

    更新日期:2019-04-01 00:00:00

  • Relationship between positive thyroglobulin doubling time and 18F-FDG PET/CT-positive, 131I-negative lesions.

    abstract:AIM:In patients with differentiated thyroid carcinoma (DTC), metastases can either show iodine-131 (I) uptake on whole-body scintigraphy or F-2-fluoro-2-deoxy-D-glucose (F-FDG) uptake on combined PET and X-ray computed tomography (PET/CT), or a mix of both. The present study investigates the relationship between uptake...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000025

    authors: Kelders A,Kennes LN,Krohn T,Behrendt FF,Mottaghy FM,Verburg FA

    更新日期:2014-02-01 00:00:00

  • Comparison of 99Tcm-sestamibi and 201Tl-chloride to estimate right ventricular overload in children.

    abstract::To evaluate right ventricular overload in paediatric patients with congenital cardiac disease (n = 25), the uptakes of 201Tl and 99Tcm-sestamibi (99Tcm-MIBI) were compared. 99Tcm-MIBI showed a clearer myocardial border and better contrast between the myocardium and ventricular cavity. Although hepatic activity may inf...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199511000-00010

    authors: Nakajima K,Taki J,Taniguchi M,Tonami N,Hisida K

    更新日期:1995-11-01 00:00:00

  • Role of SUV(max) obtained by 18F-FDG PET/CT in patients with a solitary pancreatic lesion: predicting malignant potential and proliferation.

    abstract:OBJECTIVES:Maximum standardized uptake value (SUV(max)) is a marker of tumor glucose metabolism detected by [(18)F]-fluorodeoxyglucose ((18)F-FDG) PET/computed tomography (PET/CT) and reflects tumor aggressiveness. The aim of the study was to evaluate the value of SUV(max) in differentiating benign from malignant solit...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e328360668a

    authors: Hu SL,Yang ZY,Zhou ZR,Yu XJ,Ping B,Zhang YJ

    更新日期:2013-06-01 00:00:00

  • Left ventricular ejection fraction determined with the nuclear stethoscope, gamma camera and contrast ventriculography.

    abstract::Left ventricular ejection fractions (EF) were measured with a nuclear stethoscope (NSt, beat-to-beat and ECG gated summation method) and contrast ventriculography (VG) immediately following one another (IFOA) (r X 0.96 and 0.95, respectively, n = 13). NSt and ECG gated gamma camera (MUGA) recordings IFOA were compared...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198605000-00003

    authors: Lund O,Rasmussen K,Jensen FT,Hansen HH

    更新日期:1986-05-01 00:00:00

  • 18F-FDG PET/CT as a semiquantitative imaging marker in HPV-p16-positive oropharyngeal squamous cell cancers.

    abstract:PURPOSE:There is evidence that the status of human papilloma virus subtype 16 (HPV-p16) alters the prognosis of patients with oropharyngeal squamous cell cancer (OSCC). We sought to establish whether there is a relationship between HPV-p16 status and 18F-FDG uptake in the prognosis of OSCC. MATERIALS AND METHODS:Patie...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000208

    authors: Huang YT,Ravi Kumar AS,Bhuta S

    更新日期:2015-01-01 00:00:00

  • Pilot study comparing dominant intraprostatic lesion volume using Ga-68 prostate-specific membrane antigen PET-computed tomography and multiparametric MRI.

    abstract:PURPOSE:The standard imaging used for delineation of dominant intraprostatic lesion (DIL) is multiparametric MRI (mpMRI). The use of biologic imaging such as Ga-68 prostate-specific membrane antigen (PSMA) PET-computed tomography (PET-CT) for this purpose is being explored in view of increased sensitivity of this modal...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000001283

    authors: Sasidharan A,Murthy V,Natarajan A,Agarwal A,Ranagrajan V,Gudi S,Singh S,Popat P

    更新日期:2020-12-01 00:00:00

  • Effect of different segmentation algorithms on metabolic tumor volume measured on 18F-FDG PET/CT of cervical primary squamous cell carcinoma.

    abstract:BACKGROUND AND PURPOSE:It is known that fluorine-18 fluorodeoxyglucose PET/computed tomography (CT) segmentation algorithms have an impact on the metabolic tumor volume (MTV). This leads to some uncertainties in PET/CT guidance of tumor radiotherapy. The aim of this study was to investigate the effect of segmentation a...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000641

    authors: Xu W,Yu S,Ma Y,Liu C,Xin J

    更新日期:2017-03-01 00:00:00

  • Radiation doses from nuclear medicine patients to an imaging technologist: relation to ICRP recommendations for pregnant workers.

    abstract::The ICRP has now recommended that the dose limit to the surface of the mother's abdomen during the declared term of pregnancy is reduced to 2 mSv. Direct measurements of the radiation dose to technologists carrying out a variety of imaging studies were made. The average dose ranged from 0.3 micro Sv for a liver scan t...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199211000-00004

    authors: Clarke EA,Thomson WH,Notghi A,Harding LK

    更新日期:1992-11-01 00:00:00

  • Improvement of the amplitude image through statistical filtering.

    abstract::In order to perform automatically the thresholding of the amplitude image obtained by phase analysis, a filter based on the probability density of the amplitude is proposed. It generates the image of the significant amplitude by setting to zero the amplitude if its square is lower than 4a0 log(1/alpha)/N where a0 is t...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198710000-00005

    authors: Liehn JC,Valeyre J

    更新日期:1987-10-01 00:00:00

  • A novel iterative method for lesion delineation and volumetric quantification with FDG PET.

    abstract:OBJECTIVES:The determination of lesion boundaries on FDG PET is difficult due to the point-spread blurring and unknown uptake of activity within a lesion. Standard threshold-based methods for volumetric quantification on PET usually neglect any size dependence and are biased by dependence on the signal-to-background ra...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/MNM.0b013e328155d154

    authors: van Dalen JA,Hoffmann AL,Dicken V,Vogel WV,Wiering B,Ruers TJ,Karssemeijer N,Oyen WJ

    更新日期:2007-06-01 00:00:00

  • Use of insulin to improve [18 F]fluorodeoxyglucose labelling and retention for in vivo positron emission tomography imaging of monocyte trafficking.

    abstract::While 18F-FDG labelling of monocytes would allow in vivo trafficking with positron emission tomography (PET), present methods suffer from poor retention of radioactivity. We investigated the feasibility of utilizing insulin for improved [18F]fluorodeoxyglucose (18F-FDG) labelling. Separated human monocytes and lymphoc...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200206000-00007

    authors: Paik JY,Lee KH,Byun SS,Choe YS,Kim BT

    更新日期:2002-06-01 00:00:00