Software-annotated, digitally photographed, and printed MR images: suitability for publication.

Abstract:

RATIONALE AND OBJECTIVES:The authors performed this study to evaluate whether digitally photographed, computer-annotated MR images produced by clinical radiologists and printed with an inexpensive photo printer are suitable for publication. MATERIALS AND METHODS:Laser prints of 20 magnetic resonance images of the brain were photographed with a 3-megapixel digital camera and annotated with arrows, arrowheads, and asterisks by using graphics software that incorporates vector support. Then, 5 x 7-inch glossy prints with white borders were made by using an inexpensive photo printer. These prints were compared with those produced of the same 20 images by members of the medical center's graphics department with professional scanning and printing equipment and annotated with conventional rub-on symbols. Eight radiologists evaluated image and annotation quality and overall suitability for publication. RESULTS:In all three categories, the images produced by radiologists outscored those produced by the graphics department. CONCLUSION:Digitally photographed, software-annotated MR images printed with an inexpensive photo printer are suitable for publication.

journal_name

Acad Radiol

journal_title

Academic radiology

authors

Caruso RD,Postel GC,McDonald CS,Aronson BA,Christensen JD

doi

10.1016/s1076-6332(03)80378-1

keywords:

subject

Has Abstract

pub_date

2002-03-01 00:00:00

pages

346-51

issue

3

eissn

1076-6332

issn

1878-4046

journal_volume

9

pub_type

杂志文章
  • NCI image archive management workshop: a preliminary report.

    abstract::The National Cancer Institute organized a workshop entitled "Image Archive Management" that was presented on August 28 and 29, 2000, at the Natcher Conference Center on the National Institutes of Health (NIH) campus. The purpose of this workshop was to solicit expert input for the planned development of an archival sy...

    journal_title:Academic radiology

    pub_type:

    doi:10.1016/S1076-6332(03)80699-2

    authors: Staab E,Clarke LP,Baker H,Sullivan D

    更新日期:2001-07-01 00:00:00

  • High-resolution computed tomography of airway changes after induced bronchoconstriction and bronchodilation in asthmatic volunteers.

    abstract:RATIONALE AND OBJECTIVES:We examined whether high-resolution computed tomography (HRCT) would detect and quantify induced airway changes in asthmatic volunteers. METHODS:We performed pulmonary function tests and HRCT on eight asthmatic adults and two nonasthmatic control adults under three conditions: baseline, after ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(05)80671-3

    authors: Kee ST,Fahy JV,Chen DR,Gamsu G

    更新日期:1996-05-01 00:00:00

  • Computer-assisted mammography feedback program (CAMFP) an electronic tool for continuing medical education.

    abstract:RATIONALE AND OBJECTIVES:Our goal was to develop and evaluate software to support a computer assisted mammography feedback program (CAMFP) to be used for continuing medical education (CME). MATERIALS AND METHODS:Thirty-five radiologists from our region signed consent to participate in an institutional review board-app...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2007.05.018

    authors: Urban N,Longton GM,Crowe AD,Drucker MJ,Lehman CD,Peacock S,Lowe KA,Zeliadt SB,Gaul MA

    更新日期:2007-09-01 00:00:00

  • Abbreviated screening protocol for breast MRI: a feasibility study.

    abstract:RATIONALE AND OBJECTIVES:To compare the performance of two shortened breast magnetic resonance imaging (MRI) protocols to a standard MRI protocol for breast cancer screening. MATERIALS AND METHODS:In this Health Insurance Portability and Accountability Act compliant, institutional review board-approved pilot study, th...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2015.06.004

    authors: Grimm LJ,Soo MS,Yoon S,Kim C,Ghate SV,Johnson KS

    更新日期:2015-09-01 00:00:00

  • Academic Remediation: Why Early Identification and Intervention Matters.

    abstract::At our institution, we have developed a remediation team of strong, focused experts who help us with struggling learners in making the diagnosis and then coaching on their milestone deficits. It is key for all program directors to recognize struggling residents because early recognition and intervention gives the resi...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2016.12.022

    authors: Rumack CM,Guerrasio J,Christensen A,Aagaard EM

    更新日期:2017-06-01 00:00:00

  • Using health services research to meet ACGME resident research requirements.

    abstract::Health services research is a field of research that crosses many disciplines. It represents a novel way to address the Accreditation Council for Graduate Medical Education requirements for scholarly activity of residents and faculty in academic radiology departments. In addition to meeting training requirements, it o...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2013.05.007

    authors: Heilbrun ME,Rawson JV,Shah M

    更新日期:2013-09-01 00:00:00

  • How good is the ACR accreditation phantom for assessing image quality in digital mammography?

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to evaluate the American College of Radiology (ACR) accreditation phantom for assessing image quality in digital mammography. MATERIALS AND METHODS:Digital images were obtained of an ACR accreditation phantom at varying mAs (constant kVp) and varying kVp (constant...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(03)80345-8

    authors: Huda W,Sajewicz AM,Ogden KM,Scalzetti EM,Dance DR

    更新日期:2002-07-01 00:00:00

  • New assistive devices for MR-guided microwave thermocoagulation of liver tumors.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to develop and test new assistive devices to aid in the performance of safe, easy, and accurate microwave thermocoagulation therapy guided by magnetic resonance (MR) imaging. MATERIALS AND METHODS:An open-configuration MR imager with an optical tracking system for...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(03)80043-0

    authors: Morikawa S,Inubushi T,Kurumi Y,Naka S,Sato K,Tani T,Haque HA,Tokuda J,Hata N

    更新日期:2003-02-01 00:00:00

  • Augmented Radiologist Workflow Improves Report Value and Saves Time: A Potential Model for Implementation of Artificial Intelligence.

    abstract:RATIONALE AND OBJECTIVES:Our primary aim was to improve radiology reports by increasing concordance of target lesion measurements with oncology records using radiology preprocessors (RP). Faster notification of incidental actionable findings to referring clinicians and clinical radiologist exam interpretation time savi...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2019.09.014

    authors: Do HM,Spear LG,Nikpanah M,Mirmomen SM,Machado LB,Toscano AP,Turkbey B,Bagheri MH,Gulley JL,Folio LR

    更新日期:2020-01-01 00:00:00

  • Preoperative Prediction of Ki-67 Status in Breast Cancer with Multiparametric MRI Using Transfer Learning.

    abstract:RATIONALE AND OBJECTIVES:Ki-67 is one of the most important biomarkers of breast cancer traditionally measured invasively via immunohistochemistry. In this study, deep learning based radiomics models were established for preoperative prediction of Ki-67 status using multiparametric magnetic resonance imaging (mp-MRI). ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2020.02.006

    authors: Liu W,Cheng Y,Liu Z,Liu C,Cattell R,Xie X,Wang Y,Yang X,Ye W,Liang C,Li J,Gao Y,Huang C,Liang C

    更新日期:2021-02-01 00:00:00

  • Interobserver and intraobserver variability in the assessment of pulmonary nodule size on CT using film and computer display methods.

    abstract:RATIONALE AND OBJECTIVES:A critical element in determining biologic behavior of pulmonary nodules is volume and temporal volume change. We evaluate variability in nodule volume among readers and measuring methods. MATERIALS AND METHODS:55 small (<2 cm) lung nodules were measured in long- and short-axis dimensions inde...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2005.04.009

    authors: Bogot NR,Kazerooni EA,Kelly AM,Quint LE,Desjardins B,Nan B

    更新日期:2005-08-01 00:00:00

  • Recognition of Neonatal Lymphatic Flow Disorder: Fetal MR Findings and Postnatal MR Lymphangiogram Correlation.

    abstract:RATIONALE AND OBJECTIVES:This study aimed to describe prenatal and postnatal imaging features and outcomes of neonates with neonatal lymphatic disorders (NLDs). MATERIALS AND METHODS:An institutional review board-approved search of the radiology database for patients with NLD identified five patients. Inclusion criter...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2018.02.020

    authors: Biko DM,Johnstone JA,Dori Y,Victoria T,Oliver ER,Itkin M

    更新日期:2018-11-01 00:00:00

  • Seventy-Peak Kilovoltage High-Pitch Thoracic Aortic CT Angiography without ECG Gating: Evaluation of Image Quality and Radiation Dose.

    abstract:RATIONALE AND OBJECTIVES:To assess the feasibility of 70-kVp high-pitch non-ECG-gated thoracic aortic computed tomography angiography (CTA) with 40-mL contrast agent compared to 100-kVp standard-pitch CTA with 60-mL contrast agent. MATERIALS AND METHODS:Sixty-seven patients (51 men and 16 women; mean age, 55 ± 14 year...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2015.03.007

    authors: Zhang LJ,Zhao YE,Schoepf UJ,Mangold S,Felmly LM,Li X,Tang CX,Zhou CS,Qi L,Lu GM

    更新日期:2015-07-01 00:00:00

  • Glioma recurrence versus radiation necrosis? A pilot comparison of arterial spin-labeled, dynamic susceptibility contrast enhanced MRI, and FDG-PET imaging.

    abstract:RATIONALE AND OBJECTIVES:Distinguishing recurrent glial tumor from radiation necrosis can be challenging. The purpose of this pilot study was to preliminarily compare unenhanced arterial spin-labeled (ASL) imaging, dynamic susceptibility contrast-enhanced cerebral blood volume (DSCE-CBV) magnetic resonance imaging, and...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2009.10.024

    authors: Ozsunar Y,Mullins ME,Kwong K,Hochberg FH,Ament C,Schaefer PW,Gonzalez RG,Lev MH

    更新日期:2010-03-01 00:00:00

  • Iodixanol and ioxaglate in adult aortography and peripheral arteriography: a phase III clinical trial.

    abstract:RATIONALE AND OBJECTIVES:This study compared the safety and efficacy of iodixanol with those of ioxaglate in adult patients undergoing aortography or peripheral arteriography. METHODS:Forty-six patients were enrolled in this controlled, randomized, double-blind, two-center study. The patients were monitored for advers...

    journal_title:Academic radiology

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1016/s1076-6332(05)80368-x

    authors: Rosenblum JD,Siegel EL,Leef J,Eckard DA,Lu CT

    更新日期:1996-09-01 00:00:00

  • Radiologic consultation: effect on inpatient diagnostic imaging evaluation in a teaching hospital.

    abstract:RATIONALE AND OBJECTIVES:The authors evaluated radiologic consultation affecting resident physician ordering of relatively expensive imaging studies. METHODS:Requisitions (n = 180) for expensive imaging studies from three general medicine floors (two consultation floors, one control floor) were prospectively evaluated...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(05)80294-6

    authors: Gottlieb RH,Hollenberg GM,Fultz PJ,Rubens DJ

    更新日期:1997-03-01 00:00:00

  • Normative analysis of pulmonary vein drainage patterns on multidetector CT with measurements of pulmonary vein ostial diameter and distance to first bifurcation.

    abstract:RATIONALE AND OBJECTIVES:To document the frequency of normal and anomalous drainage patterns of the pulmonary veins, and to establish normal values for pulmonary vein ostial diameters, and distance to first bifurcation using multidetector computed tomography, as pertinent to ablation procedures for atrial fibrillation....

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2006.11.004

    authors: Cronin P,Kelly AM,Desjardins B,Patel S,Gross BH,Kazerooni EA,Morady F,Oral H,Carlos RC

    更新日期:2007-02-01 00:00:00

  • A robust method for estimating regional pulmonary parameters in presence of noise.

    abstract:RATIONALE AND OBJECTIVES:Estimation of regional lung function parameters from hyperpolarized gas magnetic resonance images can be very sensitive to presence of noise. Clustering pixels and averaging over the resulting groups is an effective method for reducing the effects of noise in these images, commonly performed by...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2008.03.002

    authors: Guyer RA,Hellman MD,Emami K,Kadlecek S,Cadman RV,Yu J,Vadhat V,Ishii M,Woodburn JM,Law M,Rizi RR

    更新日期:2008-06-01 00:00:00

  • Evaluation of hardware-related geometrical distortion in structural MRI at 7 Tesla for image-guided applications in neurosurgery.

    abstract:RATIONALE AND OBJECTIVES:Geometrical distortion is a well-known problem in structural magnetic resonance imaging (MRI), leading to pixel shifts with variations up to several millimeters. Because the main factors of geometrical distortion are proportional to B(0), MRI spatial encoding distortions tend to increase with h...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2011.02.011

    authors: Dammann P,Kraff O,Wrede KH,Özkan N,Orzada S,Mueller OM,Sandalcioglu IE,Sure U,Gizewski ER,Ladd ME,Gasser T

    更新日期:2011-07-01 00:00:00

  • A segmentation-based method for metal artifact reduction.

    abstract:RATIONALE AND OBJECTIVES:We propose a novel segmentation-based interpolation method to reduce the metal artifacts caused by surgical aneurysm clips. MATERIALS AND METHODS:Our method consists of five steps: coarse image reconstruction, metallic object segmentation, forward-projection, projection interpolation, and fina...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2006.12.015

    authors: Yu H,Zeng K,Bharkhada DK,Wang G,Madsen MT,Saba O,Policeni B,Howard MA,Smoker WR

    更新日期:2007-04-01 00:00:00

  • Subtraction CT angiography of the lower extremities: single volume subtraction versus multi-segmented volume subtraction.

    abstract:RATIONALE AND OBJECTIVES:To validate the hypothesis that a multisegmented approach during subtraction computed tomography (CT) angiography of the lower extremities can improve bone removal efficiency by suppressing regional motion. MATERIALS AND METHODS:The institutional review board of our hospital approved this retr...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2011.01.024

    authors: Lee IJ,Chung JW,Hong H,Yin YH,Kim S,Park EA,Lee W

    更新日期:2011-07-01 00:00:00

  • Quality of communication: different patterns of reporting the location of the tip of a nasogastric tube.

    abstract:PURPOSE:This investigation is part of a prospective National Institutes of Health-funded study evaluating three different methods for estimating the optimal length for placement of a new nasogastric (NG) tube. Abdomen radiographs were required to determine the location of the tube tip. Our objective was to analyze diff...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2012.02.007

    authors: Cohen MD,Ellett M

    更新日期:2012-06-01 00:00:00

  • Effects of Patient Size and Radiation Dose on Iodine Quantification in Dual-Source Dual-Energy CT.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to investigate the potential effects of patient size and radiation dose on the accuracy of iodine quantification using dual-source dual-energy computed tomography (CT). MATERIALS AND METHODS:Three phantoms representing different patient sizes were constructed, con...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2019.12.027

    authors: Jiang X,Yang X,Hintenlang DE,White RD

    更新日期:2021-01-01 00:00:00

  • CT angiography with gadolinium-based contrast media.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the potential use of gadolinium (Gd)-based contrast media, especially that of Gadovist, a 1-molar Gd medium, in computed tomography (CT) and compare our findings with standard iodinated contrast media. MATERIAL AND METHODS:Using a live rabbit and an acrylic CT body phantom for comp...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2006.03.019

    authors: Bonvento MJ,Moore WH,Button TM,Weinmann HJ,Yakupov R,Dilmanian FA

    更新日期:2006-08-01 00:00:00

  • Automatic prediction of infarct growth in acute ischemic stroke from MR apparent diffusion coefficient maps.

    abstract:RATIONALE AND OBJECTIVES:We introduce a new approach to the prediction of final infarct growth in human acute ischemic stroke based on image analysis of the apparent diffusion coefficient (ADC) maps obtained from magnetic resonance imaging. Evidence from multiple previous studies indicate that ADC maps are likely to re...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2007.07.007

    authors: Montiel NH,Rosso C,Chupin N,Deltour S,Bardinet E,Dormont D,Samson Y,Baillet S

    更新日期:2008-01-01 00:00:00

  • Reinventing the apprenticeship: the hot seat in the digital era.

    abstract:RATIONALE AND OBJECTIVES:Describe new interactive digital teaching methods for medical student education in radiology and evaluate student responses. MATERIALS AND METHODS:Third- and fourth-year medical students on radiology clerkship were taught using either film-based "hot seat" format, digital "hot seat," or didact...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2004.07.017

    authors: Su TJ,Shaffer K

    更新日期:2004-11-01 00:00:00

  • Detectability of simulated brain activation using dual radioisotope SPECT based on size and intensity of the focal hyperactivity.

    abstract:RATIONALE AND OBJECTIVES:Simultaneous single-photon emission computed tomography (SPECT) neuroimaging with both technetium-99m (99mTc) hexamethylpropyleneamine oxime (HMPAO) and iodine-123 (123I) N-isopropyl-iodoamphetamine is a recently introduced method with potential for assessing activation phenomena in the brain. ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(05)80242-9

    authors: Bushnell DL,Madsen M,Cremer S,Kahn D,Kirchner PT

    更新日期:1995-01-01 00:00:00

  • Diagnostic Performance of MR Imaging-based Features and Texture Analysis in the Differential Diagnosis of Ovarian Thecomas/Fibrothecomas and Uterine Fibroids in the Adnexal Area.

    abstract:RATIONALE AND OBJECTIVES:To investigate the value of MRI-based features and texture analysis (TA) in the differential diagnosis between ovarian thecomas/fibrothecomas (OTCA/f-TCAs) and uterine fibroids in the adnexal area (UF-iaas). MATERIALS AND METHODS:This retrospective study included 16 OTCA/f-TCA and 37 UF-iaa pa...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2019.12.025

    authors: Wei C,Chen YL,Li XX,Li NY,Wu YY,Lin TT,Wang CB,Zhang P,Dong JN,Yu YQ

    更新日期:2020-10-01 00:00:00

  • Effect of automatic tube current modulation on radiation dose and image quality for low tube voltage multidetector row CT angiography: phantom study.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the effect of automatic tube current modulation on radiation dose and image quality for low tube voltage computed tomography (CT) angiography. MATERIALS AND METHODS:An anthropomorphic phantom was scanned with a 64-section CT scanner using following tube voltages: 140 kVp (Protocol ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2009.02.021

    authors: Schindera ST,Nelson RC,Yoshizumi T,Toncheva G,Nguyen G,DeLong DM,Szucs-Farkas Z

    更新日期:2009-08-01 00:00:00

  • Determining optimal acquisition parameters for computed tomography coronary angiography: evaluation of a software-assisted, breathhold exam simulation.

    abstract:RATIONALE AND OBJECTIVES:Scanning parameters used in multislice computed tomographic (MSCT) coronary angiography should be adapted to patients' heart rates. The aim of this study was to evaluate the rate of success of a software-assisted scan simulation to determine optimal gantry rotation time prior to MSCT coronary a...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2008.08.016

    authors: Engelken FJ,Lembcke A,Hamm B,Dewey M

    更新日期:2009-02-01 00:00:00