Effects of Patient Size and Radiation Dose on Iodine Quantification in Dual-Source Dual-Energy CT.

Abstract:

RATIONALE AND OBJECTIVES:The purpose of this study was to investigate the potential effects of patient size and radiation dose on the accuracy of iodine quantification using dual-source dual-energy computed tomography (CT). MATERIALS AND METHODS:Three phantoms representing different patient sizes were constructed, containing iodine inserts with concentrations from 0 to 20 mg/ml. Dual-energy CT scans were performed at six dose levels from 2 to 30 mGy. Iodine concentrations were measured using a three-material-decomposition algorithm and their accuracy was assessed. RESULTS:In a small phantom, iodine quantification was accurate and consistent at all dose levels. In a medium phantom, minor underestimations were observed, and the results were consistent except at low dose. In the large phantom, more significant underestimation of iodine concentration was observed at higher doses (≥15 mGy), which was attributed to the beam-hardening effect. At lower doses, increasing upward bias was observed in the CT number, leading to significant overestimations of both iodine concentration and fat fraction, which was attributed to the photon-starvation effect. The severity of the latter effect was determined by mA instead of mAs, suggesting that the electronic noise, rather than the quantum noise, was responsible for the bias. Using higher kVp for the low-energy tube was found to alleviate these effects. CONCLUSION:Reliable iodine quantification can be achieved using dual-source CT, but the result can be affected by patient size and dose rate. In large patients, biases may occur due to the beam-hardening and the photon-starvation effects, in which case higher dose rate and higher kVp are recommended to minimize these effects.

journal_name

Acad Radiol

journal_title

Academic radiology

authors

Jiang X,Yang X,Hintenlang DE,White RD

doi

10.1016/j.acra.2019.12.027

subject

Has Abstract

pub_date

2021-01-01 00:00:00

pages

96-105

issue

1

eissn

1076-6332

issn

1878-4046

pii

S1076-6332(20)30026-X

journal_volume

28

pub_type

杂志文章
  • Functional MR imaging of vision in the deaf.

    abstract:RATIONALE AND OBJECTIVES:Early loss of a sensory modality has been associated with cortical reorganization in both animal models and humans. The purpose of this study was to map visual activation with functional magnetic resonance (MR) imaging and to document possible developmental reorganization in the temporal lobe c...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/S1076-6332(03)80684-0

    authors: Shibata DK,Kwok E,Zhong J,Shrier D,Numaguchi Y

    更新日期:2001-07-01 00:00:00

  • Isotropic reconstruction of SPECT data using OSEM3D: correlation with CT.

    abstract:RATIONALE AND OBJECTIVES:A statistical based iterative single-photon emission-computed tomography (SPECT) reconstruction algorithm (OSEM) modeling the depth-dependent collimator response in three dimensions has recently been introduced (OSEM3D). The aim of this study was to evaluate the axial shape fidelity of OSEM3D i...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2005.12.004

    authors: Römer W,Reichel N,Vija HA,Nickel I,Hornegger J,Bautz W,Kuwert T

    更新日期:2006-04-01 00:00:00

  • CT detection of serious internal and skeletal injuries in patients with pelvic fractures.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to determine the percentage of patients with known pelvic fractures who have additional findings of intraabdominal injury, as diagnosed at abdominal computed tomography (CT), and to determine if patients with specific types or patterns of fractures are more likely ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/S1076-6332(99)80209-8

    authors: Killeen KL,DeMeo JH

    更新日期:1999-04-01 00:00:00

  • 3D Printing of Preoperative Simulation Models of a Splenic Artery Aneurysm: Precision and Accuracy.

    abstract:RATIONALE AND OBJECTIVES:Three-dimensional (3D) printing is attracting increasing attention in the medical field. This study aimed to apply 3D printing to the production of hollow splenic artery aneurysm models for use in the simulation of endovascular treatment, and to evaluate the precision and accuracy of the simula...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2016.12.015

    authors: Takao H,Amemiya S,Shibata E,Ohtomo K

    更新日期:2017-05-01 00:00:00

  • Communicating Radiology Test Results: Are Our Phone Calls Excessive, Just Right, or Not Enough?

    abstract:RATIONALE AND OBJECTIVES:This study aimed to determine the preferences of radiology and referring provider residents regarding direct communication of radiology test results. METHODS:This Health Insurance Portability and Accountability Act-compliant quality improvement effort was exempt from institutional review board...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2017.09.015

    authors: Bhatti ZS,Brown RKJ,Kazerooni EA,Davenport MS

    更新日期:2018-03-01 00:00:00

  • Completion of colorectal cancer screening in women attending screening mammography.

    abstract:RATIONALE AND OBJECTIVES:The American Cancer Society (ACS) and the United States Preventive Services Task Force (USPSTF) recommend colorectal cancer (CRC) screening to begin at age 50 in individuals at average risk for CRC. To estimate rate at which women eligible for CRC screening at the time of screening mammography ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2004.07.025

    authors: Molina L,Carlos RC,Mark Fendrick A,Abrahamse PH,Dong Q,Bernstein SJ

    更新日期:2004-11-01 00:00:00

  • Implementation of graphic user interface screen capture solution for workflow assessment of abdominal MR examinations valuable tool to analyze discrepancies in expected and experienced MR table time.

    abstract:RATIONALE AND OBJECTIVES:The aim of this study was to assess if graphical user interface screen-capture software applied to a magnetic resonance (MR) hardware console could nonintrusively allow the analysis of discrepancies between expected and experienced MR table time. MATERIALS AND METHODS:Individual MR examination...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2009.05.009

    authors: Roth CJ,Boll DT,Chea YW,Wall LK,Merkle EM

    更新日期:2009-10-01 00:00:00

  • When and why might a computer-aided detection (CAD) system interfere with visual search? An eye-tracking study.

    abstract:RATIONAL AND OBJECTIVES:Computer-aided detection (CAD) systems are intended to improve performance. This study investigates how CAD might actually interfere with a visual search task. This is a laboratory study with implications for clinical use of CAD. METHODS:Forty-seven naive observers in two studies were asked to ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2012.05.013

    authors: Drew T,Cunningham C,Wolfe JM

    更新日期:2012-10-01 00:00:00

  • Multidisciplinary gastrointestinal cancer clinic: abdominal radiologist as active participant.

    abstract:RATIONALE AND OBJECTIVES:Abdominal radiologists actively participated and provided subspecialty radiologic expertise in a multidisciplinary gastrointestinal cancer clinic that served a tertiary referral center. The purpose of this study was to evaluate the feasibility and nonradiologists' opinions of this new approach ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(98)80564-3

    authors: Silverman SG,Khorasani R,Adams DF,Phillips MD,Sica GT,Mayer RJ

    更新日期:1998-10-01 00:00:00

  • USMLE Step 3 Scores Have Value in Predicting ABR Core Examination Outcome and Performance: A Multi-institutional Study.

    abstract:RATIONALE AND OBJECTIVES:We analyzed multi-institutional data to determine if Step 3 performance tiers can identify radiology residents with increased risk of Core examination failure and submean performance. MATERIALS AND METHODS:We collected Step 3 scores (USMLE Step 3 or COMLEX Level 3) and American Board of Radiol...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2020.06.032

    authors: Patel MD,Benefield T,Hunt KN,Tomblinson CM,Ali K,DeBenedectis CM,England E,Gaviola GC,Ho CP,Jay AK,Milburn JM,Ong S,Robbins JB,Sarkany DS,Heitkamp DE,Jordan SG

    更新日期:2020-08-06 00:00:00

  • Histological Subtypes Classification of Lung Cancers on CT Images Using 3D Deep Learning and Radiomics.

    abstract:RATIONALE AND OBJECTIVES:Histological subtypes of lung cancers are critical for clinical treatment decision. In this study, we attempt to use 3D deep learning and radiomics methods to automatically distinguish lung adenocarcinomas (ADC), squamous cell carcinomas (SCC), and small cell lung cancers (SCLC) respectively on...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2020.06.010

    authors: Guo Y,Song Q,Jiang M,Guo Y,Xu P,Zhang Y,Fu CC,Fang Q,Zeng M,Yao X

    更新日期:2020-07-01 00:00:00

  • Optimization of shaded surface display for CT angiography.

    abstract:RATIONALE AND OBJECTIVES:The authors performed this study to determine the optimum threshold for performing computed tomographic (CT) angiography with shaded surface display (SSD). MATERIALS AND METHODS:A dedicated phantom was developed with an 8-mm luminal diameter. Each of 19 vessels had stenoses ranging from 0% to ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/S1076-6332(03)80641-4

    authors: Addis KA,Hopper KD,Iyriboz TA,Kasales CJ,Liu Y,Wise SW

    更新日期:2001-10-01 00:00:00

  • Combining Washout and Noncontrast Data From Adrenal Protocol CT: Improving Diagnostic Performance.

    abstract:RATIONALE AND OBJECTIVES:To determine if combination of washout and noncontrast data from delayed adrenal computed tomography (CT) improves diagnostic performance, and demonstration of an optimizing analytical framework. MATERIALS AND METHODS:This retrospective study consisted of 97 adrenal lesions, in 96 patients, wi...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2017.12.005

    authors: Ng CS,Altinmakas E,Wei W,Ghosh P,Li X,Grubbs EG,Perrier NA,Prieto VG,Lee JE,Hobbs BP

    更新日期:2018-07-01 00:00:00

  • Bronchial arterial response to contrast medium.

    abstract:RATIONALE AND OBJECTIVES:Contrast agents have been shown to produce vasodilatory responses in several vascular beds. To our knowledge, however, their effect on the bronchial vasculature has not been examined. Clinically, contrast-induced bronchial vasodilation could potentially exacerbate life-threatening pulmonary hem...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(05)80700-7

    authors: Baile EM,Mayo JR,Sasaki F,Bai TR,Paré PD

    更新日期:1995-11-01 00:00:00

  • Full field digital mammography and breast density: comparison of calibrated and noncalibrated measurements.

    abstract:RATIONALE AND OBJECTIVES:Mammographic breast density is an important and widely accepted risk factor for breast cancer. A statement about breast density in the mammographic report is becoming a requirement in many States. However, there is significant inter-observer variation between radiologists in their interpretatio...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2011.07.011

    authors: Heine JJ,Fowler EE,Flowers CI

    更新日期:2011-11-01 00:00:00

  • MR imaging of the temporomandibular joint: a validation experiment in vitro.

    abstract:RATIONALE AND OBJECTIVES:The authors compared magnetic resonance (MR) image quality obtained from 3- and 1-mm-thick sections in the depiction of the temporomandibular joint (TMJ) and its adjacent structures. MATERIALS AND METHODS:Eight TMJ specimens from four adult cadaver heads were depicted with MR imaging. Both 3- ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/S1076-6332(99)80116-0

    authors: Cavalcanti MG,Lew D,Ishimaru T,Ruprecht A

    更新日期:1999-11-01 00:00:00

  • Correlation Between Radiology ACGME Case Logs Values and ABR Core Exam Pass Rate.

    abstract:RATIONALE AND OBJECTIVES:There is discordance between the American Board of Radiology (ABR) and many radiology trainees with respect to the most appropriate means to prepare for the ABR Core Examination. Whereas the ABR suggests that participation in routine clinical examination interpretation best prepares a trainee f...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2019.10.004

    authors: Nickerson JP,Koski C,Anderson JC,Beckett B,Jackson VP

    更新日期:2020-02-01 00:00:00

  • Management of Splenic Trauma in Contemporary Clinical Practice: A National Trauma Data Bank Study.

    abstract:BACKGROUND:To evaluate the utilization and efficacy of various treatments for management of adult patients with splenic trauma, highlighting the evolving role of splenic artery embolization. MATERIALS AND METHODS:The National Trauma Data Bank (NTDB) was queried for patients who sustained splenic trauma between 2007 an...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2020.11.010

    authors: Chahine AH,Gilyard S,Hanna TN,Fan S,Risk B,Johnson JO,Duszak R Jr,Newsome J,Xing M,Kokabi N

    更新日期:2020-12-04 00:00:00

  • Identification of noncalcified plaque in young persons with diabetes: an opportunity for early primary prevention of coronary artery disease identified with low-dose coronary computed tomographic angiography.

    abstract:PURPOSE:Coronary computed tomographic angiography (CTA) is a valuable tool for assessing coronary artery disease (CAD). Although statin use is widely recommended for persons with diabetes older than age 40, little is known about the presence and severity of CAD in younger patients with diabetes mellitus (DM). We evalua...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2012.03.013

    authors: Madaj PM,Budoff MJ,Li D,Tayek JA,Karlsberg RP,Karpman HL

    更新日期:2012-07-01 00:00:00

  • Ultrasound biomicroscopy for the detection of early osteoarthritis in an animal model.

    abstract:RATIONALE AND OBJECTIVES:Osteoarthritis (OA) is a common disease, and early diagnosis is essential for preventing further cartilage destruction and decreasing severe complications. Ultrasound biomicroscopy (UBM) is sensitive for detecting minute lesions in tissue because of its higher resolution, but its B-mode charact...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2010.09.011

    authors: Wang Y,Guo Y,Zhang L,Niu H,Xu M,Zhao B,Wan W

    更新日期:2011-02-01 00:00:00

  • Computer-aided diagnosis of soft-tissue tumors using sonographic morphologic and texture features.

    abstract:RATIONALE AND OBJECTIVES:The aim of this study was to develop a computer-aided diagnosis (CAD) system in assessing the sonographic morphologic and texture features of soft-tissue tumors. MATERIALS AND METHODS:The retrospective study involved 114 pathology proven cases including 73 benign and 41 malignant soft-tissue t...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2009.07.024

    authors: Chen CY,Chiou HJ,Chou SY,Chiou SY,Wang HK,Chou YH,Chiang HK

    更新日期:2009-12-01 00:00:00

  • Quantitative Multivolume Proton-Magnetic Resonance Imaging in Lung Transplant Recipients: Comparison With Computed Tomography and Spirometry.

    abstract:RATIONALE AND OBJECTIVES:Acute and chronic graft rejection remains the major problem in clinical surveillance of lung-transplanted patients and early detection of complications is of capital importance to allow the optimal therapeutic option. The aim of this study was to investigate the role of quantitative non contras...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2020.05.026

    authors: Pennati F,Salito C,Borzani I,Carrafiello G,Morlacchi LC,Vaira V,Nosotti M,Palleschi A,Aliverti A

    更新日期:2020-07-08 00:00:00

  • Quality of communication: different patterns of reporting the location of the tip of a nasogastric tube.

    abstract:PURPOSE:This investigation is part of a prospective National Institutes of Health-funded study evaluating three different methods for estimating the optimal length for placement of a new nasogastric (NG) tube. Abdomen radiographs were required to determine the location of the tube tip. Our objective was to analyze diff...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2012.02.007

    authors: Cohen MD,Ellett M

    更新日期:2012-06-01 00:00:00

  • A preliminary report on the role of spatial frequency analysis in the perception of breast cancers missed at mammography screening.

    abstract:RATIONALE AND OBJECTIVES:Because several factors are involved in cancer detection, a malignant lesion that is visible on a mammogram will not necessarily be reported by the radiologist reading the case. Indeed, a significant fraction of screening-detected cancers are visible in retrospect, and were perceived by the rad...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2004.04.015

    authors: Mello-Thoms C,Chapman B

    更新日期:2004-08-01 00:00:00

  • Relating dose of contrast media administered to uptake and washout of malignant lesions on DCEMRI of the breast.

    abstract:RATIONALE AND OBJECTIVES:To quantify the relationship between dose of contrast administered and contrast kinetics of malignant breast lesions. MATERIALS AND METHODS:A total of 108 patients with 120 malignant lesions were selected for an institutional review board-approved review. Dynamic magnetic resonance protocol: o...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2009.06.015

    authors: Jansen SA,Fan X,Yang C,Shimauchi A,Karczmar G,Newstead GM

    更新日期:2010-01-01 00:00:00

  • Teaching Radiology Physics Interactively with Scientific Notebook Software.

    abstract:RATIONALE AND OBJECTIVES:The goal of this study is to demonstrate how the teaching of radiology physics can be enhanced with the use of interactive scientific notebook software. METHODS:We used the scientific notebook software known as Project Jupyter, which is free, open-source, and available for the Macintosh, Windo...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2017.11.024

    authors: Richardson ML,Amini B

    更新日期:2018-06-01 00:00:00

  • Overdiagnosis of breast cancer at screening is clinically insignificant.

    abstract::Long-term follow-up of randomized trials provide the most accurate estimates of overdiagnosis. Estimates from follow-up of service screening studies are almost as accurate if there is sufficient adjustment for lead time and risk status. When properly analyzed data from both of these types of trials indicate that the r...

    journal_title:Academic radiology

    pub_type: 杂志文章,meta分析,评审

    doi:10.1016/j.acra.2015.01.020

    authors: Feig SA

    更新日期:2015-08-01 00:00:00

  • Interobserver and intraobserver variability in the assessment of pulmonary nodule size on CT using film and computer display methods.

    abstract:RATIONALE AND OBJECTIVES:A critical element in determining biologic behavior of pulmonary nodules is volume and temporal volume change. We evaluate variability in nodule volume among readers and measuring methods. MATERIALS AND METHODS:55 small (<2 cm) lung nodules were measured in long- and short-axis dimensions inde...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2005.04.009

    authors: Bogot NR,Kazerooni EA,Kelly AM,Quint LE,Desjardins B,Nan B

    更新日期:2005-08-01 00:00:00

  • Analysis of statistical biases in studies used to formulate guidelines: the case of arrhythmogenic right ventricular cardiomyopathy (ARVC) the case of ARVC.

    abstract:RATIONALE AND OBJECTIVES:To analyze the statistical biases in the studies used to derive cardiac magnetic resonance-based major and minor criteria for the diagnosis of arrhythmogenic right ventricular cardiomyopathy (ARVC). MATERIALS AND METHODS:ARVC is a rare disorder of the heart that can lead to sudden death in you...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2015.04.009

    authors: Cook TS,Zimmerman SL,Jha S

    更新日期:2015-08-01 00:00:00

  • Evaluation of analgesic effect of equimolar mixture of oxygen and nitrous oxide inhalation during percutaneous biopsy of focal liver lesions: a double-blind randomized study.

    abstract:RATIONALE AND OBJECTIVES:Percutaneous liver biopsy for tumors performed under local anesthesia is still a painful procedure. The aim of this study was to evaluate the patient's reaction and the analgesic efficacy and safety of an equimolar mixture of oxygen and nitrous oxide (EMONO) inhalation. MATERIALS AND METHODS:A...

    journal_title:Academic radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.acra.2011.01.025

    authors: Meskine N,Vullierme MP,Zappa M,d'Assignies G,Sibert A,Vilgrain V

    更新日期:2011-07-01 00:00:00