Abstract:
RATIONALE AND OBJECTIVES:To evaluate the potential use of gadolinium (Gd)-based contrast media, especially that of Gadovist, a 1-molar Gd medium, in computed tomography (CT) and compare our findings with standard iodinated contrast media. MATERIAL AND METHODS:Using a live rabbit and an acrylic CT body phantom for comparative CT imaging of Gd- and I-based media. The images were acquired at 80, 100, and 120 kVp, using fixed standard beam filtration. The phantom study used serial dilutions of the Magnevist and Ultravist 300 (2.4-molar I), whereas the animal study used different volumes of Gadovist, Magnevist (0.5 molar Gd), and Ultravist administered intravenously. RESULTS:At 80 kVp for the same injection volumes of Gadovist and Ultravist, the image contrast enhancement of the aorta with Gadovist was 40% lower than that of Ultravist. In the phantom studies, however, for the same kVp settings the CT image contrast was up to fourfold higher for Gd compared with iodine when comparing the same molar concentrations of the two elements in the solutions. CONCLUSION:These results indicate a potential of Gd-based media for clinical CT angiography and provide incentive for further investigation of this subject.
journal_name
Acad Radioljournal_title
Academic radiologyauthors
Bonvento MJ,Moore WH,Button TM,Weinmann HJ,Yakupov R,Dilmanian FAdoi
10.1016/j.acra.2006.03.019subject
Has Abstractpub_date
2006-08-01 00:00:00pages
979-85issue
8eissn
1076-6332issn
1878-4046pii
S1076-6332(06)00234-0journal_volume
13pub_type
杂志文章abstract:RATIONALE AND OBJECTIVES:To determine graduating medical students' perceptions of radiology and to document changes in their perceptions since they entered medical school. MATERIALS AND METHODS:A survey questionnaire was distributed to 213 graduating students. Questions were similar to those answered by the same group...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/s1076-6332(97)80211-5
更新日期:1997-08-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Our primary aim was to improve radiology reports by increasing concordance of target lesion measurements with oncology records using radiology preprocessors (RP). Faster notification of incidental actionable findings to referring clinicians and clinical radiologist exam interpretation time savi...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2019.09.014
更新日期:2020-01-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To retrospectively analyze the significance of 3.0-T contrast-enhanced (CE) magnetic resonance angiography (MRA) with calf compression in the lower limbs of diabetic patients with peripheral vascular disease. MATERIALS AND METHODS:Sixty-one type 2 diabetes patients underwent both MRA and digit...
journal_title:Academic radiology
pub_type: 杂志文章,随机对照试验
doi:10.1016/j.acra.2011.01.013
更新日期:2011-06-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The Mammography Quality Standards Act requires practices to measure limited aspects of their performance. The authors conducted this study to calculate the differences in measurements of sensitivity and specificity due only to differences in the definitions used in the analysis. This included d...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/s1076-6332(00)80057-4
更新日期:2000-12-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Although the spiculation levels of breast mass boundaries are a primary sign of malignancy for masses detected on mammography, developing an automated computerized method to detect spiculation levels and quantitatively evaluating the performance of such a method is a difficult task. The objecti...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2008.07.015
更新日期:2008-12-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:In our earlier studies, we reported an evidence-based computer-assisted decision (CAD) system for location-specific interrogation of mammograms. A content-based image retrieval framework with information theoretic (IT) similarity measures serves as the foundation for this system. Specifically, ...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2007.12.013
更新日期:2008-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Digitizing images for use in case presentations based on hardcopy films, slides, photographs, negatives, books, and videos can present a challenging task. Scanners and digital cameras have become standard tools of the trade. Unfortunately, use of these devices to digitize multiple images in man...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/s1076-6332(03)00010-2
更新日期:2003-08-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To evaluate clinical and imaging features associated with adequacy of the hepatocyte phase (HP) in gadoxetate disodium-enhanced liver magnetic resonance imaging (MRI) in patients without chronic liver disease (CLD). MATERIALS AND METHODS:This was a retrospective institutional review board-appr...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2014.02.005
更新日期:2014-06-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:This study aimed to test high temporal resolution dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) for different zones of the prostate and evaluate its performance in the diagnosis of prostate cancer (PCa). Determine whether the addition of ultrafast DCE-MRI improves the perform...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2017.10.004
更新日期:2018-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Morphologic changes of the human brain during healthy aging provide useful reference knowledge for age-related brain disorders. The aim of this study was to explore age-related global and regional morphological changes of healthy adult brains. MATERIALS AND METHODS:T1-weighted magnetic resonan...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2012.03.006
更新日期:2012-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to develop and test new assistive devices to aid in the performance of safe, easy, and accurate microwave thermocoagulation therapy guided by magnetic resonance (MR) imaging. MATERIALS AND METHODS:An open-configuration MR imager with an optical tracking system for...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/s1076-6332(03)80043-0
更新日期:2003-02-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors performed this study to determine if bronchial wall thickening is present in children with moderate to severe asthma during periods free from clinical bronchoconstriction. MATERIALS AND METHODS:The authors obtained low (radiation) dose thin-section computed tomographic (CT) scans i...
journal_title:Academic radiology
pub_type: 杂志文章,多中心研究
doi:10.1016/S1076-6332(03)80535-4
更新日期:2001-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to determine the electronic requirements for supporting evidence-based radiology in today's medical environment. MATERIALS AND METHODS:A software engineering technique, use case modeling, was performed for several clinical settings to determine the use of imaging ...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/s1076-6332(03)80311-2
更新日期:2002-06-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:We propose a novel segmentation-based interpolation method to reduce the metal artifacts caused by surgical aneurysm clips. MATERIALS AND METHODS:Our method consists of five steps: coarse image reconstruction, metallic object segmentation, forward-projection, projection interpolation, and fina...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2006.12.015
更新日期:2007-04-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The study aim is to evaluate the quality of radiology requisitions for plain film radiographs on intensive care unit (ICU) patients. MATERIALS AND METHODS:Radiology requisitions for 58 patients in ICU units at our children's hospital and the corresponding original orders for the study, written...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2005.10.017
更新日期:2006-02-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Rotator cuff disorders are prevalent and can cause pain and reduced range of motion and strength. Accurate, noninvasive diagnosis of rotator cuff disorders is therefore important. In this work, we study the relationship between several three-dimensional (3D) shape measurements of the supraspina...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2007.06.014
更新日期:2007-10-01 00:00:00
abstract::A group of experts on very large databases, quantitative imaging, data format standards development, image management and communications, and related technologies for cancer imaging met at a recent workshop sponsored by the BIP and discussed the key issues confronting this field. The BIP received recommendations regar...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/s1076-6332(03)80126-5
更新日期:2003-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Diffusion tensor tractography (DTT) for neural fibers of the head-and-neck region at 3T has not been reported. The purpose of this study was to evaluate the feasibility of using DTT for visualizing neural fibers in the head-and-neck region at 3T and to explore the use of this method in patients...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2009.01.019
更新日期:2009-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The development of curriculum guidelines for radiology residency has been found to be favored by 80% of program directors (PDs) nationwide. I surveyed PDs to develop a consensus of opinion concerning minimum training requirements in the subspecialty rotations. METHODS:A survey developed by mem...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/s1076-6332(96)80013-4
更新日期:1996-06-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors evaluated the reliability and validity of an experimental radiology faculty appraisal instrument. MATERIALS AND METHODS:Residents from the University of Wisconsin (UW) and Indiana University (IU) were asked to use a previously developed behaviorally based, 53-item experimental facu...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/s1076-6332(98)80266-3
更新日期:1998-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:An automated method for identification and segmentation of acute/subacute ischemic stroke, using the inherent bi-fold symmetry in brain images, is presented. An accurate and automated method for localization of acute ischemic stroke could provide physicians with a mechanism for early detection ...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2008.03.013
更新日期:2008-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The aim of this study was to investigate the effects of exogenous endothelial progenitor cells (EPCs) on the growth and invasiveness of glioma in vivo to provide an experimental basis for the value and safety of using magnetically labeled EPCs as target vectors to detect early infiltration of g...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2011.02.017
更新日期:2011-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The aim of this study is to assess the usefulness of computer-aided three-dimensional (3D) measurement of volume and computed tomography (CT) attenuation values of nodes for diagnosing nodal metastases of lung cancer. MATERIALS AND METHODS:We measured three diameters, their ratios, volume, and...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2013.01.013
更新日期:2013-06-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to determine the feasibility of using transabdominal ultrasonography (US) to monitor tumor growth and response to therapy in a mouse model of orthotopic bladder carcinoma. MATERIALS AND METHODS:Human bladder carcinoma cell suspensions were injected into the bladde...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/s1076-6332(01)90038-8
更新日期:2001-02-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To assess the diagnostic performance of magnetic resonance imaging (MRI) for targeting prostate cancer in patients with previous negative biopsies and elevated prostate-specific antigen (PSA) levels. MATERIALS AND METHODS:Pubmed, Scopus, and Cochrane Library databases were searched to identify...
journal_title:Academic radiology
pub_type: 杂志文章,meta分析,评审
doi:10.1016/j.acra.2014.01.004
更新日期:2014-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:A national needs assessment of radiology program directors was performed to characterize grand rounds (GR) programs, assess the perceived educational value of GR programs, and determine the impact of the recent economic downturn on GR. MATERIALS AND METHODS:A 28-question survey was developed q...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2011.08.015
更新日期:2011-12-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To test the ability of quantitative measures from preoperative dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) to predict, independently and/or with the Katz pathologic nomogram, which breast cancer patients with a positive sentinel lymph node biopsy will have four or more positi...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2013.10.001
更新日期:2014-01-01 00:00:00
abstract::Hematopoietic malignancies that can be encountered in the breast include lymphoma, leukemia, and multiple myeloma/plasmacytoma. These are readily imaged via [18]F-fluorodeoxyglucose position emission tomography (PET)/computed tomography (CT) and can manifest as unilateral, bilateral, single, multiple, round/oval masse...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2010.03.023
更新日期:2010-08-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Emergency department (ED) patients with acute low back pain (LBP) may present with ambiguous clinical findings that pose diagnostic challenges to exclude cauda equina syndrome (CES). As a proof of concept, we aimed to determine the efficacy of a rapid lumbar spine (LS) magnetic resonance imagin...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2017.02.011
更新日期:2017-08-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:(23)Na magnetic resonance imaging is a promising technique for the noninvasive imaging of renal function. Past investigations of the renal corticomedullary [(23)Na] gradient have relied on imaging only in the coronal plane and on cumbersome calculations of [(23)Na], which require the use of ext...
journal_title:Academic radiology
pub_type: 杂志文章
doi:10.1016/j.acra.2012.10.009
更新日期:2013-04-01 00:00:00