Asymmetry analysis in rodent cerebral ischemia models.

Abstract:

RATIONALE AND OBJECTIVES:An automated method for identification and segmentation of acute/subacute ischemic stroke, using the inherent bi-fold symmetry in brain images, is presented. An accurate and automated method for localization of acute ischemic stroke could provide physicians with a mechanism for early detection and potentially faster delivery of effective stroke therapy. MATERIALS AND METHODS:Segmentation of ischemic stroke was performed on magnetic resonance (MR) images of subacute rodent cerebral ischemia. Eight adult male Wistar rats weighing 225-300 g were anesthetized with halothane in a mix of 70% nitrous oxide/30% oxygen. Animal core temperature was maintained at 37 degrees C during the entire surgical procedure, including occlusion of the middle cerebral artery (MCA) and the 90-minute post-reperfusion period. To confirm cerebral ischemia, transcranial measurements of cerebral blood flow were performed with laser-Doppler flowmetry, using 15-mm flexible fiberoptic Doppler probes attached to the skull over the MCA territory. Animal MR scans were performed at 1.5 T using a knee coil. Three experts performed manual tracing of the stroke regions for each rat, using the histologic-stained slices to guide delineation of stroke regions. A strict tracing protocol was followed that included multiple (three) tracings of each stroke region. The volumetric MR image data were processed for each rat by computing the axis of symmetry and extracting statistical dissimilarities. A nonparametric Wilcoxon rank sum test operating on paired windows in opposing hemispheres identified seeds in the pixels exhibiting statistically significant bi-fold mirror asymmetry. Two brain reference maps were used for analysis: an absolute difference map (ADM) and a statistical difference map (SDM). Although an ADM simply displays the absolute difference by subtracting one brain hemisphere from its reflection, SDM highlights regions by labeling pixels exhibiting statistically significant asymmetry. RESULTS:To assess the accuracy of the proposed segmentation method, the surrogate ground truth (the stroke tracing data) was compared to the results of our proposed automated segmentation algorithm. Three accuracy segmentation metrics were utilized: true-positive volume fraction (TPVF), false-positive volume fraction (FPVF), and false-negative volume fraction (FNVF). The mean value of the TPVF for our segmentation method was 0.8877; 95% CI 0.7254 to 1.0500; the mean FPVF was 0.3370, 95% CI -0.0893 to 0.7633; the mean FNVF was 0.1122, 95% CI -0.0502 to 0.2747. CONCLUSIONS:Unlike most segmentation methods that require some degree of manual intervention, our segmentation algorithm is fully automated and highly accurate in identifying regions of brain asymmetry. This approach is attractive for numerous neurologic applications where the operator's intervention should be minimal or null.

journal_name

Acad Radiol

journal_title

Academic radiology

authors

Liu SX,Imielinska C,Laine A,Millar WS,Connolly ES,D'Ambrosio AL

doi

10.1016/j.acra.2008.03.013

subject

Has Abstract

pub_date

2008-09-01 00:00:00

pages

1181-97

issue

9

eissn

1076-6332

issn

1878-4046

pii

S1076-6332(08)00219-5

journal_volume

15

pub_type

杂志文章
  • Feasibility of Respiratory-gated High-pitch Spiral CT:: Free-breathing Inspiratory Image Quality.

    abstract:RATIONALE AND OBJECTIVES:This study aimed to develop and implement a respiratory-gated setup for dual-source computed tomography (CT) at high pitch to examine patients in a reproducible inspiratory phase. MATERIALS AND METHODS:Twenty-one patients underwent free-breathing respiratory-gated chest CT using a high-pitch s...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2015.12.018

    authors: Lell MM,Scharf M,Eller A,Wuest W,Allmendinger T,Fuchs F,Achenbach S,Uder M,May MS

    更新日期:2016-04-01 00:00:00

  • Quantitative Multivolume Proton-Magnetic Resonance Imaging in Lung Transplant Recipients: Comparison With Computed Tomography and Spirometry.

    abstract:RATIONALE AND OBJECTIVES:Acute and chronic graft rejection remains the major problem in clinical surveillance of lung-transplanted patients and early detection of complications is of capital importance to allow the optimal therapeutic option. The aim of this study was to investigate the role of quantitative non contras...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2020.05.026

    authors: Pennati F,Salito C,Borzani I,Carrafiello G,Morlacchi LC,Vaira V,Nosotti M,Palleschi A,Aliverti A

    更新日期:2020-07-08 00:00:00

  • Breast Imaging Boot Camp Meets Milestones 2.0: A Match Made in Clinic.

    abstract:RATIONALE AND OBJECTIVES:Designed to provide broad-based training in all aspects of imaging, the diagnostic radiology residency program must provide educational experiences that not only provide technical training, but also meet accreditation standards. With the breadth of material to cover during training, carefully o...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2020.12.022

    authors: Jordan SG,Lee SS,Rivers LM,Schwartz CJ,Benefield T,Beck Dallaghan GL

    更新日期:2021-01-21 00:00:00

  • Optimization of TI values in inversion-recovery MR sequences for the depiction of fine structures within gray and white matter: separation of globus pallidus interna and externa.

    abstract:RATIONALE AND OBJECTIVES:The authors' purpose was to search the inversion time (TI) values that enable the best differentiation of fine structures in gray matter (gray-gray differentiation). MATERIALS AND METHODS:Seven healthy adult volunteers with no history of neurologic disease or head trauma were recruited and gav...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(03)80789-4

    authors: Nakamura H,Yamada K,Kizu O,Ito H,Nishimura T

    更新日期:2003-01-01 00:00:00

  • Semiautomatic Assessment of the Terminal Ileum and Colon in Patients with Crohn Disease Using MRI (the VIGOR++ Project).

    abstract:RATIONALE AND OBJECTIVES:The objective of this study was to develop and validate a predictive magnetic resonance imaging (MRI) activity score for ileocolonic Crohn disease activity based on both subjective and semiautomatic MRI features. MATERIALS AND METHODS:An MRI activity score (the "virtual gastrointestinal tract ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2017.12.024

    authors: Puylaert CAJ,Schüffler PJ,Naziroglu RE,Tielbeek JAW,Li Z,Makanyanga JC,Tutein Nolthenius CJ,Nio CY,Pendsé DA,Menys A,Ponsioen CY,Atkinson D,Forbes A,Buhmann JM,Fuchs TJ,Hatzakis H,van Vliet LJ,Stoker J,Taylor SA,Vos

    更新日期:2018-08-01 00:00:00

  • Intraindividual comparison of two methods of volumetric breast composition assessment.

    abstract:RATIONALE AND OBJECTIVES:To compare the results of two software-based methods, Quantra and Volpara, for volumetric breast composition assessment. MATERIALS AND METHODS:Four hundred forty-five normal, bilateral, two-view, digital mammograms were included. Breast volume (BV), fibroglandular tissue volume (FTV), and perc...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2014.12.003

    authors: Schmachtenberg C,Hammann-Kloss S,Bick U,Engelken F

    更新日期:2015-04-01 00:00:00

  • A theoretical model using mechanical principles to quantify the physical principles of balloon dilatation.

    abstract:RATIONALE AND OBJECTIVES:Balloon dilatation is a mechanical form of controlled injury used to alleviate vascular stenoses. Several factors influence successful angioplasty. Few mechanical models exist to illustrate the physical principles of balloon dilatation. METHODS:We used mechanical analysis of membrane stresses,...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(05)80340-x

    authors: Kinney TB,Lee MJ,Mueller PR,Waltman AC

    更新日期:1995-05-01 00:00:00

  • Effects of Patient Size and Radiation Dose on Iodine Quantification in Dual-Source Dual-Energy CT.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to investigate the potential effects of patient size and radiation dose on the accuracy of iodine quantification using dual-source dual-energy computed tomography (CT). MATERIALS AND METHODS:Three phantoms representing different patient sizes were constructed, con...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2019.12.027

    authors: Jiang X,Yang X,Hintenlang DE,White RD

    更新日期:2021-01-01 00:00:00

  • FDG PET/CT manifestations of hematopoietic malignancies of the breast.

    abstract::Hematopoietic malignancies that can be encountered in the breast include lymphoma, leukemia, and multiple myeloma/plasmacytoma. These are readily imaged via [18]F-fluorodeoxyglucose position emission tomography (PET)/computed tomography (CT) and can manifest as unilateral, bilateral, single, multiple, round/oval masse...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2010.03.023

    authors: Ginat DT,Puri S

    更新日期:2010-08-01 00:00:00

  • A Breast Radiology Department-operated, Proactive Same-day Program Identifies Pathogenic Breast Cancer Mutations in Unaffected Women.

    abstract:RATIONALE AND OBJECTIVES:Pathogenic mutations in some genes elevate women's breast cancer risk, necessitating risk-reduction strategies. Unfortunately, women are underscreened for cancer risk, and when identified as potentially high risk, women seldom pursue genetic counseling or testing. To improve cancer risk managem...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2020.12.005

    authors: Loving VA,Luiten RC,Siettmann JM,Mina LA

    更新日期:2020-12-15 00:00:00

  • Fast spectroscopic imaging of water and fat resonances to improve the quality of MR images.

    abstract:RATIONALE AND OBJECTIVES:The authors evaluated whether fast spectroscopic imaging of water and fat resonances can produce high-quality anatomic magnetic resonance (MR) images of rodent tumors and human breast. MATERIALS AND METHODS:Fast MR spectroscopic images of eight rats with mammary tumors were acquired by using a...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(98)80226-2

    authors: Kovar DA,Al-Hallaq HA,Zamora MA,River JN,Karczmar GS

    更新日期:1998-04-01 00:00:00

  • Correction of helical CT attenuation values with wide beam collimation: in vitro test with urinary calculi.

    abstract:RATIONALE AND OBJECTIVES:Urinary calculi are now commonly detected with helical computed tomography (CT), and it has been proposed that stone composition can be determined from CT attenuation values. However, typical scans are made with a beam collimation of 5 mm or more, resulting in volume averaging and reduction in ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/S1076-6332(03)80619-0

    authors: Williams JC Jr,Saw KC,Monga AG,Chua GT,Lingeman JE,McAteer JA

    更新日期:2001-06-01 00:00:00

  • Combining Washout and Noncontrast Data From Adrenal Protocol CT: Improving Diagnostic Performance.

    abstract:RATIONALE AND OBJECTIVES:To determine if combination of washout and noncontrast data from delayed adrenal computed tomography (CT) improves diagnostic performance, and demonstration of an optimizing analytical framework. MATERIALS AND METHODS:This retrospective study consisted of 97 adrenal lesions, in 96 patients, wi...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2017.12.005

    authors: Ng CS,Altinmakas E,Wei W,Ghosh P,Li X,Grubbs EG,Perrier NA,Prieto VG,Lee JE,Hobbs BP

    更新日期:2018-07-01 00:00:00

  • Apprenticeships ease the transition to independent call: an evaluation of anxiety and confidence among junior radiology residents.

    abstract:RATIONALE AND OBJECTIVES:The aims of this study were to quantify resident anxiety when beginning independent call and to assess whether an apprenticeship experience (buddy call) can lessen anxiety and improve confidence. MATERIALS AND METHODS:A prospective cohort comparison of two groups of radiology residents beginni...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2011.04.015

    authors: Trout AT,Wang PI,Cohan RH,Bailey JE,Khalatbari S,Myles JD,Dunnick NR

    更新日期:2011-09-01 00:00:00

  • CT angiography with gadolinium-based contrast media.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the potential use of gadolinium (Gd)-based contrast media, especially that of Gadovist, a 1-molar Gd medium, in computed tomography (CT) and compare our findings with standard iodinated contrast media. MATERIAL AND METHODS:Using a live rabbit and an acrylic CT body phantom for comp...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2006.03.019

    authors: Bonvento MJ,Moore WH,Button TM,Weinmann HJ,Yakupov R,Dilmanian FA

    更新日期:2006-08-01 00:00:00

  • Magnetic resonance imaging using hyperpolarized 3He-Gas.

    abstract:RATIONALE AND OBJECTIVES:Current imaging procedures of the lung concentrate on visualization of morphology. Computed tomography is the imaging method of choice for the majority of pulmonary diseases. Functional data are commonly obtained from arterial blood gas analysis, spirometry, and body plethysmography, which all ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(03)00335-0

    authors: Gast KK,Eberle B,Schmiedeskamp J,Kauczor HU

    更新日期:2003-10-01 00:00:00

  • "Structure-Function Imaging of Lung Disease Using Ultrashort Echo Time MRI".

    abstract:RATIONALE AND OBJECTIVES:The purpose of this review is to acquaint the reader with recent advances in ultrashort echo time (UTE) magnetic resonance imaging (MRI) of the lung and its implications for pulmonary MRI when used in conjunction with functional MRI technique. MATERIALS AND METHODS:We provide an overview of re...

    journal_title:Academic radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.acra.2018.12.007

    authors: Torres L,Kammerman J,Hahn AD,Zha W,Nagle SK,Johnson K,Sandbo N,Meyer K,Schiebler M,Fain SB

    更新日期:2019-03-01 00:00:00

  • CT Quantification and Machine-learning Models for Assessment of Disease Severity and Prognosis of COVID-19 Patients.

    abstract:OBJECTIVE:This study was to investigate the CT quantification of COVID-19 pneumonia and its impacts on the assessment of disease severity and the prediction of clinical outcomes in the management of COVID-19 patients. MATERIALS METHODS:Ninety-nine COVID-19 patients who were confirmed by positive nucleic acid test (NAT...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2020.09.004

    authors: Cai W,Liu T,Xue X,Luo G,Wang X,Shen Y,Fang Q,Sheng J,Chen F,Liang T

    更新日期:2020-12-01 00:00:00

  • Helical multidetector row quantitative computed tomography (QCT) precision.

    abstract:RATIONALE AND OBJECTIVES:The impact of varying image acquisition parameters on the precision of measurements using quantitative computed tomography is currently based on studies performed before the advent of helical image acquisition and multidetector-row scanners. The aim of this study was to evaluate helical multide...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2008.08.007

    authors: Bligh M,Bidaut L,White RA,Murphy WA Jr,Stevens DM,Cody DD

    更新日期:2009-02-01 00:00:00

  • Correlation of HER-2/neu overexpression with mammography and age distribution in primary breast carcinomas.

    abstract:RATIONALE AND OBJECTIVES:HER-2/neu is a valuable prognostic and therapeutic marker in primary breast carcinoma. The objective of this study was to determine the mammographic and patient characteristics (age) that correlate with HER-2/neu overexpression in primary breast carcinoma. MATERIALS AND METHODS:HER-2/neu chara...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2006.06.015

    authors: Seo BK,Pisano ED,Kuzimak CM,Koomen M,Pavic D,Lee Y,Cole EB,Lee J

    更新日期:2006-10-01 00:00:00

  • Integrating Radiology and Anatomy Teaching in Medical Education in the UK--The Evidence, Current Trends, and Future Scope.

    abstract::This review article presents the current evidence of the importance of integrating radiology and anatomy in medical education in the UK, a recommendation by a number of key anatomy, education, and radiology organizations. Current evidence highlights that on average only 5% of total teaching time in medical education i...

    journal_title:Academic radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.acra.2015.12.010

    authors: Heptonstall NB,Ali T,Mankad K

    更新日期:2016-04-01 00:00:00

  • Usefulness of additional coronary calcium scoring in low-dose CT coronary angiography with prospective ECG-triggering impact on total effective radiation dose and diagnostic accuracy.

    abstract:RATIONALE AND OBJECTIVES:To determine the impact of additional coronary calcium scoring on total effective radiation dose and diagnostic accuracy of low-dose computed tomography coronary angiography (CTCA) with prospective electrocardiogram (ECG) triggering. MATERIALS AND METHODS:Sixty-one consecutive patients underwe...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2009.09.007

    authors: Husmann L,Herzog BA,Burger IA,Buechel RR,Pazhenkottil AP,von Schulthess P,Wyss CA,Gaemperli O,Landmesser U,Kaufmann PA

    更新日期:2010-02-01 00:00:00

  • Evaluation of analgesic effect of equimolar mixture of oxygen and nitrous oxide inhalation during percutaneous biopsy of focal liver lesions: a double-blind randomized study.

    abstract:RATIONALE AND OBJECTIVES:Percutaneous liver biopsy for tumors performed under local anesthesia is still a painful procedure. The aim of this study was to evaluate the patient's reaction and the analgesic efficacy and safety of an equimolar mixture of oxygen and nitrous oxide (EMONO) inhalation. MATERIALS AND METHODS:A...

    journal_title:Academic radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.acra.2011.01.025

    authors: Meskine N,Vullierme MP,Zappa M,d'Assignies G,Sibert A,Vilgrain V

    更新日期:2011-07-01 00:00:00

  • Evaluation of the quality of radiology requisitions for intensive care unit patients.

    abstract:RATIONALE AND OBJECTIVES:The study aim is to evaluate the quality of radiology requisitions for plain film radiographs on intensive care unit (ICU) patients. MATERIALS AND METHODS:Radiology requisitions for 58 patients in ICU units at our children's hospital and the corresponding original orders for the study, written...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2005.10.017

    authors: Cohen MD,Curtin S,Lee R

    更新日期:2006-02-01 00:00:00

  • Clinical utility of quantitative imaging.

    abstract::Quantitative imaging (QI) is increasingly applied in modern radiology practice, assisting in the clinical assessment of many patients and providing a source of biomarkers for a spectrum of diseases. QI is commonly used to inform patient diagnosis or prognosis, determine the choice of therapy, or monitor therapy respon...

    journal_title:Academic radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.acra.2014.08.011

    authors: Rosenkrantz AB,Mendiratta-Lala M,Bartholmai BJ,Ganeshan D,Abramson RG,Burton KR,Yu JP,Scalzetti EM,Yankeelov TE,Subramaniam RM,Lenchik L

    更新日期:2015-01-01 00:00:00

  • Multivariate Analysis of Radiologists' Usage of Phrases that Convey Diagnostic Certainty.

    abstract:RATIONALE AND OBJECTIVES:To quantify the use of Diagnostic Certainty Phrases (DCP) in radiology reports, including DCPs with good agreement (including "diagnostic of," "unlikely" and "represents") in connoting degree of certainty between providers based on previous studies; and to assess whether modality, presence of a...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2018.10.017

    authors: Lacson R,Odigie E,Wang A,Kapoor N,Shinagare A,Boland G,Khorasani R

    更新日期:2019-09-01 00:00:00

  • Results of the 1993 survey of the American Association of Academic Chief Residents in Radiology.

    abstract:RATIONALE AND OBJECTIVES:A survey of chief residents of academic radiology programs is conducted annually on behalf of the American Association of Academic Chief Residents in Radiology (A3CR2). Data are obtained to improve the training of diagnostic radiology residents and to increase the understanding of radiologists ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(05)80835-9

    authors: Oser AB,Baker SM,Wilson AJ,Evens RG

    更新日期:1994-10-01 00:00:00

  • Software-annotated, digitally photographed, and printed MR images: suitability for publication.

    abstract:RATIONALE AND OBJECTIVES:The authors performed this study to evaluate whether digitally photographed, computer-annotated MR images produced by clinical radiologists and printed with an inexpensive photo printer are suitable for publication. MATERIALS AND METHODS:Laser prints of 20 magnetic resonance images of the brai...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(03)80378-1

    authors: Caruso RD,Postel GC,McDonald CS,Aronson BA,Christensen JD

    更新日期:2002-03-01 00:00:00

  • How Well Does Dual-energy CT with Fast Kilovoltage Switching Quantify CT Number and Iodine and Calcium Concentrations?

    abstract:RATIONALE AND OBJECTIVES:Because it is imperative for understanding the performance of dual-energy computed tomography scanner to determine clinical diagnosis, we aimed to assess the accuracy of quantitative measurements using dual-energy computed tomography with fast kilovoltage switching. MATERIALS AND METHODS:Quant...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2017.11.002

    authors: Ohira S,Karino T,Ueda Y,Nitta Y,Kanayama N,Miyazaki M,Koizumi M,Teshima T

    更新日期:2018-04-01 00:00:00

  • Evidence-based radiology: requirements for electronic access.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to determine the electronic requirements for supporting evidence-based radiology in today's medical environment. MATERIALS AND METHODS:A software engineering technique, use case modeling, was performed for several clinical settings to determine the use of imaging ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(03)80311-2

    authors: Bui AA,Taira RK,Dionisio JD,Aberle DR,El-Saden S,Kangarloo H

    更新日期:2002-06-01 00:00:00