Less Is More: Efficacy of Rapid 3D-T2 SPACE in ED Patients with Acute Atypical Low Back Pain.

Abstract:

RATIONALE AND OBJECTIVES:Emergency department (ED) patients with acute low back pain (LBP) may present with ambiguous clinical findings that pose diagnostic challenges to exclude cauda equina syndrome (CES). As a proof of concept, we aimed to determine the efficacy of a rapid lumbar spine (LS) magnetic resonance imaging (MRI) screening protocol consisting of a single 3D-T2 SPACE FS (3D-T2 Sampling Perfection with Application optimized Contrasts using different flip angle Evolution fat saturated) sequence relative to conventional LS MRI to exclude emergently treatable pathologies in this complex patient population. MATERIALS AND METHODS:LS MRI protocol including a sagittal 3D-T2 SPACE FS pulse sequence was added to the routine for ED patients presenting with acute atypical LBP over a 12-month period. Imaging findings were categorically scored on the 3D-T2 SPACE FS sequence and separately on the reference standard conventional LS MRI sequences. Patients' symptoms were obtained from review of the electronic medical record. Descriptive test statistics were performed. RESULTS:Of the 206 ED patients who obtained MRI for acute atypical LBP, 118 (43.3 ± 13.5 years of age; 61 female) were included. Specific pathologies detected on reference standard conventional MRI included disc herniation (n = 30), acute fracture (n = 3), synovial cyst (n = 3), epidural hematoma (n = 2), cerebrospinal fluid leak (n = 1), and leptomeningeal metastases (n = 1), and on multiple occasions these pathologies resulted in nerve root impingement (n = 36), severe spinal canal stenosis (n = 13), cord/conus compression (n = 2), and cord signal abnormality (n = 2). The 3D-T2 SPACE FS sequence was an effective screen for fracture (sensitivity [sens] = 100%, specificity [spec] = 100%), cord signal abnormality (sens = 100%, spec = 99%), and severe spinal canal stenosis (sens = 100%, spec = 96%), and identified cord compression not seen on reference standard. Motion artifact was not seen on the 3D-T2 SPACE FS but noted on 8.5% of conventional LS MRI. CONCLUSIONS:The 3D-T2 SPACE FS sequence MRI is a rapid, effective screen for emergently actionable pathologies that might be a cause of CES in ED patients presenting with acute atypical LBP. As this abbreviated, highly sensitive sequence requires a fraction of the acquisition time of conventional LS MRI, it has the potential of contributing to increased efficiencies in the radiology department and improved ED throughput.

journal_name

Acad Radiol

journal_title

Academic radiology

authors

Koontz NA,Wiggins RH 3rd,Mills MK,McLaughlin MS,Pigman EC,Anzai Y,Shah LM

doi

10.1016/j.acra.2017.02.011

subject

Has Abstract

pub_date

2017-08-01 00:00:00

pages

988-994

issue

8

eissn

1076-6332

issn

1878-4046

pii

S1076-6332(17)30125-3

journal_volume

24

pub_type

杂志文章
  • Clinical utility of quantitative imaging.

    abstract::Quantitative imaging (QI) is increasingly applied in modern radiology practice, assisting in the clinical assessment of many patients and providing a source of biomarkers for a spectrum of diseases. QI is commonly used to inform patient diagnosis or prognosis, determine the choice of therapy, or monitor therapy respon...

    journal_title:Academic radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.acra.2014.08.011

    authors: Rosenkrantz AB,Mendiratta-Lala M,Bartholmai BJ,Ganeshan D,Abramson RG,Burton KR,Yu JP,Scalzetti EM,Yankeelov TE,Subramaniam RM,Lenchik L

    更新日期:2015-01-01 00:00:00

  • CT-guided Drainage of Deep Pelvic Abscesses via a Percutaneous Presacral Space Approach: A Clinical Report and Review of the Literature.

    abstract:RATIONALE AND OBJECTIVES:Some deep pelvic abscesses are not accessible through anterior or lateral approaches because of the presence of organs and structures. The objective of this study was to assess the feasibility, safety, tolerability, and efficacy of a percutaneous presacral space approach by reviewing our clinic...

    journal_title:Academic radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.acra.2016.06.009

    authors: Peng T,Dong L,Zhu Z,Cui J,Li Q,Li X,Wu H,Wang C,Yang Z

    更新日期:2016-12-01 00:00:00

  • Comparison of image acquisition and radiologist interpretation times in a diagnostic mammography center.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to determine the acquisition and interpretation times of screen-film mammography and soft-copy digital mammography in a diagnostic mammography center. MATERIALS AND METHODS:The study was conducted in three phases for patients presenting for clinical diagnostic wor...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2010.04.018

    authors: Kuzmiak CM,Cole E,Zeng D,Kim E,Koomen M,Lee Y,Pavic D,Pisano ED

    更新日期:2010-09-01 00:00:00

  • Intraarterial biocompatibility of polyethylene terephthalate self-expandable stents implanted in porcine peripheral arteries.

    abstract:RATIONALE AND OBJECTIVES:We tested deployment feasibility and intraarterial biocompatibility of polyethylene terephthalate (PET) self-expandable vascular stents in a porcine peripheral artery model. METHODS:To assess the thrombogenicity and neointimal response to oversized PET self-expandable stents, we implanted 10 s...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/S1076-6332(05)80151-5

    authors: De Scheerder IK,Wilczek KV,Verbeken EV,Barios L,Piessens J,De Geest H

    更新日期:1995-02-01 00:00:00

  • Correlation Between Cardiac Computed Tomography and Histopathology for Evaluating Patients with Aortic Valve Disease.

    abstract:BACKGROUND:The use of cardiac computed tomography (cardiac CT) and the quantification of the Agatston score for the evaluation of calcium of the aortic valve (AVC) has increased in different clinical contexts for diagnostic and prognostic purposes. This study aims to evaluate the correlation between cardiac CT and hist...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2020.12.015

    authors: Saucedo-Orozco H,Torres IP,Vera SAC,Frausto AA,Godínez JAA,Guarner-Lans V,Rubio E,López MES

    更新日期:2021-01-14 00:00:00

  • Tracheobronchial metal stents: effects of covering a bronchial ostium in pigs.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to examine the effects of placing a metal stent across a bronchial orifice. MATERIALS AND METHODS:Nine pigs were used as test subjects, because the right upper lobe bronchus comes directly off the trachea in these animals. One of three types of metal stents was pl...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(99)80253-0

    authors: Bjarnason H,Cahill B,Kløw NE,Han YM,Urness M,Günther R,Gomes MR,Rosenberg MS,Dietz CA Jr,Hunter DW

    更新日期:1999-10-01 00:00:00

  • Coregistration of Preoperative MRI with Ex Vivo Mesorectal Pathology Specimens to Spatially Map Post-treatment Changes in Rectal Cancer Onto In Vivo Imaging: Preliminary Findings.

    abstract:RATIONALE AND OBJECTIVES:The objective of this study was to develop and quantitatively evaluate a radiology-pathology fusion method for spatially mapping tissue regions corresponding to different chemoradiation therapy-related effects from surgically excised whole-mount rectal cancer histopathology onto preoperative ma...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2017.12.006

    authors: Antunes J,Viswanath S,Brady JT,Crawshaw B,Ros P,Steele S,Delaney CP,Paspulati R,Willis J,Madabhushi A

    更新日期:2018-07-01 00:00:00

  • Quantification of hepatic steatosis: a comparison of computed tomography and magnetic resonance indices in candidates for living liver donation.

    abstract:RATIONALE AND OBJECTIVES:To evaluate, in a group of candidates for liver donation, the role of unenhanced computed tomography (CT) and magnetic resonance (MR) as noninvasive means to measure hepatic steatosis (HS). MATERIALS AND METHODS:Sixty-one consecutive candidates underwent CT and MR evaluation for liver donation...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2014.01.007

    authors: Maruzzelli L,Parr AJ,Miraglia R,Tuzzolino F,Luca A

    更新日期:2014-04-01 00:00:00

  • Glioma recurrence versus radiation necrosis? A pilot comparison of arterial spin-labeled, dynamic susceptibility contrast enhanced MRI, and FDG-PET imaging.

    abstract:RATIONALE AND OBJECTIVES:Distinguishing recurrent glial tumor from radiation necrosis can be challenging. The purpose of this pilot study was to preliminarily compare unenhanced arterial spin-labeled (ASL) imaging, dynamic susceptibility contrast-enhanced cerebral blood volume (DSCE-CBV) magnetic resonance imaging, and...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2009.10.024

    authors: Ozsunar Y,Mullins ME,Kwong K,Hochberg FH,Ament C,Schaefer PW,Gonzalez RG,Lev MH

    更新日期:2010-03-01 00:00:00

  • Chest radiology case exchange program: a paradigm for resident teaching and independent resident learning.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to test the effectiveness of resident-prepared, independent learning cases in teaching residents chest radiology. MATERIALS AND METHODS:Three 2nd-year residents (one each from the University of Wisconsin, the Oregon Health Sciences University, and the University o...

    journal_title:Academic radiology

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1016/s1076-6332(99)80059-2

    authors: Collins J,Blankenbaker DG,Albanese MA,Stack SP,Heiserman KK,Primack SL,Kazerooni EA

    更新日期:1999-01-01 00:00:00

  • Helical multidetector row quantitative computed tomography (QCT) precision.

    abstract:RATIONALE AND OBJECTIVES:The impact of varying image acquisition parameters on the precision of measurements using quantitative computed tomography is currently based on studies performed before the advent of helical image acquisition and multidetector-row scanners. The aim of this study was to evaluate helical multide...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2008.08.007

    authors: Bligh M,Bidaut L,White RA,Murphy WA Jr,Stevens DM,Cody DD

    更新日期:2009-02-01 00:00:00

  • Identification of noncalcified plaque in young persons with diabetes: an opportunity for early primary prevention of coronary artery disease identified with low-dose coronary computed tomographic angiography.

    abstract:PURPOSE:Coronary computed tomographic angiography (CTA) is a valuable tool for assessing coronary artery disease (CAD). Although statin use is widely recommended for persons with diabetes older than age 40, little is known about the presence and severity of CAD in younger patients with diabetes mellitus (DM). We evalua...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2012.03.013

    authors: Madaj PM,Budoff MJ,Li D,Tayek JA,Karlsberg RP,Karpman HL

    更新日期:2012-07-01 00:00:00

  • Diagnosis of Lymphangiomatosis: A Study Based on CT Lymphangiography.

    abstract:RATIONALE AND OBJECTIVES:Lymphangiomatosis is a rare disease characterized by the widespread presence of lymphangiomas in any part of the body. In previous studies, lymphatic vessel abnormalities in lymphangiomatosis have only rarely been mentioned. The objective of this paper is to discuss the imaging features of lymp...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2019.03.024

    authors: Jin D,Sun X,Shen W,Zhao Q,Wang R

    更新日期:2020-02-01 00:00:00

  • Mild traumatic brain injury: tissue texture analysis correlated to neuropsychological and DTI findings.

    abstract:RATIONALE AND OBJECTIVES:The aim of this study was to evaluate whether texture analysis (TA) can detect subtle changes in cerebral tissue caused by mild traumatic brain injury (MTBI) and to determine whether these changes correlate with neuropsychological and diffusion tensor imaging (DTI) findings. MATERIALS AND METH...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2010.04.009

    authors: Holli KK,Wäljas M,Harrison L,Liimatainen S,Luukkaala T,Ryymin P,Eskola H,Soimakallio S,Ohman J,Dastidar P

    更新日期:2010-09-01 00:00:00

  • Sampling variability of nonparametric estimates of the areas under receiver operating characteristic curves: an update.

    abstract:RATIONALE AND OBJECTIVES:Several methods have been proposed for calculating the variances and covariances of nonparametric estimates of the area under receiver operating characteristic curves (AUC). The authors provide an explanation of the relationships between them and illustrate the factors that determine sampling v...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(97)80161-4

    authors: Hanley JA,Hajian-Tilaki KO

    更新日期:1997-01-01 00:00:00

  • Comparison of three methods for estimating the standard error of the area under the curve in ROC analysis of quantitative data.

    abstract:RATIONALE AND OBJECTIVES:Several methods have been proposed for estimating the standard error (SE) of the area under the curve (AUC) in receiver operating characteristic analysis. The authors examined the validity of three methods--the LABROC procedure, exponential approximation, and the method of DeLong et al (purely ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(03)80561-5

    authors: Hajian-Tilaki KO,Hanley JA

    更新日期:2002-11-01 00:00:00

  • Image artifacts on prostate diffusion-weighted magnetic resonance imaging: trade-offs at 1.5 Tesla and 3.0 Tesla.

    abstract:RATIONALE AND OBJECTIVES:To identify the presence and extent of artifacts in prostate diffusion-weighted magnetic resonance imaging (DW-MRI) and discuss tradeoffs between imaging at 1.5 T (1.5 T) and 3.0 T (3.0 T). In addition, we aim to provide quantitative estimates of signal-to-noise ratios (SNRs) at both field stre...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2013.04.005

    authors: Mazaheri Y,Vargas HA,Nyman G,Akin O,Hricak H

    更新日期:2013-08-01 00:00:00

  • Stereotactic and sonographic large-core biopsy of nonpalpable breast lesions: results of the Radiologic Diagnostic Oncology Group V study.

    abstract:RATIONALE AND OBJECTIVES:To determine the diagnostic accuracy of stereotactically and sonographically guided core biopsy (CB) for the diagnosis of nonpalpable breast lesions. MATERIALS AND METHODS:Twenty-two institutions enrolled 2,403 women who underwent imaging-guided fine needle aspiration followed by imaging-guide...

    journal_title:Academic radiology

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1016/s1076-6332(03)00510-5

    authors: Fajardo LL,Pisano ED,Caudry DJ,Gatsonis CA,Berg WA,Connolly J,Schnitt S,Page DL,McNeil BJ,Radiologist Investigators of the Radiologic Diagnostic Oncology Group V.

    更新日期:2004-03-01 00:00:00

  • Mesoscopic fluorescence tomography of a photosensitizer (HPPH) 3D biodistribution in skin cancer.

    abstract:RATIONALE AND OBJECTIVES:Photodynamic therapy (PDT) is a promising strategy for treating cancer. PDT involves three components: a photosensitizer (PS) drug, a specific wavelength of drug-activating light, and oxygen. A challenge in PDT is the unknown biodistribution of the PS in the target tissue. In this preliminary s...

    journal_title:Academic radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.acra.2013.11.009

    authors: Ozturk MS,Rohrbach D,Sunar U,Intes X

    更新日期:2014-02-01 00:00:00

  • Experimental correlation between T2* and ultimate compressive strength in lumbar porcine vertebrae.

    abstract:RATIONALE AND OBJECTIVES:The authors used magnetic resonance (MR) imaging to investigate the correlation between T2* measurements of trabecular bone and the ultimate compressive strength of lumbar porcine vertebrae. METHODS:Five pigs that weighted 25-32 kg were sacrificed and imaged with a 1.5-T MR system. T2* of the ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(97)80050-5

    authors: Brismar TB,Hindmarsh T,Ringertz H

    更新日期:1997-06-01 00:00:00

  • Optimal ECG trigger point in electron-beam CT studies: three methods for minimizing motion artifacts.

    abstract:RATIONALE AND OBJECTIVES:The authors hypothesized that electrocardiographic triggering near end systole could minimize motion artifacts in electron-beam computed tomography (CT) of the coronary artery. MATERIALS AND METHODS:The study included 2,660 patients who underwent coronary artery calcium scanning with electron-...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/S1076-6332(03)80722-5

    authors: Mao S,Budoff MJ,Bin L,Liu SC

    更新日期:2001-11-01 00:00:00

  • Determination of unknown high-grade atherosclerotic lesions by whole-body cardiovascular imaging: assessment of patients with symptomatic atherosclerotic disease of peripheral arteries.

    abstract:RATIONALE AND OBJECTIVES:The long-term prospects for patients with peripheral-arterial-occlusive disease (PAOD) must be considered in the context of coexistent generalized atherosclerosis. We sought to determine the added clinical information of noninvasive magnetic resonance imaging (MRI) for detecting asymptomatic at...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2009.08.008

    authors: Fenchel M,Scheule AM,Kramer U,Bretschneider C,Klumpp B,Seeger A,Rittig K,Claussen CD,Miller S

    更新日期:2010-02-01 00:00:00

  • Dual-source CT angiography in aortic stent grafting: An in vitro aorta phantom study of image noise and radiation dose.

    abstract:RATIONALE AND OBJECTIVES:The aim of the study was to investigate the optimal protocols of dual-source computed tomography (CT) angiography in aortic stent grafting in terms of image noise and radiation dose, based on an in vitro phantom study. MATERIALS AND METHODS:A series of helical CT cans were performed on a human...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2010.03.004

    authors: Sun Z,Ng C

    更新日期:2010-07-01 00:00:00

  • Automatic determination of differential coronary artery motion minima for cardiac computed tomography optimal phase selection.

    abstract:RATIONALE AND OBJECTIVES:Selecting the optimal phase for coronary artery evaluation can be challenging, especially at higher heart rates, given that the optimal phase may differ for each of the coronary arteries. This study aimed to evaluate a novel vessel-specific algorithm which automatically outputs the minimum moti...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2015.01.013

    authors: Lessick J,Klass O,Wuchenauer S,Walker MJ,Schmitt H,Peters J,Weese J,Brunner H,Vembar M,Grass M,Aronson D,Hoffmann MH

    更新日期:2015-06-01 00:00:00

  • Reproducibility and repeatability of volumetric measurements for olfactory bulb volumetry: which method is appropriate? An update using 3 Tesla MRI.

    abstract:RATIONALE AND OBJECTIVES:The aim of this study was to compare different sequences for olfactory bulb volumetry using 3-T magnetic resonance imaging, evaluating reproducibility, repeatability, and systematic biases. MATERIALS AND METHODS:Twenty-two volunteers underwent 3-T magnetic resonance imaging of the frontal skul...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2011.02.018

    authors: Burmeister HP,Baltzer PA,Möslein C,Bitter T,Gudziol H,Dietzel M,Guntinas-Lichius O,Kaiser WA

    更新日期:2011-07-01 00:00:00

  • Reinventing the apprenticeship: the hot seat in the digital era.

    abstract:RATIONALE AND OBJECTIVES:Describe new interactive digital teaching methods for medical student education in radiology and evaluate student responses. MATERIALS AND METHODS:Third- and fourth-year medical students on radiology clerkship were taught using either film-based "hot seat" format, digital "hot seat," or didact...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2004.07.017

    authors: Su TJ,Shaffer K

    更新日期:2004-11-01 00:00:00

  • Emotional Wellness of Current Musculoskeletal Radiology Fellows.

    abstract:RATIONALE AND OBJECTIVES:Burnout is a psychological syndrome composed of emotional exhaustion, depersonalization, and sense of lack of personal accomplishment, as a result of prolonged occupational stress. The purpose of our study was to determine the prevalence of burnout among current musculoskeletal radiology fellow...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2016.12.024

    authors: Porrino J,Mulcahy MJ,Mulcahy H,Relyea-Chew A,Chew FS

    更新日期:2017-06-01 00:00:00

  • Results of the 1993 survey of the American Association of Academic Chief Residents in Radiology.

    abstract:RATIONALE AND OBJECTIVES:A survey of chief residents of academic radiology programs is conducted annually on behalf of the American Association of Academic Chief Residents in Radiology (A3CR2). Data are obtained to improve the training of diagnostic radiology residents and to increase the understanding of radiologists ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(05)80835-9

    authors: Oser AB,Baker SM,Wilson AJ,Evens RG

    更新日期:1994-10-01 00:00:00

  • Lung nodule CAD software as a second reader: a multicenter study.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this multicenter, multireader study was to evaluate the performance of computed tomography (CT) lung nodule computer-aided detection (CAD) software as a second reader. METHODS AND MATERIALS:The study involved 109 patients from four sites. The data were collected from a variety o...

    journal_title:Academic radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1016/j.acra.2007.09.027

    authors: White CS,Pugatch R,Koonce T,Rust SW,Dharaiya E

    更新日期:2008-03-01 00:00:00

  • Assessment of intraaxial and extraaxial brain lesions with digitized computed tomographic images versus film: ROC analysis.

    abstract:RATIONALE AND OBJECTIVES:The authors evaluated the diagnostic accuracy of viewing computed tomographic (CT) scans as film versus soft-copy images at a workstation. METHODS:Receiver operating characteristic analysis of the interpretation of 202 CT scans (103 were normal, 99 were abnormal) by five neuroradiologists was ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(97)80004-9

    authors: el-Saden SM,Hademenos GJ,Zhu W,Sayre JW,Glenn B,Steidler J,Kode L,King B,Quinones D,Valentino DJ,Bentson JR

    更新日期:1997-02-01 00:00:00