MAGAT gel and EBT2 film-based dosimetry for evaluating source plugging-based treatment plan in Gamma Knife stereotactic radiosurgery.

Abstract:

:This work illustrates a procedure to assess the overall accuracy associated with Gamma Knife treatment planning using plugging. The main role of source plugging or blocking is to create dose falloff in the junction between a target and a critical structure. We report the use of MAGAT gel dosimeter for verification of an experimental treatment plan based on plugging. The polymer gel contained in a head-sized glass container simulated all major aspects of the treatment process of Gamma Knife radiosurgery. The 3D dose distribution recorded in the gel dosimeter was read using a 1.5T MRI scanner. Scanning protocol was: CPMG pulse sequence with 8 equidistant echoes, TR = 7 s, echo step = 14 ms, pixel size = 0.5mm × 0.5mm, and slice thickness of 2 mm. Using a calibration relationship between absorbed dose and spin-spin relaxation rate (R2), we converted R2 images to dose images. Volumetric dose comparison between treatment planning system (TPS) and gel measurement was accomplished using an in-house MATLAB-based program. The isodose overlay of the measured and computed dose distribution on axial planes was in close agreement. Gamma index analysis of 3D data showed more than 94% voxel pass rate for different tolerance criteria of 3%/2 mm, 3%/1 mm and 2%/2 mm. Film dosimetry with GAFCHROMIC EBT 2 film was also performed to compare the results with the calculated TPS dose. Gamma index analysis of film measurement for the same tolerance criteria used for gel measurement evaluation showed more than 95% voxel pass rate. Verification of gamma plan calculated dose on account of shield is not part of acceptance testing of Leksell Gamma Knife (LGK). Through this study we accomplished a volumetric comparison of dose distributions measured with a polymer gel dosimeter and Leksell GammaPlan (LGP) calculations for plans using plugging. We propose gel dosimeter as a quality assurance (QA) tool for verification of plug-based planning.

journal_name

J Appl Clin Med Phys

authors

Natanasabapathi G,Subbiah V,Kale SS,Rath GK,Senthilkumaran S,Thulkar S,Subramani V,Laviraj MA,Bisht RK,Mahapatra AK

doi

10.1120/jacmp.v13i6.3877

subject

Has Abstract

pub_date

2012-11-08 00:00:00

pages

3877

issue

6

issn

1526-9914

journal_volume

13

pub_type

杂志文章
  • Development and validation of a comprehensive patient-specific quality assurance program for a novel stereotactic radiation delivery system for breast lesions.

    abstract:PURPOSE:The GammaPod is a dedicated prone breast stereotactic radiosurgery (SRS) machine composed of 25 cobalt-60 sources which rotate around the breast to create highly conformal dose distributions for boosts, partial-breast irradiation, or neo-adjuvant SRS. We describe the development and validation of a patient-spec...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12778

    authors: Becker SJ,Niu Y,Mutaf Y,Chen S,Poirier Y,Nichols EM,Yi B

    更新日期:2019-12-01 00:00:00

  • Effectiveness of a novel gas-release endorectal balloon in the removal of rectal gas for prostate proton radiation therapy.

    abstract::Endorectal balloons (ERBs) are routinely used in prostate proton radiation therapy to immobilize the prostate and spare the rectal wall. Rectal gas can distend the rectum and displace the prostate even in the presence of ERBs. The purpose of this work was to quantify the effects an ERB with a passive gas release condu...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i5.3945

    authors: Wootton LS,Kudchadker RJ,Beddar AS,Lee AK

    更新日期:2012-09-06 00:00:00

  • Using C-Arm X-ray images from marker insertion to confirm the gold fiducial marker identification in an MRI-only prostate radiotherapy workflow.

    abstract::Prostate cancer radiotherapy workflows, solely based on magnetic resonance imaging (MRI), are now in clinical use. In these workflows, intraprostatic gold fiducial markers (GFM) show similar signal behavior as calcifications and bleeding in T2-weighted MRI-images. Accurate GFM identification in MRI-only radiotherapy w...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12478

    authors: Gustafsson C,Persson E,Gunnlaugsson A,Olsson LE

    更新日期:2018-11-01 00:00:00

  • An open-source software for monitoring intrafraction motion during external beam radiation therapy based on superimposition of contours of projected ROIs on cine-MV images.

    abstract:PURPOSE:To present an open-source software (https://github.com/CHUSRadOncPhys/FluoMV) for monitoring intrafraction motion that is based on the visualization of superimposed contours of projected region-of-interests from DICOM RTSTRUCT files on cine-MV images acquired and displayed in real-time during radiation therapy ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12940

    authors: Lessard R,Tremblay NM,Plourde MÉ,Guillot M

    更新日期:2020-08-01 00:00:00

  • Electrocardiogram-gated coronary CT angiography dose estimates using ImPACT.

    abstract::The primary study objective was to assess radiation doses using a modified form of the Imaging Performance Assessment of Computed Tomography (CT) scanner (ImPACT) patient dosimetry for cardiac applications on an Aquilion ONE ViSION Edition scanner, including the Ca score, target computed tomography angiography (CTA), ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i4.6218

    authors: Kobayashi M,Asada Y,Matsubara K,Suzuki S,Koshida K,Matsunaga Y,Haba T,Kawaguchi A,Toyama H,Kato R

    更新日期:2016-07-08 00:00:00

  • Verification of Varian Enhanced Dynamic Wedge implementation in masterplan treatment planning system.

    abstract::This paper investigates the accuracy of the two available calculation algorithms of the Oncentra MasterPlan three-dimensional treatment planning system (TPS)-- the pencil beam method and collapsed-cone convolution--in modeling the Varian enhanced dynamic wedge (EDW). Measurements were carried out for a dual high energ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v10i2.2867

    authors: Pasquino M,Borca VC,Tofani S,Ozzello F

    更新日期:2009-04-22 00:00:00

  • Automating checks of plan check automation.

    abstract::While a few physicists have designed new plan check automation solutions for their clinics, fewer, if any, managed to adapt existing solutions. As complex and varied as the systems they check, these programs must gain the full confidence of those who would run them on countless patient plans. The present automation ef...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i4.4889

    authors: Halabi T,Lu HM

    更新日期:2014-07-08 00:00:00

  • Production of neutrons in laminated barriers of radiotherapy rooms: comparison between the analytical methodology and Monte Carlo simulations.

    abstract::The necessity to build or adapt radiotherapy rooms in reduced areas leads to the search for unconventional solutions for shielding projects. In most cases, adding metals to the primary barriers is the best alternative to shield rooms properly. However, when photons with energies equal or higher than 10 MV interact wit...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i6.5035

    authors: Rezende GF,Da Rosa LA,Facure A

    更新日期:2014-11-08 00:00:00

  • Stereotactic IMRT for prostate cancer: setup accuracy of a new stereotactic body localization system.

    abstract::The purpose of this work is to prospectively assess the setup accuracy that can be achieved with a stereotactic body localizer (SBL) in immobilizing patients for stereotactic intensity-modulated radiotherapy (IMRT) for prostate cancer. By quantifying this important factor and target mobility in the SBL, we expect to p...

    journal_title:Journal of applied clinical medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1120/jacmp.v5i2.1947

    authors: Wang L,Jacob R,Chen L,Ma C,Movsas B,Feigenberg S,Konski A

    更新日期:2004-04-01 00:00:00

  • Commissioning and validation of BrainLAB cones for 6X FFF and 10X FFF beams on a Varian TrueBeam STx.

    abstract::Small field dosimetry is a challenging task. The difficulties of small field measurements, particularly stereotactic field size measurements, are highlighted by the large interinstitution variability that can be observed for circular cone collimator commissioning measurements. We believe the best way to improve the co...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i6.4493

    authors: Wiant DB,Terrell JA,Maurer JM,Yount CL,Sintay BJ

    更新日期:2013-11-04 00:00:00

  • Deriving detector-specific correction factors for rectangular small fields using a scintillator detector.

    abstract::The goal of this study was to investigate small field output factors (OFs) for flat-tening filter-free (FFF) beams on a dedicated stereotactic linear accelerator-based system. From this data, the collimator exchange effect was quantified, and detector-specific correction factors were generated. Output factors for 16 j...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i6.6433

    authors: Qin Y,Zhong H,Wen N,Snyder K,Huang Y,Chetty IJ

    更新日期:2016-11-08 00:00:00

  • Accurate method for evaluating the duration of the entire radiotherapy process.

    abstract:BACKGROUND AND PURPOSE:Along with the increasing demand for high-quality radiotherapy and the growing number of high-precision radiotherapy devices, precise radiotherapy workflow management and accurate time evaluation of the entire radiotherapy process are crucial to providing appropriate, timely treatment for cancer ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12959

    authors: Guo C,Huang P,Li Y,Dai J

    更新日期:2020-09-01 00:00:00

  • Commissioning of Varian ring & tandem HDR applicators: reproducibility and interobserver variability of dwell position offsets.

    abstract::Studies have shown that source dwells within Varian's HDR CT/MR compatible ring applicators can deviate from intended positions by several millimeters. Quantifying this offset is an important part of commissioning. The aims of this study were to: 1) determine the reproducibility of the offset, 2) study the interobserv...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v12i4.3447

    authors: McMahon R,Zhuang T,Steffey BA,Song H,Craciunescu OI

    更新日期:2011-11-15 00:00:00

  • Dose calculation for hypofractionated volumetric-modulated arc therapy: approximating continuous arc delivery and tongue-and-groove modeling.

    abstract::Hypofractionated treatments generally increase the complexity of a treatment plan due to the more stringent constraints of normal tissues and target coverage. As a result, treatment plans contain more modulated MLC motions that may require extra efforts for accurate dose calculation. This study explores methods to min...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i2.4989

    authors: Yang J,Tang G,Zhang P,Hunt M,Lim SB,LoSasso T,Mageras G

    更新日期:2016-03-08 00:00:00

  • Dosimetric comparison of preoperative single-fraction partial breast radiotherapy techniques: 3D CRT, noncoplanar IMRT, coplanar IMRT, and VMAT.

    abstract::The purpose of this study was to compare dosimetric parameters of treatment plans among four techniques for preoperative single-fraction partial breast radiotherapy in order to select an optimal treatment technique. The techniques evaluated were noncoplanar 3D conformal radiation therapy (3D CRT), noncoplanar intensit...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i1.5126

    authors: Yoo S,Blitzblau R,Yin FF,Horton JK

    更新日期:2015-01-08 00:00:00

  • Hepatic encephalopathy: a neurochemical, neuroanatomical, and neuropsychological study.

    abstract::Hepatic encephalopathy (HE) is normally diagnosed by neuropsychological (NP) tests, which are not very specific and do not reveal the underlying pathology. Magnetic resonance imaging (MRI) and spectroscopy (MRS) of the brain offer alternative and possibly more specific markers for HE. These methods were applied in con...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v7i1.2151

    authors: Binesh N,Huda A,Thomas MA,Wyckoff N,Bugbee M,Han S,Rasgon N,Davanzo P,Sayre J,Guze B,Martin P,Fawzy F

    更新日期:2006-01-01 00:00:00

  • Evaluation of deep learning-based auto-segmentation algorithms for delineating clinical target volume and organs at risk involving data for 125 cervical cancer patients.

    abstract:OBJECTIVE:To evaluate the accuracy of a deep learning-based auto-segmentation mode to that of manual contouring by one medical resident, where both entities tried to mimic the delineation "habits" of the same clinical senior physician. METHODS:This study included 125 cervical cancer patients whose clinical target volu...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13097

    authors: Wang Z,Chang Y,Peng Z,Lv Y,Shi W,Wang F,Pei X,Xu XG

    更新日期:2020-12-01 00:00:00

  • Assessment of error in the MV radiation isocenter position calculated with the Elekta XVI software.

    abstract::The assessment of the coincidence of imaging and radiation isocenters is an important task of regular quality assurance of medical linear accelerators (linacs) as recommended in national and international quality assurance guidelines. A previously reported investigation of the accuracy of the Elekta XVI software to lo...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12861

    authors: Chojnowski JM,Warr GB,Sykes JR,Thwaites DI

    更新日期:2020-05-01 00:00:00

  • Can Hyperpolarized Helium MRI add to radiation planning and follow-up in lung cancer?

    abstract::Locally advanced non-small-cell lung cancer (NSCLC) is a common disease with a low overall survival even with aggressive treatments. Standard imaging (CT and PET/CT) provide no information about normal lung function. We therefore, sought to pilot HeMRI in patients with non-small-cell lung cancer before and after defin...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v12i2.3357

    authors: Allen AM,Albert M,Caglar HB,Zygmanski P,Soto R,Killoran J,Sun Y

    更新日期:2011-01-31 00:00:00

  • A computational tool for the efficient analysis of dose-volume histograms from radiation therapy treatment plans.

    abstract::A Histogram Analysis in Radiation Therapy (HART) program was primarily developed to increase the efficiency and accuracy of dose-volume histogram (DVH) analysis of large quantities of patient data in radiation therapy research. The program was written in MATLAB to analyze patient plans exported from the treatment plan...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:

    authors: Pyakuryal A,Myint WK,Gopalakrishnan M,Jang S,Logemann JA,Mittal BB

    更新日期:2010-01-28 00:00:00

  • Modeling Elekta VersaHD using the Varian Eclipse treatment planning system for photon beams: A single-institution experience.

    abstract::The aim of this study was to report a single-institution experience and commissioning data for Elekta VersaHD linear accelerators (LINACs) for photon beams in the Eclipse treatment planning system (TPS). Two VersaHD LINACs equipped with 160-leaf collimators were commissioned. For each energy, the percent-depth-dose (P...

    journal_title:Journal of applied clinical medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1002/acm2.12709

    authors: Zhang Y,Le AH,Tian Z,Iqbal Z,Chiu T,Gu X,Pugachev A,Reynolds R,Park YK,Lin MH,Stojadinovic S

    更新日期:2019-10-01 00:00:00

  • A novel method for radiotherapy patient identification using surface imaging.

    abstract::Performing a procedure on the wrong patient or site is one of the greatest errors that can occur in medicine. The addition of automation has been shown to reduce errors in many processes. In this work we explore the use of an automated patient identification process using optical surface imaging for radiotherapy treat...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i2.6066

    authors: Wiant DB,Verchick Q,Gates P,Vanderstraeten CL,Maurer JM,Hayes TL,Liu H,Sintay BJ

    更新日期:2016-03-08 00:00:00

  • In vivo dosimetry and shielding disk alignment verification by EBT3 GAFCHROMIC film in breast IOERT treatment.

    abstract::Intraoperative electron radiation therapy (IOERT) cannot usually benefit, as conventional external radiotherapy, from software systems of treatment planning based on computed tomography and from common dose verify procedures. For this reason, in vivo film dosimetry (IVFD) proves to be an effective methodology to evalu...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i1.5065

    authors: Severgnini M,de Denaro M,Bortul M,Vidali C,Beorchia A

    更新日期:2014-01-08 00:00:00

  • A study on image quality provided by a kilovoltage cone-beam computed tomography.

    abstract::The image-guided radiotherapy technique (IGRT) makes use of imaging devices to verify the positions of the target volume and organs at risk during the treatment sessions. In this work we evaluate the image quality provided by an imaging system based on a kilovoltage cone-beam CT, and explore its ability to perform IGR...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i1.3888

    authors: Garayoa J,Castro P

    更新日期:2013-01-07 00:00:00

  • Effect of skull shape approximations in Gamma Knife dose calculations.

    abstract::Doses in Leksell GammaPlan (Elekta, Stockholm, Sweden) are calculated for each shot by summing the contribution from the 201 radiation beams emitted by the Gamma Knife (Elekta), weighted for attenuation in the tissue traversed. The patient's head is modeled based on 24 skull measurements, from which the depth to the c...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v8i3.2377

    authors: Berndt A,Beck J

    更新日期:2007-07-17 00:00:00

  • Evaluation of cumulative dose for cone-beam computed tomography (CBCT) scans within phantoms made from different compositions using Monte Carlo simulations.

    abstract::Measurement of cumulative dose ƒ(0,150) with a small ionization chamber within standard polymethyl methacrylate (PMMA) CT head and body phantoms, 150 mm in length, is a possible practical method for cone-beam computed tomography (CBCT) dosimetry. This differs from evaluating cumulative dose under scatter equilibrium c...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i6.5793

    authors: Abuhaimed A,Martin CJ,Sankaralingam M,Oomen K,Gentle DJ

    更新日期:2015-11-08 00:00:00

  • A protocol to extend the longitudinal coverage of on-board cone-beam CT.

    abstract::The longitudinal coverage of a LINAC-mounted CBCT scan is limited to the corresponding dimensional limits of its flat panel detector, which is often shorter than the length of the treatment field. These limits become apparent when fields are designed to encompass wide regions, as when providing nodal coverage. Therefo...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i4.3796

    authors: Zheng D,Lu J,Jefferson A,Zhang C,Wu J,Sleeman W,Weiss E,Dogan N,Song S,Williamson J

    更新日期:2012-07-05 00:00:00

  • Estimating and reducing dose received by cardiac devices for patients undergoing radiotherapy.

    abstract::The objectives of this project are to quantify the dose reduction effect provided by a lead shield for patients with cardiac implantable electronic devices (CIED) during a clinically realistic radiation treatment on phantom and to provide a simple model of dose estimation to predict dose received by CIED in a wide ran...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i6.5317

    authors: Bourgouin A,Varfalvy N,Archambault L

    更新日期:2015-11-08 00:00:00

  • Improving a scissor-action couch for conformal arc radiotherapy and radiosurgery.

    abstract::We have developed a method to improve the setup accuracy of a Varian Clinac 6/100 couch for delivering conformal arc therapy using a tertiary micro multileaf collimator (MLC) system. Several immobilization devices have been developed to improve the mechanical stability and isocenter alignment of the couch: turn-knob h...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v5i3.2026

    authors: Li K,Yu CX,Ma L

    更新日期:2004-07-01 00:00:00

  • Retrospective analysis of linear accelerator output constancy checks using process control techniques.

    abstract::Shewhart control charts have previously been suggested as a process control tool for use in routine linear accelerator (linac) output verifications. However, a comprehensive approach to process control has not been investigated for linac output verifications. The purpose of this work is to investigate a comprehensive ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i1.4032

    authors: Sanghangthum T,Suriyapee S,Srisatit S,Pawlicki T

    更新日期:2013-01-07 00:00:00