Hepatic encephalopathy: a neurochemical, neuroanatomical, and neuropsychological study.

Abstract:

:Hepatic encephalopathy (HE) is normally diagnosed by neuropsychological (NP) tests, which are not very specific and do not reveal the underlying pathology. Magnetic resonance imaging (MRI) and spectroscopy (MRS) of the brain offer alternative and possibly more specific markers for HE. These methods were applied in conjunction with NP testing in order to determine their usefulness in the identification of HE and to understand the pathogenesis of HE more clearly. MR imaging and spectroscopy examinations, in addition to a battery of 15 NP tests, were administered to investigate 31 patients awaiting liver transplantation and 23 healthy controls. MR image intensities from the globus pallidus region were calculated and normalized to those of the thalamus. Absolute concentrations and ratios with respect to creatine (Cr) of several metabolites were computed from MR spectra. The MR data were correlated with the results of NP tests. The patients showed impairment in NP tests of attention and visuospatial and verbal fluency. In T1-weighted MRI, the relative intensity of the globus pallidus with respect to that of the thalamus region was significantly elevated in patients and correlated(negatively) with three NP tests (Hooper, FAS, and Trails B). The absolute concentrations of myo-inositol (mI) and choline (Ch) were significantly reduced in three brain regions. In addition, the absolute concentrations of glutamine (Gln) and combined glutamate and glutamine (Glx) were increased in all three locations, with Gln increase being significant in all areas while that of Glx only in the occipital white matter. In summary, this study partially confirms a hypothesized mechanism of HE pathogenesis, an increased synthesis of glutamine by brain glutamate in astrocytes due to excessive blood ammonia, followed by a compensatory loss of myo-inositol to maintain astrocyte volume homeostasis. It also indicates that the hyperintensity observed in globus pallidus could be used as complementary to the NP test scores in evaluating the mental health of HE patients.

journal_name

J Appl Clin Med Phys

authors

Binesh N,Huda A,Thomas MA,Wyckoff N,Bugbee M,Han S,Rasgon N,Davanzo P,Sayre J,Guze B,Martin P,Fawzy F

doi

10.1120/jacmp.v7i1.2151

keywords:

subject

Has Abstract

pub_date

2006-01-01 00:00:00

pages

86-96

issue

1

issn

1526-9914

journal_volume

7

pub_type

杂志文章
  • Comparison of two algorithms for determining beam weights and wedge filters.

    abstract::This article compares two algorithms for determining beam weights and wedge filters for conformal treatment planning. One algorithm, which is based on dose-gradient analysis, provides analytic formulas for determining beam weights, wedge angles, and collimator angles (i.e., wedge orientations) so that the dose distrib...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v3i3.2562

    authors: Dai J,Zhu Y

    更新日期:2002-07-01 00:00:00

  • Investigation of error detection capabilities of phantom, EPID and MLC log file based IMRT QA methods.

    abstract::A patient specific quality assurance (QA) should detect errors that originate anywhere in the treatment planning process. However, the increasing complexity of treatment plans has increased the need for improvements in the accuracy of the patient specific pretreatment verification process. This has led to the utilizat...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12114

    authors: Defoor DL,Stathakis S,Roring JE,Kirby NA,Mavroidis P,Obeidat M,Papanikolaou N

    更新日期:2017-07-01 00:00:00

  • The development of a 4D treatment planning methodology to simulate the tracking of central lung tumors in an MRI-linac.

    abstract:PURPOSE:Targeting and tracking of central lung tumors may be feasible on the Elekta MRI-linac (MRL) due to the soft-tissue visualization capabilities of MRI. The purpose of this work is to develop a novel treatment planning methodology to simulate tracking of central lung tumors with the MRL and to quantify the benefit...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12233

    authors: Al-Ward SM,Kim A,McCann C,Ruschin M,Cheung P,Sahgal A,Keller BM

    更新日期:2018-01-01 00:00:00

  • Analysis of esophageal-sparing treatment plans for patients with high-grade esophagitis.

    abstract::We retrospectively generated IMRT plans for 14 NSCLC patients who had experienced grade 2 or 3 esophagitis (CTCAE version 3.0). We generated 11-beam and reduced esophagus dose plan types to compare changes in the volume and length of esophagus receiving doses of 50, 55, 60, 65, and 70 Gy. Changes in planning target vo...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i4.4248

    authors: Niedzielski J,Bluett JB,Williamson RT,Liao Z,Gomez DR,Court LE

    更新日期:2013-07-08 00:00:00

  • SWIMRT: a graphical user interface using sliding window algorithm to construct a fluence map machine file.

    abstract::A custom-made computer program, SWIMRT, to construct "multileaf collimator (MLC) machine" file for intensity-modulated radiotherapy (IMRT) fluence maps was developed using MATLAB and the sliding window algorithm. The user can either import a fluence map with a graphical file format created by an external treatment-pla...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v7i2.2231

    authors: Chow JC,Grigorov GN,Yazdani N

    更新日期:2006-05-25 00:00:00

  • Dosimetric comparison of preoperative single-fraction partial breast radiotherapy techniques: 3D CRT, noncoplanar IMRT, coplanar IMRT, and VMAT.

    abstract::The purpose of this study was to compare dosimetric parameters of treatment plans among four techniques for preoperative single-fraction partial breast radiotherapy in order to select an optimal treatment technique. The techniques evaluated were noncoplanar 3D conformal radiation therapy (3D CRT), noncoplanar intensit...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i1.5126

    authors: Yoo S,Blitzblau R,Yin FF,Horton JK

    更新日期:2015-01-08 00:00:00

  • Radiation therapy plan checks in a paperless clinic.

    abstract::Traditional quality assurance checks of a patient's radiation therapy plan involve printing out treatment parameters from the treatment planning system and the "record and verify" (R&V) system and visually checking the information for one-to-one correspondence. In a paperless environment, one can automate this process...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v10i1.2905

    authors: Siochi RA,Pennington EC,Waldron TJ,Bayouth JE

    更新日期:2009-01-27 00:00:00

  • Introduction to passive electron intensity modulation.

    abstract::This work introduces a new technology for electron intensity modulation, which uses small area island blocks within the collimating aperture and small area island apertures in the collimating insert. Due to multiple Coulomb scattering, electrons contribute dose under island blocks and lateral to island apertures. By s...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12163

    authors: Hogstrom KR,Carver RL,Chambers EL,Erhart K

    更新日期:2017-11-01 00:00:00

  • Evaluation of three APBI techniques under NSABP B-39 guidelines.

    abstract::This work compares two accelerated partial breast irradiation modalities, MammoSite brachytherapy and three dimensional conformal radiotherapy (3D-CRT), to a new method, SAVI brachytherapy, following NSABP B-39 guidelines. A total of 21 patients treated at UC San Diego with the SAVI device were evaluated in this compa...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v11i1.3021

    authors: Scanderbeg D,Yashar C,White G,Rice R,Pawlicki T

    更新日期:2009-12-03 00:00:00

  • Image texture and radiation dose properties in CT.

    abstract::The aim of this study was to compare image noise properties of GE Discovery HD 750 and Toshiba Aquilion ONE. The uniformity section of a Catphan 600 image quality assurance phantom was scanned with both scanners, at different dose levels and with extension rings simulating patients of different sizes. 36 datasets were...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i3.5900

    authors: Mozejko D,Andersen HK,Pedersen M,Waaler D,Martinsen AC

    更新日期:2016-05-08 00:00:00

  • Brachytherapy treatment planning commissioning: effect of the election of proper bibliography and finite size of TG-43 input data on standard treatments.

    abstract::The aim of this work is to evaluate the performance of a commercial brachytherapy treatment planning system (TPS) with TG-43 Vendors Input Data (VID), analyze possible discrepancies with respect to a proper reference source and its implications for standard treatments, and judge the effectiveness of certain widespread...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i4.4730

    authors: Valdés CN,Píriz GH,Lozano E

    更新日期:2015-07-08 00:00:00

  • Increased beam attenuation and surface dose by different couch inserts of treatment tables used in megavoltage radiotherapy.

    abstract::The use of solid carbon fiber table materials in radiotherapy has become more common with the implementation of image-guided radiotherapy (IGRT), since the solid materials give less imaging artifacts than the so-called tennis racket couchtops. The downside of the solid carbon fiber couch inserts is that they increase ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v12i4.3554

    authors: Seppälä JK,Kulmala JA

    更新日期:2011-11-15 00:00:00

  • A seed specific dose kernel method for low-energy brachytherapy dosimetry.

    abstract::We describe a method for independently verifying the dose distributions from pre- and post-implant brachytherapy source distributions. Monte Carlo calculations have been performed to characterize the three-dimensional dose distribution in water phantom from a low-energy brachytherapy source. The calculations are perfo...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v4i1.2543

    authors: DeMarco JJ,Solberg TD,Agazaryan N

    更新日期:2003-01-01 00:00:00

  • Effectiveness of a novel gas-release endorectal balloon in the removal of rectal gas for prostate proton radiation therapy.

    abstract::Endorectal balloons (ERBs) are routinely used in prostate proton radiation therapy to immobilize the prostate and spare the rectal wall. Rectal gas can distend the rectum and displace the prostate even in the presence of ERBs. The purpose of this work was to quantify the effects an ERB with a passive gas release condu...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i5.3945

    authors: Wootton LS,Kudchadker RJ,Beddar AS,Lee AK

    更新日期:2012-09-06 00:00:00

  • AAPM Medical Physics Practice Guideline 5.a.: Commissioning and QA of Treatment Planning Dose Calculations - Megavoltage Photon and Electron Beams.

    abstract::The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education and professional practice of medical physics. The AAPM has more than 8,000 members and is the principal organization of medical physicists in the United States. The...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i5.5768

    authors: Smilowitz JB,Das IJ,Feygelman V,Fraass BA,Kry SF,Marshall IR,Mihailidis DN,Ouhib Z,Ritter T,Snyder MG,Fairobent L,AAPM Medical Physics Practice Guideline Task Group.

    更新日期:2015-09-08 00:00:00

  • FDG PET/CT for rectal carcinoma radiotherapy treatment planning: comparison of functional volume delineation algorithms and clinical challenges.

    abstract::PET/CT imaging could improve delineation of rectal carcinoma gross tumor volume (GTV) and reduce interobserver variability. The objective of this work was to compare various functional volume delineation algorithms. We enrolled 31 consecutive patients with locally advanced rectal carcinoma. The FDG PET/CT and the high...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i5.4696

    authors: Withofs N,Bernard C,Van der Rest C,Martinive P,Hatt M,Jodogne S,Visvikis D,Lee JA,Coucke PA,Hustinx R

    更新日期:2014-09-08 00:00:00

  • A dosimetric comparison of stereotactic body radiation therapy techniques for lung cancer: robotic versus conventional linac-based systems.

    abstract::The aim of this study is to compare the dosimetric characteristics of robotic and conventional linac-based SBRT techniques for lung cancer, and to provide planning guidance for each modality. Eight patients who received linac-based SBRT were retrospectively included in this study. A dose of 60 Gy given in three fracti...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v11i3.3223

    authors: Ding C,Chang CH,Haslam J,Timmerman R,Solberg T

    更新日期:2010-06-29 00:00:00

  • A line-profile based double partial fusion method for acquiring planning CT of oversized patients in radiation treatment.

    abstract::True 3D CT dataset for treatment planning of an oversized patient is difficult to acquire due to the bore size and field of view (FOV) reconstruction. This project aims to provide a simple approach to reconstruct true CT data for oversize patients using CT scanner with limited FOV by acquiring double partial CT (left ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i2.3629

    authors: Wu H,Zhao Q,Cao M,Das I

    更新日期:2012-03-08 00:00:00

  • Calibration coefficients of dosimeters used in mammography for various target/filter combinations.

    abstract::A wide variety of existing combinations of target and filter materials (target/filter combinations) are used in mammography equipment. The patient dose depends on the X-ray quality that is derived from the target/filter combination, and a calibration of the dosimeter that is used in the measurement that corresponds to...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i6.5604

    authors: Sekimoto M,Katoh Y,Katoh T

    更新日期:2015-11-08 00:00:00

  • Linac-based stereotactic radiosurgery (SRS) in the treatment of refractory trigeminal neuralgia: Detailed description of SRS procedure and reported clinical outcomes.

    abstract:PURPOSE/OBJECTIVES:To present our linac-based SRS procedural technique for medically and/or surgically refractory trigeminal neuralgia (TN) treatment and simultaneously report our clinical outcomes. MATERIALS AND METHODS:Twenty-seven refractory TN patients who were treated with a single fraction of 80 Gy to TN. Treatm...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12057

    authors: Pokhrel D,Sood S,McClinton C,Saleh H,Badkul R,Jiang H,Stepp T,Camarata P,Wang F

    更新日期:2017-03-01 00:00:00

  • Quantitative evaluation of breast density using a dual-energy technique on a digital breast tomosynthesis system.

    abstract:PURPOSE:Although breast density is considered a strong risk factor of breast cancer, its quantitative assessment is difficult. To investigate a quantitative method of measuring breast density using dual-energy mammographic imaging with central digital breast tomosynthesis in physically uniform and nonuniform phantoms. ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12618

    authors: Lu KM,Yeh DM,Cao BH,Lin CY,Liang CY,Zhou YB,Tsai CJ

    更新日期:2019-06-01 00:00:00

  • Patient-specific 17-segment myocardial modeling on a bull's eye map.

    abstract::The purpose of this study was to develop and validate cardiac computed tomog-raphy (CT) quantitative analysis software with a patient-specific, 17-segment myocardial model that uses electrocardiogram (ECG)-gated cardiac CT images to differentiate between normal controls and severe aortic stenosis (AS) patients. ECG-ga...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i5.6237

    authors: Jung J,Kim YH,Kim N,Yang DH

    更新日期:2016-09-08 00:00:00

  • Detector system dose verification comparisons for arc therapy: couch vs. gantry mount.

    abstract::The aim of this study was to assess the performance of a gantry-mounted detector system and a couch set detector system using a systematic multileaf collimator positional error manually introduced for volumetric-modulated arc therapy. Four head and neck and esophagus VMAT plans were evaluated by measurement using an e...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i3.4495

    authors: Manikandan A,Sarkar B,Nandy M,Sureka CS,Gossman MS,Sujatha N,Rajendran VT

    更新日期:2014-05-08 00:00:00

  • Stereotactic IMRT for prostate cancer: setup accuracy of a new stereotactic body localization system.

    abstract::The purpose of this work is to prospectively assess the setup accuracy that can be achieved with a stereotactic body localizer (SBL) in immobilizing patients for stereotactic intensity-modulated radiotherapy (IMRT) for prostate cancer. By quantifying this important factor and target mobility in the SBL, we expect to p...

    journal_title:Journal of applied clinical medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1120/jacmp.v5i2.1947

    authors: Wang L,Jacob R,Chen L,Ma C,Movsas B,Feigenberg S,Konski A

    更新日期:2004-04-01 00:00:00

  • Radiation treatment planning and delivery strategies for a pregnant brain tumor patient.

    abstract::The management of a pregnant patient in radiation oncology is an infrequent event requiring careful consideration by both the physician and physicist. The aim of this manuscript was to highlight treatment planning techniques and detail measurements of fetal dose for a pregnant patient recently requiring treatment for ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12262

    authors: Labby ZE,Barraclough B,Bayliss RA,Besemer AE,Dunkerley DAP,Howard SP

    更新日期:2018-09-01 00:00:00

  • A new homogeneity index based on statistical analysis of the dose-volume histogram.

    abstract::The goal of the present study was to develop a new dose-volume histogram (DVH)- based homogeneity index for effectively evaluating the dose homogeneity of intensity-modulated radiotherapy plans. The new index, called the sigma-index ("S-index") is defined as the standard deviation of the normalized differential DVH cu...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v8i2.2390

    authors: Yoon M,Park SY,Shin D,Lee SB,Pyo HR,Kim DY,Cho KH

    更新日期:2007-03-20 00:00:00

  • Accuracy of one algorithm used to modify a planned DVH with data from actual dose delivery.

    abstract::Detection and accurate quantification of treatment delivery errors is important in radiation therapy. This study aims to evaluate the accuracy of DVH based QA in quantifying delivery errors. Eighteen previously treated VMAT plans (prostate, H&N, and brain) were randomly chosen for this study. Conventional IMRT deliver...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i5.6344

    authors: Ma T,Podgorsak MB,Kumaraswamy LK

    更新日期:2016-09-08 00:00:00

  • Independent calculation of dose from a helical TomoTherapy unit.

    abstract::A new calculation algorithm has been developed for independently verifying doses calculated by the TomoTherapy Hi.Art treatment planning system (TPS). The algorithm is designed to confirm the dose to a point in a high dose, low dose-gradient region. Patient data used by the algorithm include the radiological depth to ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v10i1.2772

    authors: Gibbons JP,Smith K,Cheek D,Rosen I

    更新日期:2009-02-05 00:00:00

  • Preclinical assessment of comfort and secure fit of thermobrachytherapy surface applicator (TBSA) on volunteer subjects.

    abstract::A thermobrachytherapy surface applicator (TBSA) was developed for simultaneous heat and brachytherapy treatment of chest wall (CW) recurrence of breast cancer. The ability to comfortably secure the applicator over the upper torso relative to the CW target throughout treatment is assessed on volunteers. Male and postma...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i5.3845

    authors: Arunachalam K,Craciunescu OI,Markewitz EJ,Maccarini PF,Schlorff JL,Stauffer PR

    更新日期:2012-09-06 00:00:00

  • Evaluation of offline adaptive planning techniques in image-guided brachytherapy of cervical cancer.

    abstract::Modern three-dimensional image-guided intracavitary high dose rate (HDR) brachytherapy is often used in combination with external beam radiotherapy (EBRT) to manage cervical cancer. Intrafraction motion of critical organs relative to the HDR applicator in the time between the planning CT and treatment delivery can cau...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12462

    authors: Liu H,Kinard J,Maurer J,Shang Q,Vanderstraeten C,Hayes L,Sintay B,Wiant D

    更新日期:2018-11-01 00:00:00