Repeatability of body sway measurements; day-to-day variation measured by sway magnetometry.

Abstract:

:The postural stability of 30 normal subjects in the age range 15 to 64 years was measured on five separate occasions, using the sway magnetometry technique, to determine the day-to-day repeatability of this measurement technique. On each occasion the pathlength and area enclosed by movement of the hips in a horizontal plane were measured over two 30 s periods with eyes open and eyes closed, with subjects standing on a firm base. Day-to-day repeatability had a standard deviation of 14% for pathlength and 42% for area. Neither the age nor the sex of the subject had any demonstrable effect on the results.

journal_name

Physiol Meas

authors

Elliott C,Murray A

doi

10.1088/0967-3334/19/2/003

subject

Has Abstract

pub_date

1998-05-01 00:00:00

pages

159-64

issue

2

eissn

0967-3334

issn

1361-6579

journal_volume

19

pub_type

杂志文章
  • The variability of the photoplethysmographic signal--a potential method for the evaluation of the autonomic nervous system.

    abstract::The heart rate variability is composed of low- and high-frequency fluctuations, which are mediated by the sympathetic and the parasympathetic nervous systems. The baseline and the amplitude of the photoplethysmographic (PPG) signal also show fluctuations in the same frequencies. In the current study, PPG examinations ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/19/1/008

    authors: Nitzan M,Babchenko A,Khanokh B,Landau D

    更新日期:1998-02-01 00:00:00

  • A comparison of technologies used for estimation of body temperature.

    abstract::Body temperature measurement is an important clinical parameter. The performance of a number of non-invasive thermometers was measured by comparing intra- and inter-operator variability (n = 100) and clinical accuracy (n = 61). Variability was elevated in febrile compared to normothermic subjects for axillary and oral...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/9/003

    authors: Mangat J,Standley T,Prevost A,Vasconcelos J,White P

    更新日期:2010-09-01 00:00:00

  • EIT data noise evaluation in the clinical environment.

    abstract::In the clinical environment the reliable interpretation of EIT images depends on the quality of the data. In the electrically noisy hospital environment the system performance needs to be assessed for each clinical investigation. From the model of noise presented, a figure of merit for comparisons of system performanc...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/17/4a/006

    authors: Meeson S,Blott BH,Killingback AL

    更新日期:1996-11-01 00:00:00

  • Automatic detection of detached and erroneous electrodes in electrical impedance tomography.

    abstract::One unfortunate occurrence in experimental measurements with electrical impedance tomography is electrodes which become detached or poorly connected, such that the measured data cannot be used. This paper presents an automatic approach to detect such erroneous electrodes. It is based on the assumption that all valid m...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/2/017

    authors: Asfaw Y,Adler A

    更新日期:2005-04-01 00:00:00

  • Predicting clinical ischaemia during awake carotid endarterectomy: use of the SJVO2 probe as a guide to selective shunting.

    abstract::Stroke is a major cause of disability within the western world. About 20% of strokes are a consequence of atheromatous narrowing of the origin of the internal carotid artery. Carotid endarterectomy has been shown to be an effective treatment for those with symptomatic and severe stenosis, provided the risk of death an...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/24/2/310

    authors: Crossman J,Banister K,Bythell V,Bullock R,Chambers I,Mendelow AD

    更新日期:2003-05-01 00:00:00

  • Assessment of the dynamic interactions between heart rate and arterial pressure by the cross time-frequency analysis.

    abstract::In this study, a framework for the characterization of the dynamic interactions between RR variability (RRV) and systolic arterial pressure variability (SAPV) is proposed. The methodology accounts for the intrinsic non-stationarity of the cardiovascular system and includes the assessment of both the strength and the p...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/33/3/315

    authors: Orini M,Laguna P,Mainardi LT,Bailón R

    更新日期:2012-03-01 00:00:00

  • Preliminary static EIT images of the thorax in health and disease.

    abstract::The results of a preliminary clinical evaluation of a one-frequency electrical impedance tomography (EIT) system enabling static in vivo imaging are presented. The design of the measuring system and image reconstruction software are described. Thirty-one subjects were examined and divided into four clinical groups. Th...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/23/1/304

    authors: Cherepenin V,Karpov A,Korjenevsky A,Kornienko V,Kultiasov Y,Mazaletskaya A,Mazourov D

    更新日期:2002-02-01 00:00:00

  • A multifrequency multichannel electrical impedance data acquisition system for body fluid shift monitoring.

    abstract::This paper discusses some important issues for the design of electrical impedance measurement systems intended for body fluid shift monitoring, in particular during dialysis treatments. We have studied two common signal generation systems: digital synthesis and carrier recovery. We have found that in prolonged measure...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/16/4/003

    authors: Lozano A,Rosell J,Pallás-Areny R

    更新日期:1995-11-01 00:00:00

  • Trabecular thickness measurement in cancellous bones: postmortem rat studies with the zoom-in micro-tomography technique.

    abstract::Using the cross-sectional images taken with the zoom-in micro-tomography technique, we measured trabecular thicknesses of femur bones in postmortem rats. Since the zoom-in micro-tomography technique is capable of high resolution imaging of a small local region inside a large subject, we were able to measure the trabec...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/5/008

    authors: Cho MH,Chun IK,Lee SC,Cho MH,Lee SY

    更新日期:2005-10-01 00:00:00

  • A randomized controlled trial studying the effect of maternal hyperoxygenation on fetal heart rate in suspected fetal distress.

    abstract:OBJECTIVE:To investigate the effect of maternal hyperoxygenation on fetal heart rate (FHR) when applied for suspected fetal distress during the second stage of term labor. APPROACH:A single-center randomized controlled trial was conducted in a tertiary care hospital in The Netherlands. Participants were included durin...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/abc0b6

    authors: Moors S,Joshi R,Bullens LM,van Oostrum NHM,Regis M,van den Heuvel ER,Oei SG,van Laar JOEH,van der Hout-van der Jagt MB

    更新日期:2020-12-11 00:00:00

  • Empirical estimators of gamma fits to tracer-dilution curves and their technical basis and practical scope.

    abstract::A gamma fit facilitates smoothing and extrapolation of distorted tracer-dilution curves in blood flow studies. Theoretically based empirical estimators were developed as simple alternatives to direct regression approaches from simulated gamma distributions with a wide range of shape asymmetry. Key curve features of pe...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/22/4/401

    authors: Lopatatzidis A,Millard RK

    更新日期:2001-11-01 00:00:00

  • Characterization of cardiorespiratory phase synchronization and directionality in late premature and full term infants.

    abstract:OBJECTIVE:Though the mutual influence of cardiovascular and respiratory rhythms in healthy newborns has been documented, its full characterization is still pending. In general, the activity of many physiological subsystems has a well-expressed rhythmic character, and often an interdependency between physiological rhyth...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aac553

    authors: Lucchini M,Pini N,Fifer WP,Burtchen N,Signorini MG

    更新日期:2018-06-19 00:00:00

  • Is dynamic cerebral autoregulation measurement using transcranial Doppler ultrasound reproducible in the presence of high concentration oxygen and carbon dioxide?

    abstract::Reliability of cerebral blood flow velocity (CBFV) and dynamic cerebral autoregulation estimates (expressed as autoregulation index: ARI) using spontaneous fluctuations in blood pressure (BP) has been demonstrated. However, reliability during co-administration of O2 and CO2 is unknown. Bilateral CBFV (using transcrani...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/5/673

    authors: Minhas JS,Syed NF,Haunton VJ,Panerai RB,Robinson TG,Mistri AK

    更新日期:2016-05-01 00:00:00

  • Effect of body mass index (BMI) on estimation of extracellular volume (ECV) in hemodialysis (HD) patients using segmental and whole body bioimpedance analysis.

    abstract::The aim of the study was to investigate whether body mass index (BMI) influences the estimation of extracellular volume (ECV) in hemodialysis (HD) patients when using segmental bioimpedance analysis (SBIA) compared to wrist-to-ankle bioimpedance analysis (WBIA) during HD with ultrafiltration (UF). Twenty five HD patie...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/26/2/009

    authors: Carter M,Morris AT,Zhu F,Zaluska W,Levin NW

    更新日期:2005-04-01 00:00:00

  • Measurement of pupil reactivity using fast pupillometry.

    abstract::Analysis of human eye pupil reactivity is a very valuable diagnostic method used mainly for evaluation of the condition of the autonomic nervous system and the visual system. The paper presents an experimental pupillometer built in the Institute of Physics of the Wroclaw University of Technology. The apparatus makes i...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/1/006

    authors: Hachol A,Szczepanowska-Nowak W,Kasprzak H,Zawojska I,Dudzinski A,Kinasz R,Wygledowska-Promienska D

    更新日期:2007-01-01 00:00:00

  • Monitoring of heart rate and inter-beat intervals with wrist plethysmography in patients with atrial fibrillation.

    abstract:OBJECTIVE:Atrial fibrillation (AF) causes marked risk for patients, while silent fibrillation may remain unnoticed if not suspected and screened. Development of comfortable yet accurate beat-to-beat heart rate (HR) monitoring with good AF detection sensitivity would facilitate screening and improve treatment. The purpo...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aac9a9

    authors: Harju J,Tarniceriu A,Parak J,Vehkaoja A,Yli-Hankala A,Korhonen I

    更新日期:2018-06-27 00:00:00

  • Relationship between detrended fluctuation analysis and spectral analysis of heart-rate variability.

    abstract::The recently-introduced technique of detrended fluctuation analysis (DFA) for heart-rate variability appears to yield improved prognostic power in cardiovascular disease through calculation of the fractal scaling exponent alpha. However, the physiological meaning of alpha remains unclear. In DFA, the signal is segment...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/23/2/314

    authors: Willson K,Francis DP,Wensel R,Coats AJ,Parker KH

    更新日期:2002-05-01 00:00:00

  • Direct EIT Jacobian calculations for conductivity change and electrode movement.

    abstract::Electrical impedance tomography (EIT) is very sensitive to deformations of the medium boundary shape. For lung imaging, breathing and changes in posture move the electrodes and change the chest shape, resulting in image artefacts. Several approaches have been proposed to improve the reconstructed images; most methods ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/6/S08

    authors: Gómez-Laberge C,Adler A

    更新日期:2008-06-01 00:00:00

  • A comb filter based signal processing method to effectively reduce motion artifacts from photoplethysmographic signals.

    abstract::A photoplethysmographic (PPG) signal can provide very useful information about a subject's cardiovascular status. Motion artifacts (MAs), which usually deteriorate the waveform of a PPG signal, severely obstruct its applications in the clinical diagnosis and healthcare area. To reduce the MAs from a PPG signal, in the...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/10/2159

    authors: Peng F,Liu H,Wang W

    更新日期:2015-10-01 00:00:00

  • Restoration of the electrocardiogram during mechanical cardiopulmonary resuscitation.

    abstract:OBJECTIVE:An artefact-free electrocardiogram (ECG) is essential during cardiac arrest to decide therapy such as defibrillation. Mechanical cardiopulmonary resuscitation (CPR) devices cause movement artefacts that alter the ECG. This study analyzes the effectiveness of mechanical CPR artefact suppression filters to rest...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab9e53

    authors: Isasi I,Irusta U,Aramendi E,Idris AH,Sörnmo L

    更新日期:2020-11-06 00:00:00

  • Association between RR interval and high-frequency heart rate variability acquired during short-term, resting recordings with free and paced breathing.

    abstract::High-frequency (HF) oscillations in RR interval from 0.15-0.40 Hz are widely accepted as a measure of cardiac vagal outflow but the HF/RR relationship appears complex, particularly with longer RR intervals. The aim of this study was to evaluate the HF/RR interval relationship during free and paced breathing. HF power ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/7/008

    authors: Sandercock G,Gladwell V,Dawson S,Nunan D,Brodie D,Beneke R

    更新日期:2008-07-01 00:00:00

  • Physiological motion monitoring: a wearable device and adaptative algorithm for sit-to-stand timing detection.

    abstract::A simple wearable device for sit-to-stand timing detection was designed and constructed with rate gyroscopes and accelerometers and a dedicated adaptive algorithm. The method was validated by comparison with optoelectronic equipment. Results from the comparison showed a maximal error always lower than 2.5 x 10(-2) s f...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/27/8/006

    authors: Giansanti D,Maccioni G

    更新日期:2006-08-01 00:00:00

  • Patient examinations using electrical impedance tomography--sources of interference in the intensive care unit.

    abstract::Electrical impedance tomography (EIT) is expected to become a valuable tool for monitoring mechanically ventilated patients due to its ability to continuously assess regional lung ventilation and aeration. Several sources of interference with EIT examinations exist in intensive care units (ICU). Our objectives are to ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/12/F01

    authors: Frerichs I,Pulletz S,Elke G,Gawelczyk B,Frerichs A,Weiler N

    更新日期:2011-12-01 00:00:00

  • Validation of x-ray fluorescence measurements of metals in toenail clippings against inductively coupled plasma mass spectrometry in a Nigerian population.

    abstract:OBJECTIVE:Metal exposures have been linked with many adverse health outcomes affecting nearly every system in the body. Exposure to metals has been tracked primarily using blood. Blood metal concentrations have drawbacks as biomarkers stemming from the metals' short biologic half-lives, shipping and storage requirement...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aad947

    authors: Specht AJ,Kponee K,Nkpaa KW,Balcom PH,Weuve J,Nie LH,Weisskopf MG

    更新日期:2018-08-31 00:00:00

  • Wavelet bidomain sample entropy analysis to predict spontaneous termination of atrial fibrillation.

    abstract::The ability to predict if an atrial fibrillation (AF) episode terminates spontaneously or not through non-invasive techniques is a challenging problem of great clinical interest. This fact could avoid useless therapeutic interventions and minimize the risks for the patient. The present work introduces a robust AF pred...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/1/005

    authors: Alcaraz R,Rieta JJ

    更新日期:2008-01-01 00:00:00

  • Coupling between arterial pressure, cerebral blood velocity, and cerebral tissue oxygenation with spontaneous and forced oscillations.

    abstract::We tested the hypothesis that transmission of arterial pressure to brain tissue oxygenation is low under conditions of arterial pressure instability. Two experimental models of hemodynamic instability were used in healthy human volunteers; (1) oscillatory lower body negative pressure (OLBNP) (N = 8; 5 male, 3 female),...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/4/785

    authors: Rickards CA,Sprick JD,Colby HB,Kay VL,Tzeng YC

    更新日期:2015-04-01 00:00:00

  • The impact of electrode area, contact impedance and boundary shape on EIT images.

    abstract::Electrical impedance tomography (EIT) measures the conductivity distribution within an object based on the current applied and voltage measured at surface electrodes. Thus, EIT images are sensitive to electrode properties (i.e. contact impedance, electrode area and boundary shape under the electrode). While some of th...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/7/S02

    authors: Boyle A,Adler A

    更新日期:2011-07-01 00:00:00

  • A bio-telemetric device for measurement of left ventricular pressure-volume loops using the admittance technique in conscious, ambulatory rats.

    abstract::This paper presents the design, construction and testing of a device to measure pressure-volume loops in the left ventricle of conscious, ambulatory rats. Pressure is measured with a standard sensor, but volume is derived from data collected from a tetrapolar electrode catheter using a novel admittance technique. Ther...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/6/007

    authors: Raghavan K,Feldman MD,Porterfield JE,Larson ER,Jenkins JT,Escobedo D,Pearce JA,Valvano JW

    更新日期:2011-06-01 00:00:00

  • Estimating carotid pulse and breathing rate from near-infrared video of the neck.

    abstract:OBJECTIVE:Non-contact physiological measurement is a growing research area that allows capturing vital signs such as heart rate (HR) and breathing rate (BR) comfortably and unobtrusively with remote devices. However, most of the approaches work only in bright environments in which subtle photoplethysmographic and balli...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aae625

    authors: Chen W,Hernandez J,Picard RW

    更新日期:2018-10-30 00:00:00

  • Thermography and colour duplex ultrasound assessments of arterio-venous fistula function in renal patients.

    abstract::Vascular and clinical assessments of arterio-venous fistula (AVF) function and access are important in patients undergoing or preparing to undergo renal dialysis. Objective assessment techniques include colour duplex ultrasound and more recently medical infrared thermography. Ideally, these should help assess problems...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/27/1/005

    authors: Allen J,Oates CP,Chishti AD,Ahmed IA,Talbot D,Murray A

    更新日期:2006-01-01 00:00:00