Peripheral T-cell lymphoma of the colon: double-contrast barium enema examination findings in six patients.

Abstract:

PURPOSE:To evaluate radiologic findings of peripheral T-cell lymphoma (PTCL) of the colon at double-contrast barium enema examination. MATERIALS AND METHODS:Double-contrast barium enema findings in six patients with pathologically proved PTCL of the colon were retrospectively evaluated and compared with colonoscopic and histopathologic findings. RESULTS:There was a diffuse involvement of almost all segments of the colon in four patients and a focal segmental involvement in two. Frequent findings at double-contrast barium enema examination included geographic ulcerations (n = 6), aphthous ulcerations (n = 4), pseudopolyps (n = 4), circumferential luminal narrowing (n = 4), and ileocecal deformity (n = 4). CONCLUSION:PTCL of the colon manifested as either a diffuse or a focal segmental lesion and showed extensive mucosal ulceration at double-contrast barium enema examination. These findings are similar to those of inflammatory bowel disease and are different from those of colorectal lymphoma with the B-cell phenotype.

journal_name

Radiology

journal_title

Radiology

authors

Lee HJ,Han JK,Kim TK,Kim YH,Kim KW,Choi BI

doi

10.1148/radiology.218.3.r01mr23751

subject

Has Abstract

pub_date

2001-03-01 00:00:00

pages

751-6

issue

3

eissn

0033-8419

issn

1527-1315

journal_volume

218

pub_type

杂志文章
  • Atypical radiographic features in Pneumocystis carinii pneumonia.

    abstract::The chest films in 30 proved cases of Pneumocystis carinii pneumonia were reviewed to determine the incidence of atypical radiographic findings. Seventeen of 30 patients or 56% presented at least one atypical radiographic finding during the course of the disease. Unilateral distribution, lobar involvement, abscess for...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/114.1.39

    authors: Doppman JL,Geelhoed GW,De Vita VT

    更新日期:1975-01-01 00:00:00

  • Normal modiolus: CT appearance in patients with a large vestibular aqueduct.

    abstract:PURPOSE:To determine the computed tomographic (CT) appearance of the normal modiolus and the pathologic alteration in patients with a large vestibular aqueduct and an otherwise normal-appearing cochlea. MATERIALS AND METHODS:Temporal bone CT studies obtained before and after a major upgrade of CT capability in 1992 we...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.204.1.9205250

    authors: Lemmerling MM,Mancuso AA,Antonelli PJ,Kubilis PS

    更新日期:1997-07-01 00:00:00

  • Gallium scanning as a screening test for inflammatory lesions.

    abstract::Of the 67-Ga scans obtained in 42 patients with fever and suspected inflammatory lesions, 17 were positive. In 9 patients the scans yielded information about localized inflammation not provided by previous studies. Four patients did not have an inflammatory lesion at the positive site. Ten of 13 abscesses or inflamed ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/116.2.383

    authors: Teates CD,Hunter JG Jr

    更新日期:1975-08-01 00:00:00

  • Inflammatory fibroid polyp of the colon simulating malignancy.

    abstract::The authors report an inflammatory fibroid polyp of the colon which simulated a tumor on the air-contrast barium-enema examination. Histological evaluation revealed the inflammatory nature of the polyp. These rare lesions can be radiographically indistinguishable from primary colon carcinoma. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.149.1.6611950

    authors: Ferin P,Skucas J

    更新日期:1983-10-01 00:00:00

  • Case 224: Cardiac Involvement in Erdheim-Chester Disease.

    abstract::History A 61-year-old man with no relevant medical history was admitted to the emergency department with symptoms of congestive heart failure and a 1-week history of chest pain, progressive dyspnea, abdominal swelling, bipedal edema, and anorexia. Laboratory test results, including complete blood count and electrolyte...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015131751

    authors: de Miguel Criado J,Aguilera Del Hoyo LF,García Del Salto L,Cueva Pérez E,Casado Cerrada J,Nieto Llanos S,Porro Fernández JC,Fraga Rivas P

    更新日期:2015-12-01 00:00:00

  • Uterine artery embolization in sheep: comparison of acute effects with polyvinyl alcohol particles and calibrated microspheres.

    abstract:PURPOSE:To compare the effects on the myometrium of polyvinyl alcohol (PVA) particles and calibrated microspheres (MS) in embolization of the uterine arteries in sheep. MATERIALS AND METHODS:Superselective and bilateral embolization of the uterine arteries was performed with PVA particles and calibrated MS within 24 h...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2242010847

    authors: Pelage JP,Laurent A,Wassef M,Bonneau M,Germain D,Rymer R,Flaud P,Martal J,Merland JJ

    更新日期:2002-08-01 00:00:00

  • Concomitant boron-neutron capture therapy during fast-neutron irradiation of a rat glioma.

    abstract:PURPOSE:Fast-neutron irradiation and boron-neutron capture therapy (BNCT) have been independently investigated as treatments for malignant disease. This study tested the feasibility of enhancing fast-neutron irradiation with concomitant BNCT. MATERIALS AND METHODS:Seventeen male Fisher rats, each weighing 180-200 g an...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.191.3.8184080

    authors: Buchholz TA,Rasey JS,Laramore GE,Livesey JC,Chin L,Risler R,Hamlin DK,Spence AM,Griffin TW

    更新日期:1994-06-01 00:00:00

  • Exaggerated anterior vertebral notching.

    abstract::Three children with marrow-packing disorders demonstrated exaggerated anterior vertebral notches with poorly defined cortical margins. One child had thalassemia major, another had Gaucher disease, and a third had metastatic neuroblastoma. A discussion of each case and the etiology of the notches is presented. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/131.2.367

    authors: Mandell GA,Kricun ME

    更新日期:1979-05-01 00:00:00

  • Cardiac function: MR evaluation in one breath hold with real-time true fast imaging with steady-state precession.

    abstract::In 12 healthy volunteers and eight patients with cardiac disease, cine magnetic resonance (MR) imaging in the heart was performed with real-time true fast imaging with steady-state precession (FISP), which permitted evaluation of the entire left ventricle in one breath hold (91 msec per frame, 13 frames per section po...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2223011156

    authors: Lee VS,Resnick D,Bundy JM,Simonetti OP,Lee P,Weinreb JC

    更新日期:2002-03-01 00:00:00

  • Cartilage quality assessment by using glycosaminoglycan chemical exchange saturation transfer and (23)Na MR imaging at 7 T.

    abstract:PURPOSE:To compare a glycosaminoglycan chemical exchange saturation transfer (gagCEST) imaging method, which enables sampling of the water signal as a function of the presaturation offset (z-spectrum) at 13 points in clinically feasible imaging times, with sodium 23 ((23)Na) magnetic resonance (MR) imaging in patients ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.11101841

    authors: Schmitt B,Zbýn S,Stelzeneder D,Jellus V,Paul D,Lauer L,Bachert P,Trattnig S

    更新日期:2011-07-01 00:00:00

  • Can optical imaging assist in characterization of the onset of angiogenesis in developing hepatic metastases in mice livers?

    abstract::Optical imaging currently can be used to characterize some of the early steps in the angiogenic pathway in vivo in animals. Liu and Matsui have provided valuable information in regard to the sequential changes in the origin and nature of newly formed blood vessels during progressive stages of growth of hepatic colorec...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2432061988

    authors: Kruskal JB

    更新日期:2007-05-01 00:00:00

  • Ultra-Low-Dose 18F-Florbetaben Amyloid PET Imaging Using Deep Learning with Multi-Contrast MRI Inputs.

    abstract::Purpose To reduce radiotracer requirements for amyloid PET/MRI without sacrificing diagnostic quality by using deep learning methods. Materials and Methods Forty data sets from 39 patients (mean age ± standard deviation [SD], 67 years ± 8), including 16 male patients and 23 female patients (mean age, 66 years ± 6 and ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2018180940

    authors: Chen KT,Gong E,de Carvalho Macruz FB,Xu J,Boumis A,Khalighi M,Poston KL,Sha SJ,Greicius MD,Mormino E,Pauly JM,Srinivas S,Zaharchuk G

    更新日期:2019-03-01 00:00:00

  • Prostate cancer: sextant localization at MR imaging and MR spectroscopic imaging before prostatectomy--results of ACRIN prospective multi-institutional clinicopathologic study.

    abstract:PURPOSE:To determine the incremental benefit of combined endorectal magnetic resonance (MR) imaging and MR spectroscopic imaging, as compared with endorectal MR imaging alone, for sextant localization of peripheral zone (PZ) prostate cancer. MATERIALS AND METHODS:This prospective multicenter study, conducted by the Am...

    journal_title:Radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1148/radiol.2511080409

    authors: Weinreb JC,Blume JD,Coakley FV,Wheeler TM,Cormack JB,Sotto CK,Cho H,Kawashima A,Tempany-Afdhal CM,Macura KJ,Rosen M,Gerst SR,Kurhanewicz J

    更新日期:2009-04-01 00:00:00

  • Ruptured intracranial aneurysms: acute endovascular treatment with electrolytically detachable coils--a prospective randomized study.

    abstract:PURPOSE:To compare the use of electrolytically detachable coils versus surgical ligation for the management of acutely ruptured intracranial aneurysm. MATERIALS AND METHODS:A prospective randomized study included 109 patients with acute (< 72 hours) subarachnoid hemorrhage caused by a ruptured aneurysm (Hunt and Hess ...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1148/radiology.211.2.r99ap06325

    authors: Vanninen R,Koivisto T,Saari T,Hernesniemi J,Vapalahti M

    更新日期:1999-05-01 00:00:00

  • Multi-detector row CT coronary angiography: influence of reconstruction technique and heart rate on image quality.

    abstract:PURPOSE:To prospectively evaluate to what extent image quality in 16-detector row computed tomographic (CT) coronary angiography is a function of the heart rate and the image reconstruction technique used. MATERIALS AND METHODS:A total of 70 patients (49 men, 21 women; mean age, 59.1 years +/- 5.8 [standard deviation]...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2381041595

    authors: Herzog C,Arning-Erb M,Zangos S,Eichler K,Hammerstingl R,Dogan S,Ackermann H,Vogl TJ

    更新日期:2006-01-01 00:00:00

  • Sodium imaging of human body organs and extremities in vivo.

    abstract::In vivo sodium magnetic resonance (MR) images of various structures--such as the heart, chest wall, kidneys, spine, liver, gallbladder, breasts, knees, hands, and feet--were obtained at 1.9 T. Improved sensitivity relative to standard spin-echo imaging was achieved with use of a modified three-dimensional acquisition ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.167.2.3357970

    authors: Granot J

    更新日期:1988-05-01 00:00:00

  • Computed tomography: demonstration of contrast medium within cystic tumors.

    abstract::Two cases demonstrated that intravenously injected contrast medium entered cystic lesions. It appears that both vascular opacification and transgression of the blood-brain barrier play major roles in contrast enhancement. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/120.2.345

    authors: Messina AV,Potts DG,Rottenberg D,Patterson RH

    更新日期:1976-08-01 00:00:00

  • Radiology of athletic injuries: football.

    abstract::During a 17-year period, 33 injuries produced radiographic abnormalities in 26 members of a professional football team. Sites of injury were correlated with playing position and protective equipment worn at the time of injury. Fractures of multiple transverse processes of the lumbar spine are reported in offensive hal...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/117.1.33

    authors: Bowerman JW,McDonnell EJ

    更新日期:1975-10-01 00:00:00

  • Focal organizing pneumonia: CT appearance.

    abstract:PURPOSE:To clarify the computed tomographic (CT) features of focal organizing pneumonia. MATERIALS AND METHODS:The authors retrospectively studied CT scans of 18 patients with histologically proved focal organizing pneumonia. Chest radiographs in all 18 patients suggested bronchogenic carcinoma. RESULTS:Seventeen of ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.189.1.8372180

    authors: Kohno N,Ikezoe J,Johkoh T,Takeuchi N,Tomiyama N,Kido S,Kondoh H,Arisawa J,Kozuka T

    更新日期:1993-10-01 00:00:00

  • Impassable ureteral strictures: management with percutaneous ureteroneocystostomy.

    abstract::Sixteen of 227 patients referred for percutaneous placement of a ureteral stent had impassable stenoses. Stenoses were benign (n = 8) or attributed to malignant retroperitoneal neoplasm (n = 8). Electrocautery was used to create a neotract between the stenosed ureter and the bladder or ileal loop. A double-J stent was...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.180.2.2068310

    authors: Cornud FE,Casanova JM,Bonnel DH,Helenon OR,Hanna SM,Chretien YR,Dufour BF,Moreau JF

    更新日期:1991-08-01 00:00:00

  • Pancreatic cystosis in cystic fibrosis.

    abstract::Two patients with cystic fibrosis and pancreatic cystosis are described who had complete replacement of the pancreas by multiple macroscopic cysts. The possible causes and clinical significance of this condition are discussed. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.158.3.3511500

    authors: Hernanz-Schulman M,Teele RL,Perez-Atayde A,Zollars L,Levine J,Black P,Kuligowska E

    更新日期:1986-03-01 00:00:00

  • Acute nontraumatic abdominal pain in adult patients: abdominal radiography compared with CT evaluation.

    abstract:PURPOSE:To compare the diagnostic yield of abdominal radiography with that of computed tomography (CT) in adult patients presenting to the emergency department with nontraumatic abdominal pain. MATERIALS AND METHODS:Records of 1,000 consecutive patients presenting to the emergency department with acute abdominal pain ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2251011282

    authors: Ahn SH,Mayo-Smith WW,Murphy BL,Reinert SE,Cronan JJ

    更新日期:2002-10-01 00:00:00

  • Fructose-1,6-Bisphosphatase 1 Reduces 18F FDG Uptake in Hepatocellular Carcinoma.

    abstract::Purpose To determine whether fructose 1,6-bisphosphatase 1 (FBP1) expression is associated with fluorine 18 (18F) fluorodeoxyglucose (FDG) accumulation in patients with hepatocellular carcinoma (HCC) and to investigate how FBP1 expression and 18F FDG uptake are related to tumor differentiation grade and metabolism and...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2017161607

    authors: Chen R,Li J,Zhou X,Liu J,Huang G

    更新日期:2017-09-01 00:00:00

  • Potential living liver donors: evaluation with an all-in-one protocol with multi-detector row CT.

    abstract::Multi-detector row computed tomography was performed for the preharvest evaluation of 14 potential living liver donors. Both a biliary contrast agent and a conventional iodinated contrast agent were administered intravenously. This protocol included acquisition of three subsequent scans and allowed accurate assessment...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2242011340

    authors: Schroeder T,Nadalin S,Stattaus J,Debatin JF,Malagó M,Ruehm SG

    更新日期:2002-08-01 00:00:00

  • Duplication of the müllerian ducts and genitourinary malformations. Part II: analysis of malformations.

    abstract::Forty-seven females with duplication of the uterus and cervix were retrospectively studied to obtain a better understanding of the reasons for failure of fusion of the müllerian ducts by analyzing the associated genitourinary malformations. Thirty-one of the 47 patients had major genitourinary malformations that corre...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.144.4.6213980

    authors: Gilsanz V,Cleveland RH,Reid BS

    更新日期:1982-09-01 00:00:00

  • Dose efficiency of screen-film systems used in pediatric radiography.

    abstract::Twenty-one screen-film systems were examined using contrast-detail-dose methods in order to determine which were most dose-efficient for use in pediatric radiography. With a given screen, dose efficiency in the noise-limited region (contrast approximately equal to 0.05) was more or less constant (within the range of e...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.152.1.6729110

    authors: Cohen G,Wagner LK,McDaniel DL,Robinson LH

    更新日期:1984-07-01 00:00:00

  • Quantification of bone involvement in Gaucher disease: MR imaging bone marrow burden score as an alternative to Dixon quantitative chemical shift MR imaging--initial experience.

    abstract:PURPOSE:To develop a semiquantitative magnetic resonance (MR) imaging bone marrow burden (BMB) score with inclusion of both axial and peripheral bone marrow in Gaucher disease as an alternative to MR imaging with the Dixon quantitative chemical shift imaging (QCSI) technique. MATERIALS AND METHODS:Two experienced musc...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2292020296

    authors: Maas M,van Kuijk C,Stoker J,Hollak CE,Akkerman EM,Aerts JF,den Heeten GJ

    更新日期:2003-11-01 00:00:00

  • Hepatic malignancies: improved detection with pulse-inversion US in late phase of enhancement with SH U 508A-early experience.

    abstract::Twenty consecutive patients with known liver malignancies underwent ultrasonography (US) in conventional B mode and in pulse-inversion mode in the late hepatic-specific parenchymal phase after intravenous administration of SH U 508A, a microbubble US contrast agent. Two experienced readers assessed subjective and obje...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.216.3.r00se22903

    authors: Harvey CJ,Blomley MJ,Eckersley RJ,Cosgrove DO,Patel N,Heckemann RA,Butler-Barnes J

    更新日期:2000-09-01 00:00:00

  • Subjective vs. objective evaluation of gallbladder opacification during oral cholecystography in comparative clinical trials: implications for studies involving visual assessment.

    abstract::Radiographs and CT images taken during oral cholecystography in dogs were interpreted in an independent, blind fashion by three radiologists on two occasions and visual assessment of gallbladder density compared to the actual CT values. While there was significant intra- and inter-observer variation, the mean scores f...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.144.2.7089280

    authors: Fon GT,Hunter TB,Berk RN,Patton DD,Capp MP

    更新日期:1982-07-01 00:00:00

  • Suspected appendicitis in children: diagnostic importance of normal abdominopelvic CT findings with nonvisualized appendix.

    abstract:PURPOSE:To determine whether lack of visualization of the appendix on otherwise normal abdominopelvic computed tomographic (CT) images can help exclude appendicitis in the pediatric population. MATERIALS AND METHODS:The study was institutional review board approved and HIPAA compliant. One thousand one hundred thirty-...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2502080624

    authors: Garcia K,Hernanz-Schulman M,Bennett DL,Morrow SE,Yu C,Kan JH

    更新日期:2009-02-01 00:00:00