Abstract:
:In 12 healthy volunteers and eight patients with cardiac disease, cine magnetic resonance (MR) imaging in the heart was performed with real-time true fast imaging with steady-state precession (FISP), which permitted evaluation of the entire left ventricle in one breath hold (91 msec per frame, 13 frames per section position, nine short-axis section positions per breath hold). Contrast-to-noise ratios (CNRs) and left ventricular mass and function measurements with this technique were compared in all subjects with single-section true FISP imaging and, in the volunteers only, with segmented fast low-angle shot (FLASH) MR imaging. Myocardium-to-blood CNR was significantly higher for both true FISP sequences compared with the FLASH sequence. Measurements of resting left ventricular function with real-time true FISP imaging were comparable with those derived from a series of separate breath-hold single-section true FISP acquisitions.
journal_name
Radiologyjournal_title
Radiologyauthors
Lee VS,Resnick D,Bundy JM,Simonetti OP,Lee P,Weinreb JCdoi
10.1148/radiol.2223011156subject
Has Abstractpub_date
2002-03-01 00:00:00pages
835-42issue
3eissn
0033-8419issn
1527-1315journal_volume
222pub_type
杂志文章相关文献
RADIOLOGY文献大全abstract::The computed tomographic (CT) findings in six patients with periportal tuberculous adenitis were reviewed retrospectively to analyze the main morphologic features of the disease. In all patients, hypodense lymph nodes were observed close to the porta hepatis, with peripheral enhancement seen after administration of co...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.161.3.3786720
更新日期:1986-12-01 00:00:00
abstract:PURPOSE:To test the technical feasibility and results of placement of metal stents into ureters obstructed by extensive tumor. MATERIALS AND METHODS:Six consecutive patients (two men and four women, aged 35-66 years and with incurable malignancies) underwent insertion of metallic endoprostheses in nine obstructed uret...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.191.3.8184060
更新日期:1994-06-01 00:00:00
abstract::Remote viewing of ultrasound scans facilitates assessment of a student's technique while minimizing anxiety for both him and the patient. This method may also be effective for the busy physician who must monitor several procedures at the same time. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/132.1.231a
更新日期:1979-07-01 00:00:00
abstract:PURPOSE:To determine whether polytetrafluoroethylene (PTFE) stent-grafts yield longer patency for creation or revision of transjugular intrahepatic portosystemic shunts (TIPS). MATERIALS AND METHODS:Fourteen PTFE-covered Wallstents were placed in 13 patients with TIPS: seven at shunt creation and seven during revision...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.213.3.r99dc28759
更新日期:1999-12-01 00:00:00
abstract::Purpose To compare the diagnostic performance of minimally invasive autopsy with that of conventional autopsy. Materials and Methods For this prospective, single-center, cross-sectional study in an academic hospital, 295 of 2197 adult cadavers (mean age: 65 years [range, 18-99 years]; age range of male cadavers: 18-99...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2018180924
更新日期:2018-12-01 00:00:00
abstract::New or enlarging solitary pulmonary opacities in 502 patients were evaluated with a plain tomographic procedure. Repeat chest radiographs in 64 patients and tomograms in 115 patients showed that the opacities were not nodules but were due to pneumonitis, rib lesions, thickened pleura, or another benign finding. Tomogr...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.163.2.3562830
更新日期:1987-05-01 00:00:00
abstract::The authors describe a modified Seldinger Technique for sialography which is especially helpful in cannulization of the submandibular ducts. This procedure was successful in 2. of 30 patients tested. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/123.1.232
更新日期:1977-04-01 00:00:00
abstract:PURPOSE:To compare and evaluate the measures of costs for core-needle and surgical breast biopsies. MATERIALS AND METHODS:Three measures of costs were evaluated: (a) input resources, (b) actual payments, and (c) billed charges. A combination of methods were used for data collection from 10 sites enrolled in a large-sc...
journal_title:Radiology
pub_type: 临床试验,杂志文章,多中心研究,随机对照试验
doi:10.1148/radiology.212.1.r99jl46181
更新日期:1999-07-01 00:00:00
abstract:PURPOSE:To determine if the intradecidual sign at sonography is effective in the diagnosis of early intrauterine pregnancy. MATERIALS AND METHODS:In 102 pregnant patients, transvaginal sonography revealed an intrauterine fluid collection without a yolk sac or embryo. Four observers (experienced sonologist, body imagin...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.204.3.9280240
更新日期:1997-09-01 00:00:00
abstract:PURPOSE:To correlate intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) parameters with the enhancement patterns of bone marrow and focal lesion obtained on whole-body (WB) dynamic contrast agent-enhanced (DCE) magnetic resonance (MR) images in patients with stage-III multiple myeloma (MM) before and ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2015141728
更新日期:2015-12-01 00:00:00
abstract:PURPOSE:To characterize the effect of low-frequency contrast material-enhanced ultrasound on the vascular endothelium and to determine the parameters and techniques required to deliver a therapeutic agent by using the chorioallantoic membrane (CAM) model. MATERIALS AND METHODS:All in vivo animal procedures were conduc...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2431060167
更新日期:2007-04-01 00:00:00
abstract::In a comparison of conventional and magnetic resonance (MR) angiography of the lower extremities, MR imaging was performed with extremity and body coils and a unilateral six-coil telescopic phased-array coil. In one of seven volunteers, average signal-to-noise ratio was 140% higher with the latter (p < .01), only thre...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.196.3.7644660
更新日期:1995-09-01 00:00:00
abstract::Multi-detector row computed tomography was performed for the preharvest evaluation of 14 potential living liver donors. Both a biliary contrast agent and a conventional iodinated contrast agent were administered intravenously. This protocol included acquisition of three subsequent scans and allowed accurate assessment...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2242011340
更新日期:2002-08-01 00:00:00
abstract::A previous study determined the normal values and upper limits of liver size, as measured by the longitudinal and sagittal diameters in the midclavicular line and the midline. The present study was performed to determine which of the four sonographic diameters best differentiates between patients who have liver diseas...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.153.2.6385110
更新日期:1984-11-01 00:00:00
abstract::Successful balloon catheter dilatation through the defunctionalized limb of a colostomy was performed in three infants with postischemic colonic stricture. This experience suggests that balloon catheter dilatation can be an alternative to surgical resection in treating delayed ischemic colonic stricture. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.149.2.6622690
更新日期:1983-11-01 00:00:00
abstract::Esophageal atresia may be associated with a long interval or gap between the upper and lower pouches. Despite a variety of procedures to elongate the esophagus, surgeons have been unable to achieve esophageal continuity in many patients. Three infants with esophageal atresia and long gaps recently underwent hydrostati...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.171.3.2717760
更新日期:1989-06-01 00:00:00
abstract::The "comet tail" is a well-known ultrasound artifact that appears as a series of parallel bands radiating from a source. This artifact was observed in the gallbladder lumen in eight of 10 patients after extracorporeal shock wave lithotripsy of radiolucent calculi. To investigate the cause of the comet tail artifact, c...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.177.1.2204960
更新日期:1990-10-01 00:00:00
abstract::The use of intensity-modulated radiation therapy for treatment of dominant intraprostatic lesions may require integration of functional magnetic resonance (MR) imaging with treatment-planning computed tomography (CT). The purpose of this study was to compare prospectively the landmark and iterative closest point metho...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2361040560
更新日期:2005-07-01 00:00:00
abstract:PURPOSE:To investigate whether apparent diffusion coefficients (ADCs) derived from diffusion-weighted (DW) magnetic resonance (MR) imaging at 3 T correlate with the clinical risk of prostate cancer in patients with tumors that are visible on MR images, with MR imaging/transrectal ultrasonography (US) fusion-guided biop...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.10100667
更新日期:2011-02-01 00:00:00
abstract::Radiographic findings previously thought pathognomonic for juvenile nasopharyngeal angiofibroma are anterior bowing of the posterior wall of the maxillary antrum on plain films or tomography, and a dense homogeneous blush on angiography. Two patients presented with nasopharyngeal masses which mimicked angiofibroma rad...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/127.2.425
更新日期:1978-05-01 00:00:00
abstract::The results of percutaneous drainage of abdominal abscesses in 136 patients are analyzed, revealing a failure rate of 23% (31 patients). The mortality rate was 1.4% (two patients); the rate of serious complications was 5% (seven patients). Failure rate was lowest in critically ill patients having palliative drainage o...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.159.2.2421370
更新日期:1986-05-01 00:00:00
abstract::The rates of diabetes, obesity, and metabolic disease have reached epidemic proportions worldwide. In recent years there has been renewed interest in combating these diseases not only by modifying energy intake and lifestyle factors, but also by inducing endogenous energy expenditure. This approach has largely been st...
journal_title:Radiology
pub_type: 杂志文章,评审
doi:10.1148/radiol.2016150390
更新日期:2016-07-01 00:00:00
abstract:PURPOSE:To prospectively evaluate the feasibility of magnetic resonance (MR) coronary artery imaging and to define myocardial damage with late-enhancement myocardial MR imaging in children who underwent arterial switch surgery for transposition of the great arteries. MATERIALS AND METHODS:The local research ethics com...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2342032059
更新日期:2005-02-01 00:00:00
abstract::A radionuclide study using technetium-99m-labelled milk feeding is described for the detection of gastroesophageal reflux and aspiration in children. A comparison of findings in 39 patients referred for both radiographic and radionuclide studies showed that barium studies were positive in 25.6% and radionuclide studie...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/131.2.479
更新日期:1979-05-01 00:00:00
abstract::Magnetic resonance (MR) imaging and computed tomography (CT) were used to study severe syringomyelia, in which the syrinx was so eccentric relative to the center of the spinal cord that at initial examination it appeared to be an exophytic extramedullary mass, in five of six patients with type 2 Arnold-Chiari malforma...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.183.1.1549680
更新日期:1992-04-01 00:00:00
abstract::Seven infants born at our institution between July 1979 and June 1982 had congenital diaphragmatic hernia (CDH). Four cases of CDH were correctly identified by fetal ultrasonography. Diagnosis relied upon the demonstration of abdominal organs within the thorax. During this period, no false positive diagnoses of CDH we...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.148.1.6856820
更新日期:1983-07-01 00:00:00
abstract:PURPOSE:To compare open-magnet magnetic resonance (MR) imaging performed with the patient sitting with dynamic closed-magnet MR imaging of the pelvic floor performed with the patient supine. MATERIALS AND METHODS:Thirty-eight patients underwent dynamic 1.5-T closed-magnet pelvic floor MR imaging while in the supine po...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2232010665
更新日期:2002-05-01 00:00:00
abstract::We describe a modification of a tracheostomy tube that allows treatment of carcinoma recurrence in the tracheal stoma using intracavitary radiation therapy. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.159.1.3952320
更新日期:1986-04-01 00:00:00
abstract:PURPOSE:To report population-based utilization rates and their variability across and within populations, geographic areas, and different payment systems for diagnostic radiology and radiation oncology procedures. MATERIALS AND METHODS:Aggregated claims data were obtained from four sources for up to nine radiologic mo...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.200.1.8657910
更新日期:1996-07-01 00:00:00
abstract::The accumulation of technetium-99m diethylenetriamine pentaacetic acid (Tc-99m DTPA) in benign soft-tissue neurofibromatosis tumors is reported. In a series of 16 patients with clinical stigmata of neurofibromatosis, 28 sites of abnormal soft-tissue localization of the isotope observed scintigraphically were documente...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.157.3.3933050
更新日期:1985-12-01 00:00:00