Abstract:
PURPOSE:To prospectively assess the effect of including or excluding endocardial trabeculae in left ventricular (LV) measurements and the reproducibility of these measurements at cine cardiovascular magnetic resonance (MR) imaging with true fast imaging with steady-state precession (FISP). MATERIALS AND METHODS:The study was approved by the local ethics committee, and each subject gave informed consent before participating. Twenty healthy subjects and 20 consecutive patients underwent 1.5-T cardiovascular MR imaging. Seven to 12 short-axis views encompassing the entire LV were acquired by using true FISP. Endocardial and epicardial contours were traced manually. The data sets in each patient were analyzed twice: with inclusion of endocardial trabeculae in the LV cavity volume and with exclusion of endocardial trabeculae from the cavity volume. On the basis of these two contour sets, the end-diastolic (ED) and end-systolic (ES) LV volumes, ejection fraction (EF), and LV mass were calculated. Additionally, interobserver and interexamination reproducibility was assessed by using Bland-Altman analysis. RESULTS:Compared with exclusion of trabeculae, inclusion of trabeculae in the LV cavity volume resulted in significantly larger ED and ES LV volumes (mean differences, 21 mL +/- 11 [standard deviation] and 19 mL +/- 33, respectively; P < .001) and lower EFs (mean difference, -2% +/- 2; P < .001). The calculated LV mass was significantly smaller with inclusion than with exclusion of trabeculae (mean difference, -21 g +/- 12; P < .001). All interobserver and interexamination limits of agreement based on inclusion of trabeculae, except those for EF measurements, were superior to those based on exclusion of trabeculae. At measurement reproducibility comparisons, differences in interobserver ED LV volume and LV mass and interexamination LV mass were statistically significant, favoring the inclusion of trabeculae in the LV cavity volume. CONCLUSION:Trabeculae significantly affect quantifications of LV volume and mass. The superior reproducibility of LV measurements with the inclusion of endocardial trabeculae in the cavity volume favors this tracing algorithm for clinical use.
journal_name
Radiologyjournal_title
Radiologyauthors
Papavassiliu T,Kühl HP,Schröder M,Süselbeck T,Bondarenko O,Böhm CK,Beek A,Hofman MM,van Rossum ACdoi
10.1148/radiol.2353040601subject
Has Abstractpub_date
2005-07-01 00:00:00pages
57-64issue
1eissn
0033-8419issn
1527-1315pii
2353040601journal_volume
236pub_type
杂志文章相关文献
RADIOLOGY文献大全abstract::The effect of nuclear magnetic resonance (NMR) imaging on six representative cardiac pacemakers was studied. The results indicate that the threshold for initiating the asynchronous mode of a pacemaker is 17 gauss. Radiofrequency levels are present in an NMR unit and may confuse or possibly inhibit demand pacemakers, a...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.147.1.6828720
更新日期:1983-04-01 00:00:00
abstract::Twenty-five rhesus monkeys were randomly assigned to one of five treatment schedules: 1. control group, no irradiation, 2. 60Co five times weekly, 3. 60Co twice weekly, 4. 16-MeVd leads to Be neutrons twice weekly, and 5. 50-MeVd leads to Be neutrons twice weekly. Although the acute reactions were similar in the four ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/117.1.185
更新日期:1975-10-01 00:00:00
abstract:PURPOSE:To present our experience with helical computed tomographic (CT) arteriography as the initial diagnostic examination in patients suspected to have focal arterial injuries of the proximal extremities. MATERIALS AND METHODS:During 19 months, 142 arterial segments in the proximal portions of the extremities of 13...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.218.1.r01ja13188
更新日期:2001-01-01 00:00:00
abstract::Sports-related muscle pain is frequent in both trained and untrained persons; however, its severity and significance may be difficult to assess clinically. The authors used magnetic resonance (MR) imaging to evaluate acute strains and delayed-onset muscle soreness in sedentary subjects and postmarathon myalgia in trai...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.172.3.2772190
更新日期:1989-09-01 00:00:00
abstract:PURPOSE:To investigate neuronal activations during processing of radiologic and nonradiologic images by experienced radiologists and nonradiologist subjects by using event-related functional magnetic resonance (MR) imaging. MATERIALS AND METHODS:Study was approved by local ethics committee, and informed consent was ob...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2363041370
更新日期:2005-09-01 00:00:00
abstract::Digital radiographs obtained with a CT scanner were evaluated as an alternative to conventional pelvimetry. Dosimetry studies demonstrated an absorbed radiation dose of 22 mrad for each digital radiograph, approximately 3% of the dose for comparable standard radiographs. Distance measurements were accurately made on d...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.143.3.7079500
更新日期:1982-06-01 00:00:00
abstract:PURPOSE:To identify current patterns and trends of computed tomographic (CT) screening, including geographic data, services provided, facility type, and demographic characteristics. MATERIALS AND METHODS:In March 2003, self-referred body imaging (SRBI) centers were identified by using the Internet. Data involving geog...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2332031964
更新日期:2004-11-01 00:00:00
abstract::High-resolution, real-time sonography of the rotator cuff was performed in 51 shoulders, and the results were correlated with findings obtained during subsequent surgery. Prospective sensitivity of sonography in detection of a tear was 100%; specificity, 75%; and accuracy, 92%. Retrospective estimation of tear size on...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.169.3.3055040
更新日期:1988-12-01 00:00:00
abstract:PURPOSE:To assess the existence of a mismatch between lesions on diffusion-weighted (DW) and perfusion-weighted (PW) magnetic resonance (MR) images obtained within 24 hours after onset of acute stroke and to use mismatch data and angiographic evidence of proximal arterial occlusion (PAO) to investigate whether the exis...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2503080811
更新日期:2009-03-01 00:00:00
abstract::Arthropathy is part of the protean manifestations of Behçet disease. Imaging findings reported thus far have been based on those of conventional radiography. Magnetic resonance imaging in two cases of Behçet disease with arthropathy demonstrated synovial thickening and effusion, as well as myositis manifested by high ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2262011982
更新日期:2003-02-01 00:00:00
abstract::Steeple-shaped shadows adjacent to the diaphragm are common in upper lobe collapse due to a variety of causes. They call attention to upper lobe collapse and should not be considered indicative of intrinsic lower lobe abnormality. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.134.3.7355230
更新日期:1980-03-01 00:00:00
abstract::Duplication of intrahepatic venous channels was observed in 9 of 13 children with congenital hepatic fibrosis and portal hypertension. Portal hypertension due to other causes was not associated with venous duplication. This anomaly may be a distinctive feature of congenital hepatic fibrosis with portal hypertension. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/122.2.427
更新日期:1977-02-01 00:00:00
abstract:PURPOSE:To determine the most accurate imaging modality for detection of silicone implant ruptures. MATERIALS AND METHODS:Forty single-lumen silicone implants were surgically placed in 20 rabbits. Each rabbit received one intact and one ruptured implant and was examined with mammography, magnetic resonance (MR) imagin...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.190.1.8259410
更新日期:1994-01-01 00:00:00
abstract:PURPOSE:To prospectively quantify tumor response or progression in patients with lung cancer by using thin-section computed tomography (CT) and a semiautomated algorithm to calculate tumor volume and other parameter values. MATERIALS AND METHODS:This HIPAA-compliant study was institutional review board approved; infor...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2413051887
更新日期:2006-12-01 00:00:00
abstract::In a study of 726 patients, xeroradiography of the thyroid using a modified oblique projection was found to be superior to conventional soft-tissue radiography in detecting calcification in thyroid tumors because of edge enhancement. This facilitated a diagnosis of carcinoma in 75% of 68 primary tumors and 55% of 33 r...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.141.2.7291570
更新日期:1981-11-01 00:00:00
abstract::In a patient with Paget disease, two of three lytic fronts ("blade-of-grass" lesions) healed according to radiologic criteria during intermittent diphosphonate therapy. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.134.3.7355210
更新日期:1980-03-01 00:00:00
abstract::An analysis of treatment response in 215 patients treated by percutaneous nephrostomy identified obstruction of the urinary tract, complicated by infection and sometimes gram-negative septicemia, as the single most important indication for this intervention. Percutaneous nephrostomy reduced the mortality from gram-neg...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.147.2.6836120
更新日期:1983-05-01 00:00:00
abstract:PURPOSE:To prospectively compare nonenhanced magnetic resonance (MR) imaging and ultrasonography (US) for the diagnosis of pediatric appendicitis. MATERIALS AND METHODS:This HIPAA-compliant study was approved by the institutional review board, and written informed consent was obtained from the patient's parent or guar...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.14132206
更新日期:2014-07-01 00:00:00
abstract::Transforaminal epidural steroid injections (TFESIs) are associated with rare but devastating neurologic complications. Every published case has been associated with a particulate steroid suspension, and the presumed but not proven mechanism is embolization and occlusion of end arterioles. Through an in vivo murine mod...
journal_title:Radiology
pub_type: 评论,杂志文章
doi:10.1148/radiol.2016160171
更新日期:2016-06-01 00:00:00
abstract::The National Electrical Manufacturers Association (NEMA) has established a new standard for x-ray tube focal-spot measurements using a focal-spot camera with a slit instead of a pinhole. Measurements from the slit focal-spot camera are compared and star resolution pattern techniques for 50 focal spots. In addition, me...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.165.1.3628780
更新日期:1987-10-01 00:00:00
abstract::Transrectal sonography of the normal prostate demonstrates a gland that has low-level homogeneous echoes. Benign and malignant prostatic disease causes disruption of this normal texture. A prospective study was performed to determine the ability of ultrasound to detect focal defects accurately. The specific histologic...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.149.1.6193560
更新日期:1983-10-01 00:00:00
abstract::An 8-F guiding catheter has been developed for use with coaxial angioplasty balloon catheters in angioplasty of the femoral artery from the contralateral approach when antegrade puncture of the ipsilateral femoral artery is not possible. The catheter may be used for angioplasty of the femoral artery bifurcation and th...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.177.2.2145610
更新日期:1990-11-01 00:00:00
abstract::Congenital arteriovenous malformations (AVMs) involving the pelvis or an extremity were occluded in 16 symptomatic patients, who subsequently underwent tailored embolotherapy. An additional 11 patients did not undergo embolization due to unfavorable vascular anatomy or lack of significant symptoms. Permanent occlusive...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.169.2.3175000
更新日期:1988-11-01 00:00:00
abstract:PURPOSE:To prospectively evaluate the accuracy of contrast material-enhanced magnetic resonance (MR) angiography in the evaluation of vascular invasion by bone and soft-tissue tumors, with surgery serving as the reference standard. MATERIALS AND METHODS:This study was approved by the regional ethics committee, and all...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2382041725
更新日期:2006-02-01 00:00:00
abstract::Fifty-five liver metastases in 21 patients were treated with interstitial laser photocoagulation (ILP). Tumors were irradiated with a neodymium yttrium aluminum garnet laser via optical fibers passed through 19-gauge needles inserted under ultrasound (US) guidance. Heating of the tumor was evident at real-time US as a...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.187.2.8475270
更新日期:1993-05-01 00:00:00
abstract::Ioglucomide, a new iodinated nonionic contrast medium directed primarily toward myelographic use, was subjected to an extensive toxicological examination in animals. In the majority of studies, ioglucomide was compared directly with metrizamide. In some respects, including freedom from production of arachnoiditis, iog...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.140.3.7280240
更新日期:1981-09-01 00:00:00
abstract:PURPOSE:To determine the ability to use computed tomography (CT) to predict invasion of adjacent nerves or vessels by oral cavity tumors. MATERIALS AND METHODS:Contrast material-enhanced CT scans and histopathologic reports were retrospectively reviewed in 48 patients (36 men, 12 women) aged 38-75 years who underwent ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.198.1.8539370
更新日期:1996-01-01 00:00:00
abstract::A new radiographic view of the osteoarthritic knee is presented, which appears to be useful in assessing the degree of cartilage loss in the medial and/or lateral femorotibial compartments. Its usefulness in comparison with other radiographic modalities is described. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.137.2.7433690
更新日期:1980-11-01 00:00:00
abstract:PURPOSE:To prospectively compare the accuracy of imaging with technetium-99m-labeled Fab' fragment of the anti-carcinoembryonic antigen antibody (CEA) IMMU-4 with that of computed tomography (CT) for the detection of pelvic recurrence of colorectal carcinoma. MATERIALS AND METHODS:In 61 patients, blinded interpretatio...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.197.3.7480740
更新日期:1995-12-01 00:00:00
abstract:PURPOSE:To determine the diagnostic efficacy of hard- and soft-copy computed radiographic (CR) images versus conventional screen-film images of the chest in the detection of subtle pulmonary abnormalities. MATERIALS AND METHODS:Twenty observes compared 87 hard-copy and soft-copy CR images with hard-copy screen-film im...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.201.1.8816520
更新日期:1996-10-01 00:00:00