Evaluation of four assay methods for determination of tobramycin in human serum.

Abstract:

:Four assay procedures for tobramycin in serum--enzyme immunoassay (I), substrate-labeled fluorescent immunoassay (II), radioimmunoassay (III), and bioassay (IV)--were compared and evaluated by replicate and analytical recovery studies. I and II were about 50% more precise than III and IV. II was substantially more nearly accurate than the other methods and also gave the best reproducibility (correlation coefficient 0.992 between-day). The least expensive method was IV. Ease of handling favored I and II. Overall, we find II to be the most acceptable procedure for use in the clinical laboratory.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Acton WJ,Van Duyn OM,Allen LV,Flournoy DJ

subject

Has Abstract

pub_date

1982-01-01 00:00:00

pages

177-80

issue

1

eissn

0009-9147

issn

1530-8561

journal_volume

28

pub_type

杂志文章
  • A modified radioimmunoassay for 1,25-dihydroxycholecalciferol.

    abstract::A radioimmunoassay for 1,25-dihydroxycholecalciferol which did not cross react with 1,25-dihydroxyergocalciferol is described. IgG fractions were prepared from the serum of rabbits that had been immunized with 1,25-dihydroxycholecalciferol-3-hemisuccinate coupled to bovine albumin. Radioligand binding by the IgG fract...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Gray TK,McAdoo T,Pool D,Lester GE,Williams ME,Jones G

    更新日期:1981-03-01 00:00:00

  • Interlaboratory/intermethod differences in functional sensitivity of immunometric assays of thyrotropin (TSH) and impact on reliability of measurement of subnormal concentrations of TSH.

    abstract::Clinically relevant interassay precision profiles for thyrotropin (thyroid-stimulating hormone; TSH) were constructed with human serum pools measured over 4-8 weeks by six immunometric assays, in at least two different reagent lots. Functional sensitivities (the concentration at which the interassay CV is < or = 20%) ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Spencer CA,Takeuchi M,Kazarosyan M,MacKenzie F,Beckett GJ,Wilkinson E

    更新日期:1995-03-01 00:00:00

  • Stable-isotope dilution liquid chromatography-electrospray injection tandem mass spectrometry method for fast, selective measurement of S-adenosylmethionine and S-adenosylhomocysteine in plasma.

    abstract:BACKGROUND:It has been postulated that changes in S-adenosylhomocysteine (AdoHcy), a potent inhibitor of transmethylation, provide a mechanism by which increased homocysteine causes its detrimental effects. We aimed to develop a rapid and sensitive method to measure AdoHcy and its precursor S-adenosylmethionine (AdoMet...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2004.046995

    authors: Gellekink H,van Oppenraaij-Emmerzaal D,van Rooij A,Struys EA,den Heijer M,Blom HJ

    更新日期:2005-08-01 00:00:00

  • Liquid chromatography-isotope dilution-mass spectrometry as a new basis for the reference measurement procedure for hemoglobin A1c determination.

    abstract:BACKGROUND:Standardization of hemoglobin (Hb)A(1c) measurements is a process of considerable interest for quality assurance in diabetes management. To contribute to continuous quality improvement and fulfillment of the requirements for reference measurement procedures according to the standards of the International Org...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.139477

    authors: Kaiser P,Akerboom T,Ohlendorf R,Reinauer H

    更新日期:2010-05-01 00:00:00

  • Quantitative nephelometric assay for determining myoglobin evaluated.

    abstract::A recently introduced automated nephelometric immunoassay involving shell/core particles for determination of myoglobin (Behringwerke) was evaluated with the BNA Nephelometer. Method precision was good: the intra-assay CV varied between 1.5% and 6.1%; with daily calibration, the interassay CV ranged between 1.5% and 7...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Delanghe JR,Chapelle JP,Vanderschueren SC

    更新日期:1990-09-01 00:00:00

  • Computerized multicuvette system for single substance and group analysis and for the chromatographic isolation and quantitation of compounds in complex mixtures.

    abstract::A new computer-interfaced system of general applicability in the clinical laboratory has been built. The system is constructed around a new type multicuvette. Quantitation is currently by spectrophotometry and is on-line, with use of a mini-computer with output going to an electrostatic printer/plotter. The system can...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Vestergaard P,Bachman A

    更新日期:1975-08-01 00:00:00

  • Quinidine-induced decrease of intracellular esterase activity in a hepatoma cell line.

    abstract::Using image-analyzing equipment, we measured the effect of quinidine on the activity of naphthol AS-D chloroacetate esterase, alpha-naphthyl butyrate esterase, alpha-naphthyl acetate esterase, and acid phosphatase in individual cells of a human Hep G2 hepatoma cell line. The impact of the drug on the morphology of the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Markovic OT,Young DS,Markovic NS

    更新日期:1988-03-01 00:00:00

  • Unpredictable fluctuations in transcutaneous pCO2 from capillary blood gas determinations.

    abstract::Transcutaneous pCO2 electrode response time was optimized by use of a new electrode filling solution composed of NaCl/NaHCO3 electrolyte buffer (100 and 20 mmol/L, respectively) in an equivolume mixture of glycerol and water. The 95% response time to a step change in pCO2 was 49.9 +/- 2.8 s (mean +/- SD) when there wa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kost GJ,Chow JL,Kenny M

    更新日期:1982-07-01 00:00:00

  • Automated creatine kinase-MB estimation by immuno-inhibition: a clinical evaluation.

    abstract::We detected the presence of creatine kinase (EC 2.7.3.2) MB isoenzyme (CK-MB) in serum by using an immunoinhibition technique to inactivate the creatine kinase isoenzyme of muscle origin (CK-MM). The GEMSAEC centrifugal analyzer is ideally suited for this procedure because it rapidly mixes reagents and has a throughpu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Delahunty TJ,Foreback CC

    更新日期:1980-04-01 00:00:00

  • On the use and computation of likelihood ratios in clinical chemistry.

    abstract::The clinical relevance of likelihood ratios (L-values) for revising the physician's diagnostic probabilities has been recognized. However, the calculation of L-values, particularly in the case of quantitative or mixed quantitative-binary test results, raises problems that have not yet been addressed. Based on a very g...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Albert A

    更新日期:1982-05-01 00:00:00

  • Rapid, simple, and sensitive immunoagglutination assay with SiO2 particles and quartz crystal microbalance for quantifying Schistosoma japonicum antibodies.

    abstract:BACKGROUND:The resurgence of the parasitic disease schistosomiasis calls for more efficient diagnostic tests. We developed a rapid, simple, portable, and sensitive immunoagglutination assay that uses SiO(2) particles and quartz crystal microbalance (QCM) for quantifying Schistosoma japonicum (Sj) antibodies (SjAb). ME...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.071555

    authors: Wang H,Zhang Y,Yan B,Liu L,Wang S,Shen G,Yu R

    更新日期:2006-11-01 00:00:00

  • A candidate reference method for uric acid in serum. II. Interlaboratory testing.

    abstract::We describe the interlaboratory testing of a candidate Reference Method (Part I) for uric acid in serum. The method is based on the ultrasound spectrophotometric quantitation of uric acid before and after incubation with uricase. A comprehensive investigation involving 12 laboratories was organized to document the tra...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Duncan P,Gochman N,Bayse D,Burnett R,Carey N,Carter R,Fellows WD,Garber C,Kessler G,McComb R,Miller W,Nast P,Ryan W,Schaffer R,Tejeda B,Vanderlinde R,Widdowson G

    更新日期:1982-02-01 00:00:00

  • Development of a rapid and sensitive immunofluorometric assay for glutathione S-transferase A.

    abstract:BACKGROUND:The short half-life of the alpha-class glutathione S-transferases (GSTAs) in plasma combined with their even distribution throughout the liver lobule suggests that they may be useful complements to the more traditionally used liver markers. However, the currently available assays for measuring GSTAs in biolo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dajani LK,Paus E,Warren DJ

    更新日期:2001-05-01 00:00:00

  • Ultraviolet fluorescence of human sera: I. Sources of characteristic differences in the ultraviolet fluorescence spectra of sera from normal and cancer-bearing humans.

    abstract::The ultraviolet fluorescence emission spectra of sera from apparently healthy persons and of sera from cancer patients frequently show significantly different curve shapes. A biparametric fluorescence method has been developed to use these deviations to detect patients with malignant diseases (Clin Chem 1986;32:1974-8...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hubmann MR,Leiner MJ,Schaur RJ

    更新日期:1990-11-01 00:00:00

  • Fully enzymatic method for determining 1,5-anhydro-D-glucitol in serum.

    abstract::We have developed a fully enzymatic method to measure 1,5 anhydro-D-glucitol (1,5-AG) in serum through use of pyranose oxidase (PROD: EC 1.1.3.10), glucokinase (EC 2.7.1.2), and an ATP-regenerating system. In a previous report (Clin Chem 1989;35:2039-43) the glucose interfering with the measurement of 1,5-AG was remov...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fukumura Y,Tajima S,Oshitani S,Ushijima Y,Kobayashi I,Hara F,Yamamoto S,Yabuuchi M

    更新日期:1994-11-01 00:00:00

  • Inhibitory effects of micronized fenofibrate on carotid atherosclerosis in patients with essential hypertension.

    abstract:BACKGROUND:The coexistence of hypertension and dyslipidemia synergistically increases the risk of cardiovascular events. We investigated the effect of the lipid-lowering agent micronized fenofibrate on inhibition of carotid atherosclerosis in patients with essential hypertension and mild hyperlipidemia. METHODS:We mea...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,随机对照试验

    doi:10.1373/clinchem.2006.074724

    authors: Zhu S,Su G,Meng QH

    更新日期:2006-11-01 00:00:00

  • Advances in the Treatment of Hemophilia: Implications for Laboratory Testing.

    abstract:BACKGROUND:Until recently, clinical laboratories have monitored hemophilia treatment by measuring coagulation factors before/after infusion of human-derived or recombinant factors. Substantial changes are expected in the near future based on new therapeutic approaches that have been or are being developed. CONTENT:Hem...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2017.284356

    authors: Tripodi A,Chantarangkul V,Novembrino C,Peyvandi F

    更新日期:2019-02-01 00:00:00

  • Direct determination of free thyroxin in undiluted serum by equilibrium dialysis/radioimmunoassay.

    abstract::We have designed a re-usable dialysis cell and a complex dialysis buffer, with which undiluted serum samples can be dialyzed with minimal changes in their serum matrix. Dialysate thyroxin (free T4) is then measured by a sensitive RIA for T4. The range of reportability was 2-128 ng/L, the normal range was 8-27 ng/L, an...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Nelson JC,Tomei RT

    更新日期:1988-09-01 00:00:00

  • Comparison between gradient gel electrophoresis and nuclear magnetic resonance spectroscopy in estimating coronary heart disease risk associated with LDL and HDL particle size.

    abstract:BACKGROUND:Gradient gel electrophoresis (GGE) and nuclear magnetic resonance (NMR) spectroscopy are both widely accepted methods for measuring LDL and HDL particle size. However, whether or not GGE- or NMR-measured LDL or HDL particle size predicts coronary heart disease (CHD) risk to a similar extent is currently unkn...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.140939

    authors: Arsenault BJ,Lemieux I,Després JP,Wareham NJ,Stroes ES,Kastelein JJ,Khaw KT,Boekholdt SM

    更新日期:2010-05-01 00:00:00

  • Production and certification of an enzyme reference material for gamma-glutamyltransferase (CRM 319). Part 2: Certification campaign.

    abstract::We describe the process of certification for a gamma-glutamyltransferase reference material (CRM no. 319). Fifteen laboratories participated to this interlaboratory evaluation. All steps of the measurements were controlled in an effort to locate potential sources of variations. In particular, the exclusion of some dat...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schiele F,Muller J,Colinet E,Siest G

    更新日期:1987-11-01 00:00:00

  • Contribution of CYP3A5 to the in vitro hepatic clearance of tacrolimus.

    abstract:BACKGROUND:Tacrolimus is metabolized predominantly to 13-O-demethyltacrolimus in the liver and intestine by cytochrome P450 3A (CYP3A). Patients with high concentrations of CYP3A5, a CYP3A isoenzyme polymorphically produced in these organs, require higher doses of tacrolimus, but the exact mechanism of this association...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.050047

    authors: Kamdem LK,Streit F,Zanger UM,Brockmöller J,Oellerich M,Armstrong VW,Wojnowski L

    更新日期:2005-08-01 00:00:00

  • Detection of inhibitors in reduced nicotinamide adenine dinucleotide by kinetic methods.

    abstract::Methods are described for detection of lactate dehydrogenase (LDH) inhibitors in preparations of reduced nicotinamide adenine dinucleotide. They are (a) comparison of values by kinetic methods with those measured for highly purified NADH and (b) examination of Lineweaver-Burk plots. Chromatographic inhomogeneities are...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Howell BF,Margolis S,Schaffer R

    更新日期:1976-10-01 00:00:00

  • Solid-phase enzyme immunoassay of terminal deoxynucleotidyl transferase evaluated.

    abstract::We evaluated a newly developed solid-phase immunoassay (EIA) of terminal deoxynucleotidyl transferase (TdT, EC 2.7.7.3) and compared it with the enzymatic assay of TdT involving DNA polymerase. We assessed the precision, performance characteristics, and clinical efficacy of the EIA procedure, using 249 specimens of pe...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fleisher M,Stankievic R,Schwartz D,Schwartz MK

    更新日期:1987-02-01 00:00:00

  • Diagnosis of acute myocardial infarction from two measurements of creatine kinase isoenzyme MB with use of nonparametric probability estimation.

    abstract::By using bivariate probability estimation for the diagnosis of acute myocardial infarction (AMI) we show how to overcome the difficulties encountered for patients whose clinical presentation is atypical and those encountered when multiple isoenzyme determinations are treated by univariate methods. We use the values fo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bernstein LH,Good IJ,Holtzman GI,Deaton ML,Babb J

    更新日期:1989-03-01 00:00:00

  • Metabolic relationship between urea and guanidino compounds as studied by automated fluorimetry of guanidino compounds in urine.

    abstract::In this automated system for assaying guanidino compounds, the compounds are resolved on an ion-exchange (Dowex 50) column, then reacted with phenanthrenequinone in alkaline solution. This mixture is then acidified and the resulting fluorescence is measured (lambda ex, 305 nm; lambda em, 395 nm). I applied the system ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Natelson S

    更新日期:1984-02-01 00:00:00

  • Simultaneous measurement of eight corticosteroids by liquid chromatography, and application of the procedure to diagnosis of congenital adrenal hyperplasia.

    abstract::We describe a liquid-chromatographic procedure for simultaneously determining eight steroids in serum. We used a Zorbax ODS column and a mobile phase of methanol/isopropanol/water (44/10/46, by vol), which well resolves the steroids cortisone, cortisol, corticosterone, 11-deoxycortisol, 11-deoxycorticosterone, androst...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wei JQ,Zhou XT,Wei JI

    更新日期:1987-08-01 00:00:00

  • High-throughput genotyping of thiopurine S-methyltransferase by denaturing HPLC.

    abstract:BACKGROUND:The thiopurine S:-methyltransferase (TPMT) genetic polymorphism has a significant clinical impact on the toxicity of thiopurine drugs, which are used in the treatment of leukemia and as immunosuppressants. To date, 10 mutant alleles are known that are associated with intermediate or low TPMT activity. To fac...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schaeffeler E,Lang T,Zanger UM,Eichelbaum M,Schwab M

    更新日期:2001-03-01 00:00:00

  • Evaluation of the lysosome-associated membrane protein LAMP-2 as a marker for lysosomal storage disorders.

    abstract::For many lysosomal storage disorders, presymptomatic detection, before the onset of irreversible pathology, will greatly improve the efficacy of current and proposed therapies. In the absence of a family history, presymptomatic detection can be achieved only by a comprehensive newborn screening program. Recently we re...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hua CT,Hopwood JJ,Carlsson SR,Harris RJ,Meikle PJ

    更新日期:1998-10-01 00:00:00

  • Anaphylaxis in the mouse--a model for using two-dimensional electroimmunodiffusion to study pathological changes in multiple serum proteins simultaneously.

    abstract::Two-dimensional electroimmunodiffusion is rarely used in clinical chemistry, because its potentialities are not yet widely appreciated. Studying mouse anaphylaxis, we observed with this technique certain striking short- and long-term pathologic changes in several important serum antigens, which aptly demonstrate its u...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Quintero S,Crowle AJ

    更新日期:1979-05-01 00:00:00

  • Up-dated catalogue of HeLa cell proteins: percentages and characteristics of the major cell polypeptides labeled with a mixture of 16 14C-labeled amino acids.

    abstract::A total of 1357 polypeptides [946 acidic (isoelectric focusing) and 411 basic (nonequilibrium pH-gradient electrophoresis)] from human HeLa cells have been separated and catalogued with use of high-resolution two-dimensional gel electrophoresis. Of these polypeptides, 1266 were detected by labeling cells with [35S]met...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bravo R,Celis JE

    更新日期:1982-04-01 00:00:00