[Lymphocytic hormonal receptors (author's transl)].

Abstract:

:The recent development of technics of specific fixation using radio isotope-labelled tracer elements permits the demonstration of various types of receptors at the level of the lymphocyte membrane. Thus a new route is open in the understanding of the biochemical mechanisms controlling the physiology of the lymphocyte and its role in the immune response. Furthermore these lymphocyte receptors may represent to some degree, the state of the rarely accessible tissue receptors in human pathology. However, at present, the practical interest is limited by the absence of standardisation of technics and the heterogeneity of athe lymphocyte population studied.

journal_name

Ann Biol Clin (Paris)

authors

Arrang JM,Bidart JM

subject

Has Abstract

pub_date

1980-01-01 00:00:00

pages

283-92

issue

5

eissn

0003-3898

issn

1950-6112

journal_volume

38

pub_type

杂志文章,评审
  • Serum transcortin levels in patients with chronic hemodialysis.

    abstract::Patients with renal insufficiency who are hemodialyzed 3 times a week either through a cuprophane membrane or through a polyacrylonitrile (PAN) membrane have the same transcortin and cortisol levels as patients with renal insufficiency who are not dialyzed. Moreover, hemodialysis did not influence acutely the latter t...

    journal_title:Annales de biologie clinique

    pub_type: 杂志文章

    doi:

    authors: De Moor P,Faict D,Verberckmoes R

    更新日期:1985-01-01 00:00:00

  • [Plasma and intra-erythrocytic concentrations of copper and zinc in uremic patients treated by periodic hemodialysis].

    abstract::In this report, the authors have studied the plasma and red blood cell concentrations of both zinc and copper in 90 uremic patients treated by intermittent hemodialysis. They found that plasmatic and erythrocytic levels of zinc together with the copper red blood cell concentrations determined before and after the hemo...

    journal_title:Annales de biologie clinique

    pub_type: 杂志文章,评审

    doi:

    authors: Agenet C,Brugère CC,Reynier JP

    更新日期:1989-01-01 00:00:00

  • [Determination of serum or plasma alpha-tocopherol by high performance liquid chromatography: optimization of operative models].

    abstract::A previous multicentric study set up by the Société française de biologie clinique has emphasized the usefulness of a standardized procedure for the determination by high performance liquid chromatography of alpha-tocopherol in serum or plasma. In our study, we have tested every step of the different published procedu...

    journal_title:Annales de biologie clinique

    pub_type: 杂志文章,评审

    doi:

    authors: Jezequel-Cuer M,Le Moël G,Mounié J,Peynet J,Le Bizec C,Vernet MH,Artur Y,Laschi-Loquerie A,Troupel S

    更新日期:1995-01-01 00:00:00

  • [Comparison of different methods of hepatitis C virus genotyping].

    abstract::In order to introduce the approach of HCV genotyping in our laboratory, a comparative study of 3 molecular and 1 serological methods, was conducted on 62 HCV RNA positive sera. The molecular genotyping methods target the 5'untranslated (UTR) region of the virus genome and are based on an amplification of the viral gen...

    journal_title:Annales de biologie clinique

    pub_type: 杂志文章

    doi:

    authors: Djebbi A,Sadraoui A,Triki H

    更新日期:2003-11-01 00:00:00

  • [Diagnosis of type III hyperlipoproteinemia: contribution of an air-driven ultracentrifuge associated with an original tube-slicer (author's transl].

    abstract::Diagnosis of type III hyperlipoproteinemia requires preparative ultracentrifugation in order to measure the cholesterol/triglyceride molar ratio into isolated d less than 1.006 lipoproteins. The authors describe an ultracentrifugation micromethod which needs 600 microliter of serum and can be completed within three ho...

    journal_title:Annales de biologie clinique

    pub_type: 杂志文章

    doi:

    authors: Moulin S,Dewailly P,Sezille G,Fruchart JC

    更新日期:1979-01-01 00:00:00

  • [Determination of plasma creatinine with centrifugal analyser].

    abstract::An automated kinetic method to determine creatinine in plasma with Jaffé reaction (alkaline picrate reagent) using a Gemsaec analyser is studied in order to argue the precision and the accuracy. The analysis of the reaction rate of a primar standard solution and of different plasmas suggests that a rapid measure is re...

    journal_title:Annales de biologie clinique

    pub_type: 杂志文章

    doi:

    authors: Klumpp T,Férard G

    更新日期:1977-01-01 00:00:00

  • [Plasma assay of haloperidol by high performance liquid chromatography].

    abstract::Haloperidol is extracted with hexane-isoamyl alcohol in the presence of two internal standards, chlorohaloperidol and spiroperidol. For chromatographic separation, a C18 reversed-phase column and a mobile phase of acetonitrile/methanol/phosphate buffer are used. Detection is by UV absorption spectrophotometry at 245 n...

    journal_title:Annales de biologie clinique

    pub_type: 杂志文章

    doi:

    authors: Hequet D,Jarry C,Rouquette C,Brachet-Liermain A

    更新日期:1985-01-01 00:00:00

  • [Evaluation of HBA1C measurement on Architect CI8200 (Abbott Diagnostic). Comparison with HPLC D-10 Bio-Rad assay].

    abstract::The aim of this study is to present an evaluation of HbA(1c) Assay on Architect CI8200 (Abbott Diagnostic). The measurement includes Hb assay by colorimetry and HbA(1c) by immunoturbidimetry. The percentage of HbA(1c) is the report HbA(1c)/complete Hb with a conversion coefficient. Repetability (n = 30; CV: 1.15-1.91%...

    journal_title:Annales de biologie clinique

    pub_type: 杂志文章

    doi:10.1684/abc.2009.0301

    authors: Beaune G,Ducruet J,Jund J,Favre S

    更新日期:2009-01-01 00:00:00

  • [Analytical validation of a chromatographic method dedicated to search and identify natural and semi-synthetic opiates].

    abstract::The identification of a product absorbed by an opiate consumer is sometimes problematic since there is no specific biomarker for all molecules. We developed an ultra-high pressure liquid chromatography coupled to tandem mass spectrometry technique which allows the identification and the quantification of 25 opiates in...

    journal_title:Annales de biologie clinique

    pub_type: 杂志文章

    doi:10.1684/abc.2014.0944

    authors: Dubois N,Counerotte S,Goffin E,Pirotte B,Charlier C

    更新日期:2014-03-01 00:00:00

  • [Measurement of salivary cortisol with four commercial kits].

    abstract::Salivary cortisol was determined with four commercially available immunoassays: one enzyme-immunoassay (Cortisol Biotrol), two fluoro-immunoassays (TDX, Abbott; Stratus, Baxter) and one radioimmunoassay (Coat-A-Count, Behring). In order to improve the sensitivity of these immunoassays, it was necessary to increase sam...

    journal_title:Annales de biologie clinique

    pub_type: 杂志文章

    doi:

    authors: Nahoul K,Patricot MC,Bressot N,Penes MC,Revol A

    更新日期:1996-01-01 00:00:00

  • [Levels of manganese in biological media: value, samplings, physiopathological variations. Bibliographic review].

    abstract::The great diversity of methods for manganese analysis in biological materials (serum, plasma, whole blood, urine, spinal fluid and hair) reveals the difficulty in measuring extremely small quantities of this element. An examination of these methods demonstrate that the most used one is flameless atomic absorption spec...

    journal_title:Annales de biologie clinique

    pub_type: 杂志文章,评审

    doi:

    authors: Baruthio F,Guillard O,Arnaud J,Pierre F,Zawislak R

    更新日期:1988-01-01 00:00:00

  • [Glycated hemoglobin: assay methods and problems of standardization].

    abstract::Glycated hemoglobin can be assayed by methods using different principles, whose performances vary and are difficult to control. The most widely used techniques measure either specifically glycated A1c hemoglobin (HbA1c) or total glycated hemoglobin. They are reviewed in detail in this paper and standardization problem...

    journal_title:Annales de biologie clinique

    pub_type: 杂志文章,评审

    doi:

    authors: Gillery P,Guillemin C,Delpech M

    更新日期:1994-01-01 00:00:00

  • Potential role of the "NADPH oxidases" (NOX/DUOX) family in cystic fibrosis.

    abstract::Cystic fibrosis (CF), is the most common life-shortening autosomal recessive disorder in Caucasians. It is caused by mutations in a single gene on the long arm of chromosome 7 that encodes the cystic fibrosis transmembrane conductance regulator (CFTR) protein. CF is characterized by abnormal Na+ and Cl- ion transport ...

    journal_title:Annales de biologie clinique

    pub_type: 杂志文章,评审

    doi:10.1684/abc.2008.0285

    authors: Pongnimitprasert N,El-Benna J,Foglietti MJ,Gougerot-Pocidalo MA,Bernard M,Braut-Boucher F

    更新日期:2008-11-01 00:00:00

  • [SFBC guidelines on critical care testing].

    abstract::SFBC working group on critical care testing describes in this paper guideline for the management of laboratory medicine examination process in emergency conditions. After a summary on French standards and regulations, the critical care testing perimeter and definitions of stat levels are presented in different context...

    journal_title:Annales de biologie clinique

    pub_type: 杂志文章,实务指引

    doi:10.1684/abc.2015.1113

    authors: Vaubourdolle M,Alvarez JC,Barbé F,Beaudeux JL,Boissier É,Caillon H,Chatron P,Joly-Guillou ML,Mailloux A

    更新日期:2016-03-01 00:00:00

  • [Use of leukocytes labelled with 99m Technetium sulfide colloids for the detection of experimental aseptic inflammatory foci].

    abstract::The authors propose a technique of labelling of leukocytes based on the phagocytic power of these cells with regard to sulphide particles in the colloidal state labelled with 90mmTc. These labelled leukocytes maintain their normal function and can be detected in the inflammatory foci created in experimental animals in...

    journal_title:Annales de biologie clinique

    pub_type: 杂志文章

    doi:

    authors: Auvergnat JC,Simon J,Le Net R,Guiraud R,Armengaud M

    更新日期:1975-01-01 00:00:00

  • [Biermer's disease and autoimmune hemolytic anemia].

    abstract::Biermer's disease is an autoimmune atrophic gastritis of the fundus predominantly responsible for a malabsorption of vitamin B12. Despite its association with several autoimmune disorders, few observations have reported an association with autoimmune hemolytic anemia (AIHA). We report a case of Biermer's disease assoc...

    journal_title:Annales de biologie clinique

    pub_type: 杂志文章

    doi:10.1684/abc.2012.0713

    authors: Nafil H,Tazi I,Mahmal L

    更新日期:2012-07-01 00:00:00

  • [Determination of plasma progesterone. Comparison of immunochemical luminescence (LIA) and radioimmunoassay (RIA)].

    abstract::The authors describe an immunoassay technique of serum progesterone using a chemiluminescent tracer (LIA): progesterone aminobutylethylisoluminol 11-a-hemisuccinate (P-ABEI). The intrinsic characteristics of this technique were studied. The progesterone concentrations of 62 serum samples were simultaneously titrated u...

    journal_title:Annales de biologie clinique

    pub_type: 杂志文章

    doi:

    authors: Guilloteau D,Petat E,Besnard JC

    更新日期:1988-01-01 00:00:00

  • [Radioimmunologic assay of alpha-fetoprotein in various normal and pathological conditions].

    abstract::AFP can be measured by radioimmunoassay in 52 hours using an incubation at 18 degrees C for 48 hours and the double antibody solid phase method to separate the free labelled AFP from the labelled AFP bound to the antibodies. In these conditions, the sensitivity and precision of the assay are very satisfactory and the ...

    journal_title:Annales de biologie clinique

    pub_type: 杂志文章

    doi:

    authors: Franchimont P,Zangerle PF,Debruche ML,Proyard J,Simon M,Gaspard U

    更新日期:1975-01-01 00:00:00

  • [Use of the API 20E system for rapid identification of Enterobacteriaceae (six hours) (author's transl)].

    abstract::The authors propose a modification of the method of use of the API 20E system permitting more rapid identification of Enterobacteriaceae within six hours (3 hours preculture and 3 hours incubation on an API 20E plate) it was possible to identify correctly 67% of 192 strains studied at species level and 75.5% studied a...

    journal_title:Annales de biologie clinique

    pub_type: 杂志文章

    doi:

    authors: Pinon G,Loulergue J,Quentin R,Darchis JP,Prieur D,Vargues R

    更新日期:1979-01-01 00:00:00

  • [High risk of strongyloïdes hyperinfection in a patient with sarcoidosis].

    abstract::Strongyloïdes stercoralis infection is a polymorphic and non specific clinical presentation. Often asymptomatic, it can be not seen. However, in patients with immunodeficiency, high parasite load can be observed, consequence of self-infestation cycle, and can spread throughout the body. This presentation of malignant ...

    journal_title:Annales de biologie clinique

    pub_type: 杂志文章

    doi:10.1684/abc.2013.0809

    authors: Perez P,Debourgogne A,Valloton T,Nani A,Barraud H,Machouart M

    更新日期:2013-03-01 00:00:00

  • [Microspheres, nanospheres and flow cytometry: from cellular to molecular analysis].

    abstract::Micro- and nanospheres are tightly associated with the development of flow cytometry. They are indispensable tools to optimize diffraction and fluorescence signals as well as for fluorescence calibration and cellular purification (magnetic micro- and nanospheres). They are also usefull to evaluate phagocytosis and to ...

    journal_title:Annales de biologie clinique

    pub_type: 杂志文章,评审

    doi:

    authors: Lizard G,Monier S,Prunet C,Duvillard L,Gambert P

    更新日期:2004-01-01 00:00:00

  • [Analytical performances of SPAPLUS® turbidimeter for the dosage of immunoglobulins and beta-2 microglobulin in serum].

    abstract::We evaluated the analytical performances of the SPAPLUS(®) immunoturbidimeter assays manufactured by The Binding Site(®) for the quantification of thirteen immunological parameters in serum: IgG, IgA, IgM and IgD immunoglobulins, IgG subclasses (1 to 4), IgA subclasses (1 and 2), beta-2 microglobulin, free light chain...

    journal_title:Annales de biologie clinique

    pub_type: 杂志文章

    doi:10.1684/abc.2014.0974

    authors: Thevenet I,Benat C,Chauzeix J,Blancher A,Puissant-Lubrano B

    更新日期:2014-07-01 00:00:00

  • [Macroprolactin detection: a new approach].

    abstract::Macroprolactin is a complex of prolactin with immunoglobulins (IgG) that has limited or no biological activity in vivo. Immunoassays for prolactin have variable reactivity with macroprolactin. Therefore the presence of macroprolactin should be considered in the differential diagnosis of hyperprolactinemia. We compared...

    journal_title:Annales de biologie clinique

    pub_type: 杂志文章

    doi:

    authors: Sapin R,Gasser F,Fischbach E,Grucker D

    更新日期:2000-11-01 00:00:00

  • [Erythrocyte ferritin].

    abstract::Red cell ferritin is a residue of erythroblast ferritin. It reflects the balance between the iron supply to the erythroid marrow and the need for haemoglobin synthesis. Erythrocyte ferritin can be measured in haemolysates after discarding plasma and leucocytes by different methods. The decrease in erythrocyte ferritin...

    journal_title:Annales de biologie clinique

    pub_type: 杂志文章,评审

    doi:

    authors: Guillemin C,Revenant MC,Vernet M,Dezier JF,Charlier C,Paris M,Pressac M

    更新日期:1993-01-01 00:00:00

  • [Thyroxine (T4) and tri-iodothyronine (T3) determinations: techniques and value in the assessment of thyroid function].

    abstract::Hormonal production of the thyroid gland is constituted of thyroxine or T4 (80%) and triiodothyronine or T3 (20%). In the circulation, whole T4 originates from thyroid secretion but most of T3 (80%) is produced extrathyroidally from T4 deiodination. Conversion of T4 to T3 may be influenced by various conditions and ci...

    journal_title:Annales de biologie clinique

    pub_type: 杂志文章,评审

    doi:

    authors: Sapin R,Schlienger JL

    更新日期:2003-07-01 00:00:00

  • Proteinuria prescription in 2019.

    abstract::Today, medical prescriptions of proteinuria or albuminuria, which are depending on medical status of patients, still depend on doctors. Indeed, according to their medical specialty or to the recommendations they are following, they could prescribe either proteinuria or albuminuria. The consequences are practical for l...

    journal_title:Annales de biologie clinique

    pub_type: 杂志文章

    doi:10.1684/abc.2019.1412

    authors: Perrier F,Piéroni L,groupe de travail SFBC, SFNDT, SNP.

    更新日期:2019-02-01 00:00:00

  • [Identification of HLA B27 antigen by flow cytometry].

    abstract::Cytofluorograph analysis after immunofluorescence with monoclonal antibodies can be useful for various antigens identification on the surface of cell membrane. This technic is described for antigen HLA B27 identification. This HLA antigen is known indeed to be linked to rhumatismal diseases. The fluorescence histogram...

    journal_title:Annales de biologie clinique

    pub_type: 杂志文章

    doi:

    authors: Fizet D,Hitte C,Ferrer AM,Vezon G

    更新日期:1989-01-01 00:00:00

  • [Assay of cardiac troponin T on Elecsys 2010: comparison with cardiac troponin I].

    abstract::Cardiac troponin T (troponin Tc) of second generation has been measured on the Boehringer Elecsys 2010 analyzer. Cardiac specificity has been studied in patients presenting a rhabdomyolysis syndrome and the results compared with those obtained for cardiac troponin I (troponin Ic) measured on the Dade-Behring Stratus a...

    journal_title:Annales de biologie clinique

    pub_type: 杂志文章

    doi:

    authors: Cauliez B,Hue G,Lavoinne A

    更新日期:1998-11-01 00:00:00

  • [Physiopathology of rheumatoid polyarthritis].

    abstract::Rheumatoid arthritis is the most common and most severe form of inflammatory arthritis. Its exact aetiology remains unknown but the combination of various risk factors is involved. Two non mutually exclusive concepts have been suggested: one based on the primary contribution of T cells and the other on that of mesench...

    journal_title:Annales de biologie clinique

    pub_type: 杂志文章,评审

    doi:

    authors: Miossec P

    更新日期:1997-07-01 00:00:00

  • [Comparative study of G8 glycated haemoglobin testing system and the Integra 800 immunoassay].

    abstract::We compared the results of two methods of measurement of HbA(1c) before replacing the current method on Integra 800 by the HPLC method on an apparatus recently put on the market, the G8. The comparative study of the results for 119 patients was carried out. The reproducibility obtained with the G8 method is good with ...

    journal_title:Annales de biologie clinique

    pub_type: 杂志文章

    doi:10.1684/abc.2010.0420

    authors: Szymanowicz A,Neyron MJ

    更新日期:2010-03-01 00:00:00