Abstract:
PURPOSE:To prospectively evaluate the learning curves and reading times of inexperienced readers who used the virtual dissection reading method for retrospective computed tomographic (CT) colonography data sets, with and without concurrent computer-aided detection (CAD). MATERIALS AND METHODS:An Institutional Review Board approved this study; informed consent was waived. Four radiologists without experience in CT colonography evaluated 100 optical colonoscopy-proved data sets of 100 patients (49 men, 51 women; mean age, 59 years +/- 13 [standard deviation]; range, 21-85 years) by using the virtual dissection reading method. Two readers used concurrent CAD. Data sets were read during five consecutive 1-day sessions (20 data sets per session). Polyp detection and false-positive rates, receiver operating characteristics (ROCs), and reading times were calculated for individual, CAD group, and non-CAD group readings. Diagnostic values were compared by calculating the 95% confidence intervals (CIs) around the relative risk. Areas under ROC curves (AUCs) (Hanley and McNeil for paired analysis and z statistics for unpaired analysis) and reading times (Wilcoxon signed rank test) were compared across the sessions, within each session and for the whole study. RESULTS:The range of detection rates was 79 of 111 (.71 [95% CI: .61, .79]) to 91 of 111 (.82 [95% CI: .73, .88]). The range of false-positive rates was 17 of 111 (.15 [95% CI: .09, .23]) to 22 of 111 (.20 [95% CI: .12, .28]). All readers' AUCs rose from session 1 to session 4; this rise was significant (P < .05) for the non-CAD group. Only during session 1 was the CAD group AUC (.83) higher than the non-CAD group AUC (.54) (P < .05). Comparison of CAD and non-CAD reading times showed no significant difference for the whole study or during each session (P > .05). CONCLUSION:The virtual dissection reading technique allows short learning curves, which may be improved by the concurrent use of CAD, without significant effect on average reading time.
journal_name
Radiologyjournal_title
Radiologyauthors
Hock D,Ouhadi R,Materne R,Aouchria AS,Mancini I,Broussaud T,Magotteaux P,Nchimi Adoi
10.1148/radiol.2482070895subject
Has Abstractpub_date
2008-09-01 00:00:00pages
860-8issue
3eissn
0033-8419issn
1527-1315pii
248/3/860journal_volume
248pub_type
杂志文章相关文献
RADIOLOGY文献大全abstract::Purpose To assess subspecialty practice characteristics of the U.S. radiologist workforce. Materials and Methods This study used the Medicare Physician and Other Supplier Public Use File and did not constitute human subject research. The authors identified 33 090 radiologists who billed for professional services betwe...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2017171684
更新日期:2018-03-01 00:00:00
abstract::Purpose To compare PET/MR hypoperfusion and hypometabolism in patients with Alzheimer disease (AD) and mild cognitive impairment (MCI) compared with healthy control (HC) participants. Materials and Methods Maps of cerebral blood flow (CBF; pulsed arterial spin-labeling [ASL] MRI), glucose metabolism (fluorine 18 [18F]...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2018170575
更新日期:2018-07-01 00:00:00
abstract::From 1981 to 1986, 23 patients (24 hips) were treated with single-dose irradiation after hip surgery in an attempt to prevent heterotopic bone formation. All patients were at high risk for the development of heterotopic ossification because of the presence of heterotopic bone in either hip secondary to trauma or previ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.168.3.3136510
更新日期:1988-09-01 00:00:00
abstract::The authors retrospectively evaluated 12 patients with congenital (neonatal) neuroblastoma to assess the utility of newer imaging modalities. Findings at prenatal ultrasound (US), performed in four patients, were nonspecific (hydramnios and hydrops fetalis) in two and consistent with a suprarenal mass (one solid, one ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.175.2.2183280
更新日期:1990-05-01 00:00:00
abstract::The "comet tail" is a well-known ultrasound artifact that appears as a series of parallel bands radiating from a source. This artifact was observed in the gallbladder lumen in eight of 10 patients after extracorporeal shock wave lithotripsy of radiolucent calculi. To investigate the cause of the comet tail artifact, c...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.177.1.2204960
更新日期:1990-10-01 00:00:00
abstract::A case of a 19-year-old woman with generalized neurofibromatosis and hypertension due to left main renal artery mesodermal dysplasia is presented. Renal artery stenosis was effectively treated with percutaneous transluminal angioplasty. The relevant literature is also reviewed. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.139.3.6785820
更新日期:1981-06-01 00:00:00
abstract:PURPOSE:To determine the utility of computed tomographic (CT) enteroclysis for characterization of the status of the anastomotic site in patients with Crohn disease who had previously undergone ileocolic resection. MATERIALS AND METHODS:Written informed consent was prospectively obtained from all patients, and the ins...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.09091165
更新日期:2010-03-01 00:00:00
abstract::Eight male heart transplant recipients underwent contrast material-enhanced electron-beam computed tomographic angiography. Coronary artery diameters measured with fixed thresholds and adaptive line density profile (LDP) methods were calculated relative to findings at quantitative coronary angiography. Variation with ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2261011211
更新日期:2003-01-01 00:00:00
abstract::Tisseel, a fibrin sealant not approved for use in the United States, was tested in abdominal fistulas and sinuses (13 patients) and interventional biliary procedures (11 patients). The two components of Tisseel were introduced via a double-lumen catheter and formed a fibrin gel at the point of contact. Tracts were sea...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.196.2.7617880
更新日期:1995-08-01 00:00:00
abstract::A previous study determined the normal values and upper limits of liver size, as measured by the longitudinal and sagittal diameters in the midclavicular line and the midline. The present study was performed to determine which of the four sonographic diameters best differentiates between patients who have liver diseas...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.153.2.6385110
更新日期:1984-11-01 00:00:00
abstract::A new nonionic dimeric contrast medium (CM), iodixanol, was intravenously administered to 40 healthy male volunteers in doses of 0.3-1.2 g of iodine per kilogram of body weight, nonionic monomeric iopamidol and iopentol were administered to 20 others, and the renal effects were studied up to 120 hours after administra...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.182.2.1732960
更新日期:1992-02-01 00:00:00
abstract::Twenty-three consecutive patients with Waldenström macroglobulinemia were studied with magnetic resonance (MR) imaging of the spine and computed tomography (CT) of the abdomen and pelvis. MR imaging studies included sagittal T1-weighted and gradient-recalled-echo sequences performed with and without contrast material ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.188.3.8351330
更新日期:1993-09-01 00:00:00
abstract::In hepatic tumors seen in children, treatment and prognosis differ from tumor to tumor and thus accurate determination of their extent and characteristics is important. Evaluation by gray scale ultrasonography, radionuclide imaging and angiography has produced definable characteristics for the various tumor types and ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/124.2.451
更新日期:1977-08-01 00:00:00
abstract::Clinical, angiographic, scintigraphic and pathologic observations in myocardial contusion were correlated. Radionuclide imaging of the injured heart with 99mTc-Sn-polyphosphate provides an accurate diagnosis in acute, even mild, myocardial contusion. The study can be carried out without danger to the critically ill pa...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/116.3.679
更新日期:1975-09-01 00:00:00
abstract::Fine-needle aspiration (FNA) of normal breast tissue or benign lesions can cause changes that suggest malignancy at ultrasound (US) examination. Serial US studies showed that three of 17 patients developed signs mimicking malignancy following FNA of palpable breast lumps. A second group of 14 patients had US signs of ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.185.3.1438750
更新日期:1992-12-01 00:00:00
abstract:PURPOSE:To retrospectively evaluate the sensitivity of computer-aided detection (CAD) in depicting ductal carcinoma in situ (DCIS) on screening mammograms by using biopsy proved lesion location as the reference standard. MATERIALS AND METHODS:Institutional review board approval was obtained, with a waiver of patient i...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2413051366
更新日期:2006-12-01 00:00:00
abstract::Adult respiratory distress syndrome (ARDS) from overdose of tricyclic antidepressants (TCA) has been reported but is not well known. During a 1-year period, 81 patients with serious overdose from tranquilizers and other psychotropic drugs were examined. TCA alone induced overdose in 30 patients or were combined with o...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.170.3.2916020
更新日期:1989-03-01 00:00:00
abstract::Computed tomography of the brain was used in evaluating demented and nondemented elderly people. The incidence of convulutional atrophy and ventricular enlargement correlated well with pathologic and pneumoencephalographic examination of a similar population. Computed tomography also showed certain instances of dement...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/116.1.85
更新日期:1975-07-01 00:00:00
abstract::Though the advent of computed tomography has improved the detection of posterior fossa lesions, there are times when it can not be used to differentiate between an intra- and extraaxial lesion, particularly when the mass is anteriorly located. Base view angiography can be used to make this distinction, accurately loca...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/124.1.157
更新日期:1977-07-01 00:00:00
abstract::Current management of osteoarthritis (OA) is primarily focused on symptom control. Intra-articular corticosteroid (IACS) injections are often used for pain management of hip and knee OA in patients who have not responded to oral or topical analgesics. Recent case series suggested that negative structural outcomes incl...
journal_title:Radiology
pub_type: 杂志文章,评审
doi:10.1148/radiol.2020200771
更新日期:2020-12-01 00:00:00
abstract::The primary disadvantage of hard-wired data systems for use in nuclear medicine is the fact that that the data contained in the memory bank are not accessible to the user and often must be processed mathematically before they can be employed in interpretation, particularly in dynamic studies. The authors describe a re...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/118.1.225
更新日期:1976-01-01 00:00:00
abstract:PURPOSE:To test three-dimensional (3D), navigator-echo magnetic resonance (MR) coronary angiography in detecting stenoses of the coronary arteries. MATERIALS AND METHODS:Forty-two patients (age range, 50-79 years) underwent MR coronary angiography (1.5 T). A navigator-echo sequence was used. Two or three 15% overlappe...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.214.3.r00mr01808
更新日期:2000-03-01 00:00:00
abstract::As with other musculoskeletal joints, elbow ultrasonography (US) depends on the examination technique. Deep knowledge of the relevant anatomy, such as the bone surface anatomy, tendon orientation, nerves, and vessels, is crucial for diagnosis. It is important to be aware of the primary imaging pitfalls related to US t...
journal_title:Radiology
pub_type: 杂志文章,评审
doi:10.1148/radiol.2015141950
更新日期:2015-06-01 00:00:00
abstract:PURPOSE:To retrospectively evaluate the technical success, safety, and outcomes of radiologically guided retrograde percutaneous gastrostomy and gastrojejunostomy tube placements in terms of weight gain and growth in children with gastroschisis, omphalocele, and/or congenital diaphragmatic hernia (CDH). MATERIALS AND ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2481061193
更新日期:2008-07-01 00:00:00
abstract:PURPOSE:To assess the ability of an extravasation detection accessory (EDA) to detect clinically important (> or = 10 mL) extravascular injection of iodinated contrast material delivered with an automated power injector. MATERIALS AND METHODS:Five hundred patients referred for contrast material-enhanced body computed ...
journal_title:Radiology
pub_type: 杂志文章,多中心研究
doi:10.1148/radiology.212.2.r99au14431
更新日期:1999-08-01 00:00:00
abstract::Deshpande et al (1) have shown that P-selectin-targeted microbubbles (MBs) can be used to monitor the expression of this molecule as a marker of inflammation in a murine model of inflammatory bowel disease (IBD). If these results can be reproduced in future clinical trials, contrast material–enhanced ultrasound (US) o...
journal_title:Radiology
pub_type: 评论,杂志文章
doi:10.1148/radiol.11112145
更新日期:2012-01-01 00:00:00
abstract:PURPOSE:To determine the diagnostic accuracy of ultrasonographically (US) and stereotactically guided fine-needle aspiration biopsy (FNAB) in the diagnosis of nonpalpable breast lesions. MATERIALS AND METHODS:At 18 institutions, 442 women who underwent 22-25-gauge imaging-guided FNAB were enrolled. Definitive surgical...
journal_title:Radiology
pub_type: 临床试验,杂志文章,多中心研究,随机对照试验
doi:10.1148/radiology.219.3.r01jn28785
更新日期:2001-06-01 00:00:00
abstract:PURPOSE:To compare the performance of apparent diffusion coefficient (ADC) measurement obtained with diffusion-weighted (DW) magnetic resonance (MR) imaging in the characterization of non-fat-containing T1 hyperintense renal lesions with that of contrast material-enhanced MR imaging, with histopathologic analysis and f...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2513080724
更新日期:2009-06-01 00:00:00
abstract::In a series of nine stereotaxic large-core biopsies of calcifications, radiography of the specimen was used to ensure that appropriate tissue was removed. In eight cases, calcifications were evident at radiography as well as at histologic evaluation. Four cases were malignant and four were benign, and in one case in w...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.188.2.8327720
更新日期:1993-08-01 00:00:00
abstract::Treatment of complex intracranial aneurysms by means of interventional neurovascular techniques is now being performed with a newly developed silicone detachable-microballoon device. The balloon is composed of unique silicone elastomers that are extremely soft and malleable. It therefore conforms to the blood vessel l...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.174.3.2305050
更新日期:1990-03-01 00:00:00