Abstract:
PURPOSE:To determine the utility of computed tomographic (CT) enteroclysis for characterization of the status of the anastomotic site in patients with Crohn disease who had previously undergone ileocolic resection. MATERIALS AND METHODS:Written informed consent was prospectively obtained from all patients, and the institutional review board approved the study protocol. CT enteroclysis findings in 40 patients with Crohn disease who had previously undergone ileocolic resection were evaluated independently by two readers. Endoscopic findings, histopathologic findings, and/or the Crohn disease activity index was the reference standard. Interobserver agreement between the two readers was calculated with kappa statistics. Associations between CT enteroclysis findings and anastomotic site status were assessed at univariate analysis. The sensitivity, specificity, and accuracy of CT enteroclysis, with corresponding 95% confidence intervals (CIs), for the diagnosis of normal versus abnormal anastomosis and the diagnosis of anastomotic recurrence versus fibrostenosis were estimated. RESULTS:Interobserver agreement regarding CT enteroclysis criteria was good to perfect (kappa = 0.72-1.00). At univariate analysis, stratification and anastomotic wall thickening were the two most discriminating variables in the differentiation between normal and abnormal anastomoses (P < .001). Stratification (P < .001) and the comb sign (P = .026) were the two most discriminating variables in the differentiation between anastomotic recurrence and fibrostenosis. In the diagnosis of anastomotic recurrence, severe anastomotic stenosis was the most sensitive finding (95% [20 of 21 patients]; 95% CI: 76.18%, 99.88%), both comb sign and stratification had 95% specificity (18 of 19 patients; 95% CI: 73.97%, 99.87%), and stratification was the most accurate finding (92% [37 of 40 patients]; 95% CI: 79.61%, 98.43%). In the diagnosis of fibrostenosis, both severe anastomotic stenosis and anastomotic wall thickening were 100% sensitive (eight of eight patients; 95% CI: 63.06%, 100.00%), and using an association among five categorical variables, including severe anastomotic stenosis, anastomotic wall thickening with normal or mild mucosal enhancement, absence of comb sign, and absence of fistula, yielded 88% sensitivity (seven of eight patients; 95% CI: 47.35%, 99.68%), 97% specificity (31 of 32 patients; 95% CI: 83.78%, 99.92%), and 95% accuracy (38 of 40 patients; 95% CI: 83.08%, 99.39%). CONCLUSION:CT enteroclysis yields objective and relatively specific morphologic criteria that help differentiate between recurrent disease and fibrostenosis at the anastomotic site after ileocolic resection for Crohn disease. SUPPLEMENTAL MATERIAL:http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.09091165/-/DC1.
journal_name
Radiologyjournal_title
Radiologyauthors
Soyer P,Boudiaf M,Sirol M,Dray X,Aout M,Duchat F,Vahedi K,Fargeaudou Y,Martin-Grivaud S,Hamzi L,Vicaut E,Rymer Rdoi
10.1148/radiol.09091165subject
Has Abstractpub_date
2010-03-01 00:00:00pages
755-64issue
3eissn
0033-8419issn
1527-1315pii
254/3/755journal_volume
254pub_type
杂志文章相关文献
RADIOLOGY文献大全abstract::Twenty-four patients with hepatocellular carcinoma or cholangiocarcinoma were treated with hepatic artery infusion (HAI) of chemotherapeutic agents (14 patients) or hepatic artery embolization (HAE) (11 patients). One patient had a combination of the two treatments. Ten of the 14 (71%) patients who underwent HAI demon...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.147.1.6298860
更新日期:1983-04-01 00:00:00
abstract:PURPOSE:To investigate the feasibility of breast tissue characterization in terms of water, lipid, and protein contents with a spectral computed tomographic (CT) system based on a cadmium zinc telluride (CZT) photon-counting detector by using postmortem breasts. MATERIALS AND METHODS:Nineteen pairs of postmortem breas...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.14132732
更新日期:2014-09-01 00:00:00
abstract::We report qualitative and quantitative evaluation and verification studies of the bipolar phase gradient modulation method for true MR imaging of internal flow and motion velocities. Velocity encoding modulations provide speed-of-motion and direction-sensitive images using special phase-sensitive reconstructions. True...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.154.2.3966130
更新日期:1985-02-01 00:00:00
abstract:PURPOSE:To correlate upper gastrointestinal study findings of the position of the duodenum and duodenal-jejunal junction in children after liver transplantation with transplant type, age at transplantation, indication for transplantation, and history of surgery or malrotation. MATERIALS AND METHODS:Upper gastrointesti...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.207.1.9530320
更新日期:1998-04-01 00:00:00
abstract::Enemas of various solutions were administered to rats to determine if Gastrografin was specifically irritating to the colonic mucosa. Gastrografin was found to cause considerably more inflammation than Hypaque-25, or barium sulfate. Further studies with hypertonic sorbitol, Renografin-76, and Tween 80 suggested that (...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/118.3.545
更新日期:1976-03-01 00:00:00
abstract::The United States of America changed the composition of the penny in 1982. It is now a copper-plated, zinc-based coin. Erosions of the edge of this new coin were observed when it was impacted in the esophagus of a 13-month-old child. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.158.2.3941880
更新日期:1986-02-01 00:00:00
abstract:PURPOSE:To compare image resolution from iterative reconstruction with resolution from filtered back projection for low-contrast objects on phantom computed tomographic (CT) images across vendors and exposure levels. MATERIALS AND METHODS:Randomized repeat scans of an American College of Radiology CT accreditation pha...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2015141260
更新日期:2015-10-01 00:00:00
abstract::In situ saphenous vein grafts are being used with increasing frequency for bypass procedures involving the femoral and popliteal arteries. Complications of these procedures include anastomotic stenoses and persistent arteriovenous fistulae that may result in failure of the graft. Balloon angioplasty and embolotherapy ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.160.3.3737910
更新日期:1986-09-01 00:00:00
abstract::Twenty-eight patients with intra-abdominal mesenchymal sarcomas were examined with gray scale ultrasonography. Masses were present in the mesentery, abdominal hollow viscera, liver, and retroperitoneal areas. Four different ultrasonic patterns were observed in the extra hepatic abdominal masses: (a) hyperechoic masses...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/128.1.193
更新日期:1978-07-01 00:00:00
abstract:PURPOSE:To evaluate the cochlear modiolus with thin-section magnetic resonance (MR) imaging in healthy subjects and patients with a large endolymphatic duct and sac, and to assess whether the cochlea is normal or abnormal in patients with a large endolymphatic duct and sac. MATERIALS AND METHODS:MR images were obtaine...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.213.3.r99dc05819
更新日期:1999-12-01 00:00:00
abstract:PURPOSE:To compare magnetic resonance (MR) imaging of the oropharynx in patients with sleep apnea syndrome with fiberoptic nasopharyngoscopy, and oropharyngeal pressure and apnea index values. MATERIALS AND METHODS:After sleep induction, 24 patients with sleep apnea syndrome and nine patients with non-sleep-apnea snor...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.201.2.8888230
更新日期:1996-11-01 00:00:00
abstract:PURPOSE:To measure serum calcium concentration with three different analytic methods after administration of gadoversetamide and three other gadolinium chelates in dogs. MATERIALS AND METHODS:Six dogs were injected with 0.1-, 0.3-, 1.0-, and 3.0-mmol/kg doses of gadoversetamide; 1.0-mmol/kg doses of gadodiamide, gadop...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2331031689
更新日期:2004-10-01 00:00:00
abstract:PURPOSE:To investigate the effect of variations in anatomic features of the circle of Willis on the perfusion territory to deep structures, including the nucleus caudatus, the nucleus lentiformis, and the thalamus. MATERIALS AND METHODS:The ethics committee of the study institution approved the study protocol. A total...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.09090284
更新日期:2010-03-01 00:00:00
abstract:PURPOSE:To test whether magnetic resonance (MR) imaging enables accurate measurement of extraction fraction (EF) in swine with unilateral renal ischemia and to evaluate effects of renal arterial stenosis on EF and single-kidney glomerular filtration rate. MATERIALS AND METHODS:High-grade unilateral renal arterial sten...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2231010420
更新日期:2002-04-01 00:00:00
abstract::Percutaneous aspiration of the gallbladder was performed for nine hospitalized patients, most commonly to establish the diagnosis of acute cholecystitis and its complications in the critically ill patient or patient with sepsis. In five patients, aspiration alone was performed; in four, permanent percutaneous catheter...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.155.3.3890000
更新日期:1985-06-01 00:00:00
abstract::Primary and secondary lung malignancies are often treated with surgery. Many patients are poor surgical candidates owing to advanced age or medical comorbidities. Alternatives to surgery for localized disease include radiation therapy and the newer treatments known as image-guided thermal ablation. Image-guided therma...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.11091126
更新日期:2011-09-01 00:00:00
abstract::Gianturco expandable metallic stents were used for treating six patients with inferior vena cava (IVC) obstruction due to compression by large hepatic tumors and three patients with idiopathic obstruction of the hepatic IVC and Budd-Chiari syndrome who showed reocclusion or stenosis 3-21 months after previously perfor...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.176.3.2143840
更新日期:1990-09-01 00:00:00
abstract::Comparison radiographs may be used to confirm subtle extremity fractures or dislocations in children. Some suggest that such views be routinely obtained. As determined by questionnaire, however, a clear majority (2:1) of pediatric radiologists do not currently utilize this procedure. Factors determining this are discu...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/126.1.209
更新日期:1978-01-01 00:00:00
abstract::Periportal low attenuation, defined as a low-attenuation rim around the portal vein and its branches that is seen on contrast material-enhanced computed tomographic (CT) scans, has been described in a variety of conditions in adults. The authors reviewed the appearance of periportal low attenuation on CT scans of 30 c...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.183.3.1584920
更新日期:1992-06-01 00:00:00
abstract::The ability of magnetic resonance (MR) imaging to detect and distinguish various stages of obstruction in the canine kidney was investigated. MR images were obtained at acute, subacute, and chronic stages of experimentally produced hydronephrosis. The renal cortex was distinguished from the renal medulla in the normal...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.152.1.6729100
更新日期:1984-07-01 00:00:00
abstract:PURPOSE:To determine whether perfusion-weighted and proton spectroscopic MR imaging can be used to differentiate high-grade primary gliomas and solitary metastases on the basis of differences in vascularity and metabolite levels in the peritumoral region. MATERIALS AND METHODS:Fifty-one patients with a solitary brain ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2223010558
更新日期:2002-03-01 00:00:00
abstract::Purpose To assess the utility of established functional markers versus two additional functional markers derived from standard cardiovascular magnetic resonance (MR) images for their incremental diagnostic and prognostic information in patients with nonischemic dilated cardiomyopathy (NIDCM). Materials and Methods App...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2016161184
更新日期:2017-06-01 00:00:00
abstract:PURPOSE:To compare and evaluate the measures of costs for core-needle and surgical breast biopsies. MATERIALS AND METHODS:Three measures of costs were evaluated: (a) input resources, (b) actual payments, and (c) billed charges. A combination of methods were used for data collection from 10 sites enrolled in a large-sc...
journal_title:Radiology
pub_type: 临床试验,杂志文章,多中心研究,随机对照试验
doi:10.1148/radiology.212.1.r99jl46181
更新日期:1999-07-01 00:00:00
abstract::Purpose To study the concomitant use of structural and functional magnetic resonance (MR) imaging correlates to explain information processing speed (IPS) and executive function (EF) in multiple sclerosis (MS). Materials and Methods Local ethics committee approval was obtained at all sites for this prospective, multic...
journal_title:Radiology
pub_type: 杂志文章,多中心研究
doi:10.1148/radiol.2016151809
更新日期:2016-09-01 00:00:00
abstract:PURPOSE:To test a neural network in differentiation of benign from malignant solitary pulmonary nodules. MATERIALS AND METHODS:Neural networks were trained and tested on the characteristics of 318 nodules. Predictive accuracy of the network was judged for calibration and discrimination. Network results were compared w...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.196.3.7644650
更新日期:1995-09-01 00:00:00
abstract::Complications of indwelling ureteral stents were managed percutaneously in 13 patients. These complications consisted of three fractured, three heavily encrusted, and seven migrated stents. While most ureteral stent malfunctions are routinely managed with retrograde techniques, the percutaneous approach allows effecti...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.158.1.3510020
更新日期:1986-01-01 00:00:00
abstract:PURPOSE:To retrospectively determine whether there is a relationship between the intranodular blood supply evaluated at computed tomography (CT) during arterial portography (CTAP) and CT during hepatic arteriography (CTHA) and the magnetic resonance (MR) imaging signal intensity of nodules associated with cirrhosis. M...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2372041389
更新日期:2005-11-01 00:00:00
abstract::The diagnosis of seminal vesicle invasion by prostatic carcinoma is based on observation of foci of relatively decreased signal intensity on T2-weighted magnetic resonance (MR) images. Similar findings were observed in the absence of tumor invasion in nine patients who had recently undergone prostatic needle biopsy. N...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.185.2.1410340
更新日期:1992-11-01 00:00:00
abstract::A commercially available double-lumen central venous catheter that can be inserted over a 0.018-inch guide wire was used for ureteral perfusion studies in three infants. Complications or difficulties were not encountered in any patients. This technique allows simultaneous monitoring of perfusion and intrarenal pressur...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.181.1.1887050
更新日期:1991-10-01 00:00:00
abstract::A technique to perform a liver biopsy through the femoral vein with the Mansfield biopsy forceps is described. Nine liver biopsy procedures were performed in seven patients who were considered at high risk of bleeding, precluding a conventional transperitoneal biopsy. The technique is an easy, safe, and well-tolerated...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.169.3.3187010
更新日期:1988-12-01 00:00:00