The impact of respiratory motion on tumor quantification and delineation in static PET/CT imaging.

Abstract:

:Our aim is to investigate the impact of respiratory motion on tumor quantification and delineation in static PET/CT imaging using a population of patient respiratory traces. A total of 1295 respiratory traces acquired during whole body PET/CT imaging were classified into three types according to the qualitative shape of their signal histograms. Each trace was scaled to three diaphragm motion amplitudes (6 mm, 11 mm and 16 mm) to drive a whole body PET/CT computer simulation that was validated with a physical phantom experiment. Three lung lesions and one liver lesion were simulated with diameters of 1 cm and 2 cm. PET data were reconstructed using the OS-EM algorithm with attenuation correction using CT images at the end-expiration phase and respiratory-averaged CT. The errors of the lesion maximum standardized uptake values (SUV(max)) and lesion volumes between motion-free and motion-blurred PET/CT images were measured and analyzed. For respiration with 11 mm diaphragm motion and larger quiescent period fraction, respiratory motion can cause a mean lesion SUV(max) underestimation of 28% and a mean lesion volume overestimation of 130% in PET/CT images with 1 cm lesions. The errors of lesion SUV(max) and volume are larger for patient traces with larger motion amplitudes. Smaller lesions are more sensitive to respiratory motion than larger lesions for the same motion amplitude. Patient respiratory traces with relatively larger quiescent period fraction yield results less subject to respiratory motion than traces with long-term amplitude variability. Mismatched attenuation correction due to respiratory motion can cause SUV(max) overestimation for lesions in the lower lung region close to the liver dome. Using respiratory-averaged CT for attenuation correction yields smaller mismatch errors than those using end-expiration CT. Respiratory motion can have a significant impact on static oncological PET/CT imaging where SUV and/or volume measurements are important. The impact is highly dependent upon motion amplitude, lesion location and size, attenuation map and respiratory pattern. To overcome the motion effect, motion compensation techniques may be necessary in clinical practice to improve the tumor quantification for determining the response to therapy or for radiation treatment planning.

journal_name

Phys Med Biol

authors

Liu C,Pierce LA 2nd,Alessio AM,Kinahan PE

doi

10.1088/0031-9155/54/24/007

subject

Has Abstract

pub_date

2009-12-21 00:00:00

pages

7345-62

issue

24

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(09)20374-5

journal_volume

54

pub_type

杂志文章
  • A study of the impact of x-ray tube performance on angiography system imaging efficiency.

    abstract::This work compared the impact of x-ray tube performance and automatic dose rate control (ADRC) parameter selection on system imaging efficiency of two Siemens angiography systems: a Siemens Megalix x-ray tube installed on an Artis Zee system (denoted 'MEGALIX') and a newer generation Gigalix x-ray tube installed on an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abbb7a

    authors: Dehairs M,Bosmans H,Marshall NW

    更新日期:2020-11-24 00:00:00

  • CT reconstruction algorithm for a dental panoramic x-ray unit.

    abstract::A variable Jacobian and weighted backprojection algorithm, used for medical CT, was adapted to perform CT reconstructions on data obtained with a dental panoramic x-ray unit. A detector array, fitted to the unit for the purpose of acquiring digital panoramic radiographs, was used to collect the data. Compensations wer...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/12/001

    authors: Lee MD,Waggener RG,McDavid WD,Dove SB,Welander U,Tronje G

    更新日期:1992-12-01 00:00:00

  • The impact of tracking system properties on the most likely path estimation in proton CT.

    abstract::Proton CT nowadays aims at improving hadron therapy treatment planning by mapping the stopping power of materials. In order to optimize a spatial resolution of the reconstructed images, the most likely path (MLP) of each proton can be computed. We investigated the errors in the computation of this path due to the conf...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/23/N197

    authors: Bopp C,Rescigno R,Rousseau M,Brasse D

    更新日期:2014-12-07 00:00:00

  • Optimization of magnetic flux density measurement using multiple RF receiver coils and multi-echo in MREIT.

    abstract::Magnetic Resonance Electrical Impedance Tomography (MREIT) is an MRI method that enables mapping of internal conductivity and/or current density via measurements of magnetic flux density signals. The MREIT measures only the z-component of the induced magnetic flux density B = (Bx, By, Bz) by external current injection...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/17/4827

    authors: Jeong WC,Chauhan M,Sajib SZ,Kim HJ,Serša I,Kwon OI,Woo EJ

    更新日期:2014-09-07 00:00:00

  • Improved method of in vivo respiratory-gated micro-CT imaging.

    abstract::The presence of motion artifacts is a typical problem in thoracic imaging. However, synchronizing the respiratory cycle with computed tomography (CT) image acquisition can reduce these artifacts. We currently employ a method of in vivo respiratory-gated micro-CT imaging for small laboratory animals (mice). This proced...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/17/023

    authors: Walters EB,Panda K,Bankson JA,Brown E,Cody DD

    更新日期:2004-09-07 00:00:00

  • Specific absorbed fractions for a revised series of the UF/NCI pediatric reference phantoms: internal photon sources.

    abstract::Assessment of radiation absorbed dose to internal organs of the body from the intake of radionuclides or, in the medical setting through the injection of radiopharmaceuticals, is generally performed based upon reference biokinetic models or patient imaging data, respectively. Biokinetic models estimate the time course...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abc708

    authors: Schwarz BC,Godwin WJ,Wayson MB,Dewji SA,Jokisch DW,Lee C,Bolch WE

    更新日期:2020-11-03 00:00:00

  • Towards a gold standard for quantitative coronary arteriography.

    abstract::Densitometric quantification of coronary artery stenoses in angiographic images can be problematic for two reasons: (i) the x-rays are inadequately oriented with respect to the vessel segments of interest at image acquisition; (ii) non-linear effects due for instance to beam hardening, scattered radiation and veiling ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/12/011

    authors: Doriot PA,Dorsaz PA,Dorsaz L,Bodenmann JJ

    更新日期:1997-12-01 00:00:00

  • Modelling the electrical properties of tissue as a porous medium.

    abstract::Models of the electrical properties of biological tissue have been the subject of many studies. These models have sought to explain aspects of the dielectric dispersion of tissue. This paper develops a mathematical model of the complex permittivity of tissue as a function of frequency f, in the range 10(4) < f < 10(7)...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/23/016

    authors: Smye SW,Evans CJ,Robinson MP,Sleeman BD

    更新日期:2007-12-07 00:00:00

  • A novel technique for measuring the low-dose envelope of pencil-beam scanning spot profiles.

    abstract::To investigate the profile measurement capabilities of an IBA-Dosimetry scintillation detector and to assess its feasibility for determining the low-intensity tails of pencil-beam scanning spots, the responses of the scintillation detector and Gafchromic EBT2 film to a 115 MeV proton spot were measured in-air at the i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/12/N171

    authors: Lin L,Ainsley CG,Mertens T,De Wilde O,Talla PT,McDonough JE

    更新日期:2013-06-21 00:00:00

  • Impact of free-breathing CT on quantitative measurements of static and quiescent period-gated PET Images.

    abstract::Measurements of standardized uptake values (SUV) can vary due to many causes, including respiratory motion. Various methodologies have been introduced to correct for motion in PET, with quiescent-period-gated (QPG) PET being the most popular approach. QPG has been shown to improve PET image quantification compared to ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab1cdd

    authors: Meier JG,Einstein SA,Diab RH,Erasmus LJ,Xu G,Mawlawi OR

    更新日期:2019-05-16 00:00:00

  • Optimisation of the imaging and dosimetric characteristics of an electronic portal imaging device employing plastic scintillating fibres using Monte Carlo simulations.

    abstract::A Monte Carlo model of a novel electronic portal imaging device (EPID) has been developed using Geant4 and its performance for imaging and dosimetry applications in radiotherapy has been characterised. The EPID geometry is based on a physical prototype under ongoing investigation and comprises an array of plastic scin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/22/6827

    authors: Blake SJ,McNamara AL,Vial P,Holloway L,Kuncic Z

    更新日期:2014-11-21 00:00:00

  • An investigation and explanation of the fall-off of x-ray tube current during an exposure.

    abstract::It was observed that the radiation output of x-ray tubes falls off exponentially during an exposure with a time constant of about 120 ms. The equilibrium value is approximately 15% lower than that at the beginning of the exposure. The clinically noticeable consequences are discrepancies in x-ray generator calibration,...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/25/2/004

    authors: Brezovich IA,Barnes GT

    更新日期:1980-03-01 00:00:00

  • Inverse planning for functional image-guided intensity-modulated radiation therapy.

    abstract::Radiation therapy is an image-guided process whose success critically depends on the imaging modality used for treatment planning and the level of integration of the available imaging information. In this work, we establish a dose optimization framework for incorporating metabolic information from functional imaging m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/20/301

    authors: Xing L,Cotrutz C,Hunjan S,Boyer AL,Adalsteinsson E,Spielman D

    更新日期:2002-10-21 00:00:00

  • Numerical calculation of energy deposition by broad high-energy electron beams.

    abstract::The feasibility is demonstrated of a numerical method to calculate dose deposition by broad high-energy electron beams in homogeneous matter or in heterogeneous matter in which the heterogeneities are arranged in slabs perpendicular to the beam axis. The method is based only on the basic physical interaction processes...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/10/003

    authors: Huizenga H,Storchi PR

    更新日期:1989-10-01 00:00:00

  • Convex reformulation of biologically-based multi-criteria intensity-modulated radiation therapy optimization including fractionation effects.

    abstract::Finding fluence maps for intensity-modulated radiation therapy (IMRT) can be formulated as a multi-criteria optimization problem for which Pareto optimal treatment plans exist. To account for the dose-per-fraction effect of fractionated IMRT, it is desirable to exploit radiobiological treatment plan evaluation criteri...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/22/006

    authors: Hoffmann AL,den Hertog D,Siem AY,Kaanders JH,Huizenga H

    更新日期:2008-11-21 00:00:00

  • Influence of vascular normalization on interstitial flow and delivery of liposomes in tumors.

    abstract::Elevated interstitial fluid pressure is one of the barriers of drug delivery in solid tumors. Recent studies have shown that normalization of tumor vasculature by anti-angiogenic factors may improve the delivery of conventional cytotoxic drugs, possibly by increasing blood flow, decreasing interstitial fluid pressure,...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/4/1477

    authors: Ozturk D,Yonucu S,Yilmaz D,Unlu MB

    更新日期:2015-02-21 00:00:00

  • Development of a fast Monte Carlo dose calculation system for online adaptive radiation therapy quality assurance.

    abstract::Online adaptive radiation therapy (ART) based on real-time magnetic resonance imaging represents a paradigm-changing treatment scheme. However, conventional quality assurance (QA) methods based on phantom measurements are not feasible with the patient on the treatment couch. The purpose of this work is to develop a fa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6e38

    authors: Wang Y,Mazur TR,Park JC,Yang D,Mutic S,Li HH

    更新日期:2017-06-21 00:00:00

  • Clinically feasible reconstruction of 3D whole-body PET/CT data using blurred anatomical labels.

    abstract::We present the results of utilizing aligned anatomical information from CT images to locally adjust image smoothness during the reconstruction of three-dimensional (3D) whole-body positron emission tomography (PET) data. The ability of whole-body PET imaging to detect malignant neoplasms is becoming widely recognized....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/1/301

    authors: Comtat C,Kinahan PE,Fessler JA,Beyer T,Townsend DW,Defrise M,Michel C

    更新日期:2002-01-07 00:00:00

  • Proton beam monitor chamber calibration.

    abstract::The first goal of this paper is to clarify the reference conditions for the reference dosimetry of clinical proton beams. A clear distinction is made between proton beam delivery systems which should be calibrated with a spread-out Bragg peak field and those that should be calibrated with a (pseudo-)monoenergetic prot...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/17/4961

    authors: Gomà C,Lorentini S,Meer D,Safai S

    更新日期:2014-09-07 00:00:00

  • An adaptive technique for digital noise suppression in on-line portal imaging.

    abstract::Two complementary approaches to the noise suppression problem in on-line portal imaging have been analysed. Temporal filtering by image summation can substantially reduce the amount of noise in an image. In many cases, however, movements of the patient or the radiation source limit the time period over which the avera...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/35/3/011

    authors: Leszczynski KW,Shalev S,Cosby NS

    更新日期:1990-03-01 00:00:00

  • Including robustness in multi-criteria optimization for intensity-modulated proton therapy.

    abstract::We present a method to include robustness in a multi-criteria optimization (MCO) framework for intensity-modulated proton therapy (IMPT). The approach allows one to simultaneously explore the trade-off between different objectives as well as the trade-off between robustness and nominal plan quality. In MCO, a database...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/3/591

    authors: Chen W,Unkelbach J,Trofimov A,Madden T,Kooy H,Bortfeld T,Craft D

    更新日期:2012-02-07 00:00:00

  • Physical modelling of electroporation in close cell-to-cell proximity environments.

    abstract::Many applications of electroporation, especially those utilizing electrofusion and in-vivo electroporation, involve cell environments that include close cell-to-cell proximity and a wide range of target cell size. It is important to understand how this kind of environment may alter optimum electroporation electrical p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/12/012

    authors: Gaynor PT,Bodger PS

    更新日期:2006-06-21 00:00:00

  • High-resolution fluence verification for treatment plan specific QA in ion beam radiotherapy.

    abstract::Ion beam radiotherapy exploits the finite range of ion beams and the increased dose deposition of ions toward the end of their range in material. This results in high dose conformation to the target region, which can be further increased using scanning ion beams. The standard method for patient-plan verification in io...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/6/1725

    authors: Martišíková M,Brons S,Hesse BM,Jäkel O

    更新日期:2013-03-21 00:00:00

  • A Monte Carlo study of the variation of electron fluence in water from a 6 MV photon beam outside of the field.

    abstract::Existing studies have suggested some debate on whether the quality of radiation that delivers dose outside of the primary field of a radiotherapy photon beam can be considered the same as that inside the primary field. We used a Monte Carlo approach to simulate the electron fluence differential in energy inside a wate...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/12/015

    authors: Kirkby C,Field C,MacKenzie M,Syme A,Fallone BG

    更新日期:2007-06-21 00:00:00

  • Energy and spatial distribution of multiple order Compton scatter in SPECT: a Monte Carlo investigation.

    abstract::Energy and spatial projection distributions were simulated for gamma camera imaging of multiple order Compton scattered photons. SPECT imaging of a line source of radioactivity located in a water filled cylindrical phantom was modelled using Monte Carlo techniques. Photon trajectories were followed from emission to de...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/29/10/005

    authors: Floyd CE,Jaszczak RJ,Harris CC,Coleman RE

    更新日期:1984-10-01 00:00:00

  • Assessment of thermal effects in a model of the human head implanted with a wireless active microvalve for the treatment of glaucoma creating a filtering bleb.

    abstract::A 3D anatomical computational model is developed to assess thermal effects due to exposure to the electromagnetic field required to power a new investigational active implantable microvalve for the treatment of glaucoma. Such a device, located in the temporal superior eye quadrant, produces a filtering bleb, which is ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa5dae

    authors: Schaumburg F,Guarnieri FA

    更新日期:2017-05-07 00:00:00

  • In vivo electric conductivity of cervical cancer patients based on B₁⁺ maps at 3T MRI.

    abstract::The in vivo electric conductivity (σ) values of tissue are essential for accurate electromagnetic simulations and specific absorption rate (SAR) assessment for applications such as thermal dose computations in hyperthermia. Currently used σ-values are mostly based on ex vivo measurements. In this study the conductivit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/4/1596

    authors: Balidemaj E,de Boer P,van Lier AL,Remis RF,Stalpers LJ,Westerveld GH,Nederveen AJ,van den Berg CA,Crezee J

    更新日期:2016-02-21 00:00:00

  • Effects of injected dose, BMI and scanner type on NECR and image noise in PET imaging.

    abstract::Noise equivalent count rate (NECR) and image noise are two different but related metrics that have been used to predict and assess image quality, respectively. The aim of this study is to investigate, using patient studies, the relationships between injected dose (ID), body mass index (BMI) and scanner type on NECR an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/16/013

    authors: Chang T,Chang G,Kohlmyer S,Clark JW,Rohren E,Mawlawi OR

    更新日期:2011-08-21 00:00:00

  • Low-frequency conductivity tensor imaging with a single current injection using DT-MREIT.

    abstract::Diffusion tensor - magnetic resonance electrical impedance tomography (DT-MREIT) is an imaging modality to obtain low-frequency anisotropic conductivity distribution employing diffusion tensor imaging (DTI) and magnetic resonance electrical impedance tomography (MREIT) techniques. DT-MREIT is based on the linear relat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abddcf

    authors: Sadighi M,Sisman M,Acikgoz BC,Eroglu HH,Eyuboglu BM

    更新日期:2021-01-20 00:00:00

  • Integral equations and boundary-element solution for static potential in a general piece-wise homogeneous volume conductor.

    abstract::Boundary element methods (BEM) are used for forward computation of bioelectromagnetic fields in multi-compartment volume conductor models. Most BEM approaches assume that each compartment is in contact with at most one external compartment. In this work, I present a general surface integral equation and BEM discretiza...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/22/N606

    authors: Stenroos M

    更新日期:2016-11-21 00:00:00