Axial acoustic radiation force of progressive cylindrical diverging waves on a rigid and a soft cylinder immersed in an ideal compressible fluid.

Abstract:

BACKGROUND AND MOTIVATION:Previous works investigating the radiation force of diverging spherical progressive waves incident upon spherical particles have demonstrated the direction of reversal of the force when the particle is subjected to a curved wave-front. In this communication, the analysis is extended to the case of diverging cylindrical progressive waves incident upon a rigid or a soft cylinder in a non-viscous fluid with explicit calculations for the radiation force function (which is the radiation force per unit energy density and unit cross-sectional surface) not shown in [F.G. Mitri, Ultrasonics 50 (2010) 620-627]. METHOD:A closed-form solution presented previously in [F.G. Mitri, Ultrasonics 50 (2010) 620-627] is used to plot the radiation force function with particular emphasis on the difference from the results of incident plane progressive waves versus the size parameter ka (k is the wave number and a is the cylinder's radius) and the distance of the cylinder from the acoustic source r(0). RESULTS:Radiation force function calculations for the rigid cylinder unexpectedly reveal that under specific conditions determined by the frequency of the acoustic field, the radius of the cylinder, as well as the distance to the acoustic source, the force becomes attractive (negative force). In addition, the numerical results show that the radiation force on a rigid cylinder does not generally obey the inverse-distance law with respect to the distance from the source. CONCLUSION AND POTENTIAL APPLICATIONS:These results suggest that it may be possible, under specific conditions, to pull a cylindrical structure back toward the acoustic source using progressive cylindrical diverging waves. They may also provide a means to predict the radiation force required to manipulate non-destructively a single cylindrical structure. Potential applications include the design of a new generation of acoustic tweezers operating using a single beam of progressive waves (in contrast to the traditional version of acoustical tweezers in which an acoustic standing wave field is produced using two counter-propagating acoustic fields) for investigations in the field of flow cytometry, particle manipulation and entrapment.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Mitri FG,Fellah ZE

doi

10.1016/j.ultras.2010.12.004

subject

Has Abstract

pub_date

2011-07-01 00:00:00

pages

523-6

issue

5

eissn

0041-624X

issn

1874-9968

pii

S0041-624X(10)00190-3

journal_volume

51

pub_type

杂志文章
  • Viability of plant cell suspensions exposed to homogeneous ultrasonic fields of different energy density and wave type.

    abstract::Exposure of Petunia hybrida cell suspensions to ultrasound at a frequency of 2.43 MHz in a standing wave field at an energy density of 70 Jm-3 (pressure amplitude of 0.78 MPa) decreased their mean viability to 35% after 20 min of sonication. A comparison of propagating wave and standing wave treatments at equal freque...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00166-3

    authors: Böhm H,Anthony P,Davey MR,Briarty LG,Power JB,Lowe KC,Benes E,Gröschl M

    更新日期:2000-03-01 00:00:00

  • Interlaboratory evaluation of hydrophone sensitivity calibration from 0.1 to 2 MHz via time delay spectrometry.

    abstract::Knowing the low-frequency response of hydrophones, down to 100 kHz at least, is important for accurate biomedical ultrasound measurements. However, current international standards do not extend below 500 kHz. Furthermore, commercial hydrophone sources typically do not supply sensitivity data below 1-2 MHz. Therefore, ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2003.12.008

    authors: Harris GR,Gammell PM,Lewin PA,Radulescu EG

    更新日期:2004-04-01 00:00:00

  • Band structure calculation of SH waves in nanoscale multilayered piezoelectric phononic crystals using radial basis function method with consideration of nonlocal interface effects.

    abstract::In this paper, the radial basis function (RBF) collocation method based on the nonlocal Eringen piezoelectricity theory is developed to compute the band structures of nanoscale multilayered piezoelectric phononic crystals taking account of nonlocal interface effects. Detailed calculations are performed for anti-plane ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.09.009

    authors: Yan Z,Wei C,Zhang C

    更新日期:2017-01-01 00:00:00

  • Characteristic model of travelling wave ultrasonic motor.

    abstract::In general, the design and analysis of ultrasonic motor and motor's control strategy are based on mathematical model. The academic model is widely used in the analysis of traveling wave ultrasonic motor (TWUSM). But the dispersive characteristic of piezoelectric ceramics and other complicated process, such as the fric...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.09.012

    authors: Jingzhuo S,Dongmei Y

    更新日期:2014-02-01 00:00:00

  • EMAT phased array: A feasibility study of surface crack detection.

    abstract::Electromagnetic-acoustic transducers (EMATs) consist of a magnet and a coil. They are advantageous in some non-destructive evaluation (NDE) applications because no direct contact with the specimen is needed to send and receive ultrasonic waves. However, EMATs commonly require excitation peak powers greater than 1kW an...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.02.009

    authors: Isla J,Cegla F

    更新日期:2017-07-01 00:00:00

  • Long-path measurements of ultrasonic attenuation and velocity for very dilute slurries and liquids and detection of contaminates.

    abstract::The objective was to use multiple paths through the slurry to determine the lowest concentration that provided accurate attenuation measurements and to measure the velocity of sound through an effective long path. Ultrasonic attenuation measurements were obtained for slurries of silica (10 microm diameter) in water fo...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.024

    authors: Greenwood MS,Adamson JD,Bamberger JA

    更新日期:2006-12-22 00:00:00

  • Numerical and experimental analysis of strongly nonlinear standing acoustic waves in axisymmetric cavities.

    abstract::In this paper the behaviour of strongly nonlinear waves in axisymmetric resonators is experimentally and numerically studied. Experiments are carried out in a cylindrical cavity, which transversal dimension is bigger than the longitudinal one, excited by a narrow band transducer. The quality factor and displacement am...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2005.02.001

    authors: Vanhille C,Campos-Pozuelo C

    更新日期:2005-08-01 00:00:00

  • New contributions to granite characterization by ultrasonic testing.

    abstract::Ultrasound evaluation permits the state of rocks to be determined quickly and cheaply, satisfying the demands faced by today's producers of ornamental stone, such as environmental sustainability, durability and safety of use. The basic objective of the present work is to analyse and develop the usefulness of ultrasoun...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2013.06.006

    authors: Cerrillo C,Jiménez A,Rufo M,Paniagua J,Pachón FT

    更新日期:2014-01-01 00:00:00

  • Phonophoresis: an in vivo evaluation using three topical anaesthetic preparations.

    abstract::An electrical sensory perception threshold technique has been developed for use with human volunteers. This technique has been used to reproducibly quantify the effects of three different commercially available topical anaesthetic preparations on superficial sensory cells (nociceptors) in the skin. Low intensities (0....

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(90)90075-y

    authors: Williams AR

    更新日期:1990-05-01 00:00:00

  • Non-contact measurement of the thickness of a surface film using a superimposed ultrasonic standing wave.

    abstract::Most methods used to measure the thickness of thin liquid or solid surface films and coatings need access to the coated surface. In this work reflected ultrasonic pulses were used to measure a coating thickness from a solid back face. Piezoelectric transducers on the solid back face emitted ultrasound waves and receiv...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106291

    authors: Kanja J,Mills R,Li X,Brunskill H,Hunter AK,Dwyer-Joyce RS

    更新日期:2021-02-01 00:00:00

  • A prosthetic aid for a developing blind child.

    abstract::An experimental ultrasonic sonar for use as a sensory aid with blind children is described. Novel signal processing techniques make the aid relatively simple to construct, yet allow many of its parameters to be changed in the field. In particular, the aid has two features, a variable range code and an automatic level...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(79)90010-6

    authors: Boys JT,Strelow ER,Clark GR

    更新日期:1979-01-01 00:00:00

  • Two dimensional modeling of elastic wave propagation in solids containing cracks with rough surfaces and friction - Part II: Numerical implementation.

    abstract::Our study aims at the creation of a numerical toolbox that describes wave propagation in samples containing internal contacts (e.g. cracks, delaminations, debondings, imperfect intergranular joints) of known geometry with postulated contact interaction laws including friction. The code consists of two entities: the co...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.07.003

    authors: Delrue S,Aleshin V,Truyaert K,Bou Matar O,Van Den Abeele K

    更新日期:2018-01-01 00:00:00

  • Subarray coherence based postfilter for eigenspace based minimum variance beamformer in ultrasound plane-wave imaging.

    abstract::This paper introduces a new beamformer, which combines the eigenspace based minimum variance (ESBMV) beamformer with a subarray coherence based postfilter (SCBP), for improving the quality of ultrasound plane-wave imaging. The ESBMV beamformer has been validated in improving the imaging contrast, but the difficulty in...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.10.026

    authors: Zhao J,Wang Y,Yu J,Guo W,Li T,Zheng YP

    更新日期:2016-02-01 00:00:00

  • Modal analysis and moving performance of a single-mode linear ultrasonic motor.

    abstract::A single-mode linear ultrasonic motor was developed in this study. On the stator, a group of four pieces of piezoelectric ceramics PZT8 were utilized to generate the ultrasonic vibration. A specially designed modal conversion horn with an oblique beam was applied to transfer the longitudinal vibration to an additional...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2020.106216

    authors: Yin Z,Dai C,Cao Z,Li W,Chen Z,Li C

    更新日期:2020-12-01 00:00:00

  • Arbitrary scattering of an acoustical high-order Bessel trigonometric (non-vortex) beam by a compressible soft fluid sphere.

    abstract::The present analysis extends the previous work on the axial acoustic scattering of a high-order Bessel trigonometric beam (HOBTB) from a fluid sphere [F.G. Mitri, J. Appl. Phys. 109 (2011) 014916] to the generalized case of arbitrary scattering from a fluid sphere placed off-axially. The scattered pressure is expresse...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.12.008

    authors: Mitri FG

    更新日期:2013-07-01 00:00:00

  • Ultrasonic excitation affects friction interactions between food materials and cutting tools.

    abstract::In the food industry, ultrasonic cutting is used to improve separation by a reduction of the cutting force. This reduction can be attributed to the modification of tool-workpiece interactions at the cutting edge and along the tool flanks because of the superposition of the cutting movement with ultrasonic vibration of...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2009.03.001

    authors: Schneider Y,Zahn S,Schindler C,Rohm H

    更新日期:2009-06-01 00:00:00

  • Development of an optical fiber hydrophone with fiber Bragg grating

    abstract::A new type of optical fiber hydrophone is constructed with a fiber Bragg grating (FBG) based on the intensity modulation of laser light in an FBG under the influence of sound pressure. The FBG hydrophone shows linearity, with dynamic range about 70 dB. It can measure amplitude and phase of an acoustic field in real ti...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00105-5

    authors: Takahashi N,Yoshimura K,Takahashi S,Imamura K

    更新日期:2000-03-01 00:00:00

  • Calculations of acoustic scattering from ellipsoidal voids: bends, krill and fish.

    abstract::The T-matrix approach is used to calculate the scattering of sound waves by an ellipsoidal void in a fluid. Results are presented for the total cross-section of a sphere as a function of frequency; this is related to the detection of the onset of bends in divers. Results are also presented for the angular variation in...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/0041-624x(83)90073-2

    authors: Cooper G,Temple JA

    更新日期:1983-07-01 00:00:00

  • An improved approximation for the Rayleigh wave equation.

    abstract::We derive a simple expression, which gives an approximate value of the Rayleigh wave velocity in an isotropic solid. This approximation is five times better than that given by Viktorov. The velocity equation can be easily inverted in order to obtain an accurate determination of the elastic constants. This procedure ca...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.09.006

    authors: Royer D,Clorennec D

    更新日期:2007-03-01 00:00:00

  • Sparse signal representation and its applications in ultrasonic NDE.

    abstract::Many sparse signal representation (SSR) algorithms have been developed in the past decade. The advantages of SSR such as compact representations and super resolution lead to the state of the art performance of SSR for processing ultrasonic non-destructive evaluation (NDE) signals. Choosing a suitable SSR algorithm and...

    journal_title:Ultrasonics

    pub_type: 杂志文章,评审

    doi:10.1016/j.ultras.2011.10.001

    authors: Zhang GM,Zhang CZ,Harvey DM

    更新日期:2012-03-01 00:00:00

  • Inversion algorithm for Lamb-wave-based depth characterization of acoustic emission sources in plate-like structures.

    abstract::An inversion algorithm (termed AEDep) is proposed for estimating the depth of acoustic emission (AE) sources in plate-like structural components. The work is motivated by the need for characterizing early-stage fatigue crack growth in such components. The algorithm achieves depth estimation by automatically extracting...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.105975

    authors: Dubuc B,Ebrahimkhanlou A,Livadiotis S,Salamone S

    更新日期:2019-11-01 00:00:00

  • Surface acoustic waves at the vacuum-thermoviscoelastic solid interface.

    abstract::The present investigation concerns the propagation of surface waves at the vacuum-solid interface of a solid which is isotropic and thermoviscoelastic, i.e., for which the effects of heat conductivity need to be taken into account. Calculations show that, in addition to the Rayleigh wave, a thermal surface wave propag...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(00)00017-2

    authors: Deschamps M,Poncelet O,Dilhaire S,Claeys W

    更新日期:2000-07-01 00:00:00

  • Design and dynamic evaluation for a linear ultrasonic stage using the thin-disc structure actuator.

    abstract::The design of a novel, single-axis ultrasonic actuating stage has been proposed. It consists of a movable plate, an edge-driving ultrasonic actuator as an actuating device, and a magnetic Magi encoder as a position sensor. The stage is impelled using a friction-contact mechanism by the ultrasonic actuator with long di...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2007.06.005

    authors: Wen F,Yen CY

    更新日期:2007-12-01 00:00:00

  • A novel approach to quantitative ultrasonic naked gene delivery and its non-invasive assessment.

    abstract::The purpose of this study was to investigate practical, safe, easy-to-use, non-cytotoxic, and reliable parameters to apply to an ultrasound (US) naked gene therapy system. The ultrasound pressure at the point of cell exposure was measured using a calibrated hydrophone and the intensity calculated. An acoustic power me...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.06.007

    authors: Wei W,Zhengzhong B,Yongjie W,Lafeng Y,Yalin M

    更新日期:2004-12-01 00:00:00

  • The wavelet response as a multiscale characterization of scattering processes at granular interfaces.

    abstract::We perform a multiscale analysis of the backscattering properties of a complex interface between water and a layer of randomly arranged glass beads with diameter D=1 mm. An acoustical experiment is done to record the wavelet response of the interface in a large frequency range from lambda/D=0.3 to lambda/D=15. The wav...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.212

    authors: Le Gonidec Y,Gibert D

    更新日期:2006-11-01 00:00:00

  • Inline ultrasonic rheometry by pulsed Doppler.

    abstract::This will be a discussion of the non-invasive determination of the viscosity of a non-Newtonian fluid in laminar pipe flow over the range of shear rates present in the pipe. The procedure used requires knowledge of the flow profile in and the pressure drop along a long straight run of pipe. The profile is determined b...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.027

    authors: Pfund DM,Greenwood MS,Bamberger JA,Pappas RA

    更新日期:2006-12-22 00:00:00

  • Thin-disk piezoceramic ultrasonic motor. Part I: design and performance evaluation.

    abstract::The purpose of this study is to gain the knowledge and experience in the design of thin-disk piezoceramic-driving ultrasonic actuator dedicated. In this paper, the design and construction of an innovative ultrasonic actuator is developed as a stator, which is a composite structure consisting of piezoceramic (PZT) memb...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(03)00128-8

    authors: Wen FL,Yen CY,Ouyang M

    更新日期:2003-08-01 00:00:00

  • Eight-channel ultrasonic device for non-invasive quality evaluation in packed milk.

    abstract::An eight-channel ultrasonic detecting device for microbiological quality evaluation of packed liquid foods is presented in this paper. This device makes possible a non-invasive detection of the microbial growth in liquid foods with no need to open the carton-based packages where they are contained. Thermal and humidit...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.07.011

    authors: Elvira L,Sampedro L,Montero de Espinosa F,Matesanz J,Gómez-Ullate Y,Resa P,Echevarría FJ,Iglesias JR

    更新日期:2006-12-01 00:00:00

  • Effects of maximum aggregate size on UPV of brick aggregate concrete.

    abstract::Investigation was carried out to study the effects of maximum aggregate size (MAS) (12.5mm, 19.0mm, 25.0mm, 37.5mm, and 50.0mm) on ultrasonic pulse velocity (UPV) of concrete. For investigation, first class bricks were collected and broken to make coarse aggregate. The aggregates were tested for specific gravity, abso...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.04.006

    authors: Mohammed TU,Mahmood AH

    更新日期:2016-07-01 00:00:00

  • Biomechanical characterization of ex vivo human brain using ultrasound shear wave spectroscopy.

    abstract::The characterization of brain tissue is crucial to better understand neurological disorders. Mechanical characterization is an emerging tool in that field. The purpose of this work was to validate a transient ultrasound technique aimed at measuring dispersion of mechanical parameters of the brain tissue. The first par...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.10.009

    authors: Nicolas E,Callé S,Nicolle S,Mitton D,Remenieras JP

    更新日期:2018-03-01 00:00:00