Development of an optical fiber hydrophone with fiber Bragg grating

Abstract:

:A new type of optical fiber hydrophone is constructed with a fiber Bragg grating (FBG) based on the intensity modulation of laser light in an FBG under the influence of sound pressure. The FBG hydrophone shows linearity, with dynamic range about 70 dB. It can measure amplitude and phase of an acoustic field in real time, and operates in a wide range of acoustic frequency, at least from 1 kHz to 3 MHz. No signal distortion is observed in the detected signal. Because of the simplicity in its operating principle and geometry, an FBG hydrophone is expected to be an acoustic sensor of high practicality compared to a conventional optical fiber hydrophone.

journal_name

Ultrasonics

journal_title

Ultrasonics

authors

Takahashi N,Yoshimura K,Takahashi S,Imamura K

doi

10.1016/s0041-624x(99)00105-5

subject

Has Abstract

pub_date

2000-03-01 00:00:00

pages

581-5

issue

1-8

eissn

0041-624X

issn

1874-9968

pii

S0041-624X(99)00105-5

journal_volume

38

pub_type

杂志文章
  • Potential of ultrasonic pulse velocity for evaluating the dimensional stability of oak and chestnut wood.

    abstract::The objective of this study was to examine the potential of ultrasonic velocity as a rapid and nondestructive method to predict the dimensional stability of oak (Quercus petraea (Mattuschka) Lieblein) and chestnut (Castanea sativa Mill.) that are commonly used in flooring industry. Ultrasonic velocity, specific gravit...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.11.007

    authors: Dündar T,Wang X,As N,Avcı E

    更新日期:2016-03-01 00:00:00

  • The influence of the thickness of non-piezoelectric pieces on pre-stressed piezotransducers.

    abstract::The mechanical pre-stress applied in piezotransducers used to generate high power ultrasound is needed to avoid ceramics fracture on traction cycle. Pre-stress levels inferior to 50 MPa can yield resonance shifting due to effectiveness of acoustic coupling between transducer pieces. Symmetrical transducers with differ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(03)00096-9

    authors: Arnold FJ,Mühlen SS

    更新日期:2003-05-01 00:00:00

  • Suppression of human 8-oxoguanine DNA glycosylase (OGG1) augments ultrasound-induced apoptosis in cervical cancer cells.

    abstract:PURPOSE:Human 8-oxoguanine DNA glycosylase (OGG1) is a major base excision repair enzyme, and it was reported to suppress the activation of intrinsic apoptotic signaling pathway in response to oxidative stress. In this study, our aim was to investigate the effects of OGG1 downregulation on ultrasound-induced apoptosis ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.07.005

    authors: Xu T,Nie Y,Bai J,Li L,Yang B,Zheng G,Zhang J,Yu J,Cheng X,Jiao J,Jing H

    更新日期:2016-12-01 00:00:00

  • Nonlinear standing waves in 2-D acoustic resonators.

    abstract::This paper deals with 2-D simulation of finite-amplitude standing waves behavior in rectangular acoustic resonators. Set of three partial differential equations in third approximation formulated in conservative form is derived from fundamental equations of gas dynamics. These equations form a closed set for two compon...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.008

    authors: Cervenka M,Bednarik M

    更新日期:2006-12-22 00:00:00

  • Thin-disk piezoceramic ultrasonic motor. Part I: design and performance evaluation.

    abstract::The purpose of this study is to gain the knowledge and experience in the design of thin-disk piezoceramic-driving ultrasonic actuator dedicated. In this paper, the design and construction of an innovative ultrasonic actuator is developed as a stator, which is a composite structure consisting of piezoceramic (PZT) memb...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(03)00128-8

    authors: Wen FL,Yen CY,Ouyang M

    更新日期:2003-08-01 00:00:00

  • Effects of ultrasonic vibrations in micro-groove turning.

    abstract::Ultrasonic vibration cutting is an efficient cutting process for mechanical micro-machining. This process can generate intricate surface textures with different geometric characteristics. Micro-grooves/micro-channels are among the most frequently encountered micro-structures and, as such, are the focus of this paper. ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.12.016

    authors: Zhang C,Guo P,Ehmann KF,Li Y

    更新日期:2016-04-01 00:00:00

  • EMAT phased array: A feasibility study of surface crack detection.

    abstract::Electromagnetic-acoustic transducers (EMATs) consist of a magnet and a coil. They are advantageous in some non-destructive evaluation (NDE) applications because no direct contact with the specimen is needed to send and receive ultrasonic waves. However, EMATs commonly require excitation peak powers greater than 1kW an...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.02.009

    authors: Isla J,Cegla F

    更新日期:2017-07-01 00:00:00

  • Phase-space topography characterization of nonlinear ultrasound waveforms.

    abstract::Fundamental understanding of ultrasound interaction with material discontinuities having closed interfaces has many engineering applications such as nondestructive evaluation of defects like kissing bonds and cracks in critical structural and mechanical components. In this paper, to analyze the acoustic field nonlinea...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.12.007

    authors: Dehghan-Niri E,Al-Beer H

    更新日期:2018-03-01 00:00:00

  • The applicability of a material-treatment laser pulse in non-destructive evaluations.

    abstract::A practical optodynamic study was performed to determine the usability of different lengths of laser pulses for the generation of ultrasonic transients in a solid material. The aim of the study was to evaluate the possibility of a dual use for a laser pulse-for laser material processing, on the one hand, and for the u...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.071

    authors: Hrovatin R,Petkovsek R,Diaci J,Mozina J

    更新日期:2006-12-22 00:00:00

  • Visualization of the interaction of guided acoustic waves with water by light refractive vibrometry.

    abstract::Guided acoustic waves, such as Lamb waves, are widely applied for material characterization, sensing of liquids and the generation of streaming in liquids. There are numerical simulation tools for the prediction of their propagation near a solid-liquid boundary but a demand for complementary measurement techniques for...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.105955

    authors: Tietze S,Lindner G

    更新日期:2019-11-01 00:00:00

  • The computations of reflection coefficients of multilayer structure based on the reformulation of Thomson-Haskell method.

    abstract::A reformulation of the Thomson-Haskell method is presented for calculating the reflection coefficients of multilayer structure immersing in the coupling fluid. Instead of directly multiplying the layer propagator matrix, the new method splits the layer propagator matrix and excursively determines the interface stiffne...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.08.004

    authors: Chen J,Bai X,Yang K,Ju BF

    更新日期:2012-12-01 00:00:00

  • Numerical and experimental study on the wave attenuation in bone--FDTD simulation of ultrasound propagation in cancellous bone.

    abstract::In cancellous bone, longitudinal waves often separate into fast and slow waves depending on the alignment of bone trabeculae in the propagation path. This interesting phenomenon becomes an effective tool for the diagnosis of osteoporosis because wave propagation behavior depends on the bone structure. Since the fast w...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2008.04.011

    authors: Nagatani Y,Mizuno K,Saeki T,Matsukawa M,Sakaguchi T,Hosoi H

    更新日期:2008-11-01 00:00:00

  • Elastic constant determination of hardwoods using ultrasonic insertion technique.

    abstract::Ultrasonic insertion technique (IT) is an ultrasonic technique which involves sample immersion in a solution to determine its acoustic properties. IT is normally used to determine the acoustic properties of a medical phantom. We proposed the use of IT as an alternative technique to the common contact ultrasonic techni...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.11.025

    authors: Mat Daud AN,Jaafar R,Ayop SK,Yaacob MIH,Rohani MS

    更新日期:2017-03-01 00:00:00

  • Needle and seed segmentation in intra-operative 3D ultrasound-guided prostate brachytherapy.

    abstract::In order to guide the needle to the correct location in 3D US-guided brachytherapy, the needle is continuously tracked as it is being inserted. A pre-scan before the needle insertion and a post-scan after the needle insertion are subtracted to obtain a difference image containing the needle. The image is projected alo...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.07.003

    authors: Ding M,Wei Z,Gardi L,Downey DB,Fenster A

    更新日期:2006-12-22 00:00:00

  • Simulation study of a chaotic cavity transducer based virtual phased array used for focusing in the bulk of a solid material.

    abstract::In acoustic and ultrasonic non-destructive testing techniques, it is sometimes beneficial to concentrate sound energy at a chosen location in space and at a specific instance in time, for example to improve the signal-to-noise ratio or activate the nonlinearity of damage features. Time Reversal (TR) techniques, taking...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2016.01.010

    authors: Delrue S,Van Den Abeele K,Bou Matar O

    更新日期:2016-04-01 00:00:00

  • Influence of acousto-optic interactions on the determination of the diffracted field by an array obtained from displacement measurements.

    abstract::This paper deals with the influence of acousto-optic interactions on the displacement measurements performed over transducer array and their effects on the predicted diffraction field. Changes on the temporal/spatial responses and the plane wave decomposition of the displacement are discussed. Modifications made on th...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2003.12.035

    authors: Certon D,Ferin G,Bou Matar O,Guyonvarch J,Remenieras JP,Patat F

    更新日期:2004-04-01 00:00:00

  • 2D array design based on Fermat spiral for ultrasound imaging.

    abstract::The main challenge faced by 3D ultrasonic imaging with 2D array transducers is the large number of elements required to achieve an acceptable level of quality in the images. Therefore, the optimisation of the array layout, in order to reduce the number of active elements in the aperture, has been a research topic in t...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2009.09.010

    authors: Martínez-Graullera O,Martín CJ,Godoy G,Ullate LG

    更新日期:2010-02-01 00:00:00

  • Location of multiple proximate flaws using perpendicular NDT ultrasonic arrays.

    abstract::An improved method for ultrasonic location of multiple flaws using perpendicular ultrasonic arrays, working in near-field conditions, is presented. The method uses the pulse-echo technique and is based on the processing of the information acquired by both the elemental emitting transducers and their adjacent ones. Thi...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2006.05.107

    authors: Rodríguez MA,Ramos A,San Emeterio JL

    更新日期:2006-12-22 00:00:00

  • Nonlinear Coda Wave Interferometry: Sensitivity to wave-induced material property changes analyzed via numerical simulations in 2D.

    abstract::The numerical studies conducted in this paper are based on our previous research (Chen et al., 2017); through use of the spectral element method, parametric sensitivity studies of Nonlinear Coda Wave Interferometry (NCWI) are established here and divided into two parts. In the first part, CWI observables are found to ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.105968

    authors: Chen G,Pageot D,Abraham O,Zhang Y,Chekroun M,Tournat V

    更新日期:2019-11-01 00:00:00

  • Sensitivity of a miniaturized touch probe sensor using PZT thin film vibrator.

    abstract::In this paper, an improved touch probe sensor device for higher sensitivity and low contact force is reported. In order to improve the resolution, we have evaluated the sensitivity and fabricated a miniaturized sensor. The sensor transducer was 3 mm long and had higher resonance frequency. The resonance frequency of t...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(02)00091-4

    authors: Kanda T,Kurosawa MK,Higuchi T

    更新日期:2002-05-01 00:00:00

  • Evidence of a broadband gap in a phononic crystal strip.

    abstract::We experimentally demonstrate a very large ultrasonic band gap in a one-dimensional phononic crystal. The structure consists of periodic tungsten pillars fixed to a tailored silicon strip with a layer of epoxy. Combining local resonances and Bragg scattering, the gap ranges from 450kHz to 1250kHz, which corresponds to...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.03.003

    authors: Coffy E,Euphrasie S,Addouche M,Vairac P,Khelif A

    更新日期:2017-07-01 00:00:00

  • Development of disposable membrane hydrophones for a frequency range from 1MHz to 10MHz.

    abstract::A method for fabricating disposable membrane hydrophones is presented. The disposable hydrophones are intended for onetime use in such damaging environments as chemically contaminating fluids and high-amplitude (peak amplitude ∼100MPa) shock wave fields, where the use of commercial membrane hydrophones is not recommen...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2017.05.016

    authors: Lee JW,Ohm WS,Kim YT

    更新日期:2017-11-01 00:00:00

  • Interlaboratory evaluation of hydrophone sensitivity calibration from 0.1 to 2 MHz via time delay spectrometry.

    abstract::Knowing the low-frequency response of hydrophones, down to 100 kHz at least, is important for accurate biomedical ultrasound measurements. However, current international standards do not extend below 500 kHz. Furthermore, commercial hydrophone sources typically do not supply sensitivity data below 1-2 MHz. Therefore, ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2003.12.008

    authors: Harris GR,Gammell PM,Lewin PA,Radulescu EG

    更新日期:2004-04-01 00:00:00

  • Investigating ultrasound-induced acoustic softening in aluminum and its alloys.

    abstract::Ultrasonic vibration has been observed to lower the flow stress necessary to initiate plastic deformation, a phenomenon known as "acoustic softening". This unique effect of ultrasound has been extensively applied in welding, machining, forming of metals, and ultrasonic additive manufacturing to lower the yield stress ...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2019.106005

    authors: Mao Q,Coutris N,Rack H,Fadel G,Gibert J

    更新日期:2020-03-01 00:00:00

  • The propagation of ultrasound in an austenitic weld

    abstract::The propagation of ultrasound through an austenitic weld is investigated experimentally as well as in a numerical simulation. The weld is insonified at normal incidence to the fusion line with a longitudinal contact transducer. In order to experimentally trace the ultrasound through the weld, slices of different thick...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(99)00103-1

    authors: Halkjaer S,Sorensen MP,Kristensen WD

    更新日期:2000-03-01 00:00:00

  • Amplitude degradation of time-reversed pulses in nonlinear absorbing thermoviscous fluids.

    abstract::The linear wave equation in a lossless medium is time reversible, i.e., every solution p(x, t) has a temporal mirror solution p(x, -t). Analysis shows that time reversal also holds for the lossless nonlinear wave equation. In both cases, time-reversal invariance is violated when losses are present. For nonlinear propa...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/s0041-624x(00)00020-2

    authors: Hallaj IM,Cleveland R0,Barbone PE,Kargl SG,Roy RA

    更新日期:2000-09-01 00:00:00

  • Thickness-shear and thickness-twist modes in an AT-cut quartz acoustic wave filter.

    abstract::We studied thickness-shear and thickness-twist vibrations of a monolithic, two-pole crystal filter made from a plate of AT-cut quartz. The scalar differential equations derived by Tiersten and Smythe for electroded and unelectroded quartz plates were employed which are valid for both the fundamental and the overtone m...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2015.01.003

    authors: Zhao Z,Qian Z,Wang B,Yang J

    更新日期:2015-04-01 00:00:00

  • Ultrasonic excitation affects friction interactions between food materials and cutting tools.

    abstract::In the food industry, ultrasonic cutting is used to improve separation by a reduction of the cutting force. This reduction can be attributed to the modification of tool-workpiece interactions at the cutting edge and along the tool flanks because of the superposition of the cutting movement with ultrasonic vibration of...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2009.03.001

    authors: Schneider Y,Zahn S,Schindler C,Rohm H

    更新日期:2009-06-01 00:00:00

  • Detecting broken-wire flaws at multiple locations in the same wire of prestressing strands using guided waves.

    abstract::Broken wires often occur at multiple locations in the same wire of a strand due to the recovery length, which is defined as the length of the wire taking up its full share of the axial load from the break point. The detection of broken-wire flaws at multiple locations along the same wire is investigated using guided w...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2012.05.003

    authors: Xu J,Wu X,Sun P

    更新日期:2013-01-01 00:00:00

  • Design of ultrasonic wedge transducer.

    abstract::Cones and wedges inserted between an ultrasonic transducer and the specimen provide the transducer (circular or rectangular shape) with enhanced capability for point or line contact with the specimen. Such an arrangement is useful in that the transducer can be used for transmitting to and receiving from a point (or li...

    journal_title:Ultrasonics

    pub_type: 杂志文章

    doi:10.1016/j.ultras.2004.10.002

    authors: Rus G,Wooh SC,Gallego R

    更新日期:2005-03-01 00:00:00