Abstract:
PURPOSE:To examine the feasibility and safety of magnetic resonance (MR)-guided biopsy by using a transgluteal approach in patients with suspicious prostate lesions by using an MR-compatible robotic system and a 1.5-T MR system. MATERIALS AND METHODS:The study was approved by the institutional review board of University Frankfurt, and informed consent was obtained from each patient. A total of 20 patients (age range, 57.8-71.9 years; mean age, 65.1 years) underwent biopsy in a closed-bore high-field-strength MR system. Biopsy was performed with an MR-compatible pneumatically driven robotic system. T1-weighted gradient-echo fast low-angle shot and T2-weighted true fast imaging with steady-state precession sequences were used to plan and guide the intervention with a transgluteal access on the external planning computer of the assistance system. The system calculated the trajectory and then moved the guiding arm to the insertion point. The cannula was advanced manually, and biopsies were performed with the coaxial technique by using a 15-gauge pencil tip needle. Intervention time, complications, and biopsy findings were documented. RESULTS:The MR-compatible robotic system did not interfere with image quality, nor did MR imaging cause dysfunction of the robot. In one patient, the interventionist caused a fail-safe system shutdown. This was due to inadvertent displacement of the guiding arm during cannula insertion. This problem was solved by increasing the displacement threshold. Accurate coaxial cannula biopsy could be performed in all subsequent patients. Sufficient histopathologic assessment was performed in 19 patients. Insufficient material was retrieved in the patient who experienced fail-safe system shutdown. The median intervention time was 39 minutes (23-65 minutes). No procedure-related complications were observed. CONCLUSION:Preliminary results indicate that MR-guided robot-assisted biopsy is feasible and can be performed safely with highly accurate cannula placement.
journal_name
Radiologyjournal_title
Radiologyauthors
Zangos S,Melzer A,Eichler K,Sadighi C,Thalhammer A,Bodelle B,Wolf R,Gruber-Rouh T,Proschek D,Hammerstingl R,Müller C,Mack MG,Vogl TJdoi
10.1148/radiol.11101559subject
Has Abstractpub_date
2011-06-01 00:00:00pages
903-10issue
3eissn
0033-8419issn
1527-1315pii
radiol.11101559journal_volume
259pub_type
杂志文章相关文献
RADIOLOGY文献大全abstract::HistoryAn 18-year-old man was diagnosed with precursor B-cell lymphoblastic leukemia and underwent transplantation of hematopoietic stem cells from his human leukocyte antigen-matched sister 1 year prior to admission. He was admitted to evaluate progressive shortness of breath and dry cough of 1-month duration. He did...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2020182477
更新日期:2020-09-01 00:00:00
abstract::The effect of nuclear magnetic resonance (NMR) imaging on six representative cardiac pacemakers was studied. The results indicate that the threshold for initiating the asynchronous mode of a pacemaker is 17 gauss. Radiofrequency levels are present in an NMR unit and may confuse or possibly inhibit demand pacemakers, a...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.147.1.6828720
更新日期:1983-04-01 00:00:00
abstract:PURPOSE:To measure mean cerebral blood flow (CBF) in ischemic and nonischemic territories and in low-attenuation regions in patients with acute stroke by using deconvolution-derived hemodynamic imaging. MATERIALS AND METHODS:Twelve patients with acute middle cerebral artery stroke and 12 control patients were examined...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2221010471
更新日期:2002-01-01 00:00:00
abstract:PURPOSE:To prospectively investigate the ability of a single generator to power multiple small-diameter antennas and create large zones of ablation in an in vivo swine liver model. MATERIALS AND METHODS:Thirteen female domestic swine (mean weight, 70 kg) were used for the study as approved by the animal care and use c...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2441052054
更新日期:2007-07-01 00:00:00
abstract::A prospective, comparative study was made of the efficacy of technetium-99m pyrophosphate (Tc PYP) and technetium-99m methylene diphosphonate (Tc MDP) in detecting soft-tissue amyloidosis. Tc PYP and Tc MDP scans were obtained within ten-day intervals in seven patients with histologically proven amyloidosis. Tc PYP wa...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.148.1.6304810
更新日期:1983-07-01 00:00:00
abstract::The purpose of this study, which was approved by the institutional review board, was to assess the differentiation of individuals with from those without mesenteric ischemia. All subjects provided written informed consent. Six healthy volunteers and six patients with documented chronic mesenteric ischemia underwent ma...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2342031002
更新日期:2005-02-01 00:00:00
abstract:PURPOSE:To assess the existence of a mismatch between lesions on diffusion-weighted (DW) and perfusion-weighted (PW) magnetic resonance (MR) images obtained within 24 hours after onset of acute stroke and to use mismatch data and angiographic evidence of proximal arterial occlusion (PAO) to investigate whether the exis...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2503080811
更新日期:2009-03-01 00:00:00
abstract::Medical physics has changed dramatically since 1895. There was a period of slow evolutionary change during the first 70 years after Roentgen's discovery of x rays. With the advent of the computer, however, both diagnostic and therapeutic radiology have undergone rapid growth and changes. Technologic advances such as c...
journal_title:Radiology
pub_type: 历史文章,杂志文章
doi:10.1148/radiology.217.3.r00dc36619
更新日期:2000-12-01 00:00:00
abstract::The goals of reconstructive surgery for scaphoid fracture nonunions include restoration of normal scaphoid length and shape by use of the contralateral scaphoid bone as a geometric model. A literature search revealed limited documentation of normal biometric measurements and no validation of scaphoid anatomic symmetry...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.187.1.8451410
更新日期:1993-04-01 00:00:00
abstract:PURPOSE:To compare lung densitometric measurements that use a three-dimensional (3D) reconstruction of the lungs with those obtained from analysis of two-dimensional (2D) computed tomographic (CT) images, visual emphysema scores, and data from pulmonary function tests. MATERIALS AND METHODS:Thoracic helical CT scans w...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.211.2.r99ma52541
更新日期:1999-05-01 00:00:00
abstract::One hundred thirty-three cervical spine radiographs of 50 patients with rheumatoid arthritis were examined. The patients were a representative random sample chosen from among 675 patients followed up for more than 10 years. The frequency of occurrence for each radiographic finding was correlated with the duration of r...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.165.1.3628760
更新日期:1987-10-01 00:00:00
abstract::Skull scintigraphy was performed in 68 children with suspected craniosynostosis after injection of technetium-99m methylene diphosphonate. The scans demonstrated four patterns of sutural activity: normal, absent, increased, and wide. When correlated with surgical findings, "absent" indicated fused sutures, "increased"...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/133.3.615
更新日期:1979-12-01 00:00:00
abstract::It is usually easy to distinguish the round nipple shadow from a lesion, especially by means of repeat radiographs with nipple markers. However, the radiologist must occasionally interpret a round density in the lower chest on the basis of a single radiograph or series of radiographs. Fortunately, a nipple shadow usua...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/121.2.293
更新日期:1976-11-01 00:00:00
abstract::Perfusion computed tomography (CT) is a relatively new technique that allows rapid qualitative and quantitative evaluation of cerebral perfusion by generating maps of cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT). The technique is based on the central volume principle (CBF = CBV/M...
journal_title:Radiology
pub_type: 杂志文章,评审
doi:10.1148/radiol.2313021488
更新日期:2004-06-01 00:00:00
abstract::Least-squares regression analysis was computerized to provide functional color images of myocardial perfusion patterns. In 8 of the 9 patients studied, changes in pattern indicated that the revascularization procedure speeded the appearance time and/or net rate of 43K uptake. The functional images correlated well with...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/114.1.99
更新日期:1975-01-01 00:00:00
abstract::The pathologic specimens and magnetic resonance (MR) images of 53 patients with clinically palpable prostate cancer confined to one lobe were studied to evaluate the ability of MR imaging to depict clinically nonpalpable prostate cancer. All patients had undergone imaging with a 1.5-T imager with T1- and T2-weighted s...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.178.2.1987620
更新日期:1991-02-01 00:00:00
abstract::Patients who have temporomandibular joint (TMJ) clicking and pain are assumed to have an anterior displacement of the meniscus with reduction on opening of the jaw. On the basis of this assumption, these patients are treated nonsurgically with splint therapy. Of 301 TMJs examined, 108 (36%) produced clinically audible...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.154.1.3964930
更新日期:1985-01-01 00:00:00
abstract:PURPOSE:To prospectively compare accuracy of dynamic contrast material-enhanced thin-section multi-detector row helical computed tomography (CT), high-spatial-resolution three-dimensional (3D) dynamic gadolinium-enhanced magnetic resonance (MR) imaging, and superparamagnetic iron oxide (SPIO)-enhanced MR imaging with o...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2371041444
更新日期:2005-10-01 00:00:00
abstract::Positive-mode xeroradiography is an excellent method of visualizing soft-tissue structures in mammography and other procedures; however, toner deletions over a large area may preclude adequate delineation of the soft tissues near high-density structures such as bone. Use of the negative mode in the development cycle p...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/124.3.689
更新日期:1977-09-01 00:00:00
abstract:PURPOSE:To prospectively compare the accuracy of imaging with technetium-99m-labeled Fab' fragment of the anti-carcinoembryonic antigen antibody (CEA) IMMU-4 with that of computed tomography (CT) for the detection of pelvic recurrence of colorectal carcinoma. MATERIALS AND METHODS:In 61 patients, blinded interpretatio...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.197.3.7480740
更新日期:1995-12-01 00:00:00
abstract::Fifty cadaver ankles were examined with ankle tenography. The normal tenographic appearance of the peroneus longus and brevis, posterior tibial, flexor digitorum longus, flexor hallucis longus, anterior tibialis, extensor hallucis longus, and extensor digitorum longus tendons and sheaths are described and illustrated ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.151.3.6718710
更新日期:1984-06-01 00:00:00
abstract::Purpose To evaluate the normal biodistribution and kinetics of (S)-4-(3-[18F]fluoropropyl)-l-glutamic acid ((18)F FSPG) in healthy volunteers and to compare (18)F FSPG mean and maximum standardized uptake values (SUVmean and SUVmax, respectively) with those of (18)F fluorodeoxyglucose (FDG) across a variety of organs....
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2015142000
更新日期:2016-06-01 00:00:00
abstract::Recombinant human tissue-type plasminogen activator (rt-PA) was infused intraarterially at 0.1 mg/kg/h for 1-6 1/2 hours in 25 patients with lower extremity thromboembolic occlusions (13 thrombosed arteries, 12 thrombosed bypass grafts). Occlusion duration ranged from 1 hour to 21 days. Thrombolysis occurred in 23 of ...
journal_title:Radiology
pub_type: 临床试验,杂志文章
doi:10.1148/radiology.160.1.3086930
更新日期:1986-07-01 00:00:00
abstract:PURPOSE:To evaluate the prevalence and appearance of azygos arch valves at intravenous contrast material-enhanced computed tomography (CT). MATERIALS AND METHODS:Findings of 309 intravenous contrast-enhanced spiral CT examinations of the chest were retrospectively reviewed. The presence of contrast material reflux int...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2301021216
更新日期:2004-01-01 00:00:00
abstract::We report qualitative and quantitative evaluation and verification studies of the bipolar phase gradient modulation method for true MR imaging of internal flow and motion velocities. Velocity encoding modulations provide speed-of-motion and direction-sensitive images using special phase-sensitive reconstructions. True...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.154.2.3966130
更新日期:1985-02-01 00:00:00
abstract::Radiographic images can be converted into numerical sequences that can be evalueate by computer to determine the significance of certain radiographic findings in peripheral pulmonary nodules. Of three methods (discriminant analysis. Bayes' theoroem, and the Calm system), discriminant analysis has proven the best with ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/125.3.583
更新日期:1977-12-01 00:00:00
abstract:PURPOSE:To clarify the computed tomographic (CT) features of focal organizing pneumonia. MATERIALS AND METHODS:The authors retrospectively studied CT scans of 18 patients with histologically proved focal organizing pneumonia. Chest radiographs in all 18 patients suggested bronchogenic carcinoma. RESULTS:Seventeen of ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.189.1.8372180
更新日期:1993-10-01 00:00:00
abstract:PURPOSE:To assess the feasibility of automatic needle-guide tracking by using a real-time phase-only cross correlation ( POCC phase-only cross correlation ) algorithm-based sequence for transrectal 3-T in-bore magnetic resonance (MR)-guided prostate biopsies. MATERIALS AND METHODS:This study was approved by the ethics...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.14132067
更新日期:2014-12-01 00:00:00
abstract:PURPOSE:To determine whether systematically evaluated criteria for probably benign lesions were actually applied to lesions placed into that category. MATERIALS AND METHODS:A search of the mammography database yielded 295 cases that were initially followed up with short-term interval mammography but eventually receive...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2231011355
更新日期:2002-04-01 00:00:00
abstract:PURPOSE:To determine the diagnostic accuracy of ultrasonographically (US) and stereotactically guided fine-needle aspiration biopsy (FNAB) in the diagnosis of nonpalpable breast lesions. MATERIALS AND METHODS:At 18 institutions, 442 women who underwent 22-25-gauge imaging-guided FNAB were enrolled. Definitive surgical...
journal_title:Radiology
pub_type: 临床试验,杂志文章,多中心研究,随机对照试验
doi:10.1148/radiology.219.3.r01jn28785
更新日期:2001-06-01 00:00:00