MR-compatible assistance system for biopsy in a high-field-strength system: initial results in patients with suspicious prostate lesions.

Abstract:

PURPOSE:To examine the feasibility and safety of magnetic resonance (MR)-guided biopsy by using a transgluteal approach in patients with suspicious prostate lesions by using an MR-compatible robotic system and a 1.5-T MR system. MATERIALS AND METHODS:The study was approved by the institutional review board of University Frankfurt, and informed consent was obtained from each patient. A total of 20 patients (age range, 57.8-71.9 years; mean age, 65.1 years) underwent biopsy in a closed-bore high-field-strength MR system. Biopsy was performed with an MR-compatible pneumatically driven robotic system. T1-weighted gradient-echo fast low-angle shot and T2-weighted true fast imaging with steady-state precession sequences were used to plan and guide the intervention with a transgluteal access on the external planning computer of the assistance system. The system calculated the trajectory and then moved the guiding arm to the insertion point. The cannula was advanced manually, and biopsies were performed with the coaxial technique by using a 15-gauge pencil tip needle. Intervention time, complications, and biopsy findings were documented. RESULTS:The MR-compatible robotic system did not interfere with image quality, nor did MR imaging cause dysfunction of the robot. In one patient, the interventionist caused a fail-safe system shutdown. This was due to inadvertent displacement of the guiding arm during cannula insertion. This problem was solved by increasing the displacement threshold. Accurate coaxial cannula biopsy could be performed in all subsequent patients. Sufficient histopathologic assessment was performed in 19 patients. Insufficient material was retrieved in the patient who experienced fail-safe system shutdown. The median intervention time was 39 minutes (23-65 minutes). No procedure-related complications were observed. CONCLUSION:Preliminary results indicate that MR-guided robot-assisted biopsy is feasible and can be performed safely with highly accurate cannula placement.

journal_name

Radiology

journal_title

Radiology

authors

Zangos S,Melzer A,Eichler K,Sadighi C,Thalhammer A,Bodelle B,Wolf R,Gruber-Rouh T,Proschek D,Hammerstingl R,Müller C,Mack MG,Vogl TJ

doi

10.1148/radiol.11101559

subject

Has Abstract

pub_date

2011-06-01 00:00:00

pages

903-10

issue

3

eissn

0033-8419

issn

1527-1315

pii

radiol.11101559

journal_volume

259

pub_type

杂志文章
  • Case 281: Thoracic Air Leak Syndrome in a Patient with Hematopoietic Stem Cell Transplantation and Graft-versus-Host Disease.

    abstract::HistoryAn 18-year-old man was diagnosed with precursor B-cell lymphoblastic leukemia and underwent transplantation of hematopoietic stem cells from his human leukocyte antigen-matched sister 1 year prior to admission. He was admitted to evaluate progressive shortness of breath and dry cough of 1-month duration. He did...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2020182477

    authors: Khoshbin AP,Aliannejad R

    更新日期:2020-09-01 00:00:00

  • The effects of nuclear magnetic resonance on patients with cardiac pacemakers.

    abstract::The effect of nuclear magnetic resonance (NMR) imaging on six representative cardiac pacemakers was studied. The results indicate that the threshold for initiating the asynchronous mode of a pacemaker is 17 gauss. Radiofrequency levels are present in an NMR unit and may confuse or possibly inhibit demand pacemakers, a...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.147.1.6828720

    authors: Pavlicek W,Geisinger M,Castle L,Borkowski GP,Meaney TF,Bream BL,Gallagher JH

    更新日期:1983-04-01 00:00:00

  • CT perfusion scanning with deconvolution analysis: pilot study in patients with acute middle cerebral artery stroke.

    abstract:PURPOSE:To measure mean cerebral blood flow (CBF) in ischemic and nonischemic territories and in low-attenuation regions in patients with acute stroke by using deconvolution-derived hemodynamic imaging. MATERIALS AND METHODS:Twelve patients with acute middle cerebral artery stroke and 12 control patients were examined...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2221010471

    authors: Eastwood JD,Lev MH,Azhari T,Lee TY,Barboriak DP,Delong DM,Fitzek C,Herzau M,Wintermark M,Meuli R,Brazier D,Provenzale JM

    更新日期:2002-01-01 00:00:00

  • Microwave ablation with multiple simultaneously powered small-gauge triaxial antennas: results from an in vivo swine liver model.

    abstract:PURPOSE:To prospectively investigate the ability of a single generator to power multiple small-diameter antennas and create large zones of ablation in an in vivo swine liver model. MATERIALS AND METHODS:Thirteen female domestic swine (mean weight, 70 kg) were used for the study as approved by the animal care and use c...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2441052054

    authors: Brace CL,Laeseke PF,Sampson LA,Frey TM,van der Weide DW,Lee FT Jr

    更新日期:2007-07-01 00:00:00

  • Amyloidosis of heart and liver: comparison of Tc-99m pyrophosphate and Tc-99m methylene diphosphonate for detection.

    abstract::A prospective, comparative study was made of the efficacy of technetium-99m pyrophosphate (Tc PYP) and technetium-99m methylene diphosphonate (Tc MDP) in detecting soft-tissue amyloidosis. Tc PYP and Tc MDP scans were obtained within ten-day intervals in seven patients with histologically proven amyloidosis. Tc PYP wa...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.148.1.6304810

    authors: Lee VW,Caldarone AG,Falk RH,Rubinow A,Cohen AS

    更新日期:1983-07-01 00:00:00

  • MR imaging of apparent small-bowel perfusion for diagnosing mesenteric ischemia: feasibility study.

    abstract::The purpose of this study, which was approved by the institutional review board, was to assess the differentiation of individuals with from those without mesenteric ischemia. All subjects provided written informed consent. Six healthy volunteers and six patients with documented chronic mesenteric ischemia underwent ma...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2342031002

    authors: Lauenstein TC,Ajaj W,Narin B,Göhde SC,Kröger K,Debatin JF,Rühm SG

    更新日期:2005-02-01 00:00:00

  • Existence of the diffusion-perfusion mismatch within 24 hours after onset of acute stroke: dependence on proximal arterial occlusion.

    abstract:PURPOSE:To assess the existence of a mismatch between lesions on diffusion-weighted (DW) and perfusion-weighted (PW) magnetic resonance (MR) images obtained within 24 hours after onset of acute stroke and to use mismatch data and angiographic evidence of proximal arterial occlusion (PAO) to investigate whether the exis...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2503080811

    authors: Copen WA,Rezai Gharai L,Barak ER,Schwamm LH,Wu O,Kamalian S,Gonzalez RG,Schaefer PW

    更新日期:2009-03-01 00:00:00

  • Medical physics: some recollections in diagnostic X-ray imaging and therapeutic radiology.

    abstract::Medical physics has changed dramatically since 1895. There was a period of slow evolutionary change during the first 70 years after Roentgen's discovery of x rays. With the advent of the computer, however, both diagnostic and therapeutic radiology have undergone rapid growth and changes. Technologic advances such as c...

    journal_title:Radiology

    pub_type: 历史文章,杂志文章

    doi:10.1148/radiology.217.3.r00dc36619

    authors: Gray JE,Orton CG

    更新日期:2000-12-01 00:00:00

  • Anatomic features of the carpal scaphoid: validation of biometric measurements and symmetry with three-dimensional MR imaging.

    abstract::The goals of reconstructive surgery for scaphoid fracture nonunions include restoration of normal scaphoid length and shape by use of the contralateral scaphoid bone as a geometric model. A literature search revealed limited documentation of normal biometric measurements and no validation of scaphoid anatomic symmetry...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.187.1.8451410

    authors: Smith DK

    更新日期:1993-04-01 00:00:00

  • Quantitation of emphysema with three-dimensional CT densitometry: comparison with two-dimensional analysis, visual emphysema scores, and pulmonary function test results.

    abstract:PURPOSE:To compare lung densitometric measurements that use a three-dimensional (3D) reconstruction of the lungs with those obtained from analysis of two-dimensional (2D) computed tomographic (CT) images, visual emphysema scores, and data from pulmonary function tests. MATERIALS AND METHODS:Thoracic helical CT scans w...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.211.2.r99ma52541

    authors: Park KJ,Bergin CJ,Clausen JL

    更新日期:1999-05-01 00:00:00

  • Rheumatoid arthritis of the cervical spine: early and progressive radiographic features.

    abstract::One hundred thirty-three cervical spine radiographs of 50 patients with rheumatoid arthritis were examined. The patients were a representative random sample chosen from among 675 patients followed up for more than 10 years. The frequency of occurrence for each radiographic finding was correlated with the duration of r...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.165.1.3628760

    authors: Wolfe BK,O'Keeffe D,Mitchell DM,Tchang SP

    更新日期:1987-10-01 00:00:00

  • Craniosynostosis: correlation of bone scans, radiographs, and surgical findings.

    abstract::Skull scintigraphy was performed in 68 children with suspected craniosynostosis after injection of technetium-99m methylene diphosphonate. The scans demonstrated four patterns of sutural activity: normal, absent, increased, and wide. When correlated with surgical findings, "absent" indicated fused sutures, "increased"...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/133.3.615

    authors: Tait MV,Gilday DL,Ash JM,Boldt DJ,Harwood-Nash DC,Fitz CR,Barry J

    更新日期:1979-12-01 00:00:00

  • The round nipple shadow.

    abstract::It is usually easy to distinguish the round nipple shadow from a lesion, especially by means of repeat radiographs with nipple markers. However, the radiologist must occasionally interpret a round density in the lower chest on the basis of a single radiograph or series of radiographs. Fortunately, a nipple shadow usua...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/121.2.293

    authors: Ferris RA,White AF

    更新日期:1976-11-01 00:00:00

  • Cerebral perfusion CT: technique and clinical applications.

    abstract::Perfusion computed tomography (CT) is a relatively new technique that allows rapid qualitative and quantitative evaluation of cerebral perfusion by generating maps of cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT). The technique is based on the central volume principle (CBF = CBV/M...

    journal_title:Radiology

    pub_type: 杂志文章,评审

    doi:10.1148/radiol.2313021488

    authors: Hoeffner EG,Case I,Jain R,Gujar SK,Shah GV,Deveikis JP,Carlos RC,Thompson BG,Harrigan MR,Mukherji SK

    更新日期:2004-06-01 00:00:00

  • Atraumatic evaluation of myocardial revascularization procedures with 43K1.

    abstract::Least-squares regression analysis was computerized to provide functional color images of myocardial perfusion patterns. In 8 of the 9 patients studied, changes in pattern indicated that the revascularization procedure speeded the appearance time and/or net rate of 43K uptake. The functional images correlated well with...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/114.1.99

    authors: Smith RO,Bennett KR,Suzuki A,Lehan PH,Hellems HK

    更新日期:1975-01-01 00:00:00

  • Nonpalpable prostate cancer: detection with MR imaging.

    abstract::The pathologic specimens and magnetic resonance (MR) images of 53 patients with clinically palpable prostate cancer confined to one lobe were studied to evaluate the ability of MR imaging to depict clinically nonpalpable prostate cancer. All patients had undergone imaging with a 1.5-T imager with T1- and T2-weighted s...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.178.2.1987620

    authors: Carter HB,Brem RF,Tempany CM,Yang A,Epstein JI,Walsh PC,Zerhouni EA

    更新日期:1991-02-01 00:00:00

  • Temporomandibular joint clicking with nonreducing anterior displacement of the meniscus.

    abstract::Patients who have temporomandibular joint (TMJ) clicking and pain are assumed to have an anterior displacement of the meniscus with reduction on opening of the jaw. On the basis of this assumption, these patients are treated nonsurgically with splint therapy. Of 301 TMJs examined, 108 (36%) produced clinically audible...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.154.1.3964930

    authors: Miller TL,Katzberg RW,Tallents RH,Bessette RW,Hayakawa K

    更新日期:1985-01-01 00:00:00

  • Liver metastases in candidates for hepatic resection: comparison of helical CT and gadolinium- and SPIO-enhanced MR imaging.

    abstract:PURPOSE:To prospectively compare accuracy of dynamic contrast material-enhanced thin-section multi-detector row helical computed tomography (CT), high-spatial-resolution three-dimensional (3D) dynamic gadolinium-enhanced magnetic resonance (MR) imaging, and superparamagnetic iron oxide (SPIO)-enhanced MR imaging with o...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2371041444

    authors: Ward J,Robinson PJ,Guthrie JA,Downing S,Wilson D,Lodge JP,Prasad KR,Toogood GJ,Wyatt JI

    更新日期:2005-10-01 00:00:00

  • Negative-mode soft-tissue xeroradiography.

    abstract::Positive-mode xeroradiography is an excellent method of visualizing soft-tissue structures in mammography and other procedures; however, toner deletions over a large area may preclude adequate delineation of the soft tissues near high-density structures such as bone. Use of the negative mode in the development cycle p...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/124.3.689

    authors: Osterman FA Jr,Zeman GH,Rao GU,Gayler B,Kirk BG,James AE Jr

    更新日期:1977-09-01 00:00:00

  • Detection of pelvic recurrence of colorectal carcinoma: prospective, blinded comparison of Tc-99m-IMMU-4 monoclonal antibody scanning and CT.

    abstract:PURPOSE:To prospectively compare the accuracy of imaging with technetium-99m-labeled Fab' fragment of the anti-carcinoembryonic antigen antibody (CEA) IMMU-4 with that of computed tomography (CT) for the detection of pelvic recurrence of colorectal carcinoma. MATERIALS AND METHODS:In 61 patients, blinded interpretatio...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.197.3.7480740

    authors: Stomper PC,D'Souza DJ,Bakshi SP,Rodriguez-Bigas M,Burke PA,Petrelli NJ

    更新日期:1995-12-01 00:00:00

  • Ankle tenography: a key to unexplained symptomatology. Part I: Normal tenographic anatomy.

    abstract::Fifty cadaver ankles were examined with ankle tenography. The normal tenographic appearance of the peroneus longus and brevis, posterior tibial, flexor digitorum longus, flexor hallucis longus, anterior tibialis, extensor hallucis longus, and extensor digitorum longus tendons and sheaths are described and illustrated ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.151.3.6718710

    authors: Teng MM,Destouet JM,Gilula LA,Resnick D,Hembree JL,Oloff LM

    更新日期:1984-06-01 00:00:00

  • Characterization of Physiologic (18)F FSPG Uptake in Healthy Volunteers.

    abstract::Purpose To evaluate the normal biodistribution and kinetics of (S)-4-(3-[18F]fluoropropyl)-l-glutamic acid ((18)F FSPG) in healthy volunteers and to compare (18)F FSPG mean and maximum standardized uptake values (SUVmean and SUVmax, respectively) with those of (18)F fluorodeoxyglucose (FDG) across a variety of organs....

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015142000

    authors: Mosci C,Kumar M,Smolarz K,Koglin N,Stephens AW,Schwaiger M,Gambhir SS,Mittra ES

    更新日期:2016-06-01 00:00:00

  • Recombinant human tissue-type plasminogen activator for thrombolysis in peripheral arteries and bypass grafts.

    abstract::Recombinant human tissue-type plasminogen activator (rt-PA) was infused intraarterially at 0.1 mg/kg/h for 1-6 1/2 hours in 25 patients with lower extremity thromboembolic occlusions (13 thrombosed arteries, 12 thrombosed bypass grafts). Occlusion duration ranged from 1 hour to 21 days. Thrombolysis occurred in 23 of ...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章

    doi:10.1148/radiology.160.1.3086930

    authors: Risius B,Graor RA,Geisinger MA,Zelch MG,Lucas FV,Young JR,Grossbard EB

    更新日期:1986-07-01 00:00:00

  • Azygos arch valves: prevalence and appearance at contrast-enhanced CT.

    abstract:PURPOSE:To evaluate the prevalence and appearance of azygos arch valves at intravenous contrast material-enhanced computed tomography (CT). MATERIALS AND METHODS:Findings of 309 intravenous contrast-enhanced spiral CT examinations of the chest were retrospectively reviewed. The presence of contrast material reflux int...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2301021216

    authors: Yeh BM,Coakley FV,Sanchez HC,Wilson MW,Reddy GP,Gotway MB

    更新日期:2004-01-01 00:00:00

  • Verification and evaluation of internal flow and motion. True magnetic resonance imaging by the phase gradient modulation method.

    abstract::We report qualitative and quantitative evaluation and verification studies of the bipolar phase gradient modulation method for true MR imaging of internal flow and motion velocities. Velocity encoding modulations provide speed-of-motion and direction-sensitive images using special phase-sensitive reconstructions. True...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.154.2.3966130

    authors: Moran PR,Moran RA,Karstaedt N

    更新日期:1985-02-01 00:00:00

  • Results of computer-aided diagnosis of peripheral bronchial carcinoma.

    abstract::Radiographic images can be converted into numerical sequences that can be evalueate by computer to determine the significance of certain radiographic findings in peripheral pulmonary nodules. Of three methods (discriminant analysis. Bayes' theoroem, and the Calm system), discriminant analysis has proven the best with ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/125.3.583

    authors: Rotte KH,Meiske W

    更新日期:1977-12-01 00:00:00

  • Focal organizing pneumonia: CT appearance.

    abstract:PURPOSE:To clarify the computed tomographic (CT) features of focal organizing pneumonia. MATERIALS AND METHODS:The authors retrospectively studied CT scans of 18 patients with histologically proved focal organizing pneumonia. Chest radiographs in all 18 patients suggested bronchogenic carcinoma. RESULTS:Seventeen of ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.189.1.8372180

    authors: Kohno N,Ikezoe J,Johkoh T,Takeuchi N,Tomiyama N,Kido S,Kondoh H,Arisawa J,Kozuka T

    更新日期:1993-10-01 00:00:00

  • Automated real-time needle-guide tracking for fast 3-T MR-guided transrectal prostate biopsy: a feasibility study.

    abstract:PURPOSE:To assess the feasibility of automatic needle-guide tracking by using a real-time phase-only cross correlation ( POCC phase-only cross correlation ) algorithm-based sequence for transrectal 3-T in-bore magnetic resonance (MR)-guided prostate biopsies. MATERIALS AND METHODS:This study was approved by the ethics...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.14132067

    authors: Zamecnik P,Schouten MG,Krafft AJ,Maier F,Schlemmer HP,Barentsz JO,Bock M,Fütterer JJ

    更新日期:2014-12-01 00:00:00

  • Malignant lesions initially subjected to short-term mammographic follow-up.

    abstract:PURPOSE:To determine whether systematically evaluated criteria for probably benign lesions were actually applied to lesions placed into that category. MATERIALS AND METHODS:A search of the mammography database yielded 295 cases that were initially followed up with short-term interval mammography but eventually receive...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2231011355

    authors: Rosen EL,Baker JA,Soo MS

    更新日期:2002-04-01 00:00:00

  • Fine-needle aspiration biopsy of nonpalpable breast lesions in a multicenter clinical trial: results from the radiologic diagnostic oncology group V.

    abstract:PURPOSE:To determine the diagnostic accuracy of ultrasonographically (US) and stereotactically guided fine-needle aspiration biopsy (FNAB) in the diagnosis of nonpalpable breast lesions. MATERIALS AND METHODS:At 18 institutions, 442 women who underwent 22-25-gauge imaging-guided FNAB were enrolled. Definitive surgical...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1148/radiology.219.3.r01jn28785

    authors: Pisano ED,Fajardo LL,Caudry DJ,Sneige N,Frable WJ,Berg WA,Tocino I,Schnitt SJ,Connolly JL,Gatsonis CA,McNeil BJ

    更新日期:2001-06-01 00:00:00