CT perfusion scanning with deconvolution analysis: pilot study in patients with acute middle cerebral artery stroke.

Abstract:

PURPOSE:To measure mean cerebral blood flow (CBF) in ischemic and nonischemic territories and in low-attenuation regions in patients with acute stroke by using deconvolution-derived hemodynamic imaging. MATERIALS AND METHODS:Twelve patients with acute middle cerebral artery stroke and 12 control patients were examined by using single-section computed tomography (CT) perfusion scanning. Analysis was performed with a deconvolution-based algorithm. Comparisons of mean CBF, cerebral blood volume (CBV), and mean transit time (MTT) were determined between hemispheres in all patients and between low- and normal-attenuation regions in patients with acute stroke. Two independent readers examined the images for extent of visually apparent regional perfusion abnormalities. The data were compared with extent of final infarct in seven patients with acute stroke who underwent follow-up CT or magnetic resonance imaging. RESULTS:Significant decreases in CBF (-50%, P =.001) were found in the affected hemispheres of patients with acute stroke. Significant changes in CBV (-26%, P =.03) and MTT (+111%, P =.004) were also seen. Significant alterations in perfusion were also seen in low- compared with normal-attenuation areas. Pearson correlation between readers for extent of CBF abnormality was 0.94 (P =.001). Intraobserver variation was 8.9% for CBF abnormalities. CONCLUSION:Deconvolution analysis of CT perfusion data is a promising method for evaluation of cerebral hemodynamics in patients with acute stroke.

journal_name

Radiology

journal_title

Radiology

authors

Eastwood JD,Lev MH,Azhari T,Lee TY,Barboriak DP,Delong DM,Fitzek C,Herzau M,Wintermark M,Meuli R,Brazier D,Provenzale JM

doi

10.1148/radiol.2221010471

subject

Has Abstract

pub_date

2002-01-01 00:00:00

pages

227-36

issue

1

eissn

0033-8419

issn

1527-1315

journal_volume

222

pub_type

杂志文章
  • Pulmonary embolus: detection and follow-up using magnetic resonance.

    abstract::Magnetic resonance imaging (MRI) of an angiographically confirmed pulmonary embolus was performed. The thrombus appeared as an intense intraluminal signal within the left descending pulmonary artery; this signal was absent on repeat examination after clot lysis. Because MR will not image flowing blood, it provides a p...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.153.2.6484180

    authors: Moore EH,Gamsu G,Webb WR,Stulbarg MS

    更新日期:1984-11-01 00:00:00

  • Diagnostic ultrasound exposure in man.

    abstract::In his review of the AAPM statement on ultrasound, the author feels that allowing "some" research or demonstration on normal persons in the face of cautionary statements on as yet unknown side effects is an inconsistent position. The use of videotapes and the development of simulators hacked by data banks are offered...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/116.3.739

    authors: Gramiak R

    更新日期:1975-09-01 00:00:00

  • Metastatic prostate cancer: initial findings of PET with 2-deoxy-2-[F-18]fluoro-D-glucose.

    abstract:PURPOSE:To evaluate the accuracy of positron emission tomography (PET) with 2-deoxy-2-[fluorine-18] fluoro-D-glucose (FDG) in the detection of osseous and soft-tissue metastases of prostate cancer. MATERIALS AND METHODS:Thirty-four patients (mean age, 71 years) with biopsy-proved prostate cancer and known or suspected...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.199.3.8638000

    authors: Shreve PD,Grossman HB,Gross MD,Wahl RL

    更新日期:1996-06-01 00:00:00

  • Cervical spine: three-dimensional MR imaging with magnetization transfer prepulsed turbo field echo techniques.

    abstract::In 11 volunteers, magnetic resonance (MR) imaging of the cervical spine was performed with a magnetization transfer preparatory pulse (prepulsed), three-dimensional Fourier transform, turbo field echo sequence. The effects of flip angle, number of shots, phase-encoding profile order, and magnetization transfer prepuls...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.207.3.9609910

    authors: Melhem ER,Caruthers SD,Jara H

    更新日期:1998-06-01 00:00:00

  • Prediction of Hip Failure Load: In Vitro Study of 80 Femurs Using Three Imaging Methods and Finite Element Models-The European Fracture Study (EFFECT).

    abstract::Purpose To evaluate the performance of three imaging methods (radiography, dual-energy x-ray absorptiometry [DXA], and quantitative computed tomography [CT]) and that of a numerical analysis with finite element modeling (FEM) in the prediction of failure load of the proximal femur and to identify the best densitometri...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2016142796

    authors: Pottecher P,Engelke K,Duchemin L,Museyko O,Moser T,Mitton D,Vicaut E,Adams J,Skalli W,Laredo JD,Bousson V

    更新日期:2016-09-01 00:00:00

  • Dynamic computed tomography in the evaluation of vascular lung lesions.

    abstract::Rapid sequence (dynamic) computed tomography (CT) following the bolus injection of contrast material into a peripheral vein allows a differentiation of vascular and nonvascular lung lesions. The use of time-density curves plotting the changing CT number over time also allows pulmonary arterial supply of lung lesions t...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.138.3.7465840

    authors: Godwin JD,Webb WR

    更新日期:1981-03-01 00:00:00

  • Case 241: Hemiparkinsonism- Hemiatrophy-SPECT with 99mTc TRODAT-1 and Muscle MR Imaging Abnormalities.

    abstract::History A 43-year-old right-handed man presented with a history of progressive mild left-sided weakness and slowness of movements. Symptoms began 4 years earlier, and the patient noticed a progressive decline in his daily routine due to gait difficulties in the past year. There was no history of head trauma, surgery, ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2017151717

    authors: Vale TC,de Lima Pinto FC,Pedroso JL,Alves Dos Reis M,Batista IR,Affonseca Bressan R,Magalhães Rivero RL,Mendonça RA,Barsottini OG

    更新日期:2017-05-01 00:00:00

  • Radionuclide studies of chronic schistosomal uropathy.

    abstract::Fifty patients with chronic urinary tract schistosomiasis were studied with 99mTc-DTPA. All had a flow study, sequential analog imaging, and digital imaging for 25-35 minutes (20-sec. frames). Time-activity curves (DTPA renograms) were extracted; 12 patients had 131I-Hippuran probe renograms as well. Renal changes inc...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.140.2.7019960

    authors: Lamki LM,Lamki N

    更新日期:1981-08-01 00:00:00

  • Healing of lytic Paget bone disease with diphosphonate therapy.

    abstract::In a patient with Paget disease, two of three lytic fronts ("blade-of-grass" lesions) healed according to radiologic criteria during intermittent diphosphonate therapy. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.134.3.7355210

    authors: Murphy WA,Whyte MP,Haddad JG Jr

    更新日期:1980-03-01 00:00:00

  • Impassable ureteral strictures: management with percutaneous ureteroneocystostomy.

    abstract::Sixteen of 227 patients referred for percutaneous placement of a ureteral stent had impassable stenoses. Stenoses were benign (n = 8) or attributed to malignant retroperitoneal neoplasm (n = 8). Electrocautery was used to create a neotract between the stenosed ureter and the bladder or ileal loop. A double-J stent was...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.180.2.2068310

    authors: Cornud FE,Casanova JM,Bonnel DH,Helenon OR,Hanna SM,Chretien YR,Dufour BF,Moreau JF

    更新日期:1991-08-01 00:00:00

  • Prostate cancer: precision of integrating functional MR imaging with radiation therapy treatment by using fiducial gold markers.

    abstract::The use of intensity-modulated radiation therapy for treatment of dominant intraprostatic lesions may require integration of functional magnetic resonance (MR) imaging with treatment-planning computed tomography (CT). The purpose of this study was to compare prospectively the landmark and iterative closest point metho...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2361040560

    authors: Huisman HJ,Fütterer JJ,van Lin EN,Welmers A,Scheenen TW,van Dalen JA,Visser AG,Witjes JA,Barentsz JO

    更新日期:2005-07-01 00:00:00

  • Malignant ureteral obstruction: treatment with metal stents--technique, results, and observations with percutaneous intraluminal US.

    abstract:PURPOSE:To test the technical feasibility and results of placement of metal stents into ureters obstructed by extensive tumor. MATERIALS AND METHODS:Six consecutive patients (two men and four women, aged 35-66 years and with incurable malignancies) underwent insertion of metallic endoprostheses in nine obstructed uret...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.191.3.8184060

    authors: vanSonnenberg E,D'Agostino HB,O'Laoide R,Donaldson J,Sanchez RB,Hoyt A,Pittman CC

    更新日期:1994-06-01 00:00:00

  • Clear cell chondrosarcoma.

    abstract::The clinical, radiologic, and histopathologic features of three cases of clear cell chondrosarcoma are described. On radiographs, this rather benign-appearing tumor resembles a chondroblastoma when it occurs at the end of a long bone, and may occasionally show a calcified matrix. However, it has distinctive tumor cell...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.154.1.3964950

    authors: Kumar R,David R,Cierney G 3rd

    更新日期:1985-01-01 00:00:00

  • Display of CT studies on a two-screen electronic workstation versus a film panel alternator: sensitivity and efficiency among radiologists.

    abstract::Prototype electronic workstations incorporated in networks linking computed tomographic (CT) and magnetic resonance imaging systems are being developed. The authors compared observer efficiency and sensitivity in reading body CT studies from a two-screen workstation (1,000-line monitors and 12-bit dynamic range in ima...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.174.3.2305060

    authors: Foley WD,Jacobson DR,Taylor AJ,Goodman LR,Stewart ET,Gurney JW,Stroka D

    更新日期:1990-03-01 00:00:00

  • Splenic vein thrombosis after splenectomy: frequency and role of imaging.

    abstract:PURPOSE:To assess the frequency of splenic vein thrombosis (SVT) after splenectomy and its consequences on patient treatment. MATERIALS AND METHODS:A group of 183 consecutive patients who underwent splenectomy were evaluated. Of these patients, 119 underwent postoperative ultrasound (US) or computed tomography. RESUL...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.190.1.8259430

    authors: Petit P,Bret PM,Atri M,Hreno A,Casola G,Gianfelice D

    更新日期:1994-01-01 00:00:00

  • Lead arthropathy: arthritis caused by retained intra-articular bullets.

    abstract::The cases of 14 patients seen 6 weeks to 7 years after gunshot wounds with painful, restrictive joint disease and retained intra-articular bullets were reviewed. Twelve patients had radiographic findings characteristic of lead synovitis. The earliest finding was a fine, punctate deposition of radiopaque lead on the ar...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.156.2.4011890

    authors: Sclafani SJ,Vuletin JC,Twersky J

    更新日期:1985-08-01 00:00:00

  • Resolution of intracranial calcifications in infants with treated congenital toxoplasmosis.

    abstract:PURPOSE:To determine the natural history of intracranial calcifications in infants with treated congenital toxoplasmosis. MATERIALS AND METHODS:Between January 1982 and March 1994, cranial computed tomography was performed in 56 infants with treated congenital toxoplasmosis when they were newborns and approximately 1 ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.199.2.8668790

    authors: Patel DV,Holfels EM,Vogel NP,Boyer KM,Mets MB,Swisher CN,Roizen NJ,Stein LK,Stein MA,Hopkins J,Withers SE,Mack DG,Luciano RA,Meier P,Remington JS,McLeod RL

    更新日期:1996-05-01 00:00:00

  • Will hyperthermia conquer the elusive hypoxic cell? Implications of heat effects on tumor and normal-tissue microcirculation.

    abstract::In tumor radiobiology, the hypoxic cell has become especially important because of recent evidence of acute hypoxic regions within experimental tumors. The impact of hyperthermia on the development of acute hypoxia is discussed. Two experiments for studying hyperthermia and hypoxia in tumors are presented. Knowledge o...

    journal_title:Radiology

    pub_type: 杂志文章,评审

    doi:10.1148/radiology.137.3.7003650

    authors: Dewhirst MW,Ozimek EJ,Gross J,Cetas TC

    更新日期:1980-12-01 00:00:00

  • Transcatheter occlusion of pulmonary arterial circulation and collateral supply: failures, incidents, and complications.

    abstract::Failures and complications were analyzed retrospectively in 45 patients treated with embolotherapy or occlusion of pulmonary arterial circulation. Pulmonary arterial branches were occluded with steel coils in 19 patients with pulmonary arteriovenous malformations, 17 with hemoptysis of pulmonary artery (PA) origin, an...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.180.3.1871280

    authors: Remy-Jardin M,Wattinne L,Remy J

    更新日期:1991-09-01 00:00:00

  • Uterine artery embolization in sheep: comparison of acute effects with polyvinyl alcohol particles and calibrated microspheres.

    abstract:PURPOSE:To compare the effects on the myometrium of polyvinyl alcohol (PVA) particles and calibrated microspheres (MS) in embolization of the uterine arteries in sheep. MATERIALS AND METHODS:Superselective and bilateral embolization of the uterine arteries was performed with PVA particles and calibrated MS within 24 h...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2242010847

    authors: Pelage JP,Laurent A,Wassef M,Bonneau M,Germain D,Rymer R,Flaud P,Martal J,Merland JJ

    更新日期:2002-08-01 00:00:00

  • Percutaneous adrenal biopsy: review of a 10-year experience.

    abstract:PURPOSE:To evaluate the indications for and complications, accuracy, and techniques of percutaneous adrenal biopsy performed from 1982 through 1991 at the authors' institution. MATERIALS AND METHODS:Two hundred seventy-seven percutaneous adrenal biopsies were performed in 270 patients (175 male and 102 female patients...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.193.2.7972740

    authors: Welch TJ,Sheedy PF 2nd,Stephens DH,Johnson CM,Swensen SJ

    更新日期:1994-11-01 00:00:00

  • Paget disease with contraction of long bones.

    abstract::The evolution of Paget disease characterized both by expansion and subsequent contraction of the long bones of the ipsilateral upper extremity over a 10-year period is described. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.159.2.3961180

    authors: Lander PH,Hadjipavlou AG

    更新日期:1986-05-01 00:00:00

  • A prospective study of computed tomography and ultrasound in the detection and staging of pelvic masses.

    abstract::Findings from computed tomography (CT) and ultrasound (US) examinations of 74 patients who were clinically thought to have pelvic masses and of 110 patients who had possible recurrence of pelvic tumors were analyzed. There was no significant difference in the ability of the two modalities to identify masses or to pred...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.146.2.6849090

    authors: Sanders RC,McNeil BJ,Finberg HJ,Hessel SJ,Siegelman SS,Adams DF,Alderson PO,Abrams HL

    更新日期:1983-02-01 00:00:00

  • Scimitar syndrome: four new cases examined with CT.

    abstract::Four new cases of scimitar syndrome illustrate the complex derangement of the right lung architecture. Computed tomography (CT) helped in demonstrating the hyparterial relationship of the right bronchus to the pulmonary artery, the course and termination of the scimitar vein, the mediastinal shift, unusual fissures, a...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.159.1.3952300

    authors: Godwin JD,Tarver RD

    更新日期:1986-04-01 00:00:00

  • Molecular body imaging: MR imaging, CT, and US. part I. principles.

    abstract::Molecular imaging, generally defined as noninvasive imaging of cellular and subcellular events, has gained tremendous depth and breadth as a research and clinical discipline in recent years. The coalescence of major advances in engineering, molecular biology, chemistry, immunology, and genetics has fueled multi- and i...

    journal_title:Radiology

    pub_type: 杂志文章,评审

    doi:10.1148/radiol.12102394

    authors: Kircher MF,Willmann JK

    更新日期:2012-06-01 00:00:00

  • Subjective vs. objective evaluation of gallbladder opacification during oral cholecystography in comparative clinical trials: implications for studies involving visual assessment.

    abstract::Radiographs and CT images taken during oral cholecystography in dogs were interpreted in an independent, blind fashion by three radiologists on two occasions and visual assessment of gallbladder density compared to the actual CT values. While there was significant intra- and inter-observer variation, the mean scores f...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.144.2.7089280

    authors: Fon GT,Hunter TB,Berk RN,Patton DD,Capp MP

    更新日期:1982-07-01 00:00:00

  • Breast cancers: noninvasive method of preoperative localization with three-dimensional US and surface contour mapping.

    abstract::Formal ethical approval was granted by the local research ethics committee; all participants gave written consent. The purpose of the study was to prospectively evaluate the feasibility of a noninvasive method of breast tumor localization in 25 participants, based on the coregistration of three-dimensional (3D) ultras...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2452060906

    authors: Cash CJ,Coles CE,Treece GM,Purushotham AD,Britton P,Sinnatamby R,Gee AH,Prager RW

    更新日期:2007-11-01 00:00:00

  • Rectal cancer: comparison of accuracy of local-regional staging with two- and three-dimensional preoperative 3-T MR imaging.

    abstract:PURPOSE:To compare the local-regional staging accuracy of the conventional two-dimensional (2D) T2-weighted imaging protocol and of the three-dimensional (3D) T2-weighted imaging protocol for preoperative magnetic resonance (MR) imaging in rectal cancer patients. MATERIALS AND METHODS:This retrospective study was appr...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.09090587

    authors: Kim H,Lim JS,Choi JY,Park J,Chung YE,Kim MJ,Choi E,Kim NK,Kim KW

    更新日期:2010-02-01 00:00:00

  • Arterial MR imaging phase-contrast flow measurement: improvements with varying velocity sensitivity during cardiac cycle.

    abstract::To reduce noise in velocity images of magnetic resonance (MR) phase-contrast measurements, the authors implemented and evaluated a pulse sequence that enables automatic optimization of the velocity-encoding parameter V(enc) for individual heart phases in pulsatile flow on the basis of a rapid prescan. This sequence wa...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2321030783

    authors: Ringgaard S,Oyre SA,Pedersen EM

    更新日期:2004-07-01 00:00:00

  • Role of low-osmolality contrast media in thromboembolic complications: scanning electron microscopy study.

    abstract::Numerous in vitro studies have found that clot formation may occur when blood is mixed directly with nonionic low-osmolality contrast media during angiographic procedures because of activation of hemostasis in the catheter; ionic contrast media, on the other hand, inhibit clot formation. Thirty patients were injected ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.183.3.1584930

    authors: Casalini E