Hemostats, sealants, and adhesives III: a new update as well as cost and regulatory considerations for components of the surgical toolbox.

Abstract:

:The hemostat, sealant, and adhesive components of the surgical toolbox continue to evolve and enter clinical practice at a rapid rate. The goal of this comprehensive, sequential review is to update these components to include those now available (February 2012) as well as to explore cost and regulatory factors that impact the development and use of these materials. A unique system of definitions for organizing these components based on group, category, and class is used as a means of improving the understanding and appropriate use of these materials. The system will be used here to present the most recent additions to the toolbox, which are evaluated based on safety, efficacy, usability, and cost. These new additions include pooled human plasma fibrinogen and thrombin embedded in an equine collagen patch for cardiac surgical hemostasis, polyethylene glycol (PEG) and human serum albumin for lung surgical pneumostasis, modified PEG and trilysine amine for spinal sealing, octyl and butyl lactoyl cyanoacrylate for vascular sealing, and a variety of octyl and butyl cyanoacrylates with or without dyes and/or polyester mesh for skin closure with the creation of a bacterial barrier. The system of definitions will also be used to clarify key strategies in the current health care environment for reducing costs and for increasing understanding of Food and Drug Administration regulatory decisions for these materials.

journal_name

Transfusion

journal_title

Transfusion

authors

Spotnitz WD,Burks S

doi

10.1111/j.1537-2995.2012.03707.x

subject

Has Abstract

pub_date

2012-10-01 00:00:00

pages

2243-55

issue

10

eissn

0041-1132

issn

1537-2995

journal_volume

52

pub_type

杂志文章,评审
  • Continuous- and semicontinuous-flow blood centrifugation systems: therapeutic applications, with plasma-, platelet, lympha-, and eosinapheresis.

    abstract::Blood centrifugation, with a continuous-flow or semicontinuous-flow system, was used in the treatment of 17 patients with various hematologic disorders. Total plasma exchange (TPE) controlled symptoms of hyperviscosity and arrested bleeding in three patients. In two patients, TPE made is possible to perform urgent sur...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1977.17578014576.x

    authors: Pineda AA,Brzica SM Jr,Taswell HF

    更新日期:1977-09-01 00:00:00

  • RUNX1 mutation in a patient with myelodysplastic syndrome and decreased erythrocyte expression of blood group A antigen.

    abstract:BACKGROUND:Loss of blood group ABO antigens on red blood cells (RBCs) is well known in patients with leukemias, and such decreased ABO expression has been reported to be strongly associated with hypermethylation of the ABO promoter. We investigated the underlying mechanism responsible for A-antigen reduction on RBCs in...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/trf.15628

    authors: Hayakawa A,Sano R,Takahashi Y,Kubo R,Harada M,Omata M,Yokohama A,Handa H,Tsukada J,Takeshita H,Tsuneyama H,Ogasawara K,Kominato Y

    更新日期:2020-01-01 00:00:00

  • Studies on the blood of a Co (a-b-) proposita and her family.

    abstract::The serum of a pregnant woman whose red cells typed as Co(a-b-) contained an alloantibody that, at the time of the infants delivery, was hemolytic in vitro and had a titer of 32,000 by the antiglobulin test. This antibody, which reacted with cells of all Colton-phenotypes except the proposita's own cells, showed very ...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1987.27387235637.x

    authors: Lacey PA,Robinson J,Collins ML,Bailey DG,Evans CC,Moulds JJ,Daniels GL

    更新日期:1987-05-01 00:00:00

  • A comprehensive assessment program to improve blood-administering practices using the FOCUS-PDCA model.

    abstract:BACKGROUND:The Joint Commission on the Accreditation of Healthcare Organizations requires that hospitals have a planned approach to systematically collect data on processes related to the use, ordering, and administering of blood components. This study describes how a comprehensive blood-administering assessment progra...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/j.1537-2995.2004.03117.x

    authors: Saxena S,Ramer L,Shulman IA

    更新日期:2004-09-01 00:00:00

  • A new method for monitoring the sterility of blood donation.

    abstract::Sterility of blood products is a cardinal contributor to patient safety. Bacteriologic controls of stable products comply with strict regulations, but legislation imposes only limited constraints in the case of perishable products, such as packed red cells (RBCs) or fresh-frozen plasma (FFP). Therefore, it is essentia...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1986.26386209392.x

    authors: Guéguen M,Durand F,Delamaire D,Beauplet A,Tardivel R,Genetet B,Chalumeau H,Balme MC

    更新日期:1986-05-01 00:00:00

  • Evaluation of platelet mitochondria integrity after treatment with Mirasol pathogen reduction technology.

    abstract:BACKGROUND:Previous studies showed that Mirasol (Navigant Biotechnologies, Inc.) pathogen reduction technology (PRT) treatment resulted in an increase in platelet (PLT) glucose consumption and lactate production rates and decrease in pH in media during PLT storage. Increased glycolytic flux could result from damage to ...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/j.1537-2995.2005.04381.x

    authors: Li J,Lockerbie O,de Korte D,Rice J,McLean R,Goodrich RP

    更新日期:2005-06-01 00:00:00

  • Coagulopathy after traumatic brain injury: incidence, pathogenesis, and treatment options.

    abstract::Coagulopathy after traumatic brain injury (TBI) is frequent and represents a powerful predictor related to outcome and prognosis. The complex pathophysiological mechanisms of the coagulopathy of TBI are multifactorial and remain still undefined. The nature of the coagulation abnormalities differs between severe TBI an...

    journal_title:Transfusion

    pub_type: 杂志文章,评审

    doi:10.1111/trf.12033

    authors: Maegele M

    更新日期:2013-01-01 00:00:00

  • Incidence of transfusion reactions: a multicenter study utilizing systematic active surveillance and expert adjudication.

    abstract:BACKGROUND:Prevalence estimates of the serious hazards of transfusion vary widely. We hypothesized that the current reporting infrastructure in the United States fails to capture many transfusion reactions and undertook a multicenter study using active surveillance, data review, and adjudication to test this hypothesis...

    journal_title:Transfusion

    pub_type: 杂志文章,多中心研究

    doi:10.1111/trf.13730

    authors: Hendrickson JE,Roubinian NH,Chowdhury D,Brambilla D,Murphy EL,Wu Y,Ness PM,Gehrie EA,Snyder EL,George Hauser R,Gottschall JL,Kleinman S,Kakaiya R,Strauss RG,National Heart, Lung, and Blood Institute (NHLBI) Recipient Epidemio

    更新日期:2016-10-01 00:00:00

  • Expanded evaluation of blood donors in the United States for human immunodeficiency virus type 1 non-B subtypes and antiretroviral drug-resistant strains: 2005 through 2007.

    abstract:BACKGROUND:In a previous study of 66 human immunodeficiency virus (HIV)-infected US blood donors from 1999 to 2005, HIV-1 non-B and antiretroviral drug-resistant strains accounted for 4.7 and 6.5% of HIV infections, respectively. This study was expanded to include an additional 11 recently acquired infections and 197 e...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/j.1537-2995.2010.02767.x

    authors: Brennan CA,Yamaguchi J,Devare SG,Foster GA,Stramer SL

    更新日期:2010-12-01 00:00:00

  • A sensitive quantitative single-platform flow cytometry protocol to measure human platelets in mouse peripheral blood.

    abstract:BACKGROUND:The NOD/SCID mouse is a widely used model for human cord blood (CB) transplantation. Engraftment is generally estimated with semiquantitative methods, measuring the percentage of human cells among mouse cells. To compare protocols aiming to improve hematopoietic recovery, quantitative methods to enumerate hu...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/j.1537-2995.2007.01472.x

    authors: Schipper LF,van Hensbergen Y,Fibbe WE,Brand A

    更新日期:2007-12-01 00:00:00

  • Estimating the incubation time distribution and expected number of cases of transfusion-associated acquired immune deficiency syndrome.

    abstract::The number of cases of transfusion-associated acquired immune deficiency syndrome (TA-AIDS) that will be seen over the next few years is difficult to estimate, because of the uncertainty about the number of persons infected with the human immunodeficiency virus (HIV) via blood transfusion and about the duration of the...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1989.29890020437.x

    authors: Kalbfleisch JD,Lawless JF

    更新日期:1989-10-01 00:00:00

  • Continuous-flow leukapheresis for rapid cytoreduction in leukemia.

    abstract::Three patients with leukemia were treated for acute leukostasis using the continuous-flow cell separator. The first patient, treated with a standard procedure sustained only a 14 per cent decrease in leukocyte count even though 50 X 10(10) leukocytes were removed. A more aggressive approach was taken with the second t...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1980.20480260280.x

    authors: Lane TA

    更新日期:1980-07-01 00:00:00

  • Degenerate polymerase chain reaction strategy with DNA microarray for detection of multiple and various subtypes of virus during blood screening.

    abstract:BACKGROUND:The risk of transferring blood-borne infections during transfusion is continually increasing because of newly emerging and reemerging viruses. Development of a rapid screening method for emerging viruses that might be transmitted by transfusion is required to eliminate such pathogens during blood donor scree...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/trf.12193

    authors: Takizawa K,Nakashima T,Mizukami T,Kuramitsu M,Endoh D,Kawauchi S,Sasaki K,Momose H,Kiba Y,Mizutani T,Furuta RA,Yamaguchi K,Hamaguchi I

    更新日期:2013-10-01 00:00:00

  • Differences in quality between privately and publicly banked umbilical cord blood units: a pilot study of autologous cord blood infusion in children with acquired neurologic disorders.

    abstract:BACKGROUND:A pilot study was conducted to determine the safety and feasibility of intravenous administration of autologous umbilical cord blood (CB) in young children with acquired neurologic disorders. Most CB units (CBUs) were electively stored in private CB banks. Unlike public banks, which utilize specific criteria...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/j.1537-2995.2010.02720.x

    authors: Sun J,Allison J,McLaughlin C,Sledge L,Waters-Pick B,Wease S,Kurtzberg J

    更新日期:2010-09-01 00:00:00

  • Performance profile of an updated safety measure rapid assay for bacteria in platelets.

    abstract:BACKGROUND:The Verax PGD rapid test for bacteria in platelets (PLTs) has been updated to simplify workflow and improve specificity and sensitivity by employing a novel sequential format. The performance of this updated version, called PGDprime, was evaluated to determine its suitability for use as an FDA-cleared "safet...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/trf.16000

    authors: Vallejo RP,Shinefeld L,LaVerda D,Best N,Lawrence G,Lousararian A,Hornbaker N,Rasmusson P,Mintz PD

    更新日期:2020-11-01 00:00:00

  • Multicenter performance evaluation of a transcription-mediated amplification assay for screening of human immunodeficiency virus-1 RNA, hepatitis C virus RNA, and hepatitis B virus DNA in blood donations.

    abstract:BACKGROUND:The performance of the recently launched Procleix Ultrio (Chiron/Gen-Probe) human immunodeficiency virus-1 (HIV-1), hepatitis C virus (HCV), and hepatitis B virus (HBV) blood screening assay was evaluated in a European multicenter study. STUDY DESIGN AND METHODS:Serial dilutions of reference materials were ...

    journal_title:Transfusion

    pub_type: 杂志文章,多中心研究

    doi:10.1111/j.1537-2995.2005.00197.x

    authors: Koppelman MH,Assal A,Chudy M,Torres P,de Villaescusa RG,Reesink HW,Lelie PN,Cuypers HT

    更新日期:2005-08-01 00:00:00

  • Hemolytic transfusion reaction due to anti-IH.

    abstract:BACKGROUND:Anti-IH is usually a clinically insignificant antibody that may complicate a serologic workup. However, it can occasionally cause hemolysis. We report a rare case of acute hemolysis caused by anti-IH. CASE REPORT:A 60-year-old man with a long history of chronic myelomonocytic leukemia and anemia, blood grou...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/j.1537-2995.2011.03209.x

    authors: Irani MS,Richards C

    更新日期:2011-12-01 00:00:00

  • Unusual kinetics of white cell clearance in transfused mice.

    abstract:BACKGROUND:Donor white cells (WBCs) in blood transfusions are responsible for complications in recipients, including alloimmunization, graft-versus-host disease (GVHD), and virus transmission and reactivation. The recent use of sequence-specific polymerase chain reaction assays to monitor the kinetics of clearance of d...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1995.35295125737.x

    authors: Goodarzi MO,Lee TH,Pallavicini MG,Donegan EA,Busch MP

    更新日期:1995-02-01 00:00:00

  • Prevention of transfusion-associated Chagas' disease: efficacy of white cell-reduction filters in removing Trypanosoma cruzi from infected blood.

    abstract:BACKGROUND:Transfusion-associated Chagas' disease (TA-CD) is a worldwide problem. Measures adopted to prevent TA-CD include the clinical and serologic screening of blood donors and/or the inactivation of Trypanosoma cruzi present in collected blood, using gentian violet as the trypanocidal agent. This study investigate...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1995.35996029154.x

    authors: Moraes-Souza H,Bordin JO,Bardossy L,MacPherson DW,Blajchman MA

    更新日期:1995-09-01 00:00:00

  • Management of chronic myelocytic leukemia in pregnancy by cell pheresis.

    abstract::Cell pheresis was employed in the initial management of a pregnant patient with chronic myelocytic leukemia (CML). Reduction in circulating leukocyte and platelet counts was evident after two weeks of therapy. This technique is an effective mode of management of the pregnant patient with CML and may play an important ...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1978.18178118555.x

    authors: Caplan SN,Coco FV,Berkman EM

    更新日期:1978-01-01 00:00:00

  • Novel multiple swab method enables high efficiency in SARS-CoV-2 screenings without loss of sensitivity for screening of a complete population.

    abstract:BACKGROUND:In the pandemic, testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) by real-time polymerase chain reaction is one of the pillars on which countermeasures are based. Factors limiting the output of laboratories interfere with the effectiveness of public health measures. Conserving reagent...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/trf.15973

    authors: Schmidt M,Hoehl S,Berger A,Zeichhardt H,Hourfar K,Ciesek S,Seifried E

    更新日期:2020-07-06 00:00:00

  • Red blood cells stored for increasing periods produce progressive impairments in nitric oxide-mediated vasodilation.

    abstract:BACKGROUND:Clinical outcomes in transfused patients may be affected by the duration of blood storage, possibly due to red blood cell (RBC)-mediated disruption of nitric oxide (NO) signaling, a key regulator of vascular tone and blood flow. STUDY DESIGN AND METHODS:AS-1 RBC units stored up to 42 days were sampled at se...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/trf.12111

    authors: Alexander JT,El-Ali AM,Newman JL,Karatela S,Predmore BL,Lefer DJ,Sutliff RL,Roback JD

    更新日期:2013-11-01 00:00:00

  • Potassium load in CPD-preserved whole blood and two types of packed red blood cells.

    abstract::The potassium load of transfused blood must be minimized. We have compared the total plasma potassium content of units of CPD-preserved stored whole blood (SWB), stored packed cells (SPC), and packed cells prepared from stored whole blood (WB-PC). Plasma potassium concentrations, unit weights, and hematocrits of 20 un...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1975.15275122809.x

    authors: Michael JM,Dorner I,Bruns D,Ladenson JH,Sherman LA

    更新日期:1975-03-01 00:00:00

  • How we handled the dextran shortage: an alternative washing or dilution solution for cord blood infusions.

    abstract::Dextran 40 is the main component of the solution used to wash or dilute thawed cord blood unit (CBU) products for stem cell transplant. Dextran 40 became unavailable in the United States as of April 2014. Like many other cellular therapy laboratories in the United States, we found ourselves with limited dextran 40 inv...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/trf.13015

    authors: Reich-Slotky R,Bachegowda LS,Ancharski M,Mendeleyeva L,Rubinstein P,Rennert H,Shore T,van Besien K,Cushing M

    更新日期:2015-06-01 00:00:00

  • Prevalence of serologic markers for hepatitis B and C viruses in Brazilian blood donors and incidence and residual risk of transfusion transmission of hepatitis C virus.

    abstract:BACKGROUND:We evaluate the current prevalence of serologic markers for hepatitis B virus (HBV) and hepatitis C virus (HCV) in blood donors and estimated HCV incidence and residual transfusion-transmitted risk at three large Brazilian blood centers. STUDY DESIGN AND METHODS:Data on whole blood and platelet donations we...

    journal_title:Transfusion

    pub_type: 杂志文章,多中心研究

    doi:10.1111/j.1537-2995.2012.03840.x

    authors: de Almeida-Neto C,Sabino EC,Liu J,Blatyta PF,Mendrone-Junior A,Salles NA,Leão SC,Wright DJ,Basques FV,Ferreira JE,Busch MP,Murphy EL,NHLBI Retrovirus Epidemiology Donor Study-II (REDS-II), International Component.

    更新日期:2013-04-01 00:00:00

  • Further evaluation of a new standard of efficacy for stored platelets.

    abstract:BACKGROUND:The proposal to assess the viability capabilities of platelets (PLTs) collected, treated, or stored in a developmental system against "fresh" PLTs from the same subject poses several important methodologic issues pertaining to the timing and manner of the collecting and separating the fresh PLTs. This study ...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/j.1537-2995.2005.00177.x

    authors: AuBuchon JP,Herschel L,Roger J

    更新日期:2005-07-01 00:00:00

  • Pathogen safety of a pasteurized four-factor human prothrombin complex concentrate preparation using serial 20N virus filtration.

    abstract:BACKGROUND:Beriplex P/N/Kcentra/Coaplex/Confidex is a four-factor human prothrombin complex concentrate (PCC). Here, we describe the pathogen safety profile and biochemical characteristics of an improved manufacturing process that further enhances the virus safety of Beriplex P/N. STUDY DESIGN AND METHODS:Samples of p...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/trf.14010

    authors: Nowak T,Popp B,Gröner A,Schäfer W,Kalina U,Enssle K,Roth NJ

    更新日期:2017-05-01 00:00:00

  • Transfusion-related adverse reactions reported to the National Healthcare Safety Network Hemovigilance Module, United States, 2010 to 2012.

    abstract:BACKGROUND:In 2010, health care facilities in the United States began voluntary enrollment in the National Healthcare Safety Network (NHSN) Hemovigilance Module. Participants report transfusion practices; red blood cell, platelet (PLT), plasma, and cryoprecipitate units transfused; and transfusion-related adverse react...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/trf.12918

    authors: Harvey AR,Basavaraju SV,Chung KW,Kuehnert MJ

    更新日期:2015-04-01 00:00:00

  • Residual plasma in red blood cells and transfusion-related acute lung injury.

    abstract:BACKGROUND:Transfusion-related acute lung injury (TRALI) is the most common cause of death from blood transfusion and red blood cells (RBCs) now account for approximately 50% of these fatalities. RBCs from female donors have been implicated in large series and HLA Class II antibodies to cognate recipient antigens ident...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/trf.12662

    authors: Weber LL,Roberts LD,Sweeney JD

    更新日期:2014-10-01 00:00:00

  • The association of blood transfusion with mortality after cardiac surgery: cause or confounding? (CME).

    abstract:BACKGROUND:Bleeding into the chest is a life-threatening complication of cardiac surgery. Blood transfusion has been implicated as an important cause of harm associated with bleeding, based largely on studies demonstrating an independent association between transfusion and mortality. These studies did not, however, con...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/j.1537-2995.2012.03697.x

    authors: Dixon B,Santamaria JD,Reid D,Collins M,Rechnitzer T,Newcomb AE,Nixon I,Yii M,Rosalion A,Campbell DJ

    更新日期:2013-01-01 00:00:00