Abstract:
PURPOSE:To evaluate and compare the predictability and safety of immediate small-incision lenticule extraction, also known as SMILE, after suction loss during the procedure with those of uneventful small-incision lenticule extraction. SETTING:Nunemiso Eye Center, Seoul, South Korea. DESIGN:Retrospective case series. METHODS:Patients who had immediate small-incision lenticule extraction using reapplied suction (study group) or uneventful small-incision lenticule extraction (control group) for myopia or myopic astigmatism were included. All patients were followed for at least 12 months. Demographic as well as visual and refractive outcomes were compared between the 2 groups. RESULTS:Twenty-three eyes were enrolled in the study group and 48 eyes in the control group. The overall cumulative incidence of suction loss was 0.2% (28 of 11 762 eyes). Twenty-two eyes (96%) in the study group had unchanged or improved decimal Snellen corrected distance visual acuity (CDVA). At 12 months, the mean uncorrected distance visual acuity, CDVA, and manifest refraction defocus equivalent in the study group and control group were 0.99 ± 0.17 (SD), 1.11 ± 0.14, 0.75 ± 0.50 diopters (D), and 1.25 ± 0.22 D, 1.26 ± 0.21 D, 0.35 ± 0.26 D, respectively (P = .000, P = .007, and P = .000, respectively). The correlation between the achieved and the attempted spherical equivalent refraction was slightly better in the control group (R2 = 0.972) than in the study group (R2 = 0.933). CONCLUSIONS:Immediate small-incision lenticule extraction using reapplied suction resulted in safe and clinically predictable long-term outcomes. However, predictability was lower for immediate than for uneventful small-incision lenticule extraction.
journal_name
J Cataract Refract Surgjournal_title
Journal of cataract and refractive surgeryauthors
Park JH,Koo HJdoi
10.1016/j.jcrs.2016.12.034subject
Has Abstractpub_date
2017-04-01 00:00:00pages
466-472issue
4eissn
0886-3350issn
1873-4502pii
S0886-3350(17)30122-0journal_volume
43pub_type
杂志文章abstract:PURPOSE:To determine whether frozen cultured sheets of human allogeneic epidermal keratinocytes (CEAK) improved wound repair after experimental corneal ablation by photorefractive keratectomy (PRK). SETTING:Hospital "Luis Sanchez Bulnes" de la Asociación para Evitar la Ceguera en Mexico, I.A.P, and Department of Cell ...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(01)01349-9
更新日期:2002-09-01 00:00:00
abstract:PURPOSE:To analyze risk factors and management of pupillary intraocular lens (IOL) capture after IOL transscleral fixation. SETTING:Department of Ophthalmology, Seoul National University Hospital, Seoul, South Korea. DESIGN:Retrospective case series. METHODS:A chart review was performed of patients who had transscle...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2017.08.021
更新日期:2017-12-01 00:00:00
abstract::A 21-year-old woman had crosslinking for keratoconus in the right eye; the left eye was scheduled for penetrating keratoplasty. Five days postoperatively, she presented with geographic epithelial keratitis and iritis. Analysis of tear samples by polymerase chain reaction confirmed the diagnosis. The patient was treate...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2007.06.036
更新日期:2007-11-01 00:00:00
abstract:PURPOSE:To assess the ability of corneal power measurements by a rotating Scheimpflug camera to measure the refractive change induced by myopic excimer laser surgery. SETTING:G.B. Bietti Foundation-IRCCS, Rome, Italy. DESIGN:Evaluation of diagnostic test. METHODS:The following corneal power measurements by the Penta...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2012.12.031
更新日期:2013-04-01 00:00:00
abstract:PURPOSE:To assess the rotation and centration stability of the new design features of a 1-piece aspheric hydrophobic acrylic intraocular lens (IOL). SETTING:National Eye Hospital, Cairo, Egypt. DESIGN:Randomized clinical trial. METHODS:Patients in this study had implantation of a 1-piece Tecnis 1 ZCB00 IOL or a 3-pi...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章,随机对照试验
doi:10.1016/j.jcrs.2012.09.020
更新日期:2013-03-01 00:00:00
abstract:PURPOSE:To determine the sex hormone levels in the serum and aqueous humor in patients with age-related cataract and the corresponding hormone receptors in cataract lens epithelial cells (LECs). SETTING:Research Laboratory, International Intraocular Implant Training Center, Tianjin Medical University, Tianjin, China. ...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(02)01436-0
更新日期:2003-01-01 00:00:00
abstract::Primary posterior laser capsulotomy (PPLC) requires adequate visualization and spacing of the posterior lens capsule (PLC) and anterior hyaloid membrane (AHM). After intraocular lens implantation and watertight incision hydration, the laser is redocked for optical coherence tomography reimaging. If the PLC and AHM are...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2019.03.008
更新日期:2019-07-01 00:00:00
abstract:PURPOSE:To report results of the National French Observational Database for Endophthalmitis (Observatoire National Des Endophtalmies [ONDE]). SETTING:Departments of ophthalmology at universities, general hospitals, and private clinics. METHODS:In this multicenter national interventional case series, data were collect...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章,多中心研究
doi:10.1016/j.jcrs.2008.10.018
更新日期:2009-01-01 00:00:00
abstract::There are optical and mechanical advantages of the biconvex posterior chamber intraocular lens (IOL) following cataract surgery. A clinical study of Nd:YAG laser capsulotomy in eyes with biconvex IOLs was undertaken. The lenses were made of injection-molded poly(methyl methacrylate) without laser spacing. Using specif...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(89)80065-3
更新日期:1989-07-01 00:00:00
abstract:PURPOSE:To demonstrate the use of polar value analysis of surgically induced astigmatism (SIA). SETTING:Department of Ophthalmology, Arhus University Hospital, Arhus, Denmark. METHODS:Univariate polar value analysis of SIA was demonstrated for a single patient and for aggregate data. Bivariate polar value analysis wa...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(00)00799-9
更新日期:2001-01-01 00:00:00
abstract:PURPOSE:To study the results of simultaneous photorefractive keratectomy (PRK) and corneal collagen crosslinking (CXL) in keratoconus after previous intrastromal corneal ring segment (ICRS) implantation. SETTING:Enaim Laser Center, Jerusalem, Israel. DESIGN:Case series. METHODS:This study comprised patients with mod...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2012.05.033
更新日期:2012-10-01 00:00:00
abstract::Anterior chamber intraocular lenses were implanted in 50 phakic primate eyes and followed by serial histopathology for two years. Significant observations included corneal endothelial alterations, haptic erosion into and encapsulation by peripheral iris and ciliary body, and chronic low grade inflammation. ...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(13)80832-2
更新日期:1991-05-01 00:00:00
abstract:PURPOSE:To determine the in vitro bacterial adherence to intraocular lenses (IOLs) routinely used at 1 center. SETTING:University Hospital of Vienna, Vienna, Austria. METHODS:Four types of rigid IOLs (hydrophobic poly[methyl methacrylate] [PMMA] and hydrophilic heparin-surface-modified PMMA) and 5 types of foldable i...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(02)01741-8
更新日期:2003-02-01 00:00:00
abstract::A patient with myopia and astigmatism in the ideal range for correction by radial keratotomy had surgery on both eyes. Postoperatively, she developed bilateral high hyperopia, with a +9.00 diopter refractive error (OD) and a spherical equivalent of +8.75 diopters (OS). Her best corrected visual acuity dropped one line...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(13)80289-1
更新日期:1993-01-01 00:00:00
abstract:PURPOSE:To estimate the actual and theoretical risks for visual loss associated with use of the implantable contact lens (ICL). SETTING:Multicenter clinical trial data. METHODS:An established model for estimating the risk for visual loss associated with retinal detachment (RD) following clear lens extraction (CLE) wa...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章,评审
doi:10.1016/s0886-3350(02)02040-0
更新日期:2003-07-01 00:00:00
abstract::We report the results of a prospective study that evaluated the efficacy, predictability, and safety of excimer laser photorefractive keratectomy (PRK) to correct residual myopia after radial keratotomy (RK). Using a 193 nm excimer laser, we performed PRK on ten undercorrected myopic eyes that had previous RK surgery....
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(13)80224-6
更新日期:1994-09-01 00:00:00
abstract::We present the results of a survey carried out by independent researchers to determine the subjective success rate of a series of excimer laser photorefractive keratectomy procedures to correct myopia. Thirty patients, selected at random from a group of 300, had received treatment to both eyes with a minimum of six mo...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(13)80766-3
更新日期:1994-03-01 00:00:00
abstract::Cortex removal, especially at the 12 o'clock position, is more difficult with small incision phacoemulsification than with planned extracapsular cataract extraction. In this study an irrigation/aspiration handpiece with changeable tips was used for cortex removal in a large, unselected, consecutive series of small inc...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(13)80911-x
更新日期:1992-05-01 00:00:00
abstract:PURPOSE:To study the effect of glistenings on the optical quality of a hydrophobic acrylic intraocular lens (IOL). SETTING:David J. Apple Laboratory, Heidelberg, Germany. DESIGN:An in vitro laboratory study. METHODS:An accelerated aging protocol was used to induce glistenings (microvacuoles) in 38 hydrophobic acryli...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2019.01.025
更新日期:2019-07-01 00:00:00
abstract::The first 45 cases of extracapsular cataract extraction, with posterior chamber intraocular lens implantation performed by ophthalmology residents at an urban county hospital were evaluated. These cases, which were performed from March 1983 to June 1984, involved a patient population that was primarily black and Hispa...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(86)80054-2
更新日期:1986-01-01 00:00:00
abstract:PURPOSE:To compare loteprednol etabonate (LE) gel 0.5% with prednisolone acetate suspension (PA) 1% for the treatment of inflammation after cataract surgery in children. SETTING:Eleven sites in the United States. DESIGN:Randomized, double-masked, parallel-group, noninferiority study. METHODS:Eligible patients were a...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1097/j.jcrs.0000000000000218
更新日期:2020-08-01 00:00:00
abstract:PURPOSE:To develop and test the validity of a surgical competency assessment tool for simulated small-incision cataract surgery (SICS). SETTING:Participating ophthalmologists contributed from 8 countries. DESIGN:Qualitative and quantitative development and evaluation of face and content validity of an assessment rubr...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章,多中心研究
doi:10.1016/j.jcrs.2019.04.010
更新日期:2019-09-01 00:00:00
abstract:PURPOSE:Comparison of lens capsule-related complications resulting from femtosecond laser-assisted capsulotomy and manual capsulorhexis in patients with white cataracts. SETTING:Eye Center, Second Affiliated Hospital, Zhejiang Medical School, Hangzhou, China. DESIGN:Prospective consecutive nonrandomized comparative c...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2018.10.037
更新日期:2019-03-01 00:00:00
abstract::This continuous curvilinear capsulorhexis (CCC) technique is for use in complicated surgical cases such as when the anterior chamber is shallow, the red reflex is not good, or eye movements are present. This technique is easier and safer in such cases because it uses a cystotome connected to a viscoelastic syringe. Fi...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(98)80162-4
更新日期:1998-11-01 00:00:00
abstract:PURPOSE:To evaluate the diagnostic capacity of the keratoconus match index (KMI) and keratoconus match probability (KMP) classification from a dynamic bidirectional applanation device (Ocular Response Analyzer) in eyes with pellucid marginal degeneration (PMD). SETTING:Department of Ophthalmology, University Clinics S...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2014.03.018
更新日期:2014-06-01 00:00:00
abstract::Recent clinical studies indicate that flurbiprofen, a cyclooxygenase inhibitor, prevents miosis and breakdown of the blood-aqueous barrier during cataract surgery. Yet based on clinical and experimental data, some researchers do not agree that flurbiprofen prevents miosis. We conducted a double-blind clinical study of...
journal_title:Journal of cataract and refractive surgery
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1016/s0886-3350(13)80013-2
更新日期:1993-09-01 00:00:00
abstract::A 73-year-old woman with bilateral previous radial keratotomies (RK) and symptomatic cataracts was referred. The uncorrected distance visual acuity (UDVA) was 0.24 logarithm of the minimum angle of resolution (logMAR) in the left eye and 0.32 logMAR in the left eye. The American Society of Cataract and Refractive Surg...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2018.06.005
更新日期:2018-08-01 00:00:00
abstract::Postoperative lens capsule opacification is a complication of extracapsular cataract extraction. To avoid this problem, we aspirated the epithelial cells lining the internal surface of the capsular bag. Anterior capsule specimens collected three and six years after the first surgical intervention (extracapsular catara...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(13)80302-1
更新日期:1993-05-01 00:00:00
abstract:PURPOSE:To determine whether preoperative assessment of posterior capsule integrity using anterior segment optical coherence tomography (AS-OCT) can predict posterior capsule dehiscence in patients with posterior polar cataract having phacoemulsification. SETTING:Aravind Eye Hospital and Postgraduate Institute of Opht...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2018.07.056
更新日期:2018-12-01 00:00:00
abstract::A monolayer of proliferating lens epithelium on the anterior surface of an intraocular lens was found cytologically and confirmed histologically in a postmortem examination of one eye of a 57-year-old man. The man had had extracapsular cataract surgery five years earlier. This pathological finding confirms observation...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(13)80353-7
更新日期:1993-11-01 00:00:00