Relationship between morphological features and kinetic patterns of enhancement of the dynamic breast magnetic resonance imaging and tumor expression of metalloproteases and their inhibitors in invasive breast cancer.

Abstract:

AIM:Matrix metalloproteases (MMPs) expression and their inhibitors (TIMPs) play an important role in tumor physiopathology, so we investigated the relationship between the magnetic resonance (MR) and MMPs/TIMPs expression by breast carcinomas. MATERIALS AND METHODS:MRI parameters of 64 breast carcinomas were investigated. An immunohistochemical study was also performed in these cases using tissue microarrays and specific antibodies against MMP-1, MMP-2, MMP-7, MMP-9, MMP-11, MMP-13, MMP-14, TIMP-1, TIMP-2 and TIMP-3. RESULTS:Tumors with spiculated margins had a high global (score) values of MMP-1 or MMP-7, and high expression of TIMP-3 by tumor cells. Heterogeneous tumors had a higher score values of MMP-1, MMP-13, TIMP-2 or TIMP-3, and frequent expression of TIMP-3 by tumor cells. Tumors showing fast enhancement, had higher score values of MMP-1 or MMP-11. Associations between washout curve (type III) and MMP-1, MMP-11, MMP-13 and TIMP-1 expression by tumor cells, were found. CONCLUSIONS:MRI features may predict in some grade the expressions of MMPs/TIMPs in breast tumors, which might to contribute to a better biological characterization of breast cancer.

journal_name

Magn Reson Imaging

authors

Cuadriello EF,Fernández-Guinea Ó,Eiró N,González LO,Junquera S,Vizoso FJ

doi

10.1016/j.mri.2016.04.005

subject

Has Abstract

pub_date

2016-10-01 00:00:00

pages

1107-13

issue

8

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(16)30017-0

journal_volume

34

pub_type

杂志文章
  • Dose distribution of proton beams with NMR measurements of Fricke-agarose gels.

    abstract::Fricke-agarose gels have been irradiated with a proton beam. Then samples have been extracted at different depths with respect to the beam penetration distance, corresponding to different irradiation doses. Relaxation times T1 and T2, measured at 17 MHz, appear sensitive to this kind of radiation. In particular, T2 ex...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00380-3

    authors: Di Capua S,D'Errico F,Egger E,Guidoni L,Luciani AM,Rosi A,Viti V

    更新日期:1997-01-01 00:00:00

  • Application of magnetic resonance imaging to the measurement of neurodegeneration in rat brain: MRI data correlate strongly with histology and enzymatic analysis.

    abstract::Focal brain ischemia was induced by middle cerebral artery occlusion in the rat. The volume of cerebral damage was determined 2 days later by MRI in vivo and in the same animals histologically. The edema volume as measured by MRI and the histologically determined infarction was highly correlated. As a consequence, the...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90411-r

    authors: Allegrini PR,Sauer D

    更新日期:1992-01-01 00:00:00

  • MR imaging of pterygoid muscle inflammation.

    abstract::A case report of trismus after a dental procedure is evaluated by MR imaging. The medial and lateral pterygoid muscles showed inflammatory changes. Etiologies of trismus are reviewed. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(90)90148-u

    authors: Ciacchella AP,Higgins WL

    更新日期:1990-01-01 00:00:00

  • Evaluation of intracranial stenoses and aneurysms with accelerated 4D flow.

    abstract::The aim of this study was to evaluate intracranial arterial stenoses and aneurysms with accelerated time-resolved three-dimensional (3D) phase-contrast MRI or 4D flow. The 4D flow technique was utilized to image four normal volunteers, two patients with intracranial stenoses and two patients with intracranial aneurysm...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.05.042

    authors: Hope TA,Hope MD,Purcell DD,von Morze C,Vigneron DB,Alley MT,Dillon WP

    更新日期:2010-01-01 00:00:00

  • A simulation-based comparison of two methods for determining relaxation rates from relaxometry images.

    abstract::When assessing liver iron content using relaxometry, an average relaxation rate (R1, R2 or R2*) is usually determined from a region of interest or the entire liver. This is commonly performed by fitting the signal decay in individual voxels to an appropriate relaxation function. The voxel-level parameters resulting fr...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.11.005

    authors: Marro K,Otto R,Kolokythas O,Shimamura A,Sanders JE,McDonald GB,Friedman SD

    更新日期:2011-05-01 00:00:00

  • Theoretical considerations in measurement of time discrepancies between input and myocardial time-signal intensity curves in estimates of regional myocardial perfusion with first-pass contrast-enhanced MRI.

    abstract::The purpose of this study was to develop a method to determine time discrepancies between input and myocardial time-signal intensity (TSI) curves for accurate estimation of myocardial perfusion with first-pass contrast-enhanced MRI. Estimation of myocardial perfusion with contrast-enhanced MRI using kinetic models req...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.06.015

    authors: Natsume T,Ishida M,Kitagawa K,Nagata M,Sakuma H,Ichihara T

    更新日期:2015-11-01 00:00:00

  • MR angiography of meningioma.

    abstract::The clinical evaluation of three-dimensional time-of-flight MR angiography was prospectively performed in 16 patients with intracranial meningioma. MR angiographic techniques used in this study both with and without gadopentetate dimeglumine made it possible to demonstrate the topographic relationship between the tumo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90466-q

    authors: Kadota T,Kuriyama K,Inoue E,Fujita M,Nakagawa H,Kuroda C

    更新日期:1993-01-01 00:00:00

  • A rapid method for the measurement and estimation of CO2 diffusivity in liquid hydrocarbon-saturated porous media using MRI.

    abstract::In this study, magnetic resonance imaging (MRI) was used to dynamically visualize the diffusion process of CO2 in porous media saturated with liquid hydrocarbon. Based on the assumption of semi-infinite media, effective CO2 diffusivity was obtained directly by the nonlinear fitting of one MR profile during the diffusi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.12.024

    authors: Zhao Y,Chen J,Yang M,Liu Y,Song Y

    更新日期:2016-05-01 00:00:00

  • Automated segmentation of lateral ventricles from human and primate magnetic resonance images using cognition network technology.

    abstract::Automatic segmentation of different types of tissue from magnetic resonance images is of great importance for clinical and research applications, particularly large-scale and longitudinal studies of brain pathology. We developed a fully automated algorithm for the segmentation of lateral ventricles from cranial magnet...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.08.013

    authors: Schönmeyer R,Prvulovic D,Rotarska-Jagiela A,Haenschel C,Linden DE

    更新日期:2006-12-01 00:00:00

  • Computer-assisted design of surface coils used in magnetic resonance imaging. I. The calculation of the magnetic field.

    abstract::For a number of reasons, it is desirable to fabricate coils which, for a known current, shall produce predetermined values of the magnetic field intensity at a number of points within a nuclear magnetic resonance imager. The calculation of the magnetic field intensity at a set of points involves the integration of the...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90524-9

    authors: Letcher JH

    更新日期:1989-11-01 00:00:00

  • A data augmentation approach to train fully convolutional networks for left ventricle segmentation.

    abstract::Left ventricle (LV) segmentation plays an important role in the diagnosis of cardiovascular diseases. The cardiac contractile function can be quantified by measuring the segmentation results of LVs. Fully convolutional networks (FCNs) have been proven to be able to segment images. However, a large number of annotated ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.08.004

    authors: Lin A,Wu J,Yang X

    更新日期:2020-02-01 00:00:00

  • Severe anaphylactoid reaction after i.v. Gd-DTPA.

    abstract::Serious adverse reactions following the IV administration of Gd-DTPA (Magnevist, gadopenetate dimeglumine, Berlex Laboratories, Wayne, NJ), although extremely rare, can occur. As yet, there has been no published case of a severe anaphylactoid-type reaction to Gd-DTPA. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(90)90019-x

    authors: Weiss KL

    更新日期:1990-01-01 00:00:00

  • Quantitative MRI using T1ρ and T2 in human osteoarthritic cartilage specimens: correlation with biochemical measurements and histology.

    abstract:PURPOSE:A direct correlation between T(1ρ), T(2) and quantified proteoglycan and collagen contents in human osteoarthritic cartilage has yet to be documented. We aimed to investigate the orientation effect on T(1ρ) and T(2) values in human osteoarthritic cartilage and to quantify the correlation between T(1ρ), T(2) vs....

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.09.004

    authors: Li X,Cheng J,Lin K,Saadat E,Bolbos RI,Jobke B,Ries MD,Horvai A,Link TM,Majumdar S

    更新日期:2011-04-01 00:00:00

  • Fast Field Echo imaging: an overview and contrast calculations.

    abstract::Current fast imaging techniques are based on gradient echo sequences with reduced flip angle excitation pulses and very short repetition times TR. Practical T2 values may be of the order of TR or longer. In this situation, a different image contrast can be obtained, depending on details of the sequence. Four essential...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/0730-725x(88)90472-9

    authors: van der Meulen P,Groen JP,Tinus AM,Bruntink G

    更新日期:1988-07-01 00:00:00

  • Assessment of myocardial perfusion using multisection first-pass MRI and color-coded parameter maps: a comparison to 99mTc Sesta MIBI SPECT and systolic myocardial wall thickening analysis.

    abstract::The most recently reported magnetic resonance first-pass myocardial perfusion studies were restricted to single slice imaging or a data analysis based on interactively placed regions of interest. This study was designed to investigate a new saturation recovery TurboFLASH sequence for multisection myocardial perfusion ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00166-0

    authors: Penzkofer H,Wintersperger BJ,Knez A,Weber J,Reiser M

    更新日期:1999-02-01 00:00:00

  • The Langerhans' cell histiocytosis (eosinophilic granuloma) of the cervical spine: a rare diagnosis of cervical pain.

    abstract::We present the case of a 44-year-old man who complained of cervical pain. He was treated with physiotherapy and analgetics. Because of persistent pain, computed tomography (CT) scan and MRI were performed. They revealed an osteolytic destruction of the fourth cervical vertebra. The patient was treated surgically for r...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2004.01.006

    authors: Simanski C,Bouillon B,Brockmann M,Tiling T

    更新日期:2004-05-01 00:00:00

  • Test-retest reliability of cerebral blood flow in healthy individuals using arterial spin labeling: Findings from the EMBARC study.

    abstract:INTRODUCTION:Previous investigations of test-retest reliability of cerebral blood flow (CBF) at rest measured with pseudo-continuous Arterial Spin Labeling (pCASL) demonstrated good reliability, but are limited by the use of similar scanner platforms. In the present study we examined test-retest reliability of CBF in r...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.09.004

    authors: Almeida JRC,Greenberg T,Lu H,Chase HW,Fournier JC,Cooper CM,Deckersbach T,Adams P,Carmody T,Fava M,Kurian B,McGrath PJ,McInnis MG,Oquendo MA,Parsey R,Weissman M,Trivedi M,Phillips ML

    更新日期:2018-01-01 00:00:00

  • Assessment of iron oxide particles (AMI 227) and a gadolinium complex (Gd-DOTA) in dynamic susceptibility contrast MR imagings (FLASH and EPI) in a tumor model implanted in rats.

    abstract::The objective of our study was to assess the feasibility of dynamic susceptibility contrast MR technique after bolus injection of SPIO and Gd-DOTA in a tumor model implanted in rats. Tumors were subcutaneously implanted in 24 rats. A FLASH sequence and EPI were evaluated. Different doses of AMI 227 and Gd-DOTA were as...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00197-0

    authors: Loubeyre P,De Jaegere T,Miao Y,Landuyt W,Marchal G

    更新日期:1999-05-01 00:00:00

  • Multicontrast multiecho FLASH MRI for targeting the subthalamic nucleus.

    abstract::The subthalamic nucleus (STN) is one of the most common stimulation targets for treating Parkinson's disease using deep brain stimulation (DBS). This procedure requires precise placement of the stimulating electrode. Common practice of DBS implantation utilizes microelectrode recording to locate the sites with the cor...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.02.006

    authors: Xiao Y,Beriault S,Pike GB,Collins DL

    更新日期:2012-06-01 00:00:00

  • Effect of off-frequency sampling in magnetic resonance elastography.

    abstract::In magnetic resonance elastography (MRE), shear waves at a certain frequency are encoded through bipolar gradients that switch polarity at a controlled encoding frequency and are offset in time to capture wave propagation using a controlled sampling frequency. In brain MRE, there is a possibility that the mechanical a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.09.017

    authors: Johnson CL,Chen DD,Olivero WC,Sutton BP,Georgiadis JG

    更新日期:2012-02-01 00:00:00

  • Simultaneous acquisition of multiple orders of intermolecular multiple-quantum coherence images in vivo.

    abstract::Until recently, NMR imaging with intermolecular multiple-quantum coherences (iMQCs) has been based on the acquisition of a single echo. In vivo studies of iMQC image contrast would greatly benefit from a method that could acquire several orders of quantum coherence during the same acquisition. This would enable compar...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.10.019

    authors: Shannon KL,Branca RT,Galiana G,Cenzano S,Bouchard LS,Soboyejo W,Warren WS

    更新日期:2004-12-01 00:00:00

  • Increased confidence of diagnosis of Ewing sarcoma using T2-weighted MR images.

    abstract::To assess whether magnetic resonance imaging could assist in diagnosing Ewing sarcoma, we retrospectively analyzed T1- and T2-weighted images of 24 consecutive solitary lytic bone lesions, including 18 cases of histologically proven Ewing sarcoma, and six aggressive-appearing benign lesions including eosinophilic gran...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)92450-3

    authors: Hanna SL,Fletcher BD,Kaste SC,Fairclough DL,Parham DM

    更新日期:1994-01-01 00:00:00

  • Short TI short TR inversion recovery imaging using reduced flip angles.

    abstract::In this paper the effects of reducing the flip angle of the 90-degree observation pulse in inversion recovery imaging are described and analyzed. When incorporated in an IR sequence with a short inversion time (STIR), reduction to the 90-degree pulse allows a significant shortening of the repetition time without loss ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(91)90418-l

    authors: Bakker CJ,Witkamp TD,Janssen WM

    更新日期:1991-01-01 00:00:00

  • A quantitative study of water proton relaxation in packed beds of porous particles with varying water content.

    abstract::A quantitative analysis of the dependence of water proton relaxation on water content in randomly packed beds of Sephadex is undertaken. A combination of Osmotic and Capillary theory is used to describe the morphological changes occurring in the packed beds as the water content is lowered. At each water content the wa...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)92032-x

    authors: Hills BP,Babonneau F

    更新日期:1994-01-01 00:00:00

  • Biliary cystadenocarcinoma: seven year follow-up and the role of MRI and MRCP.

    abstract::Biliary cystadenomas and their malignant counterparts, biliary cystadenocarcinomas, are rare cystic tumors that arise from hepatobiliary epithelium. Ultrasound (US) and computed tomography (CT) are the initial imaging modalities used for the evaluation of biliary cystic tumors, but are not specific. MRI and MRCP, beca...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00453-2

    authors: Williams DM,Vitellas KM,Sheafor D

    更新日期:2001-11-01 00:00:00

  • Magnetic resonance in the era of molecular imaging of cancer.

    abstract::Magnetic resonance imaging (MRI) has played an important role in the diagnosis and management of cancer since it was first developed, but other modalities also continue to advance and provide complementary information on the status of tumors. In the future, there will be a major continuing role for noninvasive imaging...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2011.02.003

    authors: Gore JC,Manning HC,Quarles CC,Waddell KW,Yankeelov TE

    更新日期:2011-06-01 00:00:00

  • PERFIDI: parametrically enabled relaxation filters with double and multiple inversion.

    abstract::We present a novel approach to the nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) analysis of complex samples with nontrivial distribution of longitudinal relaxation rate R(1). Parametrically enabled relaxation filters with double and multiple inversion (PERFIDI) aim to separate signals arising ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.12.001

    authors: Sykora S,Bortollotti V,Fantazzini P

    更新日期:2007-05-01 00:00:00

  • Spine MR images in patients with pedicle screw fixation: Comparison of conventional and SEMAC-VAT sequences at 1.5 T.

    abstract:BACKGROUND AND PURPOSE:Slice-encoding metal artifact corrections (SEMAC)-view-angle tilting (VAT) sequences have recently been used in clinical protocols to reduce metal artifacts in MR scans of patients with spinal instrumentation. The objective of this study was to compare the SEMAC-VAT sequence with the conventional...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.08.002

    authors: Park C,Lee E,Yeo Y,Kang Y,Lee JW,Ahn JM,Kang HS

    更新日期:2018-12-01 00:00:00

  • MRI-assisted radiation therapy planning of brain tumors--clinical experiences in 17 patients.

    abstract::A new and simple method for precise determination of lateral opposed treatment portals was developed and used in 17 patients. Compared to CT, MRI led to significant changes of portals in 59% (10/17) of cases. Individual shielding blocks could be precisely designed by use of our new method. MRI is the procedure of choi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(91)90007-9

    authors: Just M,Rösler HP,Higer HP,Kutzner J,Thelen M

    更新日期:1991-01-01 00:00:00

  • Finite element aided tracking of signal intensity changes in deforming intervertebral disc tissue.

    abstract::Tracking of signal intensity changes in soft tissue over time is often hampered by deformation of the tissue. In this study a method is described that uses finite element modeling to compensate for tissue deformation. The method is applied to the quantification of fluid redistribution in an intervertebral disc that de...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00251-8

    authors: Kingma I,Weinans H,van Dieën JH,de Boer RW

    更新日期:1998-01-01 00:00:00