Abstract:
:The objective of our study was to assess the feasibility of dynamic susceptibility contrast MR technique after bolus injection of SPIO and Gd-DOTA in a tumor model implanted in rats. Tumors were subcutaneously implanted in 24 rats. A FLASH sequence and EPI were evaluated. Different doses of AMI 227 and Gd-DOTA were assessed. Mean signal intensity vs. time curves were plotted. Well-shaped curves of the first pass of the contrast agent were only obtained with Gd-DOTA. According to these results it appears difficult to assess tumor blood volume with USPIO dynamic susceptibility contrast imaging.
journal_name
Magn Reson Imagingjournal_title
Magnetic resonance imagingauthors
Loubeyre P,De Jaegere T,Miao Y,Landuyt W,Marchal Gdoi
10.1016/s0730-725x(98)00197-0subject
Has Abstractpub_date
1999-05-01 00:00:00pages
627-31issue
4eissn
0730-725Xissn
1873-5894pii
S0730725X98001970journal_volume
17pub_type
杂志文章abstract::High signal-to-noise ratios (SNR) are essential for high-resolution anatomical and functional MRI. Phased arrays are advantageous for this but have the drawback that they often have inflexible and bulky configurations. Particularly in experiments where functional MRI is combined with simultaneous electrophysiology, sp...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2010.03.026
更新日期:2010-10-01 00:00:00
abstract::Glycosaminoglycan Chemical Exchange Saturation Transfer (gagCEST) is an important molecular MRI methodology developed to assess changes in cartilage GAG concentrations. The correction for B0 field inhomogeneity is technically crucial in gagCEST imaging. This study evaluates the accuracy of the B0 estimation determined...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2013.07.009
更新日期:2014-01-01 00:00:00
abstract::The mapping of the human brain white matter fiber networks relative to deep subcortical and cortical gray matter requires high spatial resolution which is challenged by the low signal-to-noise ratio. The purpose of this short report was to introduce a whole brain high spatial resolution diffusion tensor imaging (DTI) ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2008.10.007
更新日期:2009-06-01 00:00:00
abstract::Prostate MRI is an important tool to diagnose and characterize cancer. High local sensitivity and good parallel imaging performance are of paramount importance for diagnostic quality and efficiency. The purpose of this work was to evaluate stacked resonators as part of a surface receiver array for prostate MRI at 3 Te...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2018.07.010
更新日期:2018-11-01 00:00:00
abstract::We present a novel approach to the nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) analysis of complex samples with nontrivial distribution of longitudinal relaxation rate R(1). Parametrically enabled relaxation filters with double and multiple inversion (PERFIDI) aim to separate signals arising ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2006.12.001
更新日期:2007-05-01 00:00:00
abstract::H2O17 is a freely diffusible tracer and naturally occurring isotope of O16 detectable by MRI and has been shown to be useful for assessing cerebral perfusion in animal studies using direct and indirect MR detection techniques. However, earlier MR techniques are either not sensitive to changes in small concentrations o...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2003.09.005
更新日期:2004-02-01 00:00:00
abstract::T2-weighted images are considered the most sensitive for lesion detection at high field; however, long imaging time is problematic. Accordingly, the authors compared four breath-hold T2 or T2* weighted sequences comprising T2*-weighted FLASH, T2*-weighted PSIF, T2-weighted rapid spin echo (RASE), and T2-weighted Turbo...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(92)90371-6
更新日期:1992-01-01 00:00:00
abstract::Arterial spin labeling (ASL) perfusion fMRI data differ in important respects from the more familiar blood oxygen level-dependent (BOLD) fMRI data and require specific processing strategies. In this paper, we examined several factors that may influence ASL data analysis, including data storage bit resolution, motion c...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2007.07.003
更新日期:2008-02-01 00:00:00
abstract::Tissue water molecules reside in different biophysical compartments. For example, water molecules in the vasculature reside for variable periods of time within arteries, arterioles, capillaries, venuoles and veins, and may be within blood cells or blood plasma. Water molecules outside of the vasculature, in the extrav...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章,评审
doi:10.1016/j.mri.2007.02.006
更新日期:2007-07-01 00:00:00
abstract::Quantitative MRI of neuromelanin (NM) containing structures (referred to as NM-MRI) in the brainstem, namely the locus coeruleus (LC) and substantia nigra (SN), may assist with the early detection of Parkinson's disease (PD) and Alzheimer's disease (AD) as well as differential diagnosis in the early disease stages. In...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2014.07.003
更新日期:2014-12-01 00:00:00
abstract::The purpose of the study was to determine whether diffusion-weighted magnetic resonance imaging (DWI) could identify focal lesions that develop in ischemia-sensitive cerebral tissues during reperfusion following global brain ischemia. Localized 1H-Magnetic Resonance Spectroscopy (1H-MRS) measurements were also obtaine...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(96)00094-x
更新日期:1996-01-01 00:00:00
abstract::Magnetic resonance imaging (MRI) is a completely noninvasive modality that has shown significant promise for the evaluation of the cardiovascular system. Our imaging technique employed electrocardiographic (ECG) gating, which resulted in well-resolved images of the cardiac structures. Patients and animals with a varie...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(84)90002-x
更新日期:1984-01-01 00:00:00
abstract::The physiological parameters measured in the tracer kinetics modeling of data from a dynamic contrast-enhanced magnetic resonance (MR) breast exam (blood flow-extraction fraction product [FE], volume of the extracellular extravascular space [Ve], and blood volume [Vb]) may enable non-invasive diagnosis of breast cance...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(98)00130-1
更新日期:1998-11-01 00:00:00
abstract::Magnetic resonance (MR) microscopy of up to 1-5-microm resolutions have been reported previously. The tested phantom structures, however, had widths one order of magnitude bigger than the reported resolutions, e.g., spherical beads or capillary tubes of tens-of-micron diameters or wall thicknesses have been imaged. In...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2009.01.002
更新日期:2009-07-01 00:00:00
abstract:PURPOSE:To evaluate the application of high-resolution MRI methodology for characterizing the fluid velocity field and evaluate fluid shear field within a simplified in vitro model of a bone-implant interface. MATERIALS AND METHODS:The study used a specific micromotion canine bone implant that has been used for over a...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2005.11.001
更新日期:2006-06-01 00:00:00
abstract::The objective of this study was to measure T2* values of the normal human lung in vivo during breathhold using a rapid gradient-echo sequence with ultra-short echo times (TE). A sagittal slice of the right lung was imaged in six volunteers with various TE ranging from 0.5 ms to 5 ms using a clinical 1.5 Tesla MR scann...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(99)00047-8
更新日期:1999-09-01 00:00:00
abstract::Combining electrical stimulation with fMRI (esfMRI) has proven to be an important tool to study the global effects of electrical stimulation on neural networks in the brain. Here we extend our previous studies to stimulating the upper superior temporal sulcus (STS) in the anesthetized monkey. Our results show that sti...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2011.04.005
更新日期:2011-12-01 00:00:00
abstract::The analysis of functional magnetic resonance imaging (fMRI) data involves multiple stages of data pre-processing before the activation can be statistically detected. Spatial smoothing is a very common pre-processing step in the analysis of functional brain imaging data. This study presents a broad perspective on the ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2007.08.006
更新日期:2008-05-01 00:00:00
abstract:OBJECT:Virtual Phantom Magnetic Resonance Imaging (ViP MRI) is a method to generate reference signals on MR images, using external radiofrequency (RF) signals. The aim of this study was to assess the feasibility of ViP MRI to generate complex-data images of phantoms mimicking water-fat systems. MATERIALS AND METHODS:V...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2015.12.002
更新日期:2016-06-01 00:00:00
abstract::Brain asymmetry is a phenomenon well known for handedness and has been studied in motor cortices. However, few quantitative studies on asymmetrical cortical activity in motor areas have been conducted. In this study, we systematically investigated asymmetrical cortical activity in motor areas during sequential finger ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2007.03.024
更新日期:2007-12-01 00:00:00
abstract:INTRODUCTION:Glioma is the most common type of the primary CNS tumor. Radiotherapy is an important treatment measure after surgery. However, its highly invasive character is the main reason of postoperative recurrence. The aim of the study was to probe the correlation between the invasion ability and the metabolite cha...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2016.05.009
更新日期:2016-10-01 00:00:00
abstract::Dynamic contrast-enhanced MRI (DCE-MRI) was used to noninvasively evaluate the effects of AG-03736, a novel inhibitor of vascular endothelial growth factor (VEGF) receptor tyrosine kinases, on tumor microvasculature in a breast cancer model. First, a dose response study was undertaken to determine the responsiveness o...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2006.09.041
更新日期:2007-04-01 00:00:00
abstract::The fluorine nuclear magnetic resonance spin-lattice relaxation rate (1/T1) of the perfluorochemical blood substitute perfluorotripropylamine (FTPA) is very sensitive to oxygen tension. This presents the possibility of measuring blood oxygen tension by 19F MR imaging. We obtained oxygen-sensitive 19F NMR images of the...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(87)90005-1
更新日期:1987-01-01 00:00:00
abstract::Merkel cell carcinoma (MCC) is a rare malignant tumor of the skin and often is diagnosed histologically as lymphoma, melanoma and even metastatic small cell carcinoma of the lung (SCCL). Classified as a neuroendocrine tumor, clinically it originates in the head and neck region and may present with metastatic disease a...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(00)00176-4
更新日期:2000-10-01 00:00:00
abstract::A regularization strategy is described for generalized autocalibrating partially parallel acquisition (GRAPPA) that allows successful calibration using a small number of autocalibration signals (ACS). The approach requires certain nonlinear relationships between the GRAPPA coefficients to be satisfied, which increases...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2008.05.005
更新日期:2009-01-01 00:00:00
abstract::We have developed an in vivo longitudinally detected ESR (LODESR) imaging system operating at 700 MHz based on a loop-gap resonator and a pair of saddle-type pickup coils. A good linear relationship between the LODESR signal intensity and the applied power in a range up to 15.8 W was obtained. The detection of LODESR ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(97)82763-4
更新日期:1997-01-01 00:00:00
abstract::The non-Einstein diffusion behavior of water in a model biological tissue system, intact duck embryos, has been investigated by the use of an in vivo proton pulsed-gradient spin-echo (PGSE) MR imaging technique. Multiple-frame MR images of the intact duck embryos and control solution (0.5 mM CuSO4 doped water) were ac...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(93)90476-t
更新日期:1993-01-01 00:00:00
abstract::The application of MRI-visible paramagnetic tracers to reveal in vivo connectivity can provide important subject-specific information for multisite, multielectrode intracortical recordings in combined behavioral and physiology experiments. To establish the use of such tracers in the nonhuman primate, we recently compa...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2005.12.031
更新日期:2006-05-01 00:00:00
abstract::With the recent development of integrated positron emission tomography-magnetic resonance imaging (PET-MRI) scanners, new possibilities for quantitative molecular imaging of cancer are realized. However, the practical advantages and potential clinical benefits of the ability to record PET and MRI data simultaneously m...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章,评审
doi:10.1016/j.mri.2012.06.001
更新日期:2012-11-01 00:00:00
abstract:OBJECTIVE:In magnetic resonance-guided breast vacuum biopsies, the contrast agent for targeting suspicious lesions can typically be applied only once during an intervention, due to the slow elimination of the gadolinium chelate from the extracellular fluid space. This study evaluated the feasibility of diffusion-weight...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2016.12.006
更新日期:2017-05-01 00:00:00