New method for fast MR imaging of the knee.

Abstract:

:Thirty-five patients with suspected internal derangements of the knee were examined with conventional two-dimensional (2D) spin-echo magnetic resonance (MR) imaging techniques and a new rapid three-dimensional (3D) method called 3D FASTER (field echo acquisition with a short repetition time and echo reduction). A 9-minute 3D FASTER data acquisition achieves nearly isotropic voxels for the calculation of any desired image plane without a significant loss in image quality. Image contrast is optimized for visualization of knee anatomy in a single sequence. An image-processing workstation is used to speed the multiplanar image calculation and display for more efficient analysis of the complex 3D data set. The 3D FASTER images were superior or equal to 2D images (which took three times longer to acquire) in demonstrating meniscal tears, ligament tears, bone marrow disease, and osteochondral defects. The combined advantages of improved imaging capability and efficiency could make 3D FASTER imaging a routine MR method for knee imaging.

journal_name

Radiology

journal_title

Radiology

authors

Harms SE,Flamig DP,Fisher CF,Fulmer JM

doi

10.1148/radiology.173.3.2813780

subject

Has Abstract

pub_date

1989-12-01 00:00:00

pages

743-50

issue

3

eissn

0033-8419

issn

1527-1315

journal_volume

173

pub_type

杂志文章
  • Virtual Unenhanced Images at Dual-Energy CT: Influence on Renal Lesion Characterization.

    abstract::Background Dual-energy (DE) CT allows reconstruction of virtual noncontrast (VNC) images from a single-phase contrast agent-enhanced examination, potentially reducing the need for multiphasic CT to characterize renal lesions. However, data regarding diagnostic performance of VNC images for the characterization of rena...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2019181100

    authors: Meyer M,Nelson RC,Vernuccio F,González F,Farjat AE,Patel BN,Samei E,Henzler T,Schoenberg SO,Marin D

    更新日期:2019-05-01 00:00:00

  • Intracranial vasa vasorum: insights and implications for imaging.

    abstract::This review offers insight into the possible role of vasa vasorum in the development of intracranial vascular disease. Unique structural features of intracranial vessels and nourishment from the surrounding cerebrospinal fluid environment may account for the relative lack of intracranial vasa vasorum early in life. Ho...

    journal_title:Radiology

    pub_type: 杂志文章,评审

    doi:10.1148/radiol.13112310

    authors: Portanova A,Hakakian N,Mikulis DJ,Virmani R,Abdalla WM,Wasserman BA

    更新日期:2013-06-01 00:00:00

  • Internal derangement of the temporomandibular joint: detection by single-photon emission computed tomography. Work in progress.

    abstract::The diagnostic accuracy of both planar and single-photon emission computed tomography (SPECT) bone scintigraphy, radionuclide angiography, arthrography, and conventional radiography was evaluated in 36 patients with temporomandibular joint (TMJ) dysfunction undergoing preoperative testing. The sensitivity of SPECT bon...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.149.2.6226060

    authors: Collier BD,Carrera GF,Messer EJ,Ryan DE,Gingrass D,Angell D,Palmer DW,Isitman AT,Hellman RS

    更新日期:1983-11-01 00:00:00

  • Fetal and funicular vascular anomalies: identification with prenatal US.

    abstract::Vascular anomalies of the umbilical cord and fetus were evaluated with ultrasound in 11 fetuses. The anomalies included true knot of the cord (n = 1), umbilical vein varix (n = 1), persistent right umbilical vein (n = 1), and unilateral hypertrophy of the iliac artery in cases of a single umbilical artery (n = 8). One...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.173.2.2678250

    authors: Jeanty P

    更新日期:1989-11-01 00:00:00

  • The clinical usefulness of routine coronal and sagittal reconstructions in cranial computed tomography.

    abstract::In order to test a hypothesis that the routine use of one midsagittal and four preselected coronal reconstruction images would disclose lesions unsuspected on standard cranial computed tomography (CT) scans, 204 patient examinations were subjected to such multiplanar reconstruction manipulation; the original CT diagno...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.140.1.7244210

    authors: Baker HL Jr

    更新日期:1981-07-01 00:00:00

  • Metallic clip deployment during stereotactic breast biopsy: retrospective analysis.

    abstract:PURPOSE:To determine the visibility of presumably excised lesions on screen-film mammograms obtained after biopsy and to determine the accuracy of clip deployment on the basis of measurements obtained on routine pre- and postbiopsy mammograms. MATERIALS AND METHODS:One hundred eleven cases of core-needle biopsy with c...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.218.2.r01fe39510

    authors: Rosen EL,Vo TT

    更新日期:2001-02-01 00:00:00

  • Gynecomastoid hyperplasia: imaging findings in six patients.

    abstract::This case series describes the radiologic appearances of gynecomastoid hyperplasia of the breast in our experience. The clinical histories, breast images, and histopathologic findings in six women were reviewed. At mammography, there was no abnormality in two women, an enlarging asymmetric density in three women, and ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.214.2.r00fe24553

    authors: Selland DL,Korbin CD,Lester SC,Lerner MH,Gulizia JA,Kaelin CM,Meyer JE

    更新日期:2000-02-01 00:00:00

  • Ingested foreign bodies: removal by magnet.

    abstract::Metallic foreign bodies ingested by eight patients (seven children) were removed from the upper gastrointestinal tract by means of a magnet inserted into the end of an orogastric tube. No patient required hospitalization, anesthesia, surgery, or subsequent radiography, and all patients remained asymptomatic. In no cas...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.160.2.3726120

    authors: Volle E,Hanel D,Beyer P,Kaufmann HJ

    更新日期:1986-08-01 00:00:00

  • Contrast-enhanced MR imaging of the breast: comparison of two different doses of gadopentetate dimeglumine.

    abstract:PURPOSE:To optimize detection and diagnosis of breast lesions with contrast-enhanced magnetic resonance (MR) imaging. MATERIALS AND METHODS:A three-dimensional fast low-angle shot pulse sequence was used for a group comparison consisting of 76 high-dose (0.16 mmol gadopentetate dimeglumine per kilogram of body weight)...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.191.3.8184040

    authors: Heywang-Köbrunner SH,Haustein J,Pohl C,Beck R,Lommatzsch B,Untch M,Nathrath WB

    更新日期:1994-06-01 00:00:00

  • Local recurrence after sphincter-saving resection for rectal and rectosigmoid carcinoma. Value of various diagnostic methods.

    abstract::The authors reviewed 51 cases of local recurrence after sphincter-saving resection for rectal and rectosigmoid carcinoma to assess the sensitivity of current diagnostic procedures. A combination of follow-up serum CEA levels and rectoscopy was found to be most efficient during the first two years after surgery in term...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.155.2.3983380

    authors: Grabbe E,Winkler R

    更新日期:1985-05-01 00:00:00

  • Fractional moving blood volume: estimation with power Doppler US.

    abstract:PURPOSE:To estimate the fraction of moving blood in tissue with power Doppler ultrasound (US). MATERIALS AND METHODS:Power Doppler US measurements of moving scatterers in a flow tube were made as a function of successive dilutions of the perfusate. Measurements were normalized relative to the maximum Doppler power in ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.197.1.7568820

    authors: Rubin JM,Adler RS,Fowlkes JB,Spratt S,Pallister JE,Chen JF,Carson PL

    更新日期:1995-10-01 00:00:00

  • Continuous ultrasound B-scanning of palpable breast masses.

    abstract::Of 210 pathologically confirmed palpable breast masses examined by continuous ultrasound B-scanning using a 2.5- or 7-MHz transducer and mammography, fluid filled cysts more than 1 cm in diameter were diagnosed accurately in 75 cases. Of the 103 solid masses studied by echography, 31 were circumscribed (29 benign fibr...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/117.1.123

    authors: Cole-Beuglet C,Beique RA

    更新日期:1975-10-01 00:00:00

  • Spiral CT of the pancreas.

    abstract::Computed tomography (CT) is the modality of choice for evaluation of pancreatic disease. In this prospective study, images obtained with spiral CT, which enables examination of a region of the body in a single breath-hold, were compared with those obtained by means of dynamic CT with automatic table incrementation in ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.183.3.1584940

    authors: Dupuy DE,Costello P,Ecker CP

    更新日期:1992-06-01 00:00:00

  • Technical cost of radiologic examinations: analysis across imaging modalities.

    abstract:PURPOSE:To determine the individual technical costs of general diagnostic radiographic, ultrasonographic (US), computed tomographic (CT), magnetic resonance (MR) imaging, and scintigraphic examinations and interventional radiology. MATERIALS AND METHODS:The Radiology Cost and Productivity Benchmarking Study method of ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.216.1.r00jl18269

    authors: Saini S,Seltzer SE,Bramson RT,Levine LA,Kelly P,Jordan PF,Chiango BF,Thrall JH

    更新日期:2000-07-01 00:00:00

  • BI-RADS lexicon for US and mammography: interobserver variability and positive predictive value.

    abstract:PURPOSE:To retrospectively evaluate interobserver variability between breast radiologists by using terminology of the fourth edition of the Breast Imaging Reporting and Data System (BI-RADS) to categorize lesions on mammograms and sonograms and to retrospectively determine the positive predictive value (PPV) of BI-RADS...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2392042127

    authors: Lazarus E,Mainiero MB,Schepps B,Koelliker SL,Livingston LS

    更新日期:2006-05-01 00:00:00

  • Staging non-small cell lung cancer with whole-body PET.

    abstract:PURPOSE:To compare the accuracies of whole-body 2-[fluorine 18]fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) and conventional imaging (thoracic computed tomography [CT], bone scintigraphy, and brain CT or magnetic resonance [MR] imaging) in staging bronchogenic carcinoma. MATERIALS AND METHODS:With...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.212.3.r99se21803

    authors: Marom EM,McAdams HP,Erasmus JJ,Goodman PC,Culhane DK,Coleman RE,Herndon JE,Patz EF Jr

    更新日期:1999-09-01 00:00:00

  • Medullary carcinoma of the breast: mammographic and US appearance.

    abstract::Medullary carcinoma of the breast is an uncommon tumor, which may mimic a benign mass at both mammography and ultrasonography (US). A total of 24 medullary carcinomas visible at mammography appeared as round or oval, noncalcified masses with varying degrees of marginal lobulation. In six of the 24 patients, US demonst...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.170.1.2642350

    authors: Meyer JE,Amin E,Lindfors KK,Lipman JC,Stomper PC,Genest D

    更新日期:1989-01-01 00:00:00

  • Small-vessel radiography in situ with monochromatic synchrotron radiation.

    abstract:PURPOSE:To evaluate the usefulness of a radiographic system with monochromatic synchrotron radiation to depict small vessels and peripheral secretory ducts. MATERIALS AND METHODS:Radiography of various organs was tested in 14 anesthetized dogs and pancreatography was performed in an excised human pancreas by using the...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.201.1.8816540

    authors: Mori H,Hyodo K,Tanaka E,Uddin-Mohammed M,Yamakawa A,Shinozaki Y,Nakazawa H,Tanaka Y,Sekka T,Iwata Y,Handa S,Umetani K,Ueki H,Yokoyama T,Tanioka K,Kubota M,Hosaka H,Ishikawa N,Ando M

    更新日期:1996-10-01 00:00:00

  • Hyperthermic effects on DNA repair mechanisms.

    abstract::Studies have been carried out using neutral and alkaline sucrose density gradients to investigate the effect of 41 degree-43 degree C on the ability of Chinese hamster ovary cells to repair single (SSB) and double stranded DNA breaks (DSB) caused by exposure to ionizing radiation. The authors found that when hyperther...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/123.2.475

    authors: Corry PM,Robinson S,Getz S

    更新日期:1977-05-01 00:00:00

  • Unusual burns of the lower extremities caused by a closed conducting loop in a patient at MR imaging.

    abstract::An extremely rare occurrence of third-degree burns was induced in the medial calves of a male patient with unusual anatomy (after resection and radiation therapy of a liposarcoma) during conventional magnetic resonance (MR) imaging on a clinical 1.5-T MR system that operated without any external conductor present and ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.200.2.8685360

    authors: Knopp MV,Essig M,Debus J,Zabel HJ,van Kaick G

    更新日期:1996-08-01 00:00:00

  • Photographic method of recording radiation fields using the localizer light for illumination.

    abstract::By interposing a camera with a fish-eye lens between the collimator and the illuminated field, radiotherapy ports can be recorded using the localizer light for illumination. An acrylic mold of the camera was used to maintain alignment and immobilization during the necessarily long exposures. The authors consider this ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/123.3.801

    authors: Pantoja E,Frede T,Leininger V

    更新日期:1977-06-01 00:00:00

  • Pulmonary nodules: estimation of malignancy at thin-section helical CT--effect of computer-aided diagnosis on performance of radiologists.

    abstract:PURPOSE:To evaluate the effect of a computer-aided diagnosis (CAD) system on the diagnostic performance of radiologists for the estimation of the malignancy of pulmonary nodules on thin-section helical computed tomographic (CT) scans. MATERIALS AND METHODS:The institutional review board approved use of the CT database...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2383050167

    authors: Awai K,Murao K,Ozawa A,Nakayama Y,Nakaura T,Liu D,Kawanaka K,Funama Y,Morishita S,Yamashita Y

    更新日期:2006-04-01 00:00:00

  • Development and evaluation of phantom for verification of section thickness at thin-section MR imaging.

    abstract::The purpose of this study was to construct and evaluate a phantom for measurement of magnetic resonance (MR) imaging sections with thicknesses of 0.3-0.6 mm. The phantom consisted of 304 0.1-mm-thick disks, each of which had a single notch filled with a diluted solution of gadopentetate dimeglumine. Qualitative and qu...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2401050304

    authors: Lemke AJ,Kazi I,de Bary P,Bernhardt U,Foerster PI,Foerster M,Felix R

    更新日期:2006-08-01 00:00:00

  • "Missing" femoral condyle: an unusual sequela to neonatal osteomyelitis and septic arthritis.

    abstract::Growth deformities of the distal femur and unusual gait disturbances were observed in four girls who had had neonatal osteomyelitis and septic arthritis. In each case apparent absence or hypoplasia of one of the femoral condyles, as seen on plain radiographs, was associated with marked genu varum or genu valgum. Arthr...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.161.2.3763900

    authors: Singson RD,Berdon WE,Feldman F,Denton JR,Abramson S,Baker DH

    更新日期:1986-11-01 00:00:00

  • Lung abscess: CT-guided drainage.

    abstract::Lung abscesses were drained by means of catheters guided by computed tomography (CT) in 19 patients who still had sepsis despite standard medical therapy; all patients had received antibiotics for at least 5 days, and 11 of the 19 patients had undergone bronchoscopy. The abscess was cured (by clinical and radiographic...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.178.2.1987590

    authors: vanSonnenberg E,D'Agostino HB,Casola G,Wittich GR,Varney RR,Harker C

    更新日期:1991-02-01 00:00:00

  • Two-dimensional Shear-Wave Elastography Performance in the Noninvasive Evaluation of Liver Fibrosis in Patients with Chronic Hepatitis B: Comparison with Serum Fibrosis Indexes.

    abstract::Purpose To investigate the value of two-dimensional (2D) shear-wave elastography (SWE) in the assessment of hepatic fibrosis in patients with chronic hepatitis B (CHB) and to compare the diagnostic performance of this modality with that of liver fibrosis indexes. Materials and Methods The ethics committee approved thi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2016160131

    authors: Zhuang Y,Ding H,Zhang Y,Sun H,Xu C,Wang W

    更新日期:2017-06-01 00:00:00

  • Biliary stricture dilatation: multicenter review of clinical management in 73 patients.

    abstract::Eighty-nine biliary strictures in 73 patients who had undergone percutaneous balloon dilatation were reviewed to determine long-term patency rates and clinical management problems. The majority of dilatations were performed in patients with anastomotic strictures (n = 44), iatrogenic strictures (n = 28), and stricture...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.160.1.3715030

    authors: Mueller PR,vanSonnenberg E,Ferrucci JT Jr,Weyman PJ,Butch RJ,Malt RA,Burhenne HJ

    更新日期:1986-07-01 00:00:00

  • Angiographic diagnosis of fourth ventricle tumors.

    abstract::Twelve primary fourth ventricle tumors and 22 medulloblastomas occupying mainly the fourth ventricle were analyzed, with emphasis on the differential diagnosis, vascularity, and some unusual findings. Though both types of tumor often have identical manifestations, the correct diagnosis can be made in most cases by car...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/128.2.393

    authors: Numaguchi Y,Kishikawa T,Fukui M,Komaki S,Russell WJ,Ikeda J,Okudera T,Matsuura K,Kitamura K

    更新日期:1978-08-01 00:00:00

  • Modic changes on MR images as studied with provocative diskography: clinical relevance--a retrospective study of 2457 disks.

    abstract:PURPOSE:To assess the value of vertebral body endplate signal intensity (Modic) changes on magnetic resonance (MR) images in predicting a painful disk, with provocative diskography as the reference standard. MATERIALS AND METHODS:Lumbar spine diskograms and prediskogram MR images of 736 patients (2457 disks) were retr...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2503080474

    authors: Thompson KJ,Dagher AP,Eckel TS,Clark M,Reinig JW

    更新日期:2009-03-01 00:00:00

  • Peripheral arterial disease: meta-analysis of the diagnostic performance of MR angiography.

    abstract:PURPOSE:To summarize the overall diagnostic performance of magnetic resonance (MR) angiography in the evaluation of peripheral arteriosclerotic occlusive disease and to identify the most important sources of variation in diagnostic accuracy between studies. MATERIALS AND METHODS:A search strategy in MEDLINE and citati...

    journal_title:Radiology

    pub_type: 杂志文章,meta分析

    doi:10.1148/radiology.217.1.r00oc11105

    authors: Nelemans PJ,Leiner T,de Vet HC,van Engelshoven JM

    更新日期:2000-10-01 00:00:00