Mapping Hypoxia in Renal Carcinoma with Oxygen-enhanced MRI: Comparison with Intrinsic Susceptibility MRI and Pathology.

Abstract:

:Purpose To cross-validate T1-weighted oxygen-enhanced (OE) MRI measurements of tumor hypoxia with intrinsic susceptibility MRI measurements and to demonstrate the feasibility of translation of the technique for patients. Materials and Methods Preclinical studies in nine 786-0-R renal cell carcinoma (RCC) xenografts and prospective clinical studies in eight patients with RCC were performed. Longitudinal relaxation rate changes (∆R1) after 100% oxygen inhalation were quantified, reflecting the paramagnetic effect on tissue protons because of the presence of molecular oxygen. Native transverse relaxation rate (R2*) and oxygen-induced R2* change (∆R2*) were measured, reflecting presence of deoxygenated hemoglobin molecules. Median and voxel-wise values of ∆R1 were compared with values of R2* and ∆R2*. Tumor regions with dynamic contrast agent-enhanced MRI perfusion, refractory to signal change at OE MRI (referred to as perfused Oxy-R), were distinguished from perfused oxygen-enhancing (perfused Oxy-E) and nonperfused regions. R2* and ∆R2* values in each tumor subregion were compared by using one-way analysis of variance. Results Tumor-wise and voxel-wise ∆R1 and ∆R2* comparisons did not show correlative relationships. In xenografts, parcellation analysis revealed that perfused Oxy-R regions had faster native R2* (102.4 sec-1 vs 81.7 sec-1) and greater negative ∆R2* (-22.9 sec-1 vs -5.4 sec-1), compared with perfused Oxy-E and nonperfused subregions (all P < .001), respectively. Similar findings were present in human tumors (P < .001). Further, perfused Oxy-R helped identify tumor hypoxia, measured at pathologic analysis, in both xenografts (P = .002) and human tumors (P = .003). Conclusion Intrinsic susceptibility biomarkers provide cross validation of the OE MRI biomarker perfused Oxy-R. Consistent relationship to pathologic analyses was found in xenografts and human tumors, demonstrating biomarker translation. Published under a CC BY 4.0 license. Online supplemental material is available for this article.

journal_name

Radiology

journal_title

Radiology

authors

Little RA,Jamin Y,Boult JKR,Naish JH,Watson Y,Cheung S,Holliday KF,Lu H,McHugh DJ,Irlam J,West CML,Betts GN,Ashton G,Reynolds AR,Maddineni S,Clarke NW,Parker GJM,Waterton JC,Robinson SP,O'Connor JPB

doi

10.1148/radiol.2018171531

subject

Has Abstract

pub_date

2018-09-01 00:00:00

pages

739-747

issue

3

eissn

0033-8419

issn

1527-1315

journal_volume

288

pub_type

杂志文章
  • Quantitative digital subtraction angiography: two scanning techniques for correction of scattered radiation and veiling glare. Work in progress.

    abstract::Scattered radiation and veiling glare in digital subtraction angiography degrade contrast signals in a nonlinear and nonuniform way. This effect prohibits direct use of image data for accurate iodine measurement or energy subtraction imaging. Two techniques based on the use of scanning lead bars were proposed to measu...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.157.1.3898220

    authors: Shaw CG,Plewes DB

    更新日期:1985-10-01 00:00:00

  • Pulmonary abnormalities and PET data analysis: a retrospective study.

    abstract:PURPOSE:To assess methods of standard uptake ratio (SUR) calculation with 2-deoxy-2-[fluorine-18]fluoro-D-glucose (FDG) positron emission tomography (PET) in indeterminate focal pulmonary abnormalities. MATERIALS AND METHODS:One hundred ninety-seven adult patients with indeterminate pulmonary abnormalities had complet...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.202.2.9015070

    authors: Lowe VJ,Duhaylongsod FG,Patz EF,Delong DM,Hoffman JM,Wolfe WG,Coleman RE

    更新日期:1997-02-01 00:00:00

  • Results of computer-aided diagnosis of peripheral bronchial carcinoma.

    abstract::Radiographic images can be converted into numerical sequences that can be evalueate by computer to determine the significance of certain radiographic findings in peripheral pulmonary nodules. Of three methods (discriminant analysis. Bayes' theoroem, and the Calm system), discriminant analysis has proven the best with ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/125.3.583

    authors: Rotte KH,Meiske W

    更新日期:1977-12-01 00:00:00

  • Superior vena caval obstruction: detection using CT.

    abstract::A review of 210 chest computed tomographic (CT) examinations demonstrating upper chest masses revealed 16 cases of superior vena caval obstruction (SVCO); 11 of these were clinically occult. Two of the occult cases subsequently became clinically evident. Contrast-enhanced chest CT permits the diagnosis of clinically o...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.157.2.4048460

    authors: Bechtold RE,Wolfman NT,Karstaedt N,Choplin RH

    更新日期:1985-11-01 00:00:00

  • Thyroid gland tumor diagnosis at US elastography.

    abstract:PURPOSE:To prospectively evaluate the elastographic appearance of thyroid gland tumors and explore the potential sensitivity and specificity of ultrasonographic (US) elastography for differentiating benign and malignant tumors, with histopathologic analysis as the reference standard. MATERIALS AND METHODS:The study wa...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2363041248

    authors: Lyshchik A,Higashi T,Asato R,Tanaka S,Ito J,Mai JJ,Pellot-Barakat C,Insana MF,Brill AB,Saga T,Hiraoka M,Togashi K

    更新日期:2005-10-01 00:00:00

  • Differentiating benign from malignant solid breast masses: comparison of two-dimensional and three-dimensional US.

    abstract:PURPOSE:To compare prospectively obtained static two-dimensional (2D) and three-dimensional (3D) ultrasonographic (US) images in the diagnostic performance of radiologists with respect to the differentiation of benign from malignant solid breast masses with histopathologic examination as the reference standard. MATERI...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2401050743

    authors: Cho N,Moon WK,Cha JH,Kim SM,Han BK,Kim EK,Kim MH,Chung SY,Choi HY,Im JG

    更新日期:2006-07-01 00:00:00

  • CT colonography: multiobserver diagnostic performance.

    abstract:PURPOSE:To prospectively evaluate multiobserver diagnostic performance and reader agreement for colorectal polyp detection in a well-characterized cohort of patients with increased number of polyps, compared with an average-risk patient, with colonoscopy as the reference standard. MATERIALS AND METHODS:A cohort of 70 ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2252011625

    authors: McFarland EG,Pilgram TK,Brink JA,McDermott RA,Santillan CV,Brady PW,Heiken JP,Balfe DM,Weinstock LB,Thyssen EP,Littenberg B

    更新日期:2002-11-01 00:00:00

  • Digital Compared with Screen-Film Mammography: Measures of Diagnostic Accuracy among Women Screened in the Ontario Breast Screening Program.

    abstract:PURPOSE:To compare measures of diagnostic accuracy between large concurrent cohorts of women screened with digital computed radiography (CR), direct radiography (DR), and screen-film mammography (SFM). MATERIALS AND METHODS:This study was approved by the University of Toronto Research Ethics Board; informed consent wa...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015150733

    authors: Prummel MV,Muradali D,Shumak R,Majpruz V,Brown P,Jiang H,Done SJ,Yaffe MJ,Chiarelli AM

    更新日期:2016-02-01 00:00:00

  • Treated thymic lymphoma: comparison of MR imaging with CT.

    abstract:PURPOSE:To determine the appearance of treated thymic lymphoma at magnetic resonance (MR) imaging and to compare the results with findings from posttherapy computed tomography (CT) and clinical outcome. MATERIALS AND METHODS:MR images and CT scans in 25 patients with thymic lymphoma were reviewed. Dimensions of residu...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.203.2.9114090

    authors: Spiers AS,Husband JE,MacVicar AD

    更新日期:1997-05-01 00:00:00

  • Lung abscess: CT-guided drainage.

    abstract::Lung abscesses were drained by means of catheters guided by computed tomography (CT) in 19 patients who still had sepsis despite standard medical therapy; all patients had received antibiotics for at least 5 days, and 11 of the 19 patients had undergone bronchoscopy. The abscess was cured (by clinical and radiographic...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.178.2.1987590

    authors: vanSonnenberg E,D'Agostino HB,Casola G,Wittich GR,Varney RR,Harker C

    更新日期:1991-02-01 00:00:00

  • Gastrointestinal tract focal mass lesions: role of CT and barium evaluations.

    abstract::Fifty-eight patients with focal mass lesions involving the gastrointestinal tract were studied retrospectively. The diagnostic value of CT scans was seen by assessing the barium studies alone, then by combined review of radiographs and CT scans. Patient management decision making was similarly evaluated. CT scanning a...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.158.3.3753800

    authors: Coscina WF,Arger PH,Levine MS,Herlinger H,Cohen S,Coleman BG,Mintz MC

    更新日期:1986-03-01 00:00:00

  • Effect of electrocardiogram triggering on reproducibility of coronary artery calcium scoring.

    abstract:PURPOSE:To test the hypothesis that computed tomographic (CT) scanning during early rather than middle diastole can significantly reduce the interscan variability of coronary artery calcium (CAC) scores. MATERIALS AND METHODS:Five hundred thirty-eight patients were initially enrolled; 282 of them were found to have CA...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1148/radiol.2203001129

    authors: Mao S,Bakhsheshi H,Lu B,Liu SC,Oudiz RJ,Budoff MJ

    更新日期:2001-09-01 00:00:00

  • Focal-spot measurement: comparison of slit, pinhole, and star resolution pattern techniques.

    abstract::The National Electrical Manufacturers Association (NEMA) has established a new standard for x-ray tube focal-spot measurements using a focal-spot camera with a slit instead of a pinhole. Measurements from the slit focal-spot camera are compared and star resolution pattern techniques for 50 focal spots. In addition, me...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.165.1.3628780

    authors: Everson JD,Gray JE

    更新日期:1987-10-01 00:00:00

  • Renal arterial rupture complicating transluminal angioplasty: successful conservative management.

    abstract::Vessel rupture complicating transluminal angioplasty is an uncommon event, especially in the renal artery. The authors report such a case, which was treated with immediate balloon tamponade and did not require surgical intervention. Possible causes and appropriate management are discussed, as well as the need for repo...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.174.3.174-3-983

    authors: Ashenburg RJ,Blair RJ,Rivera FJ,Weigele JB

    更新日期:1990-03-01 00:00:00

  • Visualization of the bile ducts using focused ultrasound.

    abstract::The feasibility of using focused ultrasound for studying structures as small as biliary ducts and correlative radiological and ultrasonic studies of the common and larger hepatic ducts are presented. Patients whose bile ducts were visualized on intravenous or T-tube cholangiography or oral cholecystography underwent r...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/118.1.155

    authors: Reid MH

    更新日期:1976-01-01 00:00:00

  • Fetal cerebral ventriculomegaly: misidentification of the true medial boundary of the ventricle at US.

    abstract:PURPOSE:To investigate the implications of mistaking the medial surface of the cerebral hemisphere for the medial wall of the lateral ventricle at antenatal ultrasonography (US) and to identify US clues that might help avoid this interpretive error. MATERIALS AND METHODS:In 50 second- and third-trimester fetuses, a di...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.205.3.9393540

    authors: Hertzberg BS,Kliewer MA,Bowie JD

    更新日期:1997-12-01 00:00:00

  • The Kimray-Greenfield filter: evaluation by duplex real-time/pulsed Doppler ultrasound.

    abstract::The Kimray-Greenfield filter is a wire cage which is inserted into the inferior vena cava (IVC) to prevent thrombi originating in pelvic and leg veins from embolizing to the lungs. Duplex real-time/pulsed Doppler ultrasound was used to evaluate placement and function in 38 patients (46 examinations). Real-time examina...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.148.1.6856840

    authors: Pasto ME,Kurtz AB,Jarrell BE,Dubbins PA,Rifkin MD,Cole-Beuglet C,Baltarowich O,Goldberg BB

    更新日期:1983-07-01 00:00:00

  • Chronic lumbar extradural hematoma: CT findings.

    abstract::The CT findings in two surgically proved cases of spontaneous chronic extradural hematoma are presented. Tapered convex margins, a length greater than 2 cm, and associated normal intervertebral disks are findings that help distinguish chronic extradural hematoma from an extruded disk. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.148.3.6878690

    authors: Levitan LH,Wiens CW

    更新日期:1983-09-01 00:00:00

  • Intracranial lesions: flow-related enhancement on MR images using time-of-flight effects.

    abstract::Many physico-anatomic variables and instrument parameters influence the relative magnetic resonance signal intensity of vascular channels. The interaction of these mechanisms is complex, but their composite effects can be accounted for by two main categories of flow phenomena: time-of-flight effects and spin-phase cha...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.161.3.3786730

    authors: Kucharczyk W,Kelly WM,Davis DO,Norman D,Newton TH

    更新日期:1986-12-01 00:00:00

  • Interfacing a programmable desk calculator to a hard-wired data system.

    abstract::The primary disadvantage of hard-wired data systems for use in nuclear medicine is the fact that that the data contained in the memory bank are not accessible to the user and often must be processed mathematically before they can be employed in interpretation, particularly in dynamic studies. The authors describe a re...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/118.1.225

    authors: Shearer D,Rollins M

    更新日期:1976-01-01 00:00:00

  • Percutaneous Image-guided Laser Photocoagulation of Spinal Osteoid Osteoma: A Single-Institution Series.

    abstract:PURPOSE:To retrospectively evaluate the safety and efficacy of percutaneous image-guided laser photocoagulation for the treatment of spinal osteoid osteoma (OO) in proximity to neural structures. MATERIALS AND METHODS:This study was institutional review board-approved with waivers of informed consent. From January 199...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015150491

    authors: Tsoumakidou G,Thénint MA,Garnon J,Buy X,Steib JP,Gangi A

    更新日期:2016-03-01 00:00:00

  • Coronary sinus-left atrial window.

    abstract::Left atrial-coronary sinus fenestration is a rare cause of a left-to-right or right-to-left shunt which occurs most commonly with a persistent left superior vena cava. These fenestrations may represent the only pathway for an obligatory right-to-left or left-to-right shunt in atrioventricular valve atresia. Four cases...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.135.2.7367620

    authors: Nath PH,Delaney DJ,Zollikofer C,Ben-Sachar G,Castaneda-Zuniga W,Formanek A,Amplatz K

    更新日期:1980-05-01 00:00:00

  • Laminectomy: effects on postoperative technetium and gallium scintigraphy.

    abstract::Bone scans using Tc-99m diphosphonate were found to become abnormal within 2 weeks after laminectomy in less than half of patients regardless of the extent of the operation. The degree of new uptake equaled that of the sacroiliac joints in only one of 19 patients with a normal preoperative scan. However, the Ga-67 cit...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.151.3.6585860

    authors: Silberstein EB,Schneider HJ,Khodadad G,DeVries D,Rauf GC,Noll R

    更新日期:1984-06-01 00:00:00

  • Liver biopsy through the femoral vein.

    abstract::A technique to perform a liver biopsy through the femoral vein with the Mansfield biopsy forceps is described. Nine liver biopsy procedures were performed in seven patients who were considered at high risk of bleeding, precluding a conventional transperitoneal biopsy. The technique is an easy, safe, and well-tolerated...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.169.3.3187010

    authors: Mewissen MW,Lipchik EO,Schreiber ER,Varma RR

    更新日期:1988-12-01 00:00:00

  • Benign and malignant breast lesions: differentiation with echo-planar MR imaging.

    abstract:PURPOSE:To quantify dynamic enhancement of breast lesions with echo-planar and conventional magnetic resonance (MR) imaging, to correlate these data with histologic findings and vessel density, and to evaluate MATERIALS AND METHODS:Twenty female patients with 22 breast lesions underwent conventional and MR echo-planar...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.197.1.7568850

    authors: Hulka CA,Smith BL,Sgroi DC,Tan L,Edmister WB,Semple JP,Campbell T,Kopans DB,Brady TJ,Weisskoff RM

    更新日期:1995-10-01 00:00:00

  • Angiographic findings in multiple bile-duct hamartomas of the liver.

    abstract::The angiographic appearance in a patient with multiple bile-duct hamartomas of the liver is described. The lesions showed abnormal vascularity, consisting of grapelike clusters of small rings, which could be confused with other benign and malignant conditions demonstrable by angiography; however, it may ultimately pro...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/116.1.41

    authors: McLoughlin MJ,Phillips MJ

    更新日期:1975-07-01 00:00:00

  • Atypical small hemangiomas of the liver: "bright dot" sign at two-phase spiral CT.

    abstract:PURPOSE:To determine if a tiny enhancing dot is characteristic of small hemangiomas with low attenuation during the hepatic arterial phase (HAP) and portal venous phase (PVP) of two-phase spiral computed tomography (CT). MATERIALS AND METHODS:Among 249 consecutive patients with 377 hemangiomas who underwent two-phase ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.208.2.9680590

    authors: Jang HJ,Choi BI,Kim TK,Yun EJ,Kim KW,Han JK,Han MC

    更新日期:1998-08-01 00:00:00

  • Global small bowel motility: assessment with dynamic MR imaging.

    abstract:PURPOSE:To assess the repeatability in human volunteers of software-quantified small bowel motility captured with magnetic resonance (MR) imaging and to test the ability to detect changes in motility induced by pharmacologic agents. MATERIALS AND METHODS:The study was approved by the Royal Free Research Ethics Committ...

    journal_title:Radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1148/radiol.13130151

    authors: Menys A,Taylor SA,Emmanuel A,Ahmed A,Plumb AA,Odille F,Alam A,Halligan S,Atkinson D

    更新日期:2013-11-01 00:00:00

  • The role of the radiologist in coronary angiography.

    abstract::Radiology chiefs at hospitals with open heart surgery programs were queried to ascertain both current and desired degrees of participation by radiologists in coronary angiography. While current participation is limited, respondents indicated a desire to achieve increased active participation. Opposition of cardiologis...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/125.2.313

    authors: Levin DC,Adams DF,Abrams HL

    更新日期:1977-11-01 00:00:00

  • Detection of Steatohepatitis in a Rat Model by Using Spectroscopic Shear-Wave US Elastography.

    abstract::Purpose To compare low- versus high-frequency ultrasonographic (US) elastography for detection of steatohepatitis in rats by using histopathologic findings as the reference standard. Materials and Methods Between March and September 2014, after receiving approval from the institutional animal care committee, 60 male S...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2016160308

    authors: Kazemirad S,Zhang E,Nguyen BN,Bodson-Clermont P,Destrempes F,Trudel D,Cloutier G,Tang A

    更新日期:2017-03-01 00:00:00