Abstract:
PURPOSE:To compare measures of diagnostic accuracy between large concurrent cohorts of women screened with digital computed radiography (CR), direct radiography (DR), and screen-film mammography (SFM). MATERIALS AND METHODS:This study was approved by the University of Toronto Research Ethics Board; informed consent was not required. Three concurrent cohorts of women aged 50-74 years who were screened from 2008-2009 in the Ontario Breast Screening Program with SFM (487,334 screening examinations, 403,688 women), DR (254,758 screening examinations, 220,520 women), or CR (74,140 screening examinations, 64,210 women) were followed for 2 years or until breast cancer diagnosis. Breast cancers were classified as screening-detected or interval on the basis of the woman's final screening and assessment results. Interval cancer rate (per 10 000 negative screening examinations), sensitivity, and specificity were compared across the cohorts by using mixed-effects logistic regression analysis. RESULTS:Interval cancer rates were higher, although not significantly so, for CR (15.2 per 10,000; 95% confidence interval [CI]: 12.8, 17.8) and were similar for DR (13.7 per 10,000; 95% CI: 12.4, 15.0) compared with SFM (13.0 per 10,000; 95% CI: 12.1, 13.9). For CR versus SFM, specificity was similar while sensitivity was significantly lower (odds ratio [OR] = 0.62; 95% CI: 0.47, 0.83; P = .001), particularly for invasive cancers detected at a rescreening examination, for women with breast density of less than 75%, for women with no family history, and for postmenopausal women. For DR versus SFM, sensitivity was similar while specificity was lower (OR = 0.92; 95% CI: 0.87, 0.98; P = .01), particularly for rescreening examinations, for women aged 60-74 years, for women with breast density of less than 75%, for women with a family history, and for women who were postmenopausal. CONCLUSION:Given the 38% lower sensitivity of CR imaging systems compared with SFM, programs should assess the continued use of this technology for breast screening.
journal_name
Radiologyjournal_title
Radiologyauthors
Prummel MV,Muradali D,Shumak R,Majpruz V,Brown P,Jiang H,Done SJ,Yaffe MJ,Chiarelli AMdoi
10.1148/radiol.2015150733subject
Has Abstractpub_date
2016-02-01 00:00:00pages
365-73issue
2eissn
0033-8419issn
1527-1315journal_volume
278pub_type
杂志文章相关文献
RADIOLOGY文献大全abstract::The authors retrospectively evaluated 12 patients with congenital (neonatal) neuroblastoma to assess the utility of newer imaging modalities. Findings at prenatal ultrasound (US), performed in four patients, were nonspecific (hydramnios and hydrops fetalis) in two and consistent with a suprarenal mass (one solid, one ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.175.2.2183280
更新日期:1990-05-01 00:00:00
abstract::Background Growing evidence indicates an association between cerebral microhemorrhages (MHs) and amyloid β accumulation in Alzheimer disease (AD), but to the knowledge of the authors the association with tau burden is unknown. Purpose To investigate the association between cerebral MH load and tau pathologic structure...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2020191904
更新日期:2020-07-01 00:00:00
abstract:PURPOSE:To evaluate major geometric variations in multiple intracavitary applications for carcinoma of the cervix. MATERIALS AND METHODS:Orthogonal radiographs were reviewed of 17 consecutive patients with carcinoma of the cervix treated with 70 applications of high-dose-rate brachytherapy. In seven patients, consciou...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.195.2.7724760
更新日期:1995-05-01 00:00:00
abstract::Twenty-three patients were prospectively examined with ultrasound (US) for acute or recurrent Achilles tendon symptoms. Three types of pathologic conditions of the Achilles tendon were found: tendinitis/tenosynovitis, acute tendon trauma, and postoperative changes. US appears to enable differentiation of these conditi...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.159.3.3517960
更新日期:1986-06-01 00:00:00
abstract:PURPOSE:To prospectively assess the accuracy of unenhanced magnetic resonance (MR) imaging in the detection and localization of labral injuries. MATERIALS AND METHODS:One hundred three patients with clinically suspected shoulder injuries were prospectively examined with unenhanced MR imaging. A combination of gradient...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.200.2.8685350
更新日期:1996-08-01 00:00:00
abstract::Midline activity low in the pelvis seen on Ga-67 scans is frequently attributed to colonic excretion of radionuclide. We have seen two cases of infectious prostatitis with focal uptake of Ga-67 within the prostate gland. We describe a technique of using limited quantities of barium administered by enema and appropriat...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.152.2.6739830
更新日期:1984-08-01 00:00:00
abstract::One hundred twenty-six patients with the diagnosis of lymphoma underwent staging with both lymphangiography and computed tomography (CT) of the abdomen and pelvis. These patients were retrospectively studied to determine the optimal imaging modality for follow-up. Six hundred seventy-four CT scans were correlated with...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.164.3.3615860
更新日期:1987-09-01 00:00:00
abstract::Four patients with proved osteopetrosis (three with the infantile malignant form and one with the benign form) were examined with magnetic resonance imaging at 1.5 T. All patients were studied in the coronal and sagittal planes using both short and long repetition time/echo time sequences. The infantile malignant form...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.161.1.3763870
更新日期:1986-10-01 00:00:00
abstract::A transhepatic computed-tomographic-guided biopsy of a right adrenal mass is described. This method is simpler to perform than the usual posterior biopsy carried out with the patient prone and is less likely to cause a complicating pneumothorax. In seven of eight patients with right adrenal masses, adrenal tissue was ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.148.2.6867360
更新日期:1983-08-01 00:00:00
abstract::The radiographic patterns of vertebral-body collapse and/or endplate deformity were examined in 99 autopsy specimens of the thoracolumbar spine with benign and malignant disease. Angling of endplates was found to be highly predictive of underlying malignancy, whereas concavity was more suggestive of benign disease, fo...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.160.2.3726130
更新日期:1986-08-01 00:00:00
abstract:PURPOSE:To determine whether the "accordion sign" is a specific computed tomographic (CT) sign of Clostridium difficile colitis. MATERIALS AND METHODS:Fifty-seven patients with CT evidence of severe colitis, as judged by colonic wall thickening, an abnormal haustral pattern, the target sign, and stranding of the peric...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.211.3.r99jn32743
更新日期:1999-06-01 00:00:00
abstract::Purpose To compare PET/MR hypoperfusion and hypometabolism in patients with Alzheimer disease (AD) and mild cognitive impairment (MCI) compared with healthy control (HC) participants. Materials and Methods Maps of cerebral blood flow (CBF; pulsed arterial spin-labeling [ASL] MRI), glucose metabolism (fluorine 18 [18F]...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2018170575
更新日期:2018-07-01 00:00:00
abstract:PURPOSE:To prospectively investigate the clinical efficacy of using diffuse optical tomography (DOT) and ultrasonographic (US) localization with conventional US to differentiate malignant solid breast lesions from those that are benign. MATERIALS AND METHODS:The study was approved by the institutional review board and...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.12120086
更新日期:2012-11-01 00:00:00
abstract::The measurement of supine pedal venous pressure as a screening test for deep venous thrombosis is re-evaluated. In 83 extremities studied in 50 patients, the false-positive rate was 62%, the false-negative rate 8%. Chronic venous disease, whatever its etiology but particularly in association with the post-phlebitis sy...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/131.1.75
更新日期:1979-04-01 00:00:00
abstract:PURPOSE:To evaluate the effect of computer-aided diagnosis (CAD) on radiologists' detection of pulmonary nodules. MATERIALS AND METHODS:Fifty chest computed tomographic (CT) examination cases were used. The mean nodule size was 0.81 cm +/- 0.60 (SD) (range, 0.3-2.9 cm). Alternative free-response receiver operating cha...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2302030049
更新日期:2004-02-01 00:00:00
abstract:PURPOSE:To evaluate the use of ultrasound (US) for detection of wooden foreign bodies implanted in cadaveric specimens. MATERIALS AND METHODS:Wooden foreign bodies were randomly placed in the plantar soft tissues of three cadaver feet by using 5-mm-long incisions. Ten foreign bodies were 2.5 x 1.0 mm (length x diamete...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.206.1.9423650
更新日期:1998-01-01 00:00:00
abstract:PURPOSE:To assess the outcome of interventional radiologic placement of tunneled hemodialysis catheters via the right internal jugular vein. MATERIALS AND METHODS:In 194 patients, the catheter was placed via the right internal jugular vein unless thrombosis was present. Real-time ultrasound-guided puncture and fluoros...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.203.2.9114110
更新日期:1997-05-01 00:00:00
abstract:PURPOSE:To compare quantified measurements with color Doppler ultrasonography (US) with those obtained with conventional duplex US in the differential diagnosis of suspect lesions in the breast. MATERIALS AND METHODS:A computer-assisted protocol was used to calculate the color pixel density (CPD) and the mean color va...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.192.3.8058950
更新日期:1994-09-01 00:00:00
abstract::Purpose To evaluate the diagnostic accuracy of the quantitative parameter standardized uptake value (SUV) at single photon emission computed tomography (SPECT)/computed tomography (CT) for the evaluation of temporomandibular joint (TMJ) disorder (TMD). Materials and Methods This study was approved by the institutional...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2016152294
更新日期:2016-09-01 00:00:00
abstract::Extracorporeal shock wave lithotripsy (ESWL), either alone or in combination with percutaneous or retrograde techniques, has rapidly become the procedure of choice for the treatment of intrarenal and upper ureteral calculi. Complications have been few so far and usually have been urinary obstructions or hemorrhages. M...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.163.3.3575710
更新日期:1987-06-01 00:00:00
abstract:PURPOSE:To measure the safety and effectiveness of conscious sedation in order to assess utilization and the effect on magnetic resonance (MR) imaging examinations. MATERIALS AND METHODS:A database of conscious sedation records for MR imaging at the Johns Hopkins Hospital, Baltimore, Md, from 1991 to 1998 was searched...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.216.3.r00se45645
更新日期:2000-09-01 00:00:00
abstract::Using a dose fractionation scheme patterned after the current regimen for treatment of disseminated non-Hodgkin lymphoma, the authors studied the effects of irradiation on progenitor and effector cells for hematopoiesis in five-month-old BC3F1 mice. Fractions of 20 or 50 rad (0.2 or 0.5 Gy) total body irradiation were...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.134.2.7352240
更新日期:1980-02-01 00:00:00
abstract:PURPOSE:To determine whether measurements of skewness, kurtosis, and mean lung attenuation on thin-section computed tomographic (CT) histograms in patients with idiopathic pulmonary fibrosis (IPF) correlate with pulmonary physiologic abnormality in a nonspirometrically controlled multicenter study. MATERIALS AND METHO...
journal_title:Radiology
pub_type: 临床试验,杂志文章,多中心研究
doi:10.1148/radiol.2282020274
更新日期:2003-08-01 00:00:00
abstract::Internal contamination by 131I among the personnel in a nuclear medicine laboratory was surveyed from January to July, 1979. Because of the formulation change made by the manufacturer in April to reduce volatility, it was possible to study two different therapeutic solutions of 131I. Internal contamination of personne...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.137.3.7444060
更新日期:1980-12-01 00:00:00
abstract::Purpose To assess the patient-dependent accuracy of atlas-based attenuation correction (ATAC) for brain positron emission tomography (PET) in an integrated time-of-flight (TOF) PET/magnetic resonance (MR) imaging system. Materials and Methods Thirty recruited patients provided informed consent in this institutional re...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2017161603
更新日期:2017-07-01 00:00:00
abstract::This introduction to biostatistics and measurement is the first in a series of articles designed to provide Radiology readers with a basic understanding of statistical concepts. Although most readers of the radiology literature know that application of study results to their practice requires an understanding of stati...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2252010933
更新日期:2002-11-01 00:00:00
abstract::To assess the potential role of ultrasound (US) in evaluating transjugularly inserted intrahepatic portosystemic shunts, the authors performed sonographic, including duplex and color Doppler, studies in 23 patients. Imaging was performed before, during the first week after, and 2-3 months after shunt placement. The pr...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.186.2.8421760
更新日期:1993-02-01 00:00:00
abstract:PURPOSE:To determine the diagnostic accuracy of bedside chest radiography in patients who develop severe pulmonary complications while undergoing therapy for leukemia. MATERIALS AND METHODS:The authors studied 45 patients, aged 21 years and younger, who died of leukemia or of treatment complications and for whom autop...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.193.1.8090880
更新日期:1994-10-01 00:00:00
abstract::Purpose To investigate whether whole-liver enhancing tumor burden [ETB] can serve as an imaging biomarker and help predict survival better than World Health Organization (WHO), Response Evaluation Criteria in Solid Tumors (RECIST), modified RECIST (mRECIST), and European Association for the Study of the Liver (EASL) m...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2016160838
更新日期:2017-06-01 00:00:00
abstract:PURPOSE:To compare the occurrence of several central sulcus variants and to assess the reproducibility of a sulcal pattern named the power button sign (PBS) in patients with type 2 focal cortical dysplasia (FCD2) and healthy control subjects. MATERIALS AND METHODS:The local institutional review board approved the stud...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.14140773
更新日期:2015-02-01 00:00:00