Detection of Steatohepatitis in a Rat Model by Using Spectroscopic Shear-Wave US Elastography.

Abstract:

:Purpose To compare low- versus high-frequency ultrasonographic (US) elastography for detection of steatohepatitis in rats by using histopathologic findings as the reference standard. Materials and Methods Between March and September 2014, after receiving approval from the institutional animal care committee, 60 male Sprague-Dawley rats were fed either a standard chow for 4 weeks or a methionine- and choline-deficient diet for 1, 4, 8, or 12 weeks to induce a continuum of steatohepatitis severity. Liver shear stiffness was assessed in vivo by using US elastography at low (40-130-Hz) and high (130-220-Hz) frequencies. Histologic features (steatosis, inflammation, and fibrosis) and modified nonalcoholic steatohepatitis categories were used as reference standards. Definite steatohepatitis was divided into steatohepatitis with fibrosis stage 1 or lower and stage 2 and higher. Analyses included the Kendall τ correlation, multivariable linear regression analyses, Kruskal-Wallis rank sum test, and post hoc Dunn test with Holm correction. Results Correlations between liver shear stiffness and histologic features were higher at high frequencies than at low frequencies (low frequency: 0.08, 0.24, and 0.20 for steatosis, inflammation, and fibrosis, respectively; high frequency: 0.11, 0.35, and 0.50, respectively). The absolute value of multivariable regression coefficients was higher at high frequencies for the presence of steatosis, inflammation grade, and fibrosis stage (low frequency: -0.475, 0.157, and 0.209, respectively; high frequency: -0.893, 0.357, and 0.447, respectively). The model fit was better at high frequencies (adjusted R2 = 0.57) than at low frequencies (adjusted R2 = 0.21). There was a significant difference between steatohepatitis categories at both low and high frequencies (P = .022 and P < .001, respectively). Conclusion Liver shear stiffness measured with US elastography provided better distinction of steatohepatitis categories at high frequencies than at low frequencies. Further, liver shear stiffness decreased with steatosis and increased with inflammation and fibrosis at both low and high frequencies. © RSNA, 2016 Online supplemental material is available for this article.

journal_name

Radiology

journal_title

Radiology

authors

Kazemirad S,Zhang E,Nguyen BN,Bodson-Clermont P,Destrempes F,Trudel D,Cloutier G,Tang A

doi

10.1148/radiol.2016160308

subject

Has Abstract

pub_date

2017-03-01 00:00:00

pages

726-733

issue

3

eissn

0033-8419

issn

1527-1315

journal_volume

282

pub_type

杂志文章
  • MR imaging: quality assessment method and ratings at 33 centers.

    abstract:PURPOSE:To outline a quality assessment method with peer review for magnetic resonance (MR) imaging. MATERIALS AND METHODS:Thirty-three providers in the Philadelphia area were rated on a random sample of 132 brain, 124 cervical spine, and 113 lower extremity MR imaging examinations performed during 1990. Blinded peer ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.196.1.7784570

    authors: Friedman DP,Rosetti GF,Flanders AE,Piccoli CW,Rao VM,Mitchell DG,Tartaglino LM,Gonzalez CF,Schweitzer ME,Mishkin MM

    更新日期:1995-07-01 00:00:00

  • Kimray-Greenfield vena cava filter: percutaneous introduction.

    abstract::A percutaneous technique is described for the introduction of Kimray-Greenfield filters into the vena cava through either the internal jugular or femoral approach. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.151.2.6709930

    authors: Tadavarthy SM,Castaneda-Zuniga W,Salomonowitz E,Lund G,Cragg A,Hunter D,Coleman C,Amplatz K

    更新日期:1984-05-01 00:00:00

  • Changes in primary breast cancer heterogeneity may augment midtreatment MR imaging assessment of response to neoadjuvant chemotherapy.

    abstract:PURPOSE:To evaluate whether changes in magnetic resonance (MR) imaging heterogeneity may aid assessment for pathologic complete response (pCR) to neoadjuvant chemotherapy (NACT) in primary breast cancer and to compare pCR with standard Response Evaluation Criteria in Solid Tumors response. MATERIALS AND METHODS:Instit...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.14130569

    authors: Parikh J,Selmi M,Charles-Edwards G,Glendenning J,Ganeshan B,Verma H,Mansi J,Harries M,Tutt A,Goh V

    更新日期:2014-07-01 00:00:00

  • Sonoelastography of the Common Flexor Tendon of the Elbow with Histologic Agreement: A Cadaveric Study.

    abstract::Purpose To determine the correlation of the results of conventional B-mode ultrasonography (US) and compression sonoelastography with histologic results in common flexor tendons of the elbow in human cadavers. Materials and Methods Twenty-five common flexor tendons were evaluated in 16 fresh, unembalmed cadavers of 11...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2016160139

    authors: Klauser AS,Pamminger MJ,Halpern EJ,Abd Ellah MMH,Moriggl B,Taljanovic MS,Deml C,Sztankay J,Klima G,Gruber L,Jaschke WR

    更新日期:2017-05-01 00:00:00

  • New tools of the trade.

    abstract::The author reviews the regulatory process through which new cardiovascular interventional devices reach the hands of the interventional radiologist and the cardiologist. The marketing mechanisms are outlined, as are the data requirements. The reader is taken step-by-step from device investigation conducted under an ap...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章

    doi:10.1148/radiology.174.3.174-3-923

    authors: Reamer LA

    更新日期:1990-03-01 00:00:00

  • Up to 50-fold increase in urine viscosity with iso-osmolar contrast media in the rat.

    abstract:PURPOSE:To compare changes in urinary viscosity in the renal tubules following administration of a high-viscosity iso-osmolar contrast agent (iodixanol) to that observed following administration of a less viscous, higher osmolar contrast agent (iopromide) in anesthetized rats. MATERIALS AND METHODS:A total of 43 rats ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.10091485

    authors: Seeliger E,Becker K,Ladwig M,Wronski T,Persson PB,Flemming B

    更新日期:2010-08-01 00:00:00

  • The Diagnostic Performance of Dynamic Contrast-enhanced MR Imaging for Detection of Small Hepatocellular Carcinoma Measuring Up to 2 cm: A Meta-Analysis.

    abstract:PURPOSE:To determine the performance of dynamic contrast material-enhanced magnetic resonance (MR) imaging in the diagnosis of small (≤2-cm) hepatocellular carcinoma (HCC) and to identify factors that influence this performance. MATERIALS AND METHODS:Medline and Embase databases were searched for studies performed fro...

    journal_title:Radiology

    pub_type: 杂志文章,meta分析

    doi:10.1148/radiol.2015150177

    authors: Kierans AS,Kang SK,Rosenkrantz AB

    更新日期:2016-01-01 00:00:00

  • Whole-body PET/CT scanning: estimation of radiation dose and cancer risk.

    abstract:PURPOSE:To estimate the radiation dose from whole-body fluorine 18 ((18)F)-fluorodeoxyglucose (FDG) positron emission tomographic (PET)/computed tomographic (CT) studies and to evaluate the induced cancer risk to U.S. and Hong Kong populations. MATERIALS AND METHODS:Fluorine 18-FDG PET/CT studies obtained by using a 6...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2511081300

    authors: Huang B,Law MW,Khong PL

    更新日期:2009-04-01 00:00:00

  • Pheochromocytoma and the normal adrenal medulla: improved visualization with I-123 MIBG scintigraphy.

    abstract::The radiopharmaceutical iodine 131 metaiodobenzylguanidine (I-131 MIBG) has been shown to locate pheochromocytomas scintigraphically with a false-negative rate of approximately 13%. To improve image quality and reduce the false-negative rate, I-123 was examined as a radioactive label for MIBG, as it has many advantage...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.155.3.4001380

    authors: Lynn MD,Shapiro B,Sisson JC,Beierwaltes WH,Meyers LJ,Ackerman R,Mangner TJ

    更新日期:1985-06-01 00:00:00

  • Hemochromatosis of the pituitary gland: MR imaging.

    abstract::Magnetic resonance imaging of the pituitary gland in a patient with secondary hemochromatosis is described. On T1-weighted images, the anterior lobe had almost no signal intensity, and only the high-signal posterior lobe was seen. These findings are compatible with the distribution of iron deposition and clinical symp...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.168.1.3380960

    authors: Fujisawa I,Morikawa M,Nakano Y,Konishi J

    更新日期:1988-07-01 00:00:00

  • Case 282: Fishbone Pylephlebitis.

    abstract::HistoryA 63-year-old woman with a history of left mastectomy for breast cancer and partial gastrectomy with Roux-en-Y reconstruction for nonhealing peptic ulcer presented to the emergency department and reported a 1-month history of abdominal distention, fevers, chills, and flu-like symptoms. She was initially suspect...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2020190436

    authors: Davarpanah AH,Eberhardt LW

    更新日期:2020-10-01 00:00:00

  • Focal Nodular Hyperplasia and Hepatocellular Adenoma: Accuracy of Gadoxetic Acid-enhanced MR Imaging--A Systematic Review.

    abstract:PURPOSE:To perform a systematic review to evaluate the diagnostic accuracy of hepatobiliary (HPB) phase gadoxetic acid-enhanced MR imaging of the liver in the diagnosis of focal nodular hyperplasia (FNH) versus hepatocellular adenoma (HCA) and to identify the rate of (a) reported HCAs that are iso- or hyperintense to l...

    journal_title:Radiology

    pub_type: 杂志文章,评审

    doi:10.1148/radiol.2015142986

    authors: McInnes MD,Hibbert RM,Inácio JR,Schieda N

    更新日期:2015-11-01 00:00:00

  • Diffuse pulmonary hemangiomatosis.

    abstract::The authors describe three pediatric patients with diffuse pulmonary hemangiomatosis. Virtually identical clinical, radiographic, and pathologic findings were observed in each case. The combination of diffuse interstitial pulmonary infiltration and bloody pleural effusion in a child is pathognomonic. Early recognition...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/127.2.445

    authors: Rowen M,Thompson JR,Williamson RA,Wood BJ

    更新日期:1978-05-01 00:00:00

  • Irreversible JPEG compression of digital chest radiographs for primary interpretation: assessment of visually lossless threshold.

    abstract:PURPOSE:To determine if digital chest images could be compressed in a primary interpretation context without perceived loss of fidelity (below the visually lossless threshold) at transilluminated film or cathode ray tube (CRT) display. MATERIALS AND METHODS:One hundred forty-four posteroanterior radiographs were obtai...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2282011998

    authors: Slone RM,Muka E,Pilgram TK

    更新日期:2003-08-01 00:00:00

  • Acute cholecystitis at T2-weighted and manganese-enhanced T1-weighted MR cholangiography: preliminary study.

    abstract::Twelve patients with symptoms of acute cholecystitis underwent heavily T2-weighted and mangafodipir trisodium-enhanced T1-weighted magnetic resonance (MR) cholangiography and cholescintigraphy before they underwent cholecystectomy. On T2-weighted MR cholangiographic images, morphologic evidence of outflow obstruction ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2272020207

    authors: Kim KW,Park MS,Yu JS,Chung JP,Ryu YH,Lee SI,Lee KS,Yoon SW,Lee KH

    更新日期:2003-05-01 00:00:00

  • The Effect of Modality and Landmark Selection on MRI and CT Femoral Torsion Angles.

    abstract::Background Assessment of femoral torsion at preoperative hip imaging is commonly recommended. However, it is unclear whether MRI is as accurate as CT and how different methods affect femoral torsion measurements. Purpose To compare MRI- and CT-based assessment of femoral torsion by using four commonly used measurement...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2020192723

    authors: Schmaranzer F,Kallini JR,Miller PE,Kim YJ,Bixby SD,Novais EN

    更新日期:2020-08-01 00:00:00

  • Introducing the "golden oldies" of radiology.

    abstract::Online supplemental material is available for this article. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.14142264

    authors: Kressel HY,Levine D

    更新日期:2015-01-01 00:00:00

  • Suspected pulmonary embolism: enhancement of pulmonary arteries at deep-inspiration CT angiography--influence of patent foramen ovale and atrial-septal defect.

    abstract:PURPOSE:To investigate if abnormal early contrast enhancement of the aorta and decreased attenuation of pulmonary arteries at deep-inspiration spiral computed tomographic (CT) angiography might be caused by a patent foramen ovale (PFO). MATERIALS AND METHODS:Two hundred forty-four spiral CT angiographic images of the ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2263012200

    authors: Henk CB,Grampp S,Linnau KF,Thurnher MM,Czerny C,Herold CJ,Mostbeck GH

    更新日期:2003-03-01 00:00:00

  • Computed tomography in the evaluation of musculoskeletal neoplasms.

    abstract::In a study of 62 musculoskeletal neoplasms, computed tomography contributed little to establishing tissue diagnosis. Its primary value lay in the assessment of intraosseous and/or extraosseous extent of disease. CT also established the presence or absence of disease in a small number of cases with clinically questiona...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/128.1.89

    authors: deSantos LA,Goldstein HM,Murray JA,Wallace S

    更新日期:1978-07-01 00:00:00

  • Automatic quantitative left ventricular analysis of cine MR images by using three-dimensional information for contour detection.

    abstract::The purpose of this study was to evaluate an automatic boundary detection algorithm of the left ventricle on magnetic resonance (MR) short-axis images with the essential restriction of no manual corrections. The study comprised 13 patients (nine men, four women) and 12 healthy volunteers (11 men, one woman), and insti...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2401050471

    authors: van Geuns RJ,Baks T,Gronenschild EH,Aben JP,Wielopolski PA,Cademartiri F,de Feyter PJ

    更新日期:2006-07-01 00:00:00

  • Myocardial fat deposition after left ventricular myocardial infarction: assessment by using MR water-fat separation imaging.

    abstract:PURPOSE:To prospectively investigate the prevalence of fat deposition in chronic myocardial infarction (MI) by using magnetic resonance (MR) fat-water separation imaging with sampling of the entire left ventricular (LV) myocardium. A subsidiary aim was to determine the relationship between LV fat deposition and scar ch...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2532082290

    authors: Goldfarb JW,Roth M,Han J

    更新日期:2009-10-01 00:00:00

  • Magnetic resonance without nuclear.

    abstract::The American College of Radiology's Commission on Nuclear Magnetic Resonance has recommended adoption of the term "Magnetic Resonance" as a replacement. The author offers background and rationale for this shift in terminology. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.150.1.6689780

    authors: Meaney TF

    更新日期:1984-01-01 00:00:00

  • Brain tumor resection: intraoperative monitoring with high-field-strength MR imaging-initial results.

    abstract:PURPOSE:To investigate the challenges and benefits of magnetic resonance (MR) imaging during brain tumor resection. MATERIALS AND METHODS:A short-bore 1.5-T MR system equipped with echo-planar-capable gradients was used in resection of brain tumors in 30 patients. MR sequences and need for contrast material enhancemen...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.215.1.r00ap31221

    authors: Martin AJ,Hall WA,Liu H,Pozza CH,Michel E,Casey SO,Maxwell RE,Truwit CL

    更新日期:2000-04-01 00:00:00

  • Pelvimetry by digital radiography: a low-dose examination.

    abstract::Digital radiographs obtained with a CT scanner were evaluated as an alternative to conventional pelvimetry. Dosimetry studies demonstrated an absorbed radiation dose of 22 mrad for each digital radiograph, approximately 3% of the dose for comparable standard radiographs. Distance measurements were accurately made on d...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.143.3.7079500

    authors: Federle MP,Cohen HA,Rosenwein MF,Brant-Zawadzki MN,Cann CE

    更新日期:1982-06-01 00:00:00

  • Dysplastic nodules in liver cirrhosis: evaluation of hemodynamics with CT during arterial portography and CT hepatic arteriography.

    abstract:PURPOSE:To evaluate the portal and arterial blood supplies to dysplastic nodules in the cirrhotic liver with computed tomography (CT) during arterial portography (CTAP) and CT hepatic arteriography (CTHA). MATERIALS AND METHODS:Nineteen histopathologically proved low-grade dysplastic nodules and 13 high-grade dysplast...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.214.3.r00mr12869

    authors: Lim JH,Cho JM,Kim EY,Park CK

    更新日期:2000-03-01 00:00:00

  • Finger arthrography.

    abstract::The use of arthrography in patients with chronic finger complaints is discussed. Magnification arthrography was performed to assist the clinical evaluation of 15 patients with pain in the metacarpal-phalangeal or proximal interphalangeal joints. Conditions detected include collateral ligament laxity, extravasation aro...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.137.3.7444050

    authors: Rosenthal D,Murray WT,Smith RJ

    更新日期:1980-12-01 00:00:00

  • Subclinical carotid atherosclerosis: short-term natural history of lipid-rich necrotic core--a multicenter study with MR imaging.

    abstract:PURPOSE:To use magnetic resonance (MR) imaging to examine the short-term (6 months) natural history of the lipid-rich necrotic core (LRNC) in carotid artery plaques by examining the placebo group of a multicenter clinical trial. MATERIALS AND METHODS:Study procedures and consent forms were approved by the institutiona...

    journal_title:Radiology

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1148/radiol.13121702

    authors: Sun J,Balu N,Hippe DS,Xue Y,Dong L,Zhao X,Li F,Xu D,Hatsukami TS,Yuan C

    更新日期:2013-07-01 00:00:00

  • The year 2000 threat: preparing radiology for nine realms of risk.

    abstract::The year 2000 computer problem arises from a long-standing and often-duplicated computer programming error. Affected programs use only two digits to represent years, which may lead to a variety of computer malfunctions and data errors related to crossing from 1999 (99) to 2000 (00), at which point computers may interp...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.210.1.r99ja4417

    authors: Berland LL

    更新日期:1999-01-01 00:00:00

  • Defining the normal temporomandibular joint: closed-, partially open-, and open-mouth MR imaging of asymptomatic subjects.

    abstract::Fifty temporomandibular joints (TMJs) in 30 asymptomatic volunteers were imaged with a 1.5-T magnetic resonance (MR) imaging system to determine (a) the normal range of meniscus position, (b) the best definition of a normal TMJ and criteria to distinguish it from a TMJ with significant internal derangements, (c) the s...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.177.1.2399340

    authors: Drace JE,Enzmann DR

    更新日期:1990-10-01 00:00:00

  • Screening for lung cancer in a fixed population by biennial chest radiography.

    abstract::All screening radiographs of the chest and other medical records of 107 patients with histologically proved lung cancer in a fixed population were reviewed to assess the efficacy of biennial chest radiography in detecting lung cancer. Radiographic abnormalities caused by tumors were initially detected in 58 patients (...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.148.2.6306720

    authors: Hayabuchi N,Russell WJ,Murakami J,Nishitani H

    更新日期:1983-08-01 00:00:00