Head and pelvis stride-to-stride oscillations in gait: validation and interpretation of measurements from wearable accelerometers.

Abstract:

:Unstable gait is a risk factor for falls. Wearable accelerometers enable remote monitoring of daily walking. Here, new methods for measuring stride-to-stride oscillations are validated against optical motion capture, normative data determined, and dependency on walking speed investigated. Walks by 13 young people (mean age 32 years) at fast, usual, and slow speeds were completed. Accelerometers were attached to the head and pelvis and stride-to-stride oscillation velocity and displacement were measured. Continuous tilt corrections were applied, filter cut-offs scaled by step frequency, and thresholds optimized using optical motion capture as a reference. Oscillations depended on walking speed, accelerometer placement, and measurement axis. Vertical oscillations increased with walking speed (Pearson's r = 0.78-0.89) and were the most accurate (1.4-2.3% error). Mediolateral or anterioposterior oscillations were less accurate (5.9-19.5% error) and had more complex relationships with walking speed (increasing, decreasing, uncorrelated, and/or 'U-shaped' minimum at usual speed). In healthy gait, the head and pelvis undergo regular oscillations, measurable with accelerometers. The results suggest head oscillations in the transverse plane are attenuated by the trunk, and there may be advantages in minimizing stride-to-stride oscillations that coincide with self-selected usual pace. These methods may prove useful for remote assessment of changing health, mental status, and/or fall risk.

journal_name

Physiol Meas

authors

Brodie MA,Beijer TR,Canning CG,Lord SR

doi

10.1088/0967-3334/36/5/857

subject

Has Abstract

pub_date

2015-05-01 00:00:00

pages

857-72

issue

5

eissn

0967-3334

issn

1361-6579

journal_volume

36

pub_type

杂志文章
  • Differences in the microcirculatory effects of local skin surface contact pressure stimulation between acupoints and nonacupoints: possible relevance to acupressure.

    abstract::In the present study, laser Doppler measurement was used to quantitatively investigate the microcirculatory effects of contact pressure stimulation (PS) underneath the Hoku acupoint and its nearby nonacupoint, to improve the understanding of the mechanisms underlying acupressure therapy. A control group (no PS applied...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/31/6/007

    authors: Hsiu H,Hsu WC,Chen BH,Hsu CL

    更新日期:2010-06-01 00:00:00

  • The non-invasive and continuous estimation of cardiac output using a photoplethysmogram and electrocardiogram during incremental exercise.

    abstract::Cardiac output (CO) monitoring is not only essential for critically ill patients in the hospital, but also for patients at home and those undergoing cardiopulmonary exercise testing. However, CO is difficult to monitor during daily activities and exercise. In this paper, we aim at developing a novel CO estimation meth...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/31/5/008

    authors: Wang L,Poon CC,Zhang YT

    更新日期:2010-05-01 00:00:00

  • A planar elliptical model of cardio-vagal hysteresis.

    abstract::The state-dependent portion of cardio-vagal baroreflex control is called baroreflex hyteresis: we observe hysteresis when RR interval and carotid diameter depend on both the direction and value of arterial pressure. The elasticity of arterial walls, as well as the responsiveness of central command reset controls the r...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/6/009

    authors: Ler AS,Cohen MA,Taylor JA

    更新日期:2010-06-01 00:00:00

  • A comparison of methods for estimating left ventricular volumes from radionuclide ventriculography.

    abstract::An accurate reproducible measurement of left ventricular volume is important in the evaluation of cardiac disease. Four methods of left ventricular volume measurement by radionuclide ventriculography have been compared and their reproducibility assessed in a patient group. The methods studied were a geometric method, ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/14/1/004

    authors: Thorley PJ,Sheard KL,Rees MR

    更新日期:1993-02-01 00:00:00

  • Assessing the validity and reliability and determining cut-points of the Actiwatch 2 in measuring physical activity.

    abstract:OBJECTIVE:The Actiwatch 2 (AW2) is a wrist-worn accelerometer typically used to measure sleep. Although it can measure physical activity, there is limited evidence supporting its validity. We assessed the validity and reliability of the AW2 to measure sedentary behavior and physical activity (light, moderate, vigorous ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aba80f

    authors: Kemp C,Pienaar PR,Henst RHP,Roden LC,Kolbe-Alexander TL,Rae DE

    更新日期:2020-09-04 00:00:00

  • Reference intervals for the evoked tympanic membrane displacement measurement: a non-invasive measure of intracranial pressure.

    abstract:OBJECTIVE:Evoked tympanic membrane displacement (TMD) is a non-invasive technique for assessing intracranial pressure (ICP). The aim of this study was to define reference intervals (RIs) in the healthy population. APPROACH:Measurements were made in 154 healthy adults. Results were quantified by V m, which is the most ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aaa1d3

    authors: Campbell-Bell CM,Birch AA,Vignali D,Bulters D,Marchbanks RJ

    更新日期:2018-01-31 00:00:00

  • In vivo neutron activation analysis of bone manganese in workers.

    abstract:OBJECTIVE:Manganese (Mn) is a neurotoxin. However, the impact of elevated, chronic Mn exposure is not well understood, partially due to the lack of a cumulative exposure biomarker. To address this gap, our group developed a compact in vivo neutron activation analysis (IVNAA) system to quantify Mn concentration in bone ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aaa749

    authors: Liu Y,Rolle-McFarland D,Mostafaei F,Zhou Y,Li Y,Zheng W,Wells E,Nie LH

    更新日期:2018-03-23 00:00:00

  • Reproducibility of regional lung ventilation distribution determined by electrical impedance tomography during mechanical ventilation.

    abstract::Electrical impedance tomography (EIT) has the potential to become a new tool for bedside monitoring of regional lung ventilation. The aim of our study was to assess the reproducibility of regional lung ventilation distribution determined by EIT during mechanical ventilation under identical ventilator settings. The exp...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/7/S19

    authors: Frerichs I,Schmitz G,Pulletz S,Schädler D,Zick G,Scholz J,Weiler N

    更新日期:2007-07-01 00:00:00

  • Exposure to light and darkness and its influence on physiological measures of intensive care unit patients-a systematic literature review.

    abstract::Sleep-wake patterns are often significantly disturbed in critically ill patients. This disturbance is closely linked to secondary brain dysfunctions in these patients. Sedation not only impairs sleep quality in ICU patients but also has detrimental effects on short- and long-term outcome. In other contexts, light ther...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/0967-3334/37/9/R73

    authors: Weiss B,Spies C,Piazena H,Penzel T,Fietze I,Luetz A

    更新日期:2016-09-01 00:00:00

  • The physiological impact of the nonlinearity of arterial elasticity in the ambulatory arterial stiffness index.

    abstract::The ambulatory arterial stiffness index (AASI) is claimed to be a new estimator for arterial rigidity. It was recently defined as one minus the slope of the linear regression of systolic to diastolic ambulatory pressure during 24 h. Although several reports testify its clinical relevance, the explanation of how this n...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/7/012

    authors: Craiem D,Graf S,Salvucci F,Chironi G,Megnien JL,Simon A,Armentano RL

    更新日期:2010-07-01 00:00:00

  • Eye-tracker algorithms to detect saccades during static and dynamic tasks: a structured review.

    abstract:OBJECTIVE:Eye-tracking devices have become widely used as clinical assessment tools in a variety of applied-scientific fields to measure saccadic eye movements. With the emergence of multiple static and dynamic devices, the concurrent need for algorithm development and validation is paramount. APPROACH:This review ass...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/1361-6579/ab02ab

    authors: Stuart S,Hickey A,Vitorio R,Welman K,Foo S,Keen D,Godfrey A

    更新日期:2019-02-26 00:00:00

  • Measuring dissimilarity between respiratory effort signals based on uniform scaling for sleep staging.

    abstract::Polysomnography (PSG) has been extensively studied for sleep staging, where sleep stages are usually classified as wake, rapid-eye-movement (REM) sleep, or non-REM (NREM) sleep (including light and deep sleep). Respiratory information has been proven to correlate with autonomic nervous activity that is related to slee...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/12/2529

    authors: Long X,Yang J,Weysen T,Haakma R,Foussier J,Fonseca P,Aarts RM

    更新日期:2014-12-01 00:00:00

  • Effects of CO2 on dynamic cerebral autoregulation measurement.

    abstract::Arterial pCO2 is known to influence cerebral autoregulation but its effect on the dynamic relationship between mean arterial blood pressure (ABP) and mean cerebral blood flow velocity (CBFV), obtained from spontaneous fluctuations in ABP, has not been established. In 16 normal subjects, ABP was measured non-invasively...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/20/3/304

    authors: Panerai RB,Deverson ST,Mahony P,Hayes P,Evans DH

    更新日期:1999-08-01 00:00:00

  • Real-time chest-wall-motion tracking by a single optical fibre grating: a prospective method for ventilator triggering.

    abstract:OBJECTIVE:The ventilators involved in non-invasive mechanical ventilation commonly provide ventilator support via a facemask. The interface of the mask with a patient promotes air leaks that cause errors in the feedback information provided by a pneumatic sensor and hence patient-ventilator asynchrony with multiple neg...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aab7ac

    authors: Ivanović MD,Petrovic J,Savić A,Gligorić G,Miletić M,Vukčević M,Bojović B,Hadžievski L,Allsop T,Webb DJ

    更新日期:2018-04-26 00:00:00

  • The linearity and reliability of the mechanomyographic amplitude versus submaximal isometric force relationship.

    abstract::The purpose of this study was to investigate the linearity and reliability of the mechanomyographic (MMG) amplitude versus submaximal isometric force relationship for the vastus lateralis. Twenty healthy subjects (mean +/- SD age = 24.0 +/- 4.3 years) volunteered to perform submaximal isometric muscle actions of the d...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/30/10/002

    authors: Beck TW,DeFreitas JM,Stock MS

    更新日期:2009-10-01 00:00:00

  • Non-contact video-based vital sign monitoring using ambient light and auto-regressive models.

    abstract::Remote sensing of the reflectance photoplethysmogram using a video camera typically positioned 1 m away from the patient's face is a promising method for monitoring the vital signs of patients without attaching any electrodes or sensors to them. Most of the papers in the literature on non-contact vital sign monitoring...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/5/807

    authors: Tarassenko L,Villarroel M,Guazzi A,Jorge J,Clifton DA,Pugh C

    更新日期:2014-05-01 00:00:00

  • Static conductivity imaging using variational gradient Bz algorithm in magnetic resonance electrical impedance tomography.

    abstract::A new image reconstruction algorithm is proposed to visualize static conductivity images of a subject in magnetic resonance electrical impedance tomography (MREIT). Injecting electrical current into the subject through surface electrodes, we can measure the induced internal magnetic flux density B = (Bx, By, Bz) using...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/1/030

    authors: Park C,Park EJ,Woo EJ,Kwon O,Seo JK

    更新日期:2004-02-01 00:00:00

  • Electroencephalogram classification in motor-imagery brain-computer interface applications based on double-constraint nonnegative matrix factorization.

    abstract:OBJECTIVE:Brain-computer interfaces (BCIs) are aimed at providing a new way of communication between the human brain and external devices. One of the major tasks associated with the BCI system is to improve classification performance of the motor imagery (MI) signal. Electroencephalogram (EEG) signals are widely used f...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aba07b

    authors: Su J,Yang Z,Yan W,Sun W

    更新日期:2020-08-11 00:00:00

  • A medical thermal imaging device for the prevention of diabetic foot ulceration.

    abstract::In this paper a description is given of the development, characterisation and first results of a thermal imaging device aimed at significantly reducing the incidence of diabetic foot ulceration (DFU). These devices will be used in three clinical centres and in two preliminary clinical trials. The first will be on heal...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aa56b1

    authors: Machin G,Whittam A,Ainarkar S,Allen J,Bevans J,Edmonds M,Kluwe B,Macdonald A,Petrova N,Plassmann P,Ring F,Rogers L,Simpson R

    更新日期:2017-03-01 00:00:00

  • Specific heat capacity of freshly excised prostate specimens.

    abstract::The specific heat capacity of tissue is a critical parameter for thermal therapies that act over a long period of time. It is also critical for thermoacoustic signal generation. We present ex vivo measurements of specific heat capacity performed by a dual-pin probe with tight temperature control of the specimen. One 3...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/11/N02

    authors: Patch SK,Rao N,Kelly H,Jacobsohn K,See WA

    更新日期:2011-11-01 00:00:00

  • Linear and nonlinear characteristics of heart rate time series in obesity and during weight-reduction surgery.

    abstract::Obesity is associated with abnormal cardiac regulation by the autonomic nervous system (ANS), this being reversed by weight loss. Bariatric (weight-reduction) surgery can induce substantial long-term weight reductions. This study compares the acute influence on ANS control of two different types of bariatric surgery i...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/30/7/002

    authors: Alam I,Lewis MJ,Morgan J,Baxter J

    更新日期:2009-07-01 00:00:00

  • Estimating carotid pulse and breathing rate from near-infrared video of the neck.

    abstract:OBJECTIVE:Non-contact physiological measurement is a growing research area that allows capturing vital signs such as heart rate (HR) and breathing rate (BR) comfortably and unobtrusively with remote devices. However, most of the approaches work only in bright environments in which subtle photoplethysmographic and balli...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aae625

    authors: Chen W,Hernandez J,Picard RW

    更新日期:2018-10-30 00:00:00

  • Cardio-respiratory signal extraction from video camera data for continuous non-contact vital sign monitoring using deep learning.

    abstract::Non-contact vital sign monitoring enables the estimation of vital signs, such as heart rate, respiratory rate and oxygen saturation (SpO2), by measuring subtle color changes on the skin surface using a video camera. For patients in a hospital ward, the main challenges in the development of continuous and robust non-co...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab525c

    authors: Chaichulee S,Villarroel M,Jorge J,Arteta C,McCormick K,Zisserman A,Tarassenko L

    更新日期:2019-12-02 00:00:00

  • Repeatability of body sway measurements; day-to-day variation measured by sway magnetometry.

    abstract::The postural stability of 30 normal subjects in the age range 15 to 64 years was measured on five separate occasions, using the sway magnetometry technique, to determine the day-to-day repeatability of this measurement technique. On each occasion the pathlength and area enclosed by movement of the hips in a horizontal...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/19/2/003

    authors: Elliott C,Murray A

    更新日期:1998-05-01 00:00:00

  • Dynamics of tissue shrinkage during ablative temperature exposures.

    abstract::There is a lack of studies that examine the dynamics of heat-induced shrinkage of organ tissues. Clinical procedures such as radiofrequency ablation, microwave ablation or high-intensity focused ultrasound, use heat to treat diseases such as cancer and cardiac arrhythmia. When heat is applied to tissues, shrinkage occ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/1/55

    authors: Rossmann C,Garrett-Mayer E,Rattay F,Haemmerich D

    更新日期:2014-01-01 00:00:00

  • Carotid flow rates and flow division at the bifurcation in healthy volunteers.

    abstract::In nine healthy subjects, magnetic resonance imaging was used to measure blood flow waveforms in the common (CCA), internal (ICA) and external (ECA) carotid arteries. Useful data were acquired from 14 carotid arteries in total. Flow rates were determined from regions of interest placed over the arteries in CINE-phase ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/25/3/009

    authors: Marshall I,Papathanasopoulou P,Wartolowska K

    更新日期:2004-06-01 00:00:00

  • A randomized controlled trial studying the effect of maternal hyperoxygenation on fetal heart rate in suspected fetal distress.

    abstract:OBJECTIVE:To investigate the effect of maternal hyperoxygenation on fetal heart rate (FHR) when applied for suspected fetal distress during the second stage of term labor. APPROACH:A single-center randomized controlled trial was conducted in a tertiary care hospital in The Netherlands. Participants were included durin...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/abc0b6

    authors: Moors S,Joshi R,Bullens LM,van Oostrum NHM,Regis M,van den Heuvel ER,Oei SG,van Laar JOEH,van der Hout-van der Jagt MB

    更新日期:2020-12-11 00:00:00

  • Video-based respiration monitoring with automatic region of interest detection.

    abstract::Vital signs monitoring is ubiquitous in clinical environments and emerging in home-based healthcare applications. Still, since current monitoring methods require uncomfortable sensors, respiration rate remains the least measured vital sign. In this paper, we propose a video-based respiration monitoring method that aut...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/1/100

    authors: Janssen R,Wang W,Moço A,de Haan G

    更新日期:2016-01-01 00:00:00

  • Pilot acute study of feedback-controlled retrograde peristalsis invoked by neural gastric electrical stimulation.

    abstract::Neural gastric electrical stimulation (NGES) is a new method for invoking gastric contractions under microprocessor control. However, optimization of this technique using feedback mechanisms to minimize power consumption and maximize effectiveness has been lacking. The present pilot study proposes a prototype feedback...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/30/3/006

    authors: Aelen P,Jurkov A,Aulanier A,Mintchev MP

    更新日期:2009-03-01 00:00:00

  • Assessment of hepatic fatty infiltration using dual-energy computed tomography: a phantom study.

    abstract::The purpose of this study was to examine the performance of dual-energy computed tomography (DECT) for the quantification of liver fat content (LFC). We prepared two phantoms: homogenized mixtures of porcine liver and fat and homogeneous mixtures of liver- and fat-equivalent solutions. Tubes containing mixtures with k...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/4/597

    authors: Li JH,Tsai CY,Huang HM

    更新日期:2014-04-01 00:00:00