Center error reduction by recheck of blood type.

Abstract:

:Our computer system currently stores donor blood types for seven years and checks typing of all repeat donors against these files. In a recent three-month period (42,500 units), five discrepancies were found--two representing current error. Retrospective analysis of 18 errors made over the last three years showed that 11, or 58 per cent would have been caught by this system. Eight of these latter errors were in Du-typing, and three were ABO errors. These errors lead to patient problems only if the receiving hospital releases the blood in an emergency without retesting. Even were this to happen, significant untoward reactions would be infrequent. The costs of error reduction must be carefully examined. Systems to reduce errors further may be warranted only if hospitals are not longer required to retest blood.

journal_name

Transfusion

journal_title

Transfusion

authors

Grindon AJ,Liles BA

doi

10.1046/j.1537-2995.1981.21281178157.x

subject

Has Abstract

pub_date

1981-03-01 00:00:00

pages

199-202

issue

2

eissn

0041-1132

issn

1537-2995

journal_volume

21

pub_type

杂志文章
  • Iron supplementation by blood donors: demographics, patterns of use, and motivation.

    abstract:BACKGROUND:Iron supplements reduce the risk of iron depletion in blood donors. Recent initiatives have sought to increase use of donor iron supplementation (IS), but a baseline description of blood donor supplement practices is needed. STUDY DESIGN AND METHODS:Presenting blood donors received a questionnaire inquiring...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/trf.15407

    authors: Cable RG,Spencer BR

    更新日期:2019-09-01 00:00:00

  • Frozen preoperative autologous blood donation for heart transplantation at the Mayo Clinic from 1988 to 1999.

    abstract:BACKGROUND:Preoperative autologous blood donation (PABD) has been used to reduce the need for allogeneic RBC transfusion, decreasing risk and conserving supply. A frozen PABD program for heart transplant patients was instituted at the Mayo Clinic in 1988, but participation has steadily declined. The aims of this study ...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.2003.00357.x

    authors: Fontaine MJ,Winters JL,Moore SB,McGregor CG,Santrach PJ

    更新日期:2003-04-01 00:00:00

  • Zinc protoporphyrin levels have added value in the prediction of low hemoglobin deferral in whole blood donors.

    abstract:BACKGROUND:Increased zinc protoporphyrin (ZPP) levels can indicate iron deficiency and may be predictive for low hemoglobin (Hb) deferral in blood donors. Prediction models for Hb deferral in whole blood donors have already been developed. In this study, we examined if addition of ZPP to these prediction models improve...

    journal_title:Transfusion

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1537-2995.2012.03957.x

    authors: Baart AM,de Kort WL,Moons KG,Atsma F,Vergouwe Y

    更新日期:2013-08-01 00:00:00

  • Estimated risk of Chikungunya viremic blood donation during an epidemic on Reunion Island in the Indian Ocean, 2005 to 2007.

    abstract:BACKGROUND:Between 2005 and 2007, Chikungunya virus (CHIKV) caused a massive epidemic on Reunion Island with a major peak in the number of cases in February 2006. Blood donation was interrupted on the island in January 2006. STUDY DESIGN AND METHODS:Estimates of the mean risk of viremic blood donation on Reunion Islan...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/j.1537-2995.2008.01646.x

    authors: Brouard C,Bernillon P,Quatresous I,Pillonel J,Assal A,De Valk H,Desenclos JC,workgroup \Quantitative Estimation of the Risk of Blood Donation Contamination by Infectious Agents\.

    更新日期:2008-07-01 00:00:00

  • Significance of the signal-to-cutoff ratios of anti-hepatitis C virus enzyme immunoassays in screening of Chinese blood donors.

    abstract:BACKGROUND:The correlation between signal-to-cutoff (S/CO) ratios of a second-generation hepatitis C virus (HCV) enzyme immunoassay (EIA; Abbott) and a third-generation HCV enzyme-linked immunosorbent assay (ELISA; Ortho) and confirmed HCV infection has been reported. The utility of the values for the Chinese anti-HCV ...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/j.1537-2995.2005.00611.x

    authors: Ren FR,Lv QS,Zhuang H,Li JJ,Gong XY,Gao GJ,Liu CL,Wang JX,Yao FZ,Zheng YR,Zhu FM,Tiemuer MH,Bai XH,Shan H

    更新日期:2005-11-01 00:00:00

  • Flow cytometric studies of the D antigen of various Rh phenotypes with particular reference to Du and Del.

    abstract::Flow cytometric analysis was performed on red cells (RBCs) to compare the antigen activity of various Rh phenotypes, including the rare variants Del and Du (both high-grade and low-grade), whose genotypes were confirmed or presumed by the family study. This appears to be the first report that the Del phenotype is due ...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1990.30390194344.x

    authors: Hasekura H,Ota M,Ito S,Hasegawa Y,Ichinose A,Fukushima H,Ogata H

    更新日期:1990-03-01 00:00:00

  • A whole genome approach for discovering the genetic basis of blood group antigens: independent confirmation for P1 and Xga.

    abstract:BACKGROUND:Although P1 and Xga are known to be associated with the A4GALT and XG genes, respectively, the genetic basis of antigen expression has been elusive. Recent reports link both P1 and Xga expression with nucleotide changes in the promotor regions and with antigen-negative phenotypes due to disruption of transcr...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/trf.15089

    authors: Lane WJ,Aguad M,Smeland-Wagman R,Vege S,Mah HH,Joseph A,Blout CL,Nguyen TT,Lebo MS,Sidhu M,Lomas-Francis C,Kaufman RM,Green RC,Westhoff CM,MedSeq Project.

    更新日期:2019-03-01 00:00:00

  • A comparison of two behavioral influence techniques for improving blood donor recruitment.

    abstract::This study was designed to test the viability of two multiple request techniques of behavioral influence for recruiting blood donors by telephone. The first technique utilizes a small antecedent request to encourage behavioral involvement and favorable disposition toward the target activity of the critical request to ...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1984.24585017828.x

    authors: Hayes TJ,Dwyer FR,Greenwalt TJ,Coe NA

    更新日期:1984-09-01 00:00:00

  • Coagulation parameters of CPD fresh-frozen plasma and CPD cryoprecipitate-poor plasma after storage at 4 degrees C for 28 days.

    abstract::A pilot study was performed on the storage of plasma and cryosupernatant plasma at 4 degrees C for up to 28 days. Eight bags, four of CPD fresh-frozen plasma (FFP) and four of CPD cryosupernatant plasma (CSP, plasma without cryoprecipitate), were sampled during storage for assays of pH; factors V, VIII, IX, and XI; fi...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1993.33994025023.x

    authors: Smak Gregoor PJ,Harvey MS,Briët E,Brand A

    更新日期:1993-09-01 00:00:00

  • Retroviral transduction of peripheral blood leukocytes in a hollow-fiber bioreactor.

    abstract:BACKGROUND:Peripheral blood white cells (leukocytes) (PBLs) have been used as effective targets for genetic manipulation by transduction with retroviruses in open systems. A semi-closed hollow-fiber bioreactor was tested for culturing and transducing lymphocytes. STUDY DESIGN AND METHODS:PBLs were isolated from five h...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1997.37797369442.x

    authors: Shankar R,Whitley CB,Pan D,Burger S,McCullough J,Stroncek D

    更新日期:1997-07-01 00:00:00

  • Prevention of transfusion-associated Chagas' disease: efficacy of white cell-reduction filters in removing Trypanosoma cruzi from infected blood.

    abstract:BACKGROUND:Transfusion-associated Chagas' disease (TA-CD) is a worldwide problem. Measures adopted to prevent TA-CD include the clinical and serologic screening of blood donors and/or the inactivation of Trypanosoma cruzi present in collected blood, using gentian violet as the trypanocidal agent. This study investigate...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1995.35996029154.x

    authors: Moraes-Souza H,Bordin JO,Bardossy L,MacPherson DW,Blajchman MA

    更新日期:1995-09-01 00:00:00

  • A "new" low-incidence red cell antigen, LOCR, associated with altered expression of Rh antigens.

    abstract:BACKGROUND:Mild cases of hemolytic disease of the newborn were being studied when it was recognized that the propositi's red cells carried a novel antigen. STUDY DESIGN AND METHODS:Serologic and genetic studies of a new low-incidence antigen, LOCR (International Society of Blood Transfusion series number 700.53), were...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1994.34694295063.x

    authors: Coghlan G,McCreary J,Underwood V,Zelinski T

    更新日期:1994-06-01 00:00:00

  • Prospective randomized and crossover comparison of two apheresis machines for peripheral blood stem cell collection: a multicenter study.

    abstract:BACKGROUND:Improving apheresis technology may lead to an efficient and safe peripheral blood stem cell (PBSC) collection. Recently, the Spectra Optia (Optia, Terumo BCT) was introduced as an automated apheresis instrument, but comparisons with other instruments have been few. This is the first randomized multicenter an...

    journal_title:Transfusion

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1111/trf.13777

    authors: Ikeda K,Minakawa K,Muroi K,Fujiwara SI,Yamada-Fujiwara M,Fujimori Y,Tanosaki R,Ohto H,Study Group for Peripheral Blood Stem Cell Collection, Cell Therapy Committee, The Japan Society of Transfusion Medicine and Cell Therapy.

    更新日期:2016-11-01 00:00:00

  • Xenotropic murine leukemia virus-related virus does not pose a risk to blood recipient safety.

    abstract:BACKGROUND:When xenotropic murine leukemia virus-related virus (XMRV) was first reported in association with chronic fatigue syndrome, it was suggested that it might offer a risk to blood safety. Thus, the prevalence of the virus among blood donors and, if present, its transmissibility by transfusion need to be defined...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/j.1537-2995.2011.03450.x

    authors: Dodd RY,Hackett J Jr,Linnen JM,Dorsey K,Wu Y,Zou S,Qiu X,Swanson P,Schochetman G,Gao K,Carrick JM,Krysztof DE,Stramer SL

    更新日期:2012-02-01 00:00:00

  • Factor VIII preservation following collection into commercial plasmapheresis systems.

    abstract::The two-stage method of Pool and Robinson was used in determining plasma Factor VIII activity following contact with four commercially available plastic blood and pooling bag films. Employing a two-arm double plasmapheresis technique, it was shown that Factor VIII activity in whole blood initially drawn into BB-69 and...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1975.15476034563.x

    authors: Mishler JM,Nicora RW,Hamilton JE,Caster G,Kasper CK

    更新日期:1975-07-01 00:00:00

  • Anti-K formation is not associated with the storage time of transfused red blood cells.

    abstract:BACKGROUND:The formation of red blood cell (RBC) antibodies could be enhanced by the presence of inflammation caused by prolonged RBC storage, as was shown in animal studies. The low occurrence (<10%) of K-antigen in most populations often enables identification of the K+ RBC unit that triggered anti-K formation and de...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/trf.12974

    authors: Hogervorst E,Middelburg R,Brand A,van de Watering L,Schonewille H

    更新日期:2015-06-01 00:00:00

  • In vivo red cell destruction by anti-Lu6.

    abstract::An example is presented of an IgG1, anti-Lu6, that reacted by indirect antiglobulin test and was capable of destroying antigen-positive red cells in vivo. Two methods for the measurement of red cell survival, 51Cr labeling and flow cytometry, gave the same result: 20 percent of the test dose of Lu:6 red cells was dest...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1990.30390194349.x

    authors: Issitt PD,Valinsky JE,Marsh WL,DiNapoli J,Gutgsell NS

    更新日期:1990-03-01 00:00:00

  • Effectiveness and cost analysis of "just-in-time" salvage plerixafor administration in autologous transplant patients with poor stem cell mobilization kinetics.

    abstract:BACKGROUND:Plerixafor is a recently Food and Drug Administration (FDA)-approved CXCR4 antagonist, which is combined with granulocyte-colony-stimulating factor (G-CSF) to facilitate stem cell mobilization of lymphoma and myeloma patients. STUDY DESIGN AND METHODS:To evaluate the effectiveness and the related costs of a...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/j.1537-2995.2011.03136.x

    authors: Li J,Hamilton E,Vaughn L,Graiser M,Renfroe H,Lechowicz MJ,Langston A,Prichard JM,Anderson D,Gleason C,Lonial S,Flowers CR,Kaufman JL,Waller EK

    更新日期:2011-10-01 00:00:00

  • Increased risk of volume overload with plasma compared with four-factor prothrombin complex concentrate for urgent vitamin K antagonist reversal.

    abstract:BACKGROUND:Plasma is commonly used for vitamin K antagonist (VKA) reversal, but observational studies suggest that it is associated with transfusion-related adverse reactions (e.g., volume overload). However, this issue has not previously been addressed in a randomized controlled trial (RCT). STUDY DESIGN AND METHODS:...

    journal_title:Transfusion

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/trf.13191

    authors: Refaai MA,Goldstein JN,Lee ML,Durn BL,Milling TJ Jr,Sarode R

    更新日期:2015-11-01 00:00:00

  • Flow cytometric analyses of CD34+ cells with inclusion of internal positive controls.

    abstract:BACKGROUND:Flow cytometric measurement of CD34+ events is used to ensure the quality of human progenitor cell grafts. This study was conducted to evaluate whether the spiking of routine samples from peripheral blood and apheresis products with CD34+ positive controls is feasible. STUDY DESIGN AND METHODS:A total of 42...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/j.1537-2995.2011.03259.x

    authors: Gutensohn K,Jessen M,Ketels A,Gramatzki M,Humpe A

    更新日期:2012-02-01 00:00:00

  • Trend in ABO-incompatible RBC transfusion-related fatalities reported to the FDA, 2000-2019.

    abstract:BACKGROUND:ABO-incompatible red blood cell (RBC) transfusions and acute hemolytic reactions occur infrequently, yet resultant fatalities are reported to the US Food and Drug Administration (FDA) every year. We describe a 20-year retrospective study of reported mistransfusion cases to identify temporal trends, common ca...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/trf.16121

    authors: Storch EK,Rogerson B,Eder AF

    更新日期:2020-12-01 00:00:00

  • Platelet counting in platelet concentrates with various automated hematology analyzers.

    abstract:BACKGROUND:Hematology analyzers use impedance, optical, and/or immunologic techniques for counting platelets (PLTs). PLT counting in whole blood has been validated thoroughly; however, this is not the case for PLT counting in PLT concentrates (PCs), in which red cells (RBCs) are absent. Therefore, this study is focused...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/j.1537-2995.2007.01337.x

    authors: Dijkstra-Tiekstra MJ,Kuipers W,Setroikromo AC,de Wildt-Eggen J

    更新日期:2007-09-01 00:00:00

  • A simplified method for quality control of deglycerolized erythrocytes.

    abstract::Quality control to detect inadequately deglycerolized red blood cells can be easily and inexpensively accomplished by suspending the deglycerolized cells in either recipient serum or normal saline in the same way in which the routine crossmatch is performed. In vitro hemolysis is readily and consistently apparent when...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1982.22382224955.x

    authors: Silver H,Umlas J,Kenney P,Anderson J,Pina B,Cross D

    更新日期:1982-05-01 00:00:00

  • Diclofenac-induced antibodies against RBCs and platelets: two case reports and a concise review.

    abstract:BACKGROUND:Diclofenac has frequently been implicated as the cause of immune hemolytic anemias and less frequently of immune thrombocytopenia. The presence of the causative antibodies has only been demonstrated in patients with immune hemolytic anemia, but not yet in patients with thrombocytopenia. The cases of two pati...

    journal_title:Transfusion

    pub_type: 杂志文章,评审

    doi:10.1046/j.1537-2995.2003.00340.x

    authors: Meyer O,Hoffmann T,Aslan T,Ahrens N,Kiesewetter H,Salama A

    更新日期:2003-03-01 00:00:00

  • Effects of blood storage age on immune, coagulation, and nitric oxide parameters in transfused patients undergoing cardiac surgery.

    abstract:BACKGROUND:Retrospective studies suggested that storage age of RBCs is associated with inflammation and thromboembolism. The Red Cell Storage Duration Study (RECESS) trial randomized subjects undergoing complex cardiac surgery to receive RBCs stored for shorter versus longer periods, and no difference was seen in the p...

    journal_title:Transfusion

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1111/trf.15228

    authors: Spinella PC,Sniecinski RM,Trachtenberg F,Inglis HC,Ranganathan G,Heitman JW,Szlam F,Danesh A,Stone M,Keating SM,Levy JH,Assmann SF,Steiner ME,Doctor A,Norris PJ

    更新日期:2019-04-01 00:00:00

  • Platelet storage. Effects of leachable materials on morphology and function.

    abstract::A polyolefin plastic (PL 732) bag formulated without liquid plasticizer allows storage of platelets for 5 and, now, up to 7 days. In order to assess the leaching of compounds from this new plastic, extracts of the supernatant from platelet concentrates stored in these bags were analyzed by high-performance liquid chro...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1986.26486262743.x

    authors: Labow RS,Tocchi M,Rock G

    更新日期:1986-07-01 00:00:00

  • Detection and identification of platelet antibodies using a sensitive multiplex assay system-platelet antibody bead array.

    abstract:BACKGROUND:Tests for platelet-specific antibodies are important in the diagnosis of immune platelet disorders. Monoclonal antibody glycoprotein capture assays have been the gold standards in platelet antibody detection for almost 30 years. However, such assays are complex and cumbersome to perform, which limits their r...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/trf.14122

    authors: Metzner K,Bauer J,Ponzi H,Ujcich A,Curtis BR

    更新日期:2017-07-01 00:00:00

  • Emm. A red cell antigen of very high frequency.

    abstract::Anti-Emm, an antibody to a public red cell antigen, was found in the serums of four Emm-propositi and in the serum of the Emm-brother of one of them. Three of the propositi were men, and their antibodies, as well as that of the compatible brother, were believed to be "naturally occurring." Since there are two Emm-sibl...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1987.27487264738.x

    authors: Daniels GL,Taliano V,Klein MT,McCreary J

    更新日期:1987-07-01 00:00:00

  • Implementing mass-scale red cell genotyping at a blood center.

    abstract:BACKGROUND:When problems with compatibility beyond ABO and D arise, currently transfusion services search their inventories and perform time-consuming serologic testing to locate antigen-negative blood. These clinically important blood group antigens can be detected reliably by red cell genotyping, which is a technolog...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/trf.13168

    authors: Flegel WA,Gottschall JL,Denomme GA

    更新日期:2015-11-01 00:00:00

  • Development of a quality monitoring program for platelet components: a report of the first four years' experience at Canadian Blood Services.

    abstract:BACKGROUND:A quality monitoring program (QMP) for platelet concentrates (PCs) was implemented at Canadian Blood Services (CBS) to improve standards and to better understand platelet (PLT) products by supplementing routine quality control (QC). STUDY DESIGN AND METHODS:Annual surveys of PCs from CBS production sites we...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/j.1537-2995.2011.03402.x

    authors: Levin E,Jenkins C,Culibrk B,Gyöngyössy-Issa MI,Serrano K,Devine DV

    更新日期:2012-04-01 00:00:00