Long-term clinical and angiographic results of Sirolimus-Eluting Stent in Complex Coronary Chronic Total Occlusion Revascularization: the SECTOR registry.

Abstract:

BACKGROUND:Drug-eluting stents showed a better angiographic and clinical outcome in comparison with bare metal stent in chronic total occlusions (CTOs) percutaneous revascularization, however, great concerns still remain regarding the rate of restenosis and reocclusion in comparison with nonocclusive lesions. AIM:To evaluate angiographic and clinical outcomes after sirolimus-eluting stent (SES) implantation in the setting of a "real world" series of complex CTOs. METHODS AND RESULTS:From January 2006 to December 2008, 172 consecutive patients with 179 CTO lesions were enrolled into registry. Among these, successful recanalization was obtained in 144 lesions (80.4%) with exclusive SES implantation in 104 lesions. The 9-12 months angiographic follow-up was executed in 85.5% of lesions with evidence of angiographic binary restenosis in 16.8% of lesions. Total stent length and number of stent implanted were recognized as independent predictors of restenosis (odds ratio [OR] 4.7, 95% confidence interval [CI] 1.28-107.09, P = 0.02) and (OR 5.8, 95% CI 1.39-23.55, P = 0.01), respectively.The 2-year clinical follow-up showed rates of target lesion revascularization, non-Q wave myocardial infarction, and total major adverse cardiovascular events (MACEs) of 11.1%, 2%, and 13.1%, respectively. Cox proportional-hazard analysis showed diabetes as independent predictor of MACEs (hazard ratio [HR] 4.832; 95% CI, 0.730-0.861; P = 0.028). CONCLUSIONS:Data from this registry demonstrate the long-term efficacy and safety of SES implantation after complex CTOs recanalization.

journal_name

J Interv Cardiol

authors

Galassi AR,Tomasello SD,Costanzo L,Campisano MB,Barrano G,Tamburino C

doi

10.1111/j.1540-8183.2011.00648.x

subject

Has Abstract

pub_date

2011-10-01 00:00:00

pages

426-36

issue

5

eissn

0896-4327

issn

1540-8183

journal_volume

24

pub_type

杂志文章
  • Catheter-based approach to mitral regurgitation.

    abstract::Mitral Regurgitation (MR) is a common medical problem. MR is also a prognostic factor; patients with severe symptomatic MR have a poor prognosis with an annual mortality rate of 5% without surgical intervention. An anatomic understanding of the normal and regurgitant mitral valve is essential in order to evaluate appr...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,评审

    doi:10.1046/j.1540-8183.2003.01052.x

    authors: Condado JA,Vélez-Gimón M

    更新日期:2003-12-01 00:00:00

  • Periprocedural management and in-hospital outcome of patients with indication for oral anticoagulation undergoing coronary artery stenting.

    abstract:PURPOSE:In patients on oral anticoagulation (OAC) undergoing coronary stenting (PCI-S), procedural management and in-hospital outcome have never been specifically and prospectively investigated. Also, the contribution of early bleeding to the relevant hemorrhagic rate reported at follow-up with triple therapy of OAC, a...

    journal_title:Journal of interventional cardiology

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1111/j.1540-8183.2009.00468.x

    authors: Rubboli A,Colletta M,Valencia J,Capecchi A,Franco N,Zanolla L,La Vecchia L,Piovaccari G,Di Pasquale G,WARfarin and Coronary STENTing (WAR-STENT) Study Group.

    更新日期:2009-08-01 00:00:00

  • Long-term safety and effectiveness of drug-eluting stents compared to bare metal stents in ST elevation myocardial infarction: findings from the Guthrie Health Off-label Stent (GHOST) Registry.

    abstract:BACKGROUND:Multiple randomized trials and observational studies have shown drug-eluting stents (DES) to be safe and effective at 3-year follow-up in stent thrombosis (ST)-segment elevation myocardial infarction (STEMI) treated with primary percutaneous coronary intervention (PCI). However, outcomes data beyond 3-4 year...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2011.00703.x

    authors: Sattur S,Orshaw P,Boura J,Harjai KJ

    更新日期:2012-04-01 00:00:00

  • Predictors of recurrent in-stent restenosis after beta-radiation: An analysis from the START 40/20 trial.

    abstract:OBJECTIVE:The purpose of this study was to identify potential predictors, including clinical, procedural, angiographic, and intravascular ultrasound (IVUS) parameters, for recurrent in-stent restenosis (ISR) following beta-radiation 90Strontium/Yttrium (90Sr/Y) in a large multicenter trial. BACKGROUND:Although adjunct...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,多中心研究

    doi:10.1111/j.1540-8183.2006.00188.x

    authors: Kaneda H,Honda Y,Morino Y,Lansky AJ,Yock PG,Bonan R,Fitzgerald PJ

    更新日期:2006-10-01 00:00:00

  • Effect on Clinical Restenosis of an Ultra-Thin-Strut Bare Metal Cobalt-Chromium Stent Versus a Thin-Strut Stainless Steel Stent.

    abstract:OBJECTIVES:To prospectively compare the impact of ultrathin-strut cobalt-chromium (Cro-Co) bare metal stent (BMS) versus thin-strut stainless steel (SS) BMS on clinically driven target lesion revascularization (TLR). BACKGROUND:Stent characteristics are an important determinant of restenosis. Thinner strut Cro-Co BMS ...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/joic.12300

    authors: Silenzi S,Grossi P,Mariani L,Fraccaro C,Vagnarelli F,Moretti L

    更新日期:2016-06-01 00:00:00

  • Intracoronary beta-radiation therapy for in-stent restenosis: long-term success rate and prediction of failure.

    abstract:OBJECTIVE:The following retrospective observational study assesses the long-term results of intracoronary beta-radiation therapy for patients with in-stent restenosis. BACKGROUND:Beta-radiation has been used to treat patients with coronary in-stent restenosis. However, long-term clinical success using this technique h...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2009.00522.x

    authors: Vlachojannis GJ,Fichtlscherer S,Spyridopoulos I,Auch-Schwelk W,Schopohl B,Zeiher AM,Schächinger V

    更新日期:2010-02-01 00:00:00

  • Comparison of the safety and efficacy of biodegradable polymer biolimus-eluting stents and durable polymer everolimus-eluting stents: propensity score-matched analysis.

    abstract:OBJECTIVES:We investigated and compared the clinical outcomes between biodegradable polymer biolimus-eluting stents (BES) and durable polymer everolimus-eluting stents (EES) in a single-center prospective registry. BACKGROUND:There is limited data regarding the safety and efficacy of the biodegradable BES compared to ...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/joic.12140

    authors: Lee JH,Lee JW,Youn YJ,Ahn MS,Ahn SG,Kim JY,Yoo BS,Lee SH,Choi E,Yoon J

    更新日期:2014-08-01 00:00:00

  • Stent implantation for coarctation in adults.

    abstract::Transcatheter dilatation is considered the elective treatment of residual coarctation. In the presence of native coarctation, dilatation is often effective but in the first months of life, and the risk of aneurysm formation is not low. The use of stents in adolescents and adults provides excellent results and seems to...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1046/j.1540-8183.2003.01004.x

    authors: Piéchaud JF

    更新日期:2003-10-01 00:00:00

  • Coronary angioplasty in high risk patients: comparison of elective intraaortic balloon pump and percutaneous cardiopulmonary bypass support--a randomized study.

    abstract::Forty patients undergoing percutaneous transluminal coronary angioplasty (PTCA) with severely impaired left ventricular ejection fraction (LVEF) < 30% were randomized between prophylactic intraaortic balloon pump (IABP) support (N = 20) and percutaneous cardiopulmonary bypass (PCPB) support (N = 20). The indications f...

    journal_title:Journal of interventional cardiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1540-8183.1995.tb00532.x

    authors: Kaul U,Sahay S,Bahl VK,Sharma S,Wasir HS,Venugopal P

    更新日期:1995-04-01 00:00:00

  • Interventional occlusion of congenital vascular malformations with the detachable Cook coil system.

    abstract:INTRODUCTION:Nonsurgical closure of pathologic vascular communications can be achieved by coil embolization. Different systems used in patients with congenital heart disease (e.g., patent ductus arteriosus) allow controlled release of the devices. However, they are too stiff for coil occlusion of small or tortuous vess...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2001.tb00338.x

    authors: Sieverding L,Breuer J

    更新日期:2001-06-01 00:00:00

  • A hybrid surgical transcatheter strategy for treating severe para-right atrioventricular valvular regurgitation in a patient with left atrial isomerism.

    abstract::Paravalvular leaks are a recognized complication of valve replacement surgery. We report a 47-year-old man with left atrial isomerism, interrupted left sided inferior caval vein with unilateral left sided superior caval vein, a common atrium, and anomalous pulmonary venous connection to the coronary sinus, who had rec...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2007.00290.x

    authors: Kalantre A,Vettukattil J,Haw M,Veldtman GR

    更新日期:2007-12-01 00:00:00

  • Therapeutic angiogenesis: a fantastic new adventure.

    abstract::A significant proportion of patients with coronary artery disease have symptoms refractory to medical treatment, yet are unsuitable for conventional revascularization techniques, like percutaneous coronary intervention and coronary artery bypass surgery. Such patients are potential candidates for alternative forms of ...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,评审

    doi:10.1111/j.1540-8183.2002.tb01062.x

    authors: Harjai KJ,Chowdhury P,Grines CL

    更新日期:2002-06-01 00:00:00

  • Relationship between stent malapposition and incomplete neointimal coverage after drug-eluting stent implantation.

    abstract:BACKGROUND:Using optical coherence tomography (OCT), we evaluated the relationship between malapposed and uncovered struts following implantation of drug-eluting stents (DESs). METHODS:A total of 271 patients with 306 lesions who underwent DES implantation and follow-up OCT were included in the study. The lesions were...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2011.00706.x

    authors: Kim BK,Hong MK,Shin DH,Kim JS,Ko YG,Choi D,Jang Y

    更新日期:2012-06-01 00:00:00

  • Valve-in-valve transcatheter aortic valve implantation with CoreValve/Evolut R© for degenerated small versus bigger bioprostheses.

    abstract:OBJECTIVES:We present our single center experience with Medtronic CoreValve and Evolut R regarding procedural outcome and 3 years follow-up in patients with degenerated bioprostheses. METHODS:From 1645 patients who underwent transfemoral TAVI at our institution between February 2009 and December 2016, 37 patients with...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/joic.12498

    authors: Scholtz S,Piper C,Horstkotte D,Gummert J,Ensminger SM,Börgermann J,Scholtz W

    更新日期:2018-06-01 00:00:00

  • Diabetic retinopathy and coronary implantation of sirolimus-eluting stents.

    abstract:INTRODUCTION:The prognostic value of identifying the retinal status of diabetic patients undergoing coronary implantation of drug-eluting stents is unknown. METHODS:We evaluated the outcomes of 318 consecutive patients undergoing implantation of sirolimus-eluting stents for coronary artery disease. Patients were divid...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2007.00252.x

    authors: Ohno T,Takamoto S,Ando J,Morita T,Fujita H,Hirata Y,Shigeeda T,Hirose A,Nagai R

    更新日期:2007-04-01 00:00:00

  • Spontaneous late thrombolysis of an occluded saphenous vein graft subsequent to acute myocardial infarction treated with percutaneous coronary intervention to the native culprit vessel.

    abstract::A 67-year-old male with prior history of myocardial infarction and coronary artery bypass grafting (individual vein grafts to the left anterior descending artery [LAD] and right coronary artery) presented with an acute anterior ST elevation myocardial infarction and cardiogenic shock. The vein graft to the LAD was occ...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2006.00129.x

    authors: Shah RA,Khanal S,Kugelmass A

    更新日期:2006-04-01 00:00:00

  • Catheter selection for coronary angiography and intervention in anomalous right coronary arteries.

    abstract:BACKGROUND:An anomalous origin of the right coronary artery (ARCA) from the left sinus of Valsalva (LSOV) has been reported in 6-27% of patients with coronary anomalies. The unusual location and course of this anomaly poses a technical challenge for the interventionalist. Appropriate guiding catheter selection is criti...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2009.00463.x

    authors: Sarkar K,Sharma SK,Kini AS

    更新日期:2009-06-01 00:00:00

  • (Meta)-analysis of safety and efficacy following edge-to-edge mitral valve repair using the MitraClip system.

    abstract:OBJECTIVES:The authors investigated safety and efficacy of the MitraClip-System (MCS) using a systematic analysis. BACKGROUND:The safety and efficacy of the MCS continues to be debated, and randomized trials are still lacking. METHOD:A systematic literature search was conducted using common medical and scientific dat...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,meta分析,评审

    doi:10.1111/joic.12168

    authors: Bail DH

    更新日期:2015-02-01 00:00:00

  • Is it safe to close ASD with the guidance of transthoraxic echocardiography in pediatric population "ten years' experience of a single center".

    abstract:OBJECTIVE:Main purpose of this study is to emphasize the usage and safety of transthoracic echocardiography (TTE) in percutaneous atrial septal defect (ASD) closure in appropriate pediatric cases. BACKGROUND:Nowadays, percutaneous closure is preferred as treatment modality for ASD in pediatric age group. METHODS:Betw...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/joic.12197

    authors: Baykan A,Pamukcu O,Ozyurt A,Argun M,Onan SH,Sezer S,Uzum K,Narin N

    更新日期:2015-04-01 00:00:00

  • Indications of implantable defibrillator.

    abstract::Implantable cardioverter defibrillators are devices capable of detecting and terminating ventricular tachycardias or fibrillations. They are utilized in the treatment of severe ventricular tachyarrhythmias, and their efficacy in the prevention of sudden death is demonstrated. As a matter of fact, despite the new antia...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.1995.tb00931.x

    authors: Coumel P

    更新日期:1995-12-01 00:00:00

  • Fractional flow reserve in a patient with intermediate coronary stenosis and hypertrophic cardiomyopathy.

    abstract::We discuss the case of a 61-year-old male patient with hypertrophic cardiomyopathy and chest pain on exertion. Coronary angiography and intravascular ultrasound revealed an intermediate stenosis in the proximal site of the left anterior descending artery, while Tc-99m myocardial scintigraphy revealed exercise-induced ...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2002.tb01029.x

    authors: Tsukamoto M,Azuma A,Kuribayashi T,Kawasaki T,Yamamoto K,Kawata K,Sugihara H,Nakagawa M

    更新日期:2002-02-01 00:00:00

  • Ultrasound-Guided Percutaneous Balloon Aortic Valvuloplasty for Aortic Stenosis.

    abstract::Percutaneous balloon aortic valvuloplasty (PBAV), which is used to treat symptomatic aortic stenosis, requires ionizing radiation and contrast agent for imaging guidance. The aim of the study is to evaluate the feasibility and effectiveness of ultrasound-guided PBAV in patients with aortic stenosis. This case series i...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1155/2020/8086796

    authors: Li Y,Pang K,Liu Y,Li M,Wang H

    更新日期:2020-03-16 00:00:00

  • Stenting and Adjunctive Delivery of Paclitaxel Via Balloon Coating Versus Durable Polymeric Matrix for De Novo Coronary Lesions: Clinical and Angiographic Results from the Prospective Randomized Trial.

    abstract:BACKGROUND:There is limited comparative clinical data regarding the safety and efficacy profile of paclitaxel delivery via balloon versus stent-polymer matrix. In this study, we aimed to compare the clinical and angiographic results of two different methods of paclitaxel delivery among patients undergoing percutaneous ...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1111/joic.12210

    authors: Żurakowski A,Buszman PP,Milewski KP,Janas A,Gorycki B,Kondys M,Gąsior P,Michalak M,Boxberger M,Peppas A,Granada JF,Buszman PE

    更新日期:2015-08-01 00:00:00

  • Primary angioplasty in a patient with dextrocardia.

    abstract::Dextrocardia is a rare anomaly affecting 0.01% of newborns. We report on a case of a 60-year-old female with mirror-image dextrocardia who presented with an acute myocardial infarction and underwent primary angioplasty of the left circumflex artery. A review of the literature and technical challenges of the case will ...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2005.00350.x

    authors: Jauhar R,Gianos E,Baqai K,Roethel M,Kaplan BM

    更新日期:2005-04-01 00:00:00

  • Breakpoint: left main stent fracture--review of the literature.

    abstract::The incidence and morbidity associated with stent fracture are unknown. Recommendations and evidence-based treatment are lacking. We report a case of symptomatic fracture of a sirolimus-eluting stent advancing from the left main into the circumflex coronary artery, forming an acute angle with calcifications at the hin...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,评审

    doi:10.1111/j.1540-8183.2009.00484.x

    authors: Tizón-Marcos H,De Larochellière R,Larose E

    更新日期:2009-08-01 00:00:00

  • Drug-Coated Balloons: A Safe and Effective Alternative to Drug-Eluting Stents in Small Vessel Coronary Artery Disease.

    abstract:BACKGROUND:Drug-coated balloons (DCB) have been used to treat de novo small vessel coronary disease (SVD), with promising results and shorter dual antiplatelet therapy (DAPT) duration compared to drug-eluting stents (DES). We compared safety and effectiveness of the two treatments at 1 year. METHODS:We reviewed 3,613 ...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/joic.12333

    authors: Sinaga DA,Ho HH,Watson TJ,Sim A,Nyein TT,Jafary FH,Loh JK,Ooi YW,Tan JK,Ong PJ

    更新日期:2016-10-01 00:00:00

  • Retrograde Coronary Chronic Total Occlusion Intervention Using a Novel Reverse Controlled Antegrade and Retrograde Subintimal Tracking.

    abstract::Chronic total occlusion (CTO) is a frequent finding in patients with coronary artery disease and when clinically indicated, remains one of the most challenging subsets for intervention. Although successful recanalization rates of CTO have remained suboptimal in percutaneous coronary intervention, evolving techniques i...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,评审

    doi:10.1111/joic.12268

    authors: Dash D

    更新日期:2016-02-01 00:00:00

  • A randomized trial of 5 versus 7 French guiding catheters for transfemoral percutaneous coronary stent implantation.

    abstract::Comparative studies between 5 French guiding catheter and others of larger size using the transfemoral approach to coronary stenting have not been described. Coronary stent implantation was performed in 90 patients in a randomized trial. The primary end-point was to compare the incidence of successful uncomplicated st...

    journal_title:Journal of interventional cardiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1540-8183.2007.00315.x

    authors: Büchler JR,Ribeiro EE,Falcão JL,Martinez EE,Büchler RD,Feres F,Maielo JR,Haddad N,Ramires JF,Ellis SG

    更新日期:2008-02-01 00:00:00

  • Safety and efficacy of percutaneous intramyocardial bone marrow cell injection for chronic myocardial ischemia: Long-term results.

    abstract:BACKGROUND:Intramyocardial injection of bone marrow cells (BMC) in refractory angina patients with chronic myocardial ischemia has shown to be safe and improve clinical status during short-term follow-up. However, scarce data are available on long-term (>12 months) safety and efficacy. Therefore, the occurrence of clin...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/joic.12408

    authors: Rodrigo SF,Mann I,van Ramshorst J,Beeres SL,Zwaginga JJ,Fibbe WE,Bax JJ,Schalij MJ,Atsma DE

    更新日期:2017-10-01 00:00:00

  • Comparison of Instantaneous Wave-Free Ratio (iFR) and Fractional Flow Reserve (FFR) with respect to Their Sensitivities to Cardiovascular Factors: A Computational Model-Based Study.

    abstract::While coronary revascularization strategies guided by instantaneous wave-free ratio (iFR) are, in general, noninferior to those guided by fractional flow reserve (FFR) with respect to the rate of major adverse cardiac events at one-year follow-up in patients with stable angina or an acute coronary syndrome, the overal...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1155/2020/4094121

    authors: Ge X,Liu Y,Yin Z,Tu S,Fan Y,Vassilevski Y,Simakov S,Liang F

    更新日期:2020-05-11 00:00:00