Fractional flow reserve in a patient with intermediate coronary stenosis and hypertrophic cardiomyopathy.

Abstract:

:We discuss the case of a 61-year-old male patient with hypertrophic cardiomyopathy and chest pain on exertion. Coronary angiography and intravascular ultrasound revealed an intermediate stenosis in the proximal site of the left anterior descending artery, while Tc-99m myocardial scintigraphy revealed exercise-induced myocardial ischemia in the anteroseptal wall and apical portion. Flow velocity-derived coronary flow reserve (CFR) and pressure-derived fractional flow reserve (FFRmyo) were both low (1.1 and 0.59), suggesting that the stenosis was functionally significant. Directional coronary atherectomy greatly improved the FFRmyo (0.99), the scintigraphic findings, and anginal pain but did not improve the CFR (1.2). FFRmyo was useful in assessing the functional significance of an equivocal coronary stenosis and its interventional resolution.

journal_name

J Interv Cardiol

authors

Tsukamoto M,Azuma A,Kuribayashi T,Kawasaki T,Yamamoto K,Kawata K,Sugihara H,Nakagawa M

doi

10.1111/j.1540-8183.2002.tb01029.x

subject

Has Abstract

pub_date

2002-02-01 00:00:00

pages

23-8

issue

1

eissn

0896-4327

issn

1540-8183

journal_volume

15

pub_type

杂志文章
  • In-hospital and 12-month postprocedural clinical outcome of coronary bifurcational lesion treatment with the endeavor stent.

    abstract:BACKGROUND:The zotarolimus-eluting stent (ZES) has been documented as significantly reducing restenosis and target lesion revascularization (TLR) requirement compared to bare metal stents (BMS). METHODS:In this single-centered, prospective study we sought to evaluate the short- and medium-term outcomes of ZES placemen...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2010.00538.x

    authors: Fernández-Guerrero JC,Herrador-Fuentes J,Sánchez-Gila J,Guzmán-Herrera M,Lozano C

    更新日期:2010-04-01 00:00:00

  • (Meta)-analysis of safety and efficacy following edge-to-edge mitral valve repair using the MitraClip system.

    abstract:OBJECTIVES:The authors investigated safety and efficacy of the MitraClip-System (MCS) using a systematic analysis. BACKGROUND:The safety and efficacy of the MCS continues to be debated, and randomized trials are still lacking. METHOD:A systematic literature search was conducted using common medical and scientific dat...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,meta分析,评审

    doi:10.1111/joic.12168

    authors: Bail DH

    更新日期:2015-02-01 00:00:00

  • Simple technique to ensure coaxial guidewire positioning for placement of iliac limb of modular aortic endograft.

    abstract::Endovascular abdominal aortic aneurysm repair using a modular bifurcated stent-graft requires the initial placement of the main component in the infrarenal aorta, followed by insertion of additional iliac stent-graft(s) to exclude aneurysm and to securely affix the device. Placement of the contralateral iliac componen...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,评审

    doi:10.1034/j.1600-0854.2003.8046.x

    authors: Dawson DL,Terramani TT,Loberman Z,Lumsden AB,Lin PH

    更新日期:2003-06-01 00:00:00

  • Left atrial anatomy and patient-related factors associated with adverse outcomes with the watchman device-a real world experience.

    abstract:OBJECTIVE:This study sought to identify patient and left atrial morphology specific factors associated with early complications for left atrial appendage occlusion with the Watchman™ (Boston Scientific, Natick, MA) device. BACKGROUND:Oral anticoagulation (OAC) is recommended for patients with atrial fibrillation, howe...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/joic.12374

    authors: Murarka S,Lazkani M,Moualla S,Verma DR,Pershad A

    更新日期:2017-04-01 00:00:00

  • Uneventful 25-year course of an intracardiac intravenous catheter fragment in the right heart.

    abstract::We describe a patient with an intracardiac intravenous catheter fragment in the right heart that was found during fluoroscopy. The catheter fragment had broken off from an intravenous catheter inserted 25 years previously when the patient was admitted after a road accident. There were no complications during these yea...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2002.tb01080.x

    authors: Van Den Akker-Berman LM,Pinzur S,Aydinalp A,Brezins M,Gellerman M,Elami A,Roguin N

    更新日期:2002-10-01 00:00:00

  • Angiographic Complete versus Clinical Selective Incomplete Percutaneous Revascularization in Heart Failure Patients with Multivessel Coronary Disease.

    abstract:Background:Patients with multivessel disease (MVD) often pursue complete revascularization (CR) during percutaneous coronary intervention (PCI) to improve prognosis. However, angiographic CR is not always feasible and is associated with some procedure-related complications in heart failure (HF) patients with MVD. Clini...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1155/2020/9506124

    authors: Chang CY,Chen CC,Hsieh IC,Hsieh MJ,Lee CH,Chen DY,Tsai ML,Ho MY,Yeh JK,Huang YC,Lu YY,Wang CY,Chang SH,Wen MS

    更新日期:2020-07-27 00:00:00

  • Low-dose protamine to facilitate earlier sheath removal from the femoral artery after peripheral endovascular intervention.

    abstract:OBJECTIVES:This study aimed to evaluate the safety of low-dose protamine administration to facilitate earlier vascular sheath removal. BACKGROUND:Vascular access complications are the most common cause of postprocedural morbidity in patients undergoing peripheral endovascular intervention (PEI). Prolonged manual compr...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2011.00642.x

    authors: Hanna N,Fiorilli P,Gaglia MA Jr,Torguson R,Vita A,Ben-Dor I,Xue Z,Waksman R,Bernardo NL

    更新日期:2011-06-01 00:00:00

  • Midterm Clinical Impacts of Biodegradable Polymer Everolimus-Eluting Stents Compared with Durable Polymer Everolimus-Eluting Stents: A 3-Year Propensity-Matched Study.

    abstract:Objectives:Our aim was to evaluate the safety and efficacy of biodegradable polymer everolimus-eluting stents (BP-EES) compared with durable polymer everolimus-eluting stents (DP-EES) in midterm. Background:There are few data about midterm clinical outcomes of BP-EES compared with DP-EES. Methods and Results:Between ...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1155/2020/2869303

    authors: Matsuda H,Kagase A,Tokuda T,Ochiumi Y,Murata A,Suzuki Y,Ito T

    更新日期:2020-04-20 00:00:00

  • Comparison of three treatment strategies for patients with triple-vessel coronary disease and left ventricular dysfunction.

    abstract:INTRODUCTION:Current guidelines recommend coronary artery bypass grafting (CABG) for patients with multivessel coronary disease and left ventricular (LV) dysfunction. However, some patients undergo percutaneous coronary intervention (PCI) or solely medical therapy (MT) in actual practice. The comparison of long-term ou...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/joic.12497

    authors: Jiang L,Xu L,Song L,Gao Z,Tian J,Sun K,Yu H,Xu B,Song L,Yuan J

    更新日期:2018-06-01 00:00:00

  • Prognostic Factors in Patients With Stemi Undergoing Primary PCI in the Clopidogrel Era: Role of Dual Antiplatelet Therapy at Admission and the Smoking Paradox on Long-Term Outcome.

    abstract:BACKGROUND:Several clinical and laboratory variables have an impact on the prognosis of STEMI patients undergoing PPCI; however, little is known about the role of ongoing DAPT at the time of the event and the smoking status as prognostic factors affecting the outcome of these patients. METHODS AND RESULTS:Seven-hundre...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/joic.12360

    authors: Ciccarelli G,Barbato E,Golino M,Cimmino G,Bartunek J,Di Serafino L,Di Girolamo D,De Bruyne B,Wijns W,Golino P

    更新日期:2017-02-01 00:00:00

  • Transcatheter closure of patent foramen ovale (PFO) in patients with paradoxical embolism: procedural and follow-up results after implantation of the Amplatzer®-occluder device.

    abstract:BACKGROUND:Prevalence of patent foramen ovale (PFO) with detectable right-to-left shunt is higher in young adults with transient ischemic attack (TIA) and stroke compared to the general population. So far, published series included different occluder systems, various indications and regimens of postprocedural anticoagu...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2010.00593.x

    authors: Fischer D,Haentjes J,Klein G,Schieffer B,Drexler H,Meyer GP,Schaefer A

    更新日期:2011-02-01 00:00:00

  • Transcatheter Aortic Valve Replacement in Patients with Aortic Stenosis Having Coronary Cusp Fusion versus Mixed Cusp Fusion Nonraphe Bicuspid Aortic Valve.

    abstract:Objectives:We aimed to assess the procedural and clinical results of transcatheter aortic valve replacement (TAVR) for nonraphe bicuspid aortic stenosis (AS) with coronary vs mixed cusp fusion. Background:It remains unclear whether cusp fusion morphology affects TAVR outcomes in patients with nonraphe bicuspid AS. Me...

    journal_title:Journal of interventional cardiology

    pub_type: 临床试验,杂志文章

    doi:10.1155/2019/7348964

    authors: Lei WH,Liao YB,Wang ZJ,Ou YW,Tsauo JY,Li YJ,Xiong TY,Zhao ZG,Wei X,Meng W,Feng Y,Chen M

    更新日期:2019-11-03 00:00:00

  • Intracoronary thermography: does it help us in clinical decision making?

    abstract::The concept of the "vulnerable" plaque has recently emerged to explain how quiescent atherosclerotic lesions evolve to cause clinical events. The morphologic and immunologic determinants specific for the vulnerable plaque have been reported: a large lipid core (>or=40% plaque volume) composed of free cholesterol cryst...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,评审

    doi:10.1111/j.1540-8183.2005.00090.x

    authors: Toutouzas K,Drakopoulou M,Stefanadi E,Siasos G,Stefanadis C

    更新日期:2005-12-01 00:00:00

  • Implementation of the transradial approach for coronary procedures is not associated with an elevated complication rate and elevated radiation patient exposure.

    abstract:BACKGROUND:The transradial approach for coronary procedures is associated with a low complication rate, but specific training is considered mandatory. METHODS:Procedural characteristics (contrast dye: CD; fluoroscopy time: FT, patient radiation dose: RD) and local complication rates were prospectively assessed in 784 ...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2010.00603.x

    authors: Lehmann R,Ehrlich JR,Weber V,de Rosa S,Gotarda MN,Schächinger V,Zeiher AM,Fichtlscherer S

    更新日期:2011-02-01 00:00:00

  • Diabetic retinopathy and coronary implantation of sirolimus-eluting stents.

    abstract:INTRODUCTION:The prognostic value of identifying the retinal status of diabetic patients undergoing coronary implantation of drug-eluting stents is unknown. METHODS:We evaluated the outcomes of 318 consecutive patients undergoing implantation of sirolimus-eluting stents for coronary artery disease. Patients were divid...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2007.00252.x

    authors: Ohno T,Takamoto S,Ando J,Morita T,Fujita H,Hirata Y,Shigeeda T,Hirose A,Nagai R

    更新日期:2007-04-01 00:00:00

  • Is direct stent implantation without predilatation safe? Acute and long-term outcome.

    abstract::Direct stenting could potentially lead to a reduction in dissections, time, and restenosis at 6-month follow-up. Using the premounted Palmaz-Schatz Crown stent elective stenting was performed without predilatation in 61 consecutive patients who were compared with a control group of provisional stenting. All patients u...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2002.tb01101.x

    authors: Rahel BM,Suttorp MJ,Ten Berg JM,Bal ET,Ernst SM,Mast EG,Kelder JC,Plokker HW

    更新日期:2002-08-01 00:00:00

  • Striving to meet targets for ideal treatment of acute myocardial infarction in Brazil: Data from the Midwest region.

    abstract:OBJECTIVES:To evaluate the systematic chain of care for patients with acute ST-elevation myocardial infarction (STEMI) referred for primary angioplasty in a capital city in Midwestern Brazil. BACKGROUND:Acute myocardial infarction is recognized as an important cause of morbidity and mortality and as a public health pr...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/joic.12493

    authors: Carvalho G,Rassi S,Guérios E,Curado FAM,Bastos AT

    更新日期:2018-08-01 00:00:00

  • Transcranial doppler quantification of residual shunt after percutaneous patent foramen ovale closure: efficacy of the GORE(®) HELEX septal occluder.

    abstract:BACKGROUND:Ideally, percutaneous, mechanical closure of defects of the atrial septum should completely resolve shunt. To achieve this goal, more information is needed about the factors associated with device failure. METHODS:Consecutive patients with cryptogenic neurological events who had severe baseline Valsalva shu...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2011.00644.x

    authors: Sorensen SG,Smout R,Spruance SL

    更新日期:2011-08-01 00:00:00

  • Therapeutic angiogenesis: a fantastic new adventure.

    abstract::A significant proportion of patients with coronary artery disease have symptoms refractory to medical treatment, yet are unsuitable for conventional revascularization techniques, like percutaneous coronary intervention and coronary artery bypass surgery. Such patients are potential candidates for alternative forms of ...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,评审

    doi:10.1111/j.1540-8183.2002.tb01062.x

    authors: Harjai KJ,Chowdhury P,Grines CL

    更新日期:2002-06-01 00:00:00

  • Initial experience with paclitaxel-coated stents.

    abstract::Local delivery of immunosuppressive or antiproliferative agents using a drug-eluting stent is a new technology that is supposed to inhibit in-stent restenosis, thus providing a biological and mechanical solution. This technique is a very promising. To date, several agents have been used, including paclitaxel, QP-2, ra...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,评审

    doi:10.1111/j.1540-8183.2002.tb01091.x

    authors: Grube E,Büllesfeld L

    更新日期:2002-12-01 00:00:00

  • Comparison of the systemic levels of inflammatory markers after percutaneous coronary intervention with bare metal versus sirolimus-eluting stents.

    abstract:BACKGROUND:Percutaneous coronary intervention (PCI) with bare metal stent (BMS) deployment causes plaque disruption and a rise in systemic levels of C-reactive protein (CRP), interleukin (IL)-6, and monocyte chemoattractant protein (MCP)-1. Our aim is to study whether PCI with sirolimus-eluting stent (SES) use attenuat...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1540-8183.2009.00429.x

    authors: Rebeiz AG,Zoghbi E,Harb R,Youhanna S,Skouri HN,Dimassi A,Abou-Nader G,Nasrallah A,Sawaya J,Gharzuddine W,Alam S

    更新日期:2009-04-01 00:00:00

  • Predictors of recurrent in-stent restenosis after beta-radiation: An analysis from the START 40/20 trial.

    abstract:OBJECTIVE:The purpose of this study was to identify potential predictors, including clinical, procedural, angiographic, and intravascular ultrasound (IVUS) parameters, for recurrent in-stent restenosis (ISR) following beta-radiation 90Strontium/Yttrium (90Sr/Y) in a large multicenter trial. BACKGROUND:Although adjunct...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,多中心研究

    doi:10.1111/j.1540-8183.2006.00188.x

    authors: Kaneda H,Honda Y,Morino Y,Lansky AJ,Yock PG,Bonan R,Fitzgerald PJ

    更新日期:2006-10-01 00:00:00

  • The impact of atrial fibrillation on transcatheter mitral valve repair outcomes: A propensity-matched analysis.

    abstract:BACKGROUND:The concomitant presence of atrial fibrillation (AF) in the setting of Transcatheter Mitral Valve Repair (TMVR) represents a clinical challenge. Despite the high AF burden in patients presenting for the TMVR procedure, there are no studies that evaluate the impact of AF on in-hospital outcomes of TMVR in a n...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/joic.12568

    authors: Subahi A,Munir A,Abubakar H,Akintoye E,Yassin AS,Adegbala O,Alraies MC,Elder M,Mohamad T,Kaki A,Schreiber T

    更新日期:2018-12-01 00:00:00

  • New technique for fenestration of the interatrial septum.

    abstract::Achieving controlled flow between the systemic and pulmonary venous circulations is desirable in many complex congenital heart diseases. This includes the Fontan circulation, primary pulmonary hypertension, double inlet ventricles, or hypoplastic left heart with obstruction to the atrioventricular valve. As no specifi...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2006.00155.x

    authors: Sivaprakasam M,Kiesewetter C,Veldtman GR,Salmon AP,Vettukattil J

    更新日期:2006-08-01 00:00:00

  • Comparison between the safety profile and clinical results of the Cook detachable and Gianturco coils for transcatheter closure of patent ductus arteriosus in 272 patients.

    abstract:OBJECTIVES:We evaluated the occlusion rate and safety of Cook detachable coils versus Gianturco coils in transcatheter closure of patent ductus arteriosus (PDA). BACKGROUND:The Cook detachable coil recently was introduced in an attempt to improve the safety of transcatheter closure of PDA. METHODS:Between January 199...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8183.2001.tb00730.x

    authors: Galal MO,Bulbul Z,Kakadekar A,Fatani AE,de Moor M,el-Oufi S,Solymar L,al-Fadley F,Fawzy ME

    更新日期:2001-04-01 00:00:00

  • Effect of Paclitaxel-eluting versus sirolimus-eluting stents on coronary restenosis in Korean diabetic patients.

    abstract:BACKGROUND:With the introduction of drug-eluting stents (DES), the angiographic rates of restenosis have reduced dramatically but less prominently in diabetic patients. We compared the effects of sirolimus-eluting stents (SES) versus paclitaxel-eluting stents (PES) on 6-month angiographic and clinical outcomes in Korea...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1111/j.1540-8183.2008.00353.x

    authors: Kim MH,Hong SJ,Cha KS,Park HS,Chae SC,Hur SH,Gwon HC,Bae JH,Lim DS

    更新日期:2008-06-01 00:00:00

  • Network meta-analysis comparing iFR versus FFR versus coronary angiography to drive coronary revascularization.

    abstract:AIMS:Instantaneous free-wave ratio (iFR) has been recently demonstrated non-inferior to fractional flow reserve (FFR) to drive coronary revascularization; however, no study has compared iFR versus coronary angiography (CA). We performed a network meta-analysis to evaluate efficacy and safety of iFR- versus CA-guided st...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章,meta分析

    doi:10.1111/joic.12551

    authors: Verardi R,Fioravanti F,Barbero U,Conrotto F,Omedè P,Montefusco A,Moretti C,D'Amico M,Rinaldi M,Escaned J,D'Ascenzo F

    更新日期:2018-12-01 00:00:00

  • Evaluation of Left Main Coronary Artery Using Optical Frequency Domain Imaging and Its Pitfalls.

    abstract:Objectives:We aimed to assess the quality of optical frequency domain imaging (OFDI) of the left main (LM) arterial wall and describe and analyse potential artefacts in this setting. Background:OFDI is increasingly used to assess ambiguous lesions and optimize LM percutaneous coronary intervention. However, its abilit...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1155/2020/4817239

    authors: Roule V,Rebouh I,Lemaitre A,Bignon M,Ardouin P,Sabatier R,Labombarda F,Blanchart K,Beygui F

    更新日期:2020-06-12 00:00:00

  • Periprocedural management and in-hospital outcome of patients with indication for oral anticoagulation undergoing coronary artery stenting.

    abstract:PURPOSE:In patients on oral anticoagulation (OAC) undergoing coronary stenting (PCI-S), procedural management and in-hospital outcome have never been specifically and prospectively investigated. Also, the contribution of early bleeding to the relevant hemorrhagic rate reported at follow-up with triple therapy of OAC, a...

    journal_title:Journal of interventional cardiology

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1111/j.1540-8183.2009.00468.x

    authors: Rubboli A,Colletta M,Valencia J,Capecchi A,Franco N,Zanolla L,La Vecchia L,Piovaccari G,Di Pasquale G,WARfarin and Coronary STENTing (WAR-STENT) Study Group.

    更新日期:2009-08-01 00:00:00

  • Diagnostic accuracy of instantaneous wave free-ratio in clinical practice.

    abstract:AIMS:To evaluate the correlation between iFR and FFR in real-world clinical practice. METHODS AND RESULTS:Retrospective, single-centre study of 229 consecutive pressure-wire studies (np  = 158). Real-time iFR and FFR measurements were performed for angiographically borderline stenoses. Functionally significant stenose...

    journal_title:Journal of interventional cardiology

    pub_type: 杂志文章

    doi:10.1111/joic.12422

    authors: Ding WY,Nair S,Appleby C

    更新日期:2017-12-01 00:00:00